Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.4 LAccepted-AOC GANDHI CHOWK LANSDOWNE DISTT PAURI GARHWAL PIN 246155 | PAURI GARHWAL | UTTARAKHAND | 246155 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹29.8 L+₹2.6 L (9.42%)Rejected-AOC 199 79 SADAR BAZAR LANSDOWNE TAHSIL LANSDOWNE | L2 | Rejected-AOC Not Lowest |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
12 Dec 2022, 6:00 pmClosed
CWE HILLS Dehradun
HQ CWE HILLS Dehradun, Mall Road, Dehradun Cantt -248003
PROVISION OF UNDERGROUND SUMP AT GBS CAMP KOTDWARA UNDER AGE I LANSDOWNE
2022_MES_530339_4
87131/LDN/E8
Open Tender
Civil Works
Lump-sum
240 days
AGE (I) Lansdowne
Class E category a (i)
8 documents required · 8 mandatory
₹500
AGE(I) Lansdowne
₹50,000
Yes
14 Jan 2023
15 Nov 2022
19 Dec 2022
15 Nov 2022
12 Dec 2022
29 Nov 2022
Amount
SCHEDULE 'A' PART-I Underground Sump - 01 : Construction of Underground Sump -90000Ltr Capacity With pump house complete all as shown on drawings.
TOTAL AMOUNT OF SCHEDULE 'A' PART-II (Road, Path and Culvert ) For details see item No 1 to 3 of Schedule A part-II in PDF Folder )
TOTAL AMOUNT OF SCHEDULE 'A' PART III (Fencing/ Gate and Compound wall ) For details see item No 1 to 18 of Schedule A part-III in PDF Folder )
TOTAL AMOUNT OF SCHEDULE 'A' PART IV-A (Internal & External Electric Supply ) For details see item No 1 to 18 of Schedule A part-IV-A in PDF Folder )
TOTAL AMOUNT OF SCHEDULE 'A' PART V (Demolition and dismantling ) For details see item No 1 to 2 of Schedule A part-V in PDF Folder )
SCHEDULE 'A' PART IV-B (Internal & EXTERNAL Electric SUPPLY)
Supply, Fix, commissioning and testing of open well submersible pumpset horizontal type, suction/ delivery -65x65mm, discharge capacity-32 Cum/Hr, 30 Mtr head, including 3-phase motor 415 V rating ISI marked capacity not less than 10 HP (7.5 KW), having impellor of cast iron and shaft of stainless steel complete, including PCC foundation complete all as specified by manufacturer, base frame and cable connection complete all as specified and as directed.
S&F water pressure guage ISI marked of range 0-5 kg/sqcm with dial size of 100 mm dia along with SS ball valve of suitable size complete including necessary arrangement for fixing on main header all as specified and directed.
M&L for design, supply, fabrication, Installation, testing and commissoning Factory made LT Panel board, indoor type totally enclosed, dust and vermin proof, suitably ventilated, Wall/ floor mounted, 415 volts, 3 phase and neutral, 50 Hz AC supply system, fully compartmentalized, both side openable, made out of 2.00 mm thick CRCA sheet, protection of enclousure IP-43 as per IS: 2147 of 1962 with pre-treatment and powder coated of approved colour including suitable frame work/support made out of suitable size angle iron/flat iron, front opening type with provision for cable entry, with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded copper conductor FRLS cable of adequate size(minimum 1.5 sqmm), including required civil works/anchoring bolts for fixing, PCC foundation etc with and including following all as specified and directed : - (a) Busbar chamber : Electrically grade shrouded aluminium bus bar of capacity 200 Amps for each phase and 100 Amps for neutral and current density 0.8A/Sqmm , including interconnection of all switch gears, fixed on DMC insulators and provision of extension :-
Notes :- 1. Panel manufacturers should have in house powder coating plant with minimum 8 tank pretreatment of MS sheet facilities, dust free spray paint booth.(8 tanks pretreatment process includes: degreasing/water rinsing/de-dusting/water rinsing/activation/phosphating water rinsing/passivation). 2. Thickness of powder coating shall not be less than 80 microns and test certificate for powder coating shall be furnished along with LT panel 3. The panel manufacturer should have following certification: (i) CPRI certification degree of protection IP-43 ( should have IEC:61439-1-2 & IEC:60529 tests) (ii) CPRI certification short circuit with stand strength should be 50 KA RMS for 1 sec with initial peak of 105 KA (iii) CPRI certification rated current for short circuit not less than 5000A 4. All the electricals switch gear like MCCBs, MCB should be of same make 5. Drawing of panel board should be got approved from GE before fabrication. 6. Panel board should be fully compartmentalized in accordance to form 4 b of IEC 61439-1-2.
S&F PVC insulated unarmoured and sheathed three core submersible flat copper conductor cable of 10 Sqmm with suitable copper terminals complete all as specified and directed.
S&F switch Modular single pole, one way 6 Amps , 1 module, 230 volts, 50 hz complete all as specified and directed.
S&F switch modular , one-way 16Amps, 1 module 240 Volts AC all as specified and directed.
S&F modular Socket outlet, 6A - 2/3 pin combined, 2 module ISI marked, 230 volts, 50 hz all as specified and directed.
S&F modular socket, 6A/16A -2/3 pin combined 2 module 230 volts, 50 hz all as specified and directed.
S&F surface mounted LED luminiare, 20 watt with all accessories having polymer extruded channel with diffuser for glare free light, high lumen output, driver PF >0.98 having over voltage protection upto 400 volts surge protection, level 7-10 KV thermal short circuit protection THD<10%, made up of long life LED chips (SMD) in modular with Ra>70 and lumen efficiency >120 lumen per watt, internally pre-wired through flexible wire connecting with ceiling rose complete all as specified and directed. Note: The firm has to give warranty for fitting including driver minimum for 2 years for any defects developed during the period.
S&F LED building security light 1 x 20 W housing made out of pressure die-cast aluminium alloy with toughned glass, IP 66 protection working on 240 volts, 50 Hz, consisting of reflecting lamps wired with appropriate driver PF> 0.98 having overvoltage protection upto 440 volt, surge protection level > 10 KV, thermal short circuit prtection THD< 10% made up of long life LED chip (SMD) in modular with Ra< 70, and LED lumen efficiency > 140 lumen per watt, beam angle along the drive way, 120 degree, beam angle across the drive way, 80 degree luminaire efficiency> 120 luminous /watt power LED should be of more than 01 watt CCT should be between 5700° K- 6500 K including fixing on suitable size bracket including making necessary electric connection with 1.5 sqmm , 3 core, PVC insulated copper onductor cable 1100 Volt grade complete all as specified and as directed. Note :- (i) The firm has to given warranty of street light fittings including driver minimum for 02 years for any defect developed during the period. (ii) The contractor Shall submit the third Party LM 79 report from any NABL approved laboratory (iii) The fiitting should have BIS , CRS No
M/S Balaji Builders
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .