| Sl No | Description | Qty | Unit | M/s North East Electricals L1 | ABHISHEK ASSOCIATES L2 | Sterling And Wilson Pvt. Ltd L3 | Techno Electricals L4 | PAN POLAR ENGINEERS PVT. LTD. L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Sub-Head-I(Operation and Maintenance of E&M installation for Airport Services)
Operation, periodical preventive and breakdown maintenance services of Electrical and Mechanical installations for Airport Services (AS) at Airport Power House, Technical block cum ATC tower, Pump Houses, CISF Barrack, Terminal Building, City side car parking area, MT Pool, Residential Colony, Community Hall of Imphal Airport, day to day maintenance of E&M installations and conventional & addressable fire alarm system on round the clock basis / as per need basis including sundays & holidays involving attending to complaints/faults/breakdown and taking immediate rectification action for ensuring serviceability/ satisfactory working condition of the system, performing preventive maintenance checks, maintenance of records/ documentations, providing the services for collecting spares from AAI stores etc. complete as required.
For providing the above services adequate man power is required as per special conditions and Tecnical specification etc. The item excludes the repair maintenance of LT ACB, supply of required spares. ( Refer clause no. 14,16 & 46 of SCC also for quoting the rate).
i. 1st year | 12 | Month | - | - | - | - | - |
| 2.00 | ii. 2nd year | 12 | Month | - | - | - | - | - |
| 3.00 | Sub-Head-II (Painting, Rewinding, Testing etc.)
Re-painting of street light poles of following heights with aluminium paint of approved brand including scrapping and cleaning of surface as directed by E-I-C to give an even shade. (Two or more coats on old work etc. as required).
i. Upto 3 Mtr | 30 | Each | - | - | - | - | - |
| 4.00 | ii. Upto 6 Mtr | 70 | Each | - | - | - | - | - |
| 5.00 | iii. Upto 9 Mtr/12 Mtr. | 200 | Each | - | - | - | - | - |
| 6.00 | Re-painting of L.T. panels, chequered plate, electrical installations etc. with approved quality enamel paint of required colour in one or more coat with spray gun i/c scrapping & cleaning the surface complete as per site requirement and direction of E-I-C. | 200 | Sqm | - | - | - | - | - |
| 7.00 | Rewinding of exhaust fan/ceiling fan/ kit fan/ wall mounted fan as per original characteristics with super enameled copper wire and `E' class insulation material, replacement of the worn out bearing etc. as required i/c dismantling, making arrangment for transportation to workshop and reinstallation of the same at site, making supply connection, providing and fixing of necessary nut & bolts etc. (To be carried out as & when required). (The dismantled material will be taken by the contractor). | 50 | Each | - | - | - | - | - |
| 8.00 | Testing of dielectric strength of oil of 800kVA oil type 11kV/433V transformer of 605 Ltr oil capacity, oil filtration, heating and dehumidifying of oil to achieve recommended BDV and submitting the test report . | 2,420 | Ltr | - | - | - | - | - |
| 9.00 | 800kVA oil type 11kV/433V transformer maintenance i/c IR checking of LV/HV windings inbetween and w.r.t. earth, Winding resistance measurement, maintenace of Buchholtz device, cleaning and painting of transformer body, tightness of terminals, simulation of Buchholtz alarm & trip, winding temperature alarm & trip, Oil temperature alarm trip etc. as applicable and as directed by E-I-C and submision of report.
i. 1st year | 2 | Job | - | - | - | - | - |
| 10.00 | ii. 2nd year | 2 | Job | - | - | - | - | - |
Tender Value
₹1.1 Cr
EMD Value
₹2.2 L
Closing Date
15 Jun 2020, 6:00 pmClosed
AGM (E-E)-II
Airports Authority of India, Imphal International Airport.
Job contract for maintenance of E and M installations for Airport Services AS Ops and Non Ops areas at Imphal Airport for the year 2020 21 and 2021 22
2020_AAI_49111_1
AAI/IMP/AGME (E)/eNIT-MW-03/2020-21
Open Tender
AMC/ Maintenance Contracts
Item Rate
730 days
Imphal
As per NIT
2 documents required · 2 mandatory
₹1,120
Yes
GM AAI
₹2.2 L
Yes
9 Jul 2020
1 Jun 2020
23 Jun 2020
2 Jun 2020
15 Jun 2020
2 Jun 2020
2 Jun 2020 - 10 Jun 2020
Amount
Sub-Head-I(Operation and Maintenance of E&M installation for Airport Services) Operation, periodical preventive and breakdown maintenance services of Electrical and Mechanical installations for Airport Services (AS) at Airport Power House, Technical block cum ATC tower, Pump Houses, CISF Barrack, Terminal Building, City side car parking area, MT Pool, Residential Colony, Community Hall of Imphal Airport, day to day maintenance of E&M installations and conventional & addressable fire alarm system on round the clock basis / as per need basis including sundays & holidays involving attending to complaints/faults/breakdown and taking immediate rectification action for ensuring serviceability/ satisfactory working condition of the system, performing preventive maintenance checks, maintenance of records/ documentations, providing the services for collecting spares from AAI stores etc. complete as required. For providing the above services adequate man power is required as per special conditions and Tecnical specification etc. The item excludes the repair maintenance of LT ACB, supply of required spares. ( Refer clause no. 14,16 & 46 of SCC also for quoting the rate). i. 1st year
ii. 2nd year
Sub-Head-II (Painting, Rewinding, Testing etc.) Re-painting of street light poles of following heights with aluminium paint of approved brand including scrapping and cleaning of surface as directed by E-I-C to give an even shade. (Two or more coats on old work etc. as required). i. Upto 3 Mtr
ii. Upto 6 Mtr
iii. Upto 9 Mtr/12 Mtr.
Re-painting of L.T. panels, chequered plate, electrical installations etc. with approved quality enamel paint of required colour in one or more coat with spray gun i/c scrapping & cleaning the surface complete as per site requirement and direction of E-I-C.
Rewinding of exhaust fan/ceiling fan/ kit fan/ wall mounted fan as per original characteristics with super enameled copper wire and `E' class insulation material, replacement of the worn out bearing etc. as required i/c dismantling, making arrangment for transportation to workshop and reinstallation of the same at site, making supply connection, providing and fixing of necessary nut & bolts etc. (To be carried out as & when required). (The dismantled material will be taken by the contractor).
Testing of dielectric strength of oil of 800kVA oil type 11kV/433V transformer of 605 Ltr oil capacity, oil filtration, heating and dehumidifying of oil to achieve recommended BDV and submitting the test report .
800kVA oil type 11kV/433V transformer maintenance i/c IR checking of LV/HV windings inbetween and w.r.t. earth, Winding resistance measurement, maintenace of Buchholtz device, cleaning and painting of transformer body, tightness of terminals, simulation of Buchholtz alarm & trip, winding temperature alarm & trip, Oil temperature alarm trip etc. as applicable and as directed by E-I-C and submision of report. i. 1st year
ii. 2nd year
AMC of 415V 630A/800A/1000A/1250A/2000A L&T make Air Circuit Breaker i/c repair, attending breakdown as when required and maintenace, servicing i/c testing of protection system if applicable and as required, tripping test, cleaning, contact resistance measurement etc. as required and submission of test report. (Servicing of ACB will be done once in a year through OEM/ Authorised Dealer) i. 1st year
ii. 2nd year
iii. 1-phase, 2-wire, 230V, 5-60A, class: 1.0, Electronic, BIS certified Energy Meter
iv. 3-phase, 4-wire, 415V, 10-60A, class: 1.0, Electronic, BIS certified Energy Meter
v. 100A/5A 10VA class: 1.0 LT ring type Current Transformer
vi. 630A FP 36kA MCCB ( Thermal Magnetic release with O/L and S/C protection) Ics= 100% Icu
vii. 400A FP 36kA MCCB ( Thermal Magnetic release with O/L and S/C protection) Ics= 100% Icu
viii. Blue colored 230V ac 50Hz LED indication lamp
ix. DP 40A, residual current 100mA RCCB
ABHISHEK ASSOCIATES
Sterling And Wilson Pvt. Ltd
Techno Electricals
PAN POLAR ENGINEERS PVT. LTD.
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.42 MB
TenDocAMCas.pdf
Tender Documents • 8.61 MB
BOQ_53207.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .