Provision of Electronic Interlocking along with Colour Light Signaling and Motor operated Points at Giddi Siding of CCL
2026_IPRCL_292053_1
ST/IT-11013/13/2026 S and IT Giddi
Open Tender
Electrical Works
Works
365 days
Giddi Siding
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹14.6 L
24 Sept 2026
24 Sept 2026
16 Oct 2026
24 Sept 2026
15 Oct 2026
29 Sept 2026
In Words
Group 11 A
Group 11 B
Group 11 C
Group 11 D
Provision of Electronic Interlocking along with Colour Light Signaling and Motor operated Points at Giddi Siding of CCL.
Description of Schedule/Bill
11 Group A
11 Group B
11 Group C
11 Group D
Total Cost of the Work
DESCRIPTION OF WORK
ELECTRONIC INTERLOCKING - SUPPLY
Supply of Electronic Interlocking for stations upto 200 Routes (Centralised/Distributed) excluding Panel Processor (Hot Standby) with Signalling functions up to 125 EI units as per Function table enclosed along with 5% spares, tools, manuals and Instruments as per RDSO specification RDSO/SPN /192/2019 ver 2.0 or latest .
Miscellaneous Related to EI
Supply of portable work station to run along with EI configuration tools, data inputs, simulation and functional testing, diagnostics and trouble shooting and commissioning of EI system.
Supply, Installation and Commissioning of EI VDU (Visual Display Unit, 4K with all suitable accessories Compatible to El Interlocking in Safe Mode 24x7 at controlling station. The item must comply minimum following specification:- a) Screen Size (Diagonal):- As below b) Resolution :- 4K c) Viewing angle degree: - 178x178 degree d) Brightness :- 500 Nits e) contrast ratio 4000:1 f) Backlit :- Direct LED g) Jack Interface: - HDMI -3 no. 1.2 DP, DVI USB 2.0 -2 no. CI Slot RF In AV In Component In (RCA5 Type) Digital Audio Out RGB In (D-sub 15pin)-PC PC Audio Input RS232C (D-Sub 9pin) RJ45 Stereo mini jack. h) Optical Out :- Available Note: - Screen size will be decided as per instruction of engineer incharge.
Approximate Screen size 75 inch
Supply of industrial grade embedded PC for operator VDU as per RDSO TAN No. STS/TAN/3007 Version 1.0 or latest with adequate storage memory to work in Hot standby mode.
AXLE COUNTERS -SUPPLY
Supply of Multi Section Digital Axle Counter (MSDAC) for mentioned detection Point by the purchased & track Section as per SIP, complete with all accessories, cable required with each track device & card viz. Axle detectors, Track Side Electronics/DAC field units, Central Evaluator (Central Evaluator unit should be housed in a pre-fabricated rack to be supplied along with the system), reset unit, Relay unit, Event Logger & Diagnostic terminals, etc. Required for different Detection Points & Track Sections as per RDSO Specifications No. RDSO/SPN/176/2013, Ver.3 or latest and OEM/ manufacturer’s specification and as per Annexures. (Quantity 01 No. = 01 DP) Inspection Authority: RDSO. Note:- As per WR’s Policy No 03/2024 Para No. 3.4.2 .e.iv “VDU/Reset box can be used for resetting. At Stations having more than 10 Track sections, the Railway propose to use a separate VDU-based resetting system. Such a VDU-based system if using a PC, it must be industrial grade”.
Installation of Central Evaluator of axle Counter, wiring from CT rack to Central Evaluator, installation and wiring of the reset box, LV box (if required) and associated power supply wiring. This includes supply of shielded cable of required conductor size for wiring between CT rack to evaluator rack, all other wires, power supply cable and wiring materials. The power supply cable from power room to Central Evaluator should not be less than 10 sq.mm PVC wire. Earthing as per OEM's guidelines & specification with their own material. This also includes painting and writing work on evaluator as per site requirement. NOTE: Installation /programming / configuration / commissioning of Axle counter equipment to be carried out in accordance with latest guidelines issued by Railways/ RDSO preferably by Authorised representative of OEM.
Description of Work
UNDERGROUND SIGNALLING COPPER CABLES
Supply of Outdoor signaling cable - 6 core x 1.5 sq.mm. in drum length of 1 Km.
Supply of Outdoor signaling cable - 12 core x 1.5 sq.mm. in drum length of 1 Km.
UNDERGROUND SIGNALLING POWER CABLES
Supply of Aluminium conductor POWER Cable - 2 core x 25 sq.mm.
UNDERGROUND TELECOM COPPER CABLES
Supply of Underground jelly filled , 0.9 mm dia, 6 Quad cable
PVC insulated Railway Signalling multi-core Indoor Cable 60core x 0.6mm Dia conforming to IRS:76/89 (Amd3) or latest.
Single core multi-strand wire 0.5 sq.mm. (16 conductor each dia. 0.2mm), as per IRS 76/89 (Amd3) or latest.
Flexible cable (Power wire), multi-strand copper conductors cross section 1x6 Sq.mm.( 85 conductor each diameter 0.30 +/- 0.01) as per IS 694/1990 with insulation thickness of 0.80 mm nominal conductor resistance 3.30 ohms/km and test parameters are as per IRS(S)76/89 or latest.
Flexible cable (Power wire), multi-strand copper conductors cross section (1x16Sq.mm).101 Conductors each diameter 0.45 +/- 0.01 as per IS 694/2010 with insulation thickness of 1.2mm nominal conductor resistance 1.127 Ohms/Km and test parameters as per IRS(S) 76/89 or latest.
Flexible cable (Power wire), multi-strand copper conductor's cross section 25 Sq. mm (0.4x196) as per specn. IS 694/2010 with latest amendment, and test parameters as per IRS(S) 76/89.
DESCRIPTION OF WORK
CARPENTRY
Pyrotech Workspace make New Modular Control Desk size 4102x2576 mm for provision of 02 Nos. Monitors made in "XLAT" system. 1. Table Top: The material of the working surface shall be made of thermally treated Aluminum -Trihydrate and acrylic resin material supported on minimum 25 mm thick MDF base. 2. Structure: Powder Coated Aluminum Sturdy Structure and extreme side Aesthetic Legs. The structure shall be rigid enough to withstand BIFMA X5.5: 2014 (Latest Edition). 3. Monitor Arm:- UL certified monitor arm assembly shall have auto lock, push & remove feature for quick release of VESA mounts and modular arm extensions for ease in maintenance and fixing of monitor by one technician within 30 seconds without using any tools. 4. Shutters & Side Legs: - Front and back shutters shall be of18 mm Laminated MDF Board with premium finish Side leg.
RELAYS - METAL TO CARBON
Supply of Relay -QNA1(Contact configuration 12F/4B or 8F/8B)
Supply of RELAY QECX (ON/OFF ASPECT)
Supply of Relay - QN1 (Contact configuration 12F/4B or 8F/8B)
Supply of Electronic Flasher Relay
PANEL, RACKS & FUSES
Supply of Main Cable Termination rack complete along with patching cable of 24 core or 16/02 sq.mm. as per requirement and as per practice of Railway.
Supply of Relay Rack Assembly (Q style) complete with racks, ladders, indoor jumper wire , fuse & holder, power cables etc.
Supply of Prewired Crank Handle cum Key lock Relay Box etc.
Supply of Non-deteriorating type fuse holders and fuse Links - Electric fuse for Railway Signalling rated voltage 240 AC/DC to Specn. No. IRS S.78/92 (IRS-S-78/97 Tentative) IS: 13703 (Part 2./Sec 2): 1993 suitable for E1 fuse 20 Amps SC-20 Holder Safe Clip / Knife edge type size E1 (R-SS) Amp.
Fuse holder 20 Amps Capacity
Fuse links 16 Amps
Fuse links 10 Amps
Fuse links 2 Amps
Fuse links 6 Amps
Design, fabrication and supply of Fuse Auto Changeover System for 32 Nos. of external non-deteriorating type fuses or 'G' type fuses from 0.6 Amp to 4 Amp capacities used in signalling circuits. System shall have 8 cards with monitoring arrangement of 4 fuses in one card. As per RDSO Spec. RDSO/SPN/209/2012 Ver.2.0 or latest amendment if any.
Design, fabrication and supply of Fuse Auto Changeover System for 24 Nos. of external non-deteriorating type or 'G' type fuses from 4 A to 10 Amp capacities generally used for point operaton circuits. System shall have 6 cards with monitoring of 4 fuses in one card. As per RDSO Spec. RDSO/SPN/209/2012 Ver.2.0 or latest amendment if any.
DATA LOGGER
Data logger system for Railway S&T installation As per spec. IRS: S-99 2006 (Amdt-3) or latest. Central Monitoring Unit (Hardware Configuration as per Annexure) with UPS minimum 06 hrs battery backup and required Software tools. This also includes the supply of one no composite computer & printer table (Godrej workstation table) for keeping the Processor module and one no Godrej make operator chair model PCH7001. 1024 digital and 32 analog inputs.
POWER SUPPLY
Supply of SMPS based Integrated Power Supply (IPS) confirming to RDSO Specification: RDSO/SPN/165/2012 (versions 3.0) or latest in RE area with Remote indication panel (Central) along with batteries as per enclosed Drawing and list of spares as per enclosed Annexure. Firm,s offer: Supply of SMPS based Integrated Power Supply (IPS) confirming to RDSO Specification: RDSO /SPN/165/2012 (versions 3.0) in RE area with Remote indication panel (Central) along with batteries as per enclosed Drawing and list of spares as per enclosed Annexure- A. Make/Brand: Self (500 AH)
Supply of Single Phase Air Cooled, Silent DG set ( CPCB compliant)of 15 KVA.
Microcontroller based programmable static switching module (Auto changeover) of Reliance Electricals Make or similar, with an at a glance LCD display suitable for break-less switching between two DC supplies as per attached technical specifications.
Upto 40A for 20-110VDC. Model No: RE-SDSM-40.
OUTDOOR SIGNALING WORK
PVC insulated Railway Signaling multi-core Indoor Cable 1mm x 24 mm x 1 mm Dia conforming to IRS:76/89(Amd3) or latest.
PVC insulated Railway Signaling multi-core Indoor Cable 1 mm x 40 mm x 0.6mm Dia conforming toIRS:76/89(Amd3) or latest.
Supply of 24 fibre armoured optic fibre cable
TRENCHING, LAYING & PROTECTION WORK
Supply of RCC pipes 150mm dia, 2 Mtr long along with collars
Supply of DWC pipe of size 120 mm outer dia & 102 mm inner dia.
Supply of SPLIT DWC pipe of size 200 mm outer dia & 175 mm inner dia.
Supply of Galvanized Iron pipe 100 mm dia `B' class with end clamps
Supply and jointing of Quad cables with theromoshrinkable jointing kits
COLOUR LIGHT SIGNALS
Supply of 2 aspect Colour light signal complete with Signal post, CI base, ladder, platform, front staging, CLS unit 2 aspect,Anchor bolt, nut washer, Universal lock with key etc
Supply of 3/4 aspect Colour light signal complete with Signal post, CI base, ladder, platform, front staging, CLS unit 3/4 aspect,Anchor bolt, nut washer, Universal lock with key etc
Supply of Junction type route indicator (2 way) along with OFF set bracket and Universal lock with key
Supply of Independent shunt signals complete with post, surface base, Position light shunt signal unit,Anchor bolts, Universal lock with key etc
Supply of Dependant type Position light shunt signal unit along with OFF set bracket,Universal lock with key etc
Supply of Calling on signal unit along with Universal lock with key etc
Supply of LED signal unit for main signal For RED/YELLOW/GREEN aspect
Supply of LED signal unit for junction type route indicator/ shunt/ calling-on.
POINT MACHINE
Electrical point operating machine - IRS Type,143 mm throw with lock & detector slides, Cable terminal box etc. with suitable ground connection
Ground connections, complete set suitable for IRS type / approved point Machine for ordinary turnout with tongue attachment insulation and other insulation as per RDSO Drg. S/3361/62/63 (for IRS type point machine) or RDSO Drg No.SA-9151/52 (for Siemens point machine) with latest amendments. However the ground connection shall be procured only after confirmation from Railway engineer as per site condition /type of machine/turnout.
Supply of GI bend pipe, 'B' class, 50mm dia for cable entry in point machines, alongwith required fixing arrangements as per standard practice on Central Railway. As per Drg No. RST.11835.
Supply of Key locking Checking Relay (KLCR) working on 24V DC,AC Immunized with different ward combination and contact configuration 4F/4B with 2 extra ward plates and with case,RDSO specification RDSO/SPN/219/2016 ver 1.0 or latest,confirming to IRS S-23 & S-34 & S-60,IRS S:46 Inspected by RSDO
LOCATION BOX
Supply of Location box -Full Case complete with E Type lock, Hylam sheet, Universal lock with key
Supply of Location box - Half Case complete with E Type lock, Hylam sheet, Universal lock with key
Supply of ARA Terminal blocks with links, 6 Way.
Supply of 4-conductor Modular Terminal as per RDSO Specification No RDSO/SPN/189/2004 or latest..
MISCELLANEOUS ITEMS
Supply of Office furniture set for relay room consisting of chairs, office table, Airy revolving & tilting cushion chair, steel almirah, steel stool of Godrej make
Supply of Electronic magneto telephone desk type
Various types of markers as:-P/C/G/A/IB markers
Maintenance tool kit complete as per list attached.
Steel Plain Almirah with 4 adjustable slaves Size: 1980mm height, 915 mm width and 485 mm depth. Make: Godrej Storewel Plain Large or Similar of reputed brand will be specified by Engineer in-charge.
Office Chair makes Godrej CH-7B or similar of reputed brand will be specified by Engineer in-charge.
Office Revolving Chair Godrej Make Model No.9u02r Bravo Or Similar of reputed brand will be specified by Engineer in-charge.
Office table with laminated top with three drawers on left hand side and one locker on the right hand side. Olive brown with duplicate keys. Make: Godrej Model T-9 or Similar of reputed brand will be specified by Engineer in- charge.
Fire Bucket
Chain
Stretcher
Wall clock Quartz make Samay model no. SQ587 or SQ129785 with sweep second or similar make/model of Ajanta M no.-957 or sceintife with 1.5 volt Eveready cell.
Voice Frequency cable repeater
Supply of 4 wire 5 way voice frequency cable repeater, station equipment complete along with rack, U link panel, isolation transformers and Power supply including battery charger with maintenance free battery. Each repeater equipment rack will be equipped with five equilizer amplifiers, isolation transformers for five circuits and with 2 numbers of way station telephones for each circuit with push button type telephones as per RDSO /spec /TC/34/2002 Version 4 or latest RDSO specification. It also inculdes 8 way Intercommunication card as per section 7 of the specifications.
6 Quad Work [Control and Way Stn Eqps]
Supply DTMF Based Head quarter Equipment (2/4 wire) with all accessories for controle office as per RDSO Spec.No.IRS TC :60/2007 or latest RDSO specification including 12 V power supply unit to suit RDSO spec. no.IRS. TC. 72/97 or latest RDSO specification and to be procured from RDSO approved firms only.
Supply of 4W DTMF HQ control room equipmemt with decentralised calling for section, deputy controls with mike and hand sets & for test room as per specification no. IRS:TC 34/2002/ver.4 or latest RDSO specification.
Supply of 4 Wire way station Equipment with DTMF signalling to RDSO Spec.No.IRS TC:60/2007 or latest RDSO specification with telephone to Spec.TC.38/97 or latest RDSO specification .
Supply of Power supply for telecom installation at way side equipment as per tec. Spec. IRS: TC-72/97 Amdt. 1 or latest RDSO specification.
Supply of Portable Emergency telephone 4 wire as per spec. no. IRS TC 75-99 with latest amendment 1,2or latest RDSO specification
6-pin Emergency Socket
VHF Set
VHF transreceiver simplex for mobile 5 watt. Motorola model no. GP 328 or similar with rechargeable batteries. This will include battery charger and one rechargeable spare battery.
Spare KNB -26 N 2000 mAH Ni-Mh Battery suitable for above VHF set , 5 Watt.
VHF transreceiver set simplex, 25 watt Motrola model no. GM 338 or similar at way station (SM/ASM office) with suitable antenna and 30M RF cable. This shall also include the power supply of the transreceiver and one BNC for VHF adapter.
Supply of Switch board cable 5 pair for indoor wiring.
Supply of Switch board cable 10 pair for indoor wiring.
Supply of Switch board cable 50 pair for indoor wiring.
OFC Work
Supply of Permananently lubricated HDPE pipe 40 / 33 mm dia. As per RDSO specification no. RDSO/SPN/TC/45/ 2013 Rev 2.0 or latest RDSO specification if any; suitable for armoured 24 fibre OFC cable including its accessories like plastic coupler, end plug, cable sealing plug and end cap etc as required for the OFC system based on survey report.
Supply of FCPC To SCPC 10 meter long patch cords with o db adaptors as TEC spec G/OJC-01/03 JAN99 or latest RDSO specification.
Supply of managed Expendable rack type STM-1 ADM L 1.1 as per Technical Spec. No. TEC GR No. GR/SDH-04/02 Mar 02 with amendment 1 , 2 ,3 & 4 or latest RDSO specification with STM-1 aggregate interface , 21 E1S and 4 Numbers of 10/100 Base T Ethernet Port order wire, power supply unit, sub rack installation material and accessories manual etc.The equipment should be fully wired for its ultimate capacity and provide redundency for power supply and synchronisation and other detail as given in chapter 3 ( model - TJ 100 MC1 )
Supply of SMPS battery chargers for telecom use 48v, 25 amps in N+1 configuration using 3 modules of 25 Amps(FR/BC) suitable for 200 AH LM Batteries with lightning and surge protection as per Specification no RDSO/SPN /TC/23/99 Version-4 or latest RDSO specification , with automatic swiching between the modules . N=2
supply of 200 AH capacity LM batteries as per specification no IRS/S/88/2004 or latest;24 no at each station with required no of porceillin insulator.The suitable wooden rack for keeping batteries shall also be supplied and it should be painted with two coats acid resistant paint.
Blowing of armoured Optical Fiber Cable into duct by using blowing machine and associated works .Before blowing the duct integrity shall be tested .If any defect shall be found during duct integrity test , the entire length of HDPE duct from one chamber to another chamber chamber is to be replaced by Contractor at free of cost .
Supply of 50 pair Krone terminal complete with mounting arrangements.
Supply of Krone Termination Box 20 Pair with mounting arrangements
Solar Panel
Design, supply, installation, testing & commissioning with 5 years AMC of 10 KWP solar Power Plant (For OC/Gate)
Lightening arrester
Lightening protection of building having EI room, panel room,& IPS room mounted on Insulated STAND OFFs: provision of Faraday's cage gap of 5Mx5M catch ends i.e. Air Terminals, landing conductors (down conductor) connected to the Ground system. Supply of Franklin Rod as per NFPA-780 standards each 1 set consisting of 1. Air terminal, solid diameter 9.5mm made up of steel. 2. Mast height should be 4 meters, 50mm thickness with the galvanized pipe as per spec no. IS -1239, part 1/1990. 3. Erection of MAST height of 4 meters 50mm thickness with Required cement, sand, and stone as per the ratio of 1:3:6). 4. All other materials for the erection of the Mast and Air terminal.
Fire Alram
Provision of AUTOMATIC FIRE DETECTION & ALARM SYSTEM as per RDSO/SPN/217/2021version 2 or latest For Signalling System.
Site Testing Equipment
Supply of digital Insulation tester, auto range 100/500 volts.
Supply of Earth tester – Digital
Tools for testing - Digital multimeter of fluke make- 1no, Digital Clamp type AC & DC Ampere Meter - Fluke make- 1no.
Road Measuring Cycle, made of Aluminum with 05 digit counter, foldable with the bag.
DESCRIPTION OF WORK
ELECTRONIC INTERLOCKING - EXECUTION
Installation, Wiring, testing, Soldering of all EI equipments, earthing of EI Equipment, Relay Racks and Power Equipment etc. including supply power cable and Documents/Manuals etc. for EI of Stations upto 200 Routes (in ref to item no 36001 a).
Training (at site and/or work) of Engineers/Officers
Commissioning of Electronic Interlocking system
AXLE COUNTERS -EXECUTION
Installation of track device (double rail contact) including digging of trench, track crossing, laying of anti-rodent, anti-oxidant & non-flame propagating type Double Walled Corrugated (DWC) pipe as per IS- 14930 part- I or II or latest and all other accessories as per site requirement to be for laying of transmitter and receiver cable. The item also includes installation of EJB / Track side Electronics including foundation & earthing as per OEM's guidelines and Technical requirement & specification with their own material. NOTE: Installation / programming / configuration / commissioning of Axle counter equipment to be carried out in accordance with latest guidelines issued by Railways/RDSO preferably by Authorized representative of OEM.
DESIGN AND DRAWING WORK
Design of SIP and submission of copy (three copy) for approval.
Upto four line station
Design of Cable Route Plan submission of Three paper copies for approval.
Supply of diagrams consist of Floor Plan of Relay Room, Battery Room, Power Equipment Room, Data logger room, Power Supply Diagrams along with power supply calculation, Earthing Diagram, Power panel diagram, IPS wiring diagram, Auto change over diagram, Block circuit wiring diagram, Digital Axle counter wiring diagram and all other relevant drawing in original tracing along with AutoCAD in Pen Drive and six set copies after approval.
Upto four line station
Design and supply of cable courage plan, location particulars, Cable termination rack particulars, cable meggering report, earth resistance particulars, Traction bonding diagram, 1/2 wire count sheet and any other drawing in AutoCAD in A3/A4 size. The contractor shall initially supply 3 sets of circuits complete for approval of Railways. Railways will return one set to the contractor duly approved with alterations/corrections, if any. The contractor shall incorporate Railway’s alterations/corrections in the tracings without any deviation and submit all tracings complete in all respects to the Railways along with PENDRIVE & 4 sets of final approved drawings. This includes designing of cable coreage plan based upon I.P in consultation with engineer-in-charge For small/medium yards.
Station
Design & Supply of circuits and plans to suit layout given in the signalling plan of IBS/ABS/LCGATE/OC Hut. All plans and wiring diagram shall be prepared on Auto cad Drawing and supplied with CD/ USB Pen Drive. This will include supply of: 1. Control cum Indication panel diagram, 2.Route section plan, 3.squaresheet, 4.wiring diagrams 5. Relay rack/ Relay arrangements 6.Bus bar details, 7.Fuse analysis 8.contact analysis 9.Relay room tag block analysis 10. Panel tag block analysis, 11.Power panel diagram 12. IPS wiring diagram 13.Auto change over diagram 14.Power equipment arrangement with program switch 15. Block circuit wiring diagram 16 Digital Axle counter wiring diagram and all other relevant drawings. NOTE: The contactor shall initially supply 2 sets of documents (Paper Prints) for approval of Railways. Railway will return one set to the contactor duly approved with alterations/corrections, if any. The contactor shall incorporate Railways' alterations/corrections/ comments, if any, in the tracing & CD/USB Pen Drive without any deviation and submit all the tracings and Final CD/ USB Pen Drive complete with all respect for Approval of Railways. After Approval of Railways on the tracings, the contractor shall submit 3 sets of final approved diagrams tithe Railways within 15 days. He shall ensure the each sheaths a block for signature of railway official as well as a block for signature of firm, duly signed by the authorized signatory of the firm. The name of the work as given by Railways shall be written on every sheet under the work column. All the drawing shall be supplied in a good quality folder for each IBS/ABS/LC gate.
Independent checking ,verification of TOC/RRC by IRSE/IRSTELO licences holder for station Final having new EI installation up to 25 Routes.
INDOOR SIGNALLING WORK
Erection, Installation of Cable Termination Rack Assembly and Termination of cables
Installation of complete Relay Rack Assembly
Installation, wiring, testing and commissioning of Fuse Auto Changeover System of various type of fuses alongwith Audio-Visual indication as per RDSO technical spec No RDSO/SPN/209/2012 Ver 2.0 or latest .
DATA LOGGER
Installation, wiring, testing, and commissioning of Data logger complete along with accessories using Contractors' own wiring & fixing materials as per the following configuration. (It includes loading of NETWORKING software, networking of data logger, installation of FEP & Fault diagnosis system). The requisite communication cable/channel for networking will be arranged by Railway. 1024 digital & 32 analog inputs/ 4096 digital & 32 analog inputs. (All the Indoor & outdoor gears wiring in cataloged included in this along with laying 230V supply cable from IPS room,12 core cable from auto change over for monitoring supplied.) Note :- It included logging of all gears as per site incharge.
POWER SUPPLY
Installation & Commissioning of SMPS based Integrated Power Supply (IPS) (500 AH)
Installation and Commissioning of Single Phase Diesel Generator Set.
OUTDOOR EXECUTION WORK
Excavation of trenches at the depth of 1.0 Mtr. deep and 300 mm wide and back filling the trench after laying of cable along with supply and fixing of Cable route marker.
Excavation of cable trench of 1 m. depth & 300 mm. wide across the track crossing, road crossing, level crossing, platform & refilling.
Providing chase in hard rock
Perforation and Fixing of GI pipes on girder bridges, RCC bridges, drains, culverts, rocky places tunnels/deep cutting.
Fixing/ laying of DWC/RCC pipes
Laying of signaling / power / telecom / quad/OFC cable of various sizes in trench and pipes.
Placing of half round ( Split DWC ) pipe over the laid cable in open trenches
Supply and Fixing of 20 pair CTB and termination of quad/ jelly filled cable.
Testing of point to point insulation / continuity test for all laid out cables, Measuring Parameters and preparing the records
Horizontal direction drilling/boring without damage of surface of road /Track formation. The bore shall be 150mm dia & shall be at the proper depth as per site conditions decided by Engineer -in-charge . The ground level shall be considered ignoring the bankheight of the bank of the road. The length of the bore shall be minimum 4 Mtrs. long. This include insertion of different dia DWC pipe/GI/HDPE pipes coupling etc. as per difrection of Egineer In charge. Note: The cost of pipe is not included in this item. Contractor shall provide all material required for boring and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable.
COLOUR LIGHT SIGNALS
Excavation of pit, casting & plastering of concrete foundation for C.L.Signal and for signal ladder, Erection and wiring of complete signals along with supply of Signal number plate, wiring material etc.
Excavation of pit, casting & plastering of concrete foundation for shunt signal, erection and wiring of complete signals along with supply of Signal number plate, wiring material etc.
POINT MACHINE
Installation, termination, wiring, testing and commissioning of point machine including supply of wire, GI bend pipe, insulation sets etc
LOCATION BOX
Excavation of pit, casting of concrete foundations for Location Box-Single Case, erection of location box, supply of universal lock with key,Lamp holder 2 pin with switch, wiring material, wiring, testing and commissioning
Excavation of pit, casting of concrete foundations for Location Box-Half Case, erection of location box, supply of universal lock with key,Lamp holder 2 pin with switch, wiring material, wiring, testing and commissioning
Wiring in Existing Location box.
MISCELLANEOUS ITEMS
Maintenance Free Earth as per RDSO/SPN.197/ 2008 or latest consisting of : 1) Copper bond steel electrode 3 Mtr long 17mm dia with copper bonding thickness of min. 250 micron & UL listed & marked-01 No. 2) Earth enhancement compound RDSO Approved in sealed bag of 10 Kgs - 03 No. 3) Copper strip 150 x 25 x 6mm - 02 No. 4) Copper strip 300 x 25 x 6mm - 01 No. 5) 35 Sqmm Copper Cable to connect earth electrode to MEEB - 15 Mtr Approx.
Supply and Installation of various boards like BSLB/GWB/SLB boards etc
Supply of Earth electrode & Installation and connection of earth with equipments
Supply and Fixing of RE Protective Screens on signals
Provision of temporary Goomtis for NI working including Provision of Public Address system complete with Microphones, speaker etc in the yard during Non Interlock working
Supply of PVC wire multi strand copper conductor 16 Sq.mm colour : Green and providing earthing to the equipments, racks, etc., required insulation tapes, copper lugs, eye lets, etc., to be supplied by contractor
Supply, Installation & fixing of ISI Marked CO2 Gas 4.5Kg (Fully Reliable, controlled Discharge, Safe for use on live Electrical equipment) M.S body fire An extinguisher with a wall bracket as per following details: Cylinder Capacity: 4.5Kg., Fire Rating:55B Extinguisher Medium: Co2 Gas IS 15222 Temperature Range: -30 Drg. To 60 Drg. Discharge Time: More than Eight Seconds, as per the guidance of the Engineer
Supply and installation of Ultrasonic High Variable Frequency Rat Repellent Make: Verna or equivent
PAINTING
Painting, Letter writing, Numbering of termination particulars over all Indoor & Outdoor Gears at Complete STATION including LC gate
Fabrication & Printing,transportation and Installation of computer printed Boards
INFRINGEMENT REMOVAL, RELEASING, TRANSPORTATION
Release of complete indoor and outdoor equipment from stations/IBH/LCgates and transportation of released material to the depot.
Infringement Removal, Shifting/ lifting of existing location boxes/ signals/Track lead boxes, junction boxes etc along with foundation to adjacent place to facilitate earth work/ clearing infringement etc at stations including IBH, LC gates etc.
Loading, unloading and transportation of Signal and telecom materials.
Voice Frequency cable repeater
6 Quad Work [Control and Way Stn Eqps]
Installation and commissioning of 4 wire way station equipments, power supply unit at SP/SSP/Station/TSS/AEN/PWI/SI offices/Residences. The installation of way station equipment and power supply unit (supply covered under a separate item) shall be mounted on a MS angle rack. All the materials for installation, commissioning of 4 W equipment and power supply unit shall be provided by contractor.
Installation of emergency socket box including socket on the rail post in the section and yard at every one km. distance as per tapping chart supplied by the survey team. This will include wiring and termination of quad cable on the socket box mounted at 1 m height, clamped with 2 nos. U-Clamps, provision of concrete foundation of rail post in such a way that the rail post is one meter above the earth level. The concreting shall be in ratio of 1:3:6 of cement, sand and stone chips. The contractor shall jointly test with RVNL engineer for its satisfactory operation. This includes painting of Emergency socket post with alternate yellow and black strip of 6" width and painting of the socket box with grey colour paint and painting of arrows on the telephone posts/ cable markers to show the nearest Emergency socket as instructed by the engineer at site. RVNL will supply rails. Contractor should supply all other materials required. Cutting of rails to the required size shall be done by contractor.Rail posts and MS pipes of required lengths for fixing Emergency sockets will also be installed by the Contractor.
OFC Work
Supply and installation of OFC cable joint enclosure as per TEC No. G/OJC-01/03 Jan 99 or latest RDSO specification and splicing of optical fibre cables ( 24 Fibre) and testing.
Excavation for Jointing pit and provision of joint chamber of 1.2 mtr dia of 60 cm height with 2 piece cover on top and bottom cover with holes for drainage ( reinforcement drawing will be as per technical specification ) .This includes water cooling of chamber , backfilling and ramming of trench after laying and consolidated of soil as well as disposal of soil as per plan as advised by site engineer.
Supply installation testing & commisning including earthing of 42 u 19" covered racks for housing SDH and P- MUX equipments , DDF , FMS,MDF, using krone module etc. Complete with all fittings , wired and equipped with integrated protection modules for all channels and adequate numbers of cooling fans ,AC/DC power supply distribution panels , U Link panels and other hardware like runway , ladders etc.It should be possible to lock all the equipments with only order wire telephone remaining outside the rack ..The rack should be of APW President/Rittal make . The components of the rack are specified below. Broad description of rack is detailed below .Rack size 2200(mm) H X 600(mm) W xX 600( mm) D .Fixed side panels 42 U X 600 (mm) D front glass door plain 42 U X 600 (mm) D rear MS door plain 42 U X 600 (mm) D leveling screws - 4 numbers .Fan directly mounted on top 48 V DC 90 CFM - 2 Nos. earth connectivity kit - 1 No. Cable manager with cable loops-2nos.
Supply and installation of rack mounted 24 fIbre Fibre Distribution Management System part no FMS - 1U 24 FS 24 FP Raychem make including 24 Nos 0.2 db SC/PC adaptors and 24 Numbers. 900 micron 1.5 meter SCPC Pigtails RDSO Specification no. : RDSO/SPN/TC/037-2000(Rev.3) or latest.
Signalling Item
Supply and installation of ELD as per RDSO/ SPN/256/2002 or latest RDSO specification ( 12 CHANNEL)
Excavation trench 0.35 M wide 1.2 M deep in all categories of soils such as black cotton/ hard / murram/hardy soft rock . Filling th trench with earth to the level of surrounding ground after laying cables.NOTE: Where digging of trench as per specified depth is not possible, the depth can be reduced with the approval of the engineer in charge and the payment shall be made proportionately
Supply and fixing of MS-'C' channel of size 100mm x 50mm x1200mm with suitable clamps as per drawing No.S&T/RE/78/2/76 and fitting to GI pipes 65/50mm (to be supplied by RVNL) of Spec.IS-1239/Part-I/Light with couplings and with suitable clamps onGirder Bridges without drilling holes in the girders. GI pipers are to be drilled with 6 holes of 1/4" dis. per meters around the pipe in zip zag manner before laying the 6 meters pipe all materials to be supplied by Contractor.
Supply and fixing of RCC cable route marker as per Drg.No.SK/ 12/10 with engraving of Signal/Telecom cable one side and Zonal Rly on other side as per Railway Practice and painting on both sides of marker with numbering with black paint (Colour of the cable route marker paint and numbering may be changed/decided by the RVNL Site incharge). The markers should be fixed for a maximum of 30 mtrs to locate the Signaling/Telecom cable path and the marker should be visible about one feet above the ground for the clear visibility, the remaining portion of marker should be buried in the ground. Whererver track crossing are available, RCC markers are to be provided on both sides of the track for easy identification. All required materials (Supply, painting, transportation to site and fixing) are to be aranged by the Contractor.
Supply and Fixing of Rubber matting Thickness 2 MM as per IS: 15652-2006 with suitable adhesive material.
PAE (Public Address Equipment)System
Lightening arrester
Lightening protection of building having EI room, panel room,& IPS room mounted on Insulated STAND OFFs: Fabrication of Faraday's cage gap made up of 6x50mm galvanized steel tape mounted on Insulated STAND OFFs, cage gap of 5x5M approx. to suit building dimensions. There shall be two landing conductors i.e. Down conductor to be provided a low impedance path from the air terminal to the ground system, it shall have sharp bends. The down conductor is of copper tape 3x25mm mounted on insulated stand-offs. the inter-distance between two down conductors shall not have less than 10 mts. all connections shall be exothermically welded. The drawing of faraday's cage of building to be approved by engineer. The system consists of : Installation of Franklin Rod as per NFPA - 780 Standards each 1 set consisting of: (1) Fixing of Air terminal, solid diameter 9.5 mm made of steel (2) Fixing of Mast height of 4 metres 50 mm thickness with galvanised pipe as per spec no. IS-1239, Part 1/1990 (3) Erection of Mast on concrete foundation , with required cement , sand, stone in ratio 1:3:6) (4) All other materials for erection of Mast and Air terminal.
SITE FACILITIES (STANDARD RATES)
Providing Road Vehicle mentioned below for the use of Engineer/Employer @3000 Kms per month. BOLERO, SCORPIO, ERTIGA, MARAZZO or similar
Extra for running and maintenance of every additional km over and above 3000 kms as specified in item (1)
Supply and Installation HP ALL IN ONE DESKTOP Intel Core i5 12500t / 16GB Ram / 512gb Ssd/ Window 11pro/ 23.8" Screen /1Year Warranty
Description of signaling Gears
Signal Two aspect
Signal Three aspect
Signal Four Aspect
Junction route indicator - One way
Junction route indicator - Two way
Junction route indicator - Three way
Junction route indicator - Four way
Calling on Signal
Shunt Signal (Dependent)
Shunt Signal (Independent)
Track Circuit
Cross over Point (Signal ended/Double ended)
L.C.Gate - Traffic
G.F.Operated Point
Block Instrument
Axle Counter (One track section)
Crank Handle
Slot Outgoing
Slot Incoming
A Marker
DESCRIPTION
Relay rack with all fixtures and spacers.
IDF piller with fixtures.
Top frame angle for 2 relay rack.
Bottom frame angle for 2 relay rack.
IDF Bottom angle for 4 pillers.
IDF Top angle for 4 pillers.
Vertical support angle RH
Vertical support angle LH
Triangle Base assembly with 'J' Bolts, nuts, flat and spring washers.
Insulaters with fixing studs, spring and flat wahsers (one stud each for one insulater).Stud size-
Cable suopport assembly i.e. 'L' Bracket with 4 Nos. of bolts with nut, spring and plain washers for each 'L' Bracket.
16-way fuse holders (1.6 A/0.6A) mounting stripes with studs, spring and plain washers.
8-way fuse holders (6A) mounting stripes with stud, spring and plain washers.
Bracket for mounting 16-way/8-way fuse stripes with nuts, bolts and washers, i.e. (top brackets) All angles & stripes shall be 6mm and 5mm thick respectively.
Bracket for mounting 16-way fuse stripes (i.e. bottom bracket).
Cable supporting stripes
Cable supporting stripes
String rod with PVC insulation (sleeve) fixing bracket and stud with spring and plain wshers.
11-way Bus bar with 16 sq.mm. Lugs with PVC covers & fixing arangement (Bracket for fixing Bus bar cover) nut & bolts.
Square bar for fixing 8 Nos. of mini group base plate.
PVC sleeve (Tube) for insulting wire run support on IDF pillars and at other places.
a) Angle
Angle pieces for fixing wall support angles with 'J' bolts, Nuts, springs and plain washers having 13mm holes and 8mm holes.
Cable support 'U' bracket
C' Bracket for cable run support (5mm thick) 20mm width MS flat to be used.
C' Bracket for cable run support 5mm thick MS flat to be used.
Signal resistance mounting assembly complete with fixtures and fasteners.
Guide rails with fixtures and fasteners for :
MS Flat strip for mountiong AG timers
Resistance and condenser mounting assembly Qty. and size as per circuit requirements.
Anodized nuts and bolts with plain and spring washers.
Rack joining pieces.
Ladder for cable run support and power wiring with ladder joining pieces and bolts with nuts and washers.
Blue colour PVC sleeve.
Relay rack designation board, L shape complete with fixing clamps.
M.S. angle and straps should be of MALHOTRA or TISCO OR SIMILAR.
Above list is indicative, and suitable for Siemens type relays based installations, any other material required other than listed above or variation in quantity (more/less) shall be supplied as per site requirement free of cost.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.11 MB
Tender_Document.pdf
Tender Documents • 4.35 MB
NIT.pdf
NIA • 0.09 MB
OfferSheet.xls
Additional Documents • 0.03 MB
Tender_Document.docx
Additional Documents • 4.41 MB
Tender_Document.pdf
Additional Documents • 4.35 MB
Line daigram.pdf
Additional Documents • 0.06 MB
BoQ.xls
Additional Documents • 0.17 MB
ESP.pdf
Additional Documents • 0.14 MB
NIT.docx
Additional Documents • 0.02 MB
NIT.pdf
Additional Documents • 0.09 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .