Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.2 LAccepted-AOC G 4 106 107 1ST FLOOR SECTOR 11 ROHINI NEW DELHI 110085 | NORTH WEST | DELHI | 110085 | L1 | Accepted-AOC L1 | |
| 2 | L2₹10.7 L+₹55,225 (5.42%)Rejected-Finance 2ND FLOOR 2B SORAJ ESTATE ULUBARI K C PATOWARI ROAD ULUABRI KAMRUP ASSAM 781007 | KAMRUP METRO | ASSAM | 781007 | L2 | Rejected-Finance L2 | |
| 3 | L3₹10.9 L+₹66,575 (6.53%)Rejected-Finance 107 265 BRAHAMA NAGAR KANPUR UP 208012 | KANPUR NAGAR | UTTAR PRADESH | 208012 | L3 | Rejected-Finance L3 | |
| 4 | L4₹10.9 L+₹70,102 (6.88%)Rejected-Finance 306 BAKSHI HOUSE 40 41 NEHRU PLACE NEW DELHI 110019 DELHI | SOUTH EAST | DELHI | 110019 | L4 | Rejected-Finance L4 | |
| 5 | L5₹11.5 L+₹1.3 L (12.6%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
₹13.6 L
Closing Date
11 Jan 2022, 4:00 pmClosed
AGM (Engg-Elect)
AAI, Silchar Airport
Replacement of old and beyond repairable split ACs with new ACs at Silchar Airport
2021_AAI_99206_2
AAI/SIL/ENGG-E/AC/2021-22
Open Tender
Electrical Works
Works
90 days
AAI, Silchar Airport
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
Exempted
10 May 2022
4 Jan 2022
12 Jan 2022
4 Jan 2022
11 Jan 2022
4 Jan 2022
4 Jan 2022 - 7 Jan 2022
Amount
Supply of 1.5 TR, High wall Split A/Cs, 5 star rating, Inverter Split Units with R410a / R-32 Gas. (Both indoor and outdoor units), complete with filters, DX cooling coils connected to DX condensing units, Condenser coil - copper, including remote control operation for temperature adjustment, indoor unit blower speed, swing adjustment, auto restart, sleep mode turbo mode, with LED display for temperature i/c standard length of copper refrigerant pipe, copper electrical cable & drain pipe etc. Complete as per technical specifications.
Supply of 2 TR, High wall Split A/Cs, 5 star rating, Inverter Split Units with R410a / R-32 Gas. (Both indoor and outdoor units), complete with filters, DX cooling coils connected to DX condensing units, Condenser coil- Copper, including remote control operation for temperature adjustment, indoor unit blower speed, swing adjustment, auto restart, sleep mode turbo mode, with LED display for temperature i/c standard length of copper refrigerant pipe, copper electrical cable & drain pipe etc. Complete as per technical specifications.
Supply, installation, testing and commissioning of water cooler cum purifier suitable for operation on 230 V, 50 Hz AC supply with RO + UV purification, 80 ltrs storage capacity and 60 LPH water flow rate through the faucets, etc. complete as per technical specification.
Installation testing and Commissioning of following capacity Air-conditioning Unit Including making of necessary hole on concrete/brick wall and making good the same i/c providing suitable size PVC pipe for drawing the /drain pipe and wire etc through the concrete/brick wall as required. 1.5 TR High wall Split AC (Invertor type)
Installation testing and Commissioning of following capacity Air-conditioning Unit Including making of necessary hole on concrete/brick wall and making good the same i/c providing suitable size PVC pipe for drawing the /drain pipe and wire etc through the concrete/brick wall as required. 2 TR High wall Split AC (Invertor type)
Supply, fixing, testing and commissioning of wall mounting type automatic electronic voltage stabilizer suitable for split Air Conditioners single phase and auto voltage range of 180-270 V with high/low voltage cut off on delay etc complete as required. 4 KVA
Supply, fixing, testing and commissioning of wall mounting type automatic electronic voltage stabilizer suitable for split Air Conditioners single phase and auto voltage range of 180-270 V with high/low voltage cut off on delay etc complete as required. 5 KVA
Supply of following sizes XLPE insulated PVC sheathed unarmoured copper conductor flexible cable etc, complete as required. 4 core X 2.5 Sqmm.
Supply, installation testing and commissioning of extra refrigerant copper pipe suitable for 1.5 TR and 2 TR invertor type AC including leakage testing and providing fixing of insulation, soldering, necessary clamping arrangement etc. of following size as required. - 1/2
Supply, installation testing and commissioning of extra refrigerant copper pipe suitable for 1.5 TR and 2 TR invertor type AC including leakage testing and providing fixing of insulation, soldering, necessary clamping arrangement etc. of following size as required. - 1/4
Supply, installation testing and commissioning of extra refrigerant copper pipe suitable for 1.5 TR and 2 TR invertor type AC including leakage testing and providing fixing of insulation, soldering, necessary clamping arrangement etc. of following size as required. - 5/8
Supply, installation testing and commissioning of extra refrigerant copper pipe suitable for 1.5 TR and 2 TR invertor type AC including leakage testing and providing fixing of insulation, soldering, necessary clamping arrangement etc. of following size as required. - 3/8
Supply & fixing of 6mm thick Nitrile Rubber Tube Insulation for 1.5 TR and 2 TR refrigerant piping to prevent condensation, reduces energy losses and protects against frost on pipes of following sizes. - 1/2
Supply & fixing of 6mm thick Nitrile Rubber Tube Insulation for 1.5 TR and 2 TR refrigerant piping to prevent condensation, reduces energy losses and protects against frost on pipes of following sizes. - 1/4
Supply & fixing of 6mm thick Nitrile Rubber Tube Insulation for 1.5 TR and 2 TR refrigerant piping to prevent condensation, reduces energy losses and protects against frost on pipes of following sizes. - 5/8
Supply & fixing of 6mm thick Nitrile Rubber Tube Insulation for 1.5 TR and 2 TR refrigerant piping to prevent condensation, reduces energy losses and protects against frost on pipes of following sizes. - 3/8
Supply, installation testing and commissioning of UPVC pipes complete with fittings and 'U' traps for condensate drain piping with supports and thermal insulation as per specifications of following sizes. 25 mm
Supply, installation testing and commissioning of UPVC pipes complete with fittings and 'U' traps for condensate drain piping with supports and thermal insulation as per specifications of following sizes. 32 mm
Supply, installation testing and commissioning of MS frame L/chair type stand for fixing outdoor units of 1.5 TR & 2 TR split A/Cs complete as required.
RS COOLING APPLIANCES
Awasthi Electric Works
VOLKS ENERGIE PVT LTD
star refrigeration sales and service
Ganga Enterprises
ARNAV ENGINEERING CONSULTANCY SERVICES
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .