| 1 | 1₹48.8 LAccepted-Finance T STATE BANJARAWALA DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | 1 | Accepted-Finance accept | |
| 2 | 2₹57.8 L+₹9.0 L (18.4%)Rejected-Finance | 2 | Rejected-Finance reject | |
| 3 | 3₹58.2 L+₹9.4 L (19.2%)Rejected-Finance | 3 | Rejected-Finance reject | |
| 4 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹61 L
EMD Value
₹1.2 L
Closing Date
14 Oct 2020, 10:00 amClosed
Executive Engineer, RWD, US Nagar
Rural works Department, Vikas Bhawan, Rudarpur
Installation work of Oxygen Supply pipe line in Ward of Civil Hospital, Khatima
2020_RES_26292_1
765/2-lekha/24.09.2020
Open Tender
Civil Works - Others
Item Rate
90 days
Khatima
Please refer Tender documents.
2 documents required · 2 mandatory
₹4,720
Yes
Executive Engineer, RWD, U S NAGAR
₹1.2 L
Yes
15 Oct 2020
5 Oct 2020
14 Oct 2020
5 Oct 2020
14 Oct 2020
5 Oct 2020
Amount
CIVIL WORK Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.in all kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinthsides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, leadup to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with Jamuna sand under floors, includingwatering, ramming, consolidating and dressing complete
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - -All work upto plinth level in 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
Providing and laying in position cement concrete of 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Brick work with F.P.S. bricks of class designation 75 in foundation and plinth inCement mortar 1:6 (1 cement : 6 coarse sand
Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing and laying in position specified grade of reinforced cement concrete1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness), includingReinforced cement concrete work in walls (any thickness), includingattached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate20 mm nominal size)
Reinforced cement concrete work in Beam,suspended floor roof having slop up to 15 degree landing balcony shelf chajjas lintels band plain windoe cills staircase & sprial stair case etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate20 mm nominal size)
Centring and shuttering including strutting,ropping etc. and removal of form forCentring and shuttering for foundations, footings, bases of columns, etc. for mass concrete.
Centring and shuttering including strutting,ropping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform.
Centring and shuttering including strutting,ropping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Centring and shuttering including strutting,ropping etc. and removal of form forColumns, Pillars, Piers, Abutments, Posts and Struts
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. TMT bars Fe500D
Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with dash fastener or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.
Providing and fixing M.S. Tubular frames for doors, windows, ventilators and nuts as required including fixing of necessary butt hinges and screws and applyinFixing with 15x3 mm lugs 10 cm. long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 ( 1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).
12 mm cement plaster of mix1:6 (1 cement : 6 fine sand
15 mm cement plaster on rough side of single or half brick wall of mix1: 6 (1 cement: 6 fine sand)
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer in- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete.40mm thick with 20mm nominal size stone aggregate.
Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction withframe of 1st class hard wood and well matched commercial 3 plyveneering with vertical grains or cross bands and face veneers on both Faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Providing and fixing ISI marked oxidised M.S. sliding door bolts withnuts and screws etc. complete :300x16 mm
Providing and fixing ISI marked oxidised M.S. tower bolt black finish, 200x10 mm
Providing and fixing ISI marked oxidised M.S. handles conforming to IS125 mm
Providing and fixing aluminium hanging floor door stopper ISI marked anodisedTwin rubber stopper
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows alll complete.With 4.0 mm thick glass panes.
Providing & fixing fly proff wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 m and nuts & bolts complete.Galvanised M.S. Wire gauze with 0.63 mm dia wire and 1.4 mm aperture on both sides.
Finishing walls with Acrylic Smooth exterior paint of required shadeNew work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm).
providing and applying white cement based putty of average thickness 1mm of approved brand and manufacture, over plastered wall surface to prepare the surface even and smooth complete
Distempering with 1st quality acrylic washable distemper (ready made) of approved manufacturer and of required shade and colour complete, as per manufacturer’s specificationTwo or more coats on new work.
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shadeTwo or more coats on new work
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size)
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification.
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C.projections.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete
OXEGEN PIPE LINE WORK Bed Head panel of 3 ft. long size
BS type Oxygen/vaccum Gas outlet
Electric switch and socket make anchor 2 sets in each panel
B.P.C. metal with humidifier bottel
Monitor tray 1 in each panel
S.S. Utility basket 1 in each panel
Copper pipe mexflow/mandev medical grade 12 mm
Copper pipe mexflow/mandev medical grade 15 mm
Copper pipe mexflow/mandev medical grade 22 mm
Copper pipe mexflow/mandev medical grade 28 mm
Two Gas alarm with gauge for wards and OT and Emergnecy
Main oxygen Manifold with N.R.V. and copper tail pipe with provision of 5+5 cylinders and middle frame
Emergency oxygen Manifold with N.R.V. and copper tail pipe with provision of 2+2 cylinder and middle frame
Two Gas area zonal valve box
Isolation valve 12 mm
Isolation valve 15 mm
Isolation valve 22 mm
High pressure Mox regulator double gauge
Eletric contec gauge alarm on emergency manifold for cylender pressure
Ward vacuum jar 600 ml poly carbonated
High pressure tubing for vaccum jars
Central Vaccum plant with dual vaccum pump of vaccum of 745 mm with 3 phase moter of 7.5 hp with storage tank of 1000 ltr. And all required accessories vaccum gague pressure switch etc.
Fully automatic control pannel for main oxygen manifold system complete with all accessories
OT suction trolley
ELECTRICAL WORK Wiring for light point /fan point/exhaust fan point/call bell point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed PVC conduit with modular switch,modular plate,suitable G.I.box and earthing the point with 1.5sq.mm.FRLS PVC insulated copper conductor single core cable etc.as required,complete in all respect.Group C
S/F of modular type 5/6 amps switch on the existing switch board,complete in all respect.
Same as above but for 3 pin 5/6 amps socket ,complete in all respect.
S/F of suitable size GI box with modular plate & cover in front and 3 pin 5/6 amps modular switch and socket on surface or in recess,complete in all respect.
Wiring for circuit/submain wiring alongwith earth wire with 2x 2.5sq.mm+1x 2.5sq.mm of FRLS PVC insulated copper conductor,single core cable in surface/recessed medium class PVC conduit as required.
Same as above but for 2x4.0sq.mm+1x4.0sq.mm earth wire.
S/F of suitable size GI box with modular plate & cover in front and 6 pin 5/6 & 15/16 amps modular switch and socket on surface or in recess,complete in all respect.
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way (4 + 24), Double door
S/F of 3 pin,5 amp.ceiling rose on the existing jonction box,including connection etc.as required.
S/F of single pole 5amps. to 32 amps.rating 240/415 volts,"C" series ,miniature circuit breaker,complete in all respect.
S/F of electronic fan regulator (modular)120-280 V.ISI marked on the existing switch board ,complete in all respect.
S&F of 100 Amp. 4 Pole. Isolator CAT A
Supply and fixing of LED Tube Light with batten suitable for up to 1 X 22 watt LED tube light fitting including tube on Surface complete in all respect. CAT- AAA
S&F of 100 Amp. 415 V metal clad TP HRC type switch fuse unit complete with HRC fuse on angle iron bracket complete in all respect.
S&F of 100 Amp. four pole change over switch on 40mm x 40mm x 6mm angle iron frame, including the cost of labour, T&P, painting and other material required for proper completion of the work as per direction and satisfaction of Engineer in charge.
Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc 25 sq. mm 3-1/2 core
S/F of LED street light fitting having die cast aluminium body and diffuser with driver set suitable for 30 to 40 watt,complete in all respect. Catt.AAA
Supply and fixing of water tight oblong 10 Watt LED bulkhead luminaire with driver set confirming to IP 65 and above Protection . complete in all respect. CAT-AAA
S/F of ceiling fan with 1200mm sweep having double ball bearing with reputed make(Havells etc.),complete in all respect.
CREATIVE HEALTHTECH PVT LTD
FROSSMAN DRUGS COMPANY
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .