| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.8 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹30.3 L+₹3.5 L (13.1%)Rejected-Finance 67 B PANDU TEMPLE GHAT PANDU TEMPLE GHAT NEAR WEST GUWAHATI BED COLLEGE KAMRUP ASSAM 781012 | KAMRUP METRO | ASSAM | 781012 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹30.7 L+₹3.8 L (14.3%)Rejected-Finance B S ROAD KOLIBARI TEZPUR 784 001 DIST SONITPUR ASSAM | SONITPUR | ASSAM | 784001 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹31.5 L+₹4.7 L (17.4%)Rejected-Finance NIL | NA | NA | 121004 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹33.1 L+₹6.2 L (23.2%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
13 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (NORTH) TEZPUR
GE (NORTH) TEZPUR, C/O 99 APO
REPAIR OF MES WATER SUPPLY INSTALLATION AT NAA UNDER GE (N) TEZPUR
2023_MES_619023_1
GE(N)/TEZ/2023-2024/8768
Open Tender
Civil Works
Item Rate
335 days
GE (NORTH) TEZPUR
As per tender documents
8 documents required · 8 mandatory
₹500
GE (NORTH) TEZPUR
₹80,000
18 Nov 2023
15 Sept 2023
20 Oct 2023
15 Sept 2023
13 Oct 2023
29 Sept 2023
Amount
Dismantling of plain or corrugated steel sheeting, any gauge, thickness including any pattern roof coverings complete all as specified and as directed.
Dismantling timber scantlings in framed works, 40 sqcm and over in section, in any position complete all as specified and as directed.
M&L for lowering of existing truss of wooden/steel section and after repairing and refixed complete all as specified and directed.
Taking down wooden chowkhats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50 sqm each complete all as specified and as directed
Taking down wooden chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 sqm but not exceeding 4.00 sqm each complete all as specified and as directed
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
Taking down plastering on lathing (other than wire-netting), without removing lathing, in cement mortar (one side only measured in cases where both sides are plastered complete all as specified and directed.
Demolition of brick work or stone/boulder masonry laid dry complete all as specified and directed.
M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated corrugated steel sheet, any pattern corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed.
S&F pre-painted galvalume aluminium zinc coating GI based trapezoid profile steel sheet 0.50 mm thick of and colour having tensile strengh of 550 Mpa as in ridge, eaves sheet/board covering, valley gutter or of similar type, fixed with self tapping screws with bitumen washer to truss members of any material, complete all as specified and as directed.
M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in ridge/ valley/ gutter fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed.
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, tubular/hollow section, channel or flat sections) including distance pieces, cleats etc. using Fe-410W (Grade E-250 quality "A") including necessary welding complete complete all as specified and directed.
M&L in repair for second class HW scantalling, wrought, in any position for framed work , jointing with necessary nails, nut bolts etc including necessary supports for truss structure complete all as specified and directed.
S & F hot rolled medium and high tensile structural steel of grade E 250 quality C conforming to IS 2062: 2011 as in framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and as directed.
S&F rolled section as in framing for door/vent/CB/chowkhats, wind tie and the like using angle, tee, hollow tubes etc., cleat and connecting plates complete (Butt hinges shall be measured and paid for separately) using Fe 410-W (Gde-E-250) quality "A" complete all as specified and directed.
S&F mild steel work such as in guard bars, grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; and of similar type of work conforming to Fe 290, Gde-E-165 complete all as specified and directed.
S & F 1.60 mm thick mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and as directed.
Material and labour for 70mm dia cast iron Ball grade F.G. 150 machined in pulleyes and similar articals complete in all respect as specified and directed.
S & F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed.
S & F 75 mm size butt hinges, extruded aluminium alloy with brass wire pin, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996, hinge designation 125A22 as per IS 205: 1992 complete all as specified and as directed.
S & F aluminium barrel tower bolts with barrel and bolt of extruded sections of aluminium alloys, 150 mm long, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 with transparent anodic film complete all as specified and as directed.
S & F cast aluminium alloy handle, cast type, 125 mm size, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed.
S & F aluminium alloy sliding door bolts with hasp, staple and fixing clips of sheets, or extruded sections and fixing bolts and sliding bolts of extruded sections of aluminium alloy, 300 mm long, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed.
S & F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and as directed.
S & F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded complete all as specified and as directed.
S & F steel ventilators with top hung shutters including hinges, steel peg stay complete all as specified and as directed.
S&F 100mm size mild steel butt hinges complete all as specified and directed.
M & L for preparation of new or previously untreated wood or wooden surfaces, of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
M&L for preparation of old decorated wooden surfaces with pre mixed wood filler used as putty of grith exc 10cm and applying two coats of synthetic enamel paint complete all as specified and directed.
Preparation of newly or previously untreated steel surface of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed by Engineer-in-Charge
M&L for preparation of old undecorated steel surfaces with pre mixed steel filler used as putty and applying two coats of synthetic enamel paint complete all as specified and directed.
S & F flush door shutters, 30 mm thick, solid core of block boards construction, MR grade, commercial type with stiles, rails and lipping of timber as given in Group 2A and Group 2B of Annex B of IS 2202 (Part 1): 1999, both sides face panels of plywood as per IS 710: 2010, internally lipped complete all as specified and as directed.
M&L for preparation of old decorated surfaces of wall after complete scrapping down and using wall care putty to fill the voids and applying two coats of weather coat over a coat of alkali resistant priming paint complete all as specified and directed.
M&L for preparation of newly plastered surface of wall and applying two coats of weather coat over 3 mm thick wall care putty over a coat of primer including rubbish and all necessary preparation, complete in all respect as specified and directed.
M&L for preparation of new surface of plastered wall using wall care putty to fill the voids and applying two coats of oil bound distemper (OBD) and finished another one coat with spunge roller over including one coat of alkali resistant priming paint over 3mm thick (in two layer), wall care putty complete all as specified and directed.
M&L for complete removal of existing treatment on wall and applying two coats of oil bound distemper (OBD) and finished another one coat with spunge roller over one coat of alkali resistant priming paint over 3 mm thick (in two layers) wall care putty, complete in all respect as specified and directed.
M & L for brick work with sub class 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed.
M & L for brick work with sub class 'B' bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 complete all as specified and as directed.
Material and labour for plastering 15 mm thick on fair faces of brick work or concrete surfaces on ceilings in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and as directed.
M & L for rendering/plastering 15 mm thick in cement mortar 1:6 on faces of brick or concrete surfaces and finished the surface even and smooth without using extra cement complete in all respect as specifified and directed.
Material and labour for plastering 15 mm thick on stone masonry surfaces or other than fair faces of brick work or on one side of lathing (on vertical surfaces) in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and as directed.
M&L 15mm thick plastering on wall in cement mortar (1:6) finished even and smooth without using extra cement on other side of lathing or stone masonary surface other than fair face on other side of lathing complete in all respect as specifified and directed.
M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs, slab staging for water tanks, filling of pressed steel door frame, fixing of hold fasts and the like including weathering, slightly rounded or chamfered angles and throating including necessary formworks complete all as specified and directed by Engineer- in-charge.
Supply & fix sheet glass, ordinary quality, 4 mm thick and glazed with oil putty or fixed with beads in square not exceeding 0.5 Sqm in each pane complete all as specified and directed.
M & L for structural timbers of group B, first or second choice as per IS 3629: 1986 in fillets, square, rectangular or triangular in section, clean sawn, secured with screw, area exceeding 13 sqcm but not exceeding 25 sqcm including taking down complete all as specified and as directed.
Providing and laying coloured ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.18 Sqm in floors etc., set and jointed in neat cement slurry and pointed in white cement with pigment to match the tile colour over 15mm thick screed bed in cement mortar (1:6) including dismantling of floor tiles including cement mortar bedding of any thickness upto PCC/RCC surface and rubbish off the premises complete in all respect as specifified and directed.
Providing and laying coloured ceramic tiles 7 to 8mm mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.18 Sqm in skirting/dado etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match tile colour over 10mm thick rendering in cement mortar (1:4) including dismantling of wall tiles including cement mortar bedding of any thickness upto PCC/RCC/brick surface and rubbish off the premises complete in all respect as specifified and directed.
Providing and laying plinth protection of 75mm thick cement concrete (1:3:6) type C-1, (using 20mm nominal size crushed and graded stone aggregate), laid in alternate penals/bays and finished the surafce even and smooth without using extra cement complete all as specified and as directed.
M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate, 40 mm thick in sub base for laying tiles, pavings, floorings etc. complete all as specified and as directed.
M & L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc. complete all as specified and as directed.
M & L for brushing neat cement slurry with 3.0 kg of cement per square meter complete all as specified & directed by Engineer-in-Charge.
S&F Plastic dividing strips, 1.5mm thick of size 10/38 mm complete all as specified and directed.
S & F GI wire netting 0.90 mm dia and 13 mm mesh lathing to wood or metal studding, joists, etc. in walls, ceilings, stanchions, beams, etc. including all laps, cutting and waste complete all as specified and as directed.
M & L for hardcore (broken stone or boulders) of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
M&L for 18-20 mm thick machine cut kota stone slab flooring of size not less than 500 x 500 mm over 20 mm thick cement mortar (CM) 1:6 screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, complete in all respect as specified and directed.
M&L for 18-20 mm thick machine cut kota stone slab of size not less than 500 x 500 mm in riser of steps, skirting, dado and pillar over 15 mm thick rendering in cement mortar (CM) 1:4, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, complete in all respect as specified and directed.
M & L for RCC M20 (Design Mix) using 20 mm nominal size graded crushed stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or water supply pipes lines etc or not exceeding 10 sqm on plan and getting out in soft/ loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed.
Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed.
M & L for mild steel TMT bars 6 mm to 8 mm dia, cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height. Complete all as specified and as directed.
M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height. Complete all as specified and as directed.
M & L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished flat surfaces of concrete complete all as specified and as directed.
M & L for RCC M20 (Design Mix) using 20 mm nominal size graded crushed stone aggregate as in columns, pillars, piers, posts and struts complete all as specified and as directed.
M & L for formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished flat surfaces of concrete complete all as specified and as directed.
M & L for cement concrete in foundation, filling and mass concrete in M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
M&L for 100 mm 1:3:6 type C2 ( using 40 mm graded stone aggregate) as plinth protection/paving finish even and smooth without using extra cement complete all as specified and directed
M/S PK ENTERPRISE
Anil Kumar Sarmah
MD. LATIFUL AHMED HUSSAIN
M/S UDIPTA KUMAR BORAH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .