Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.9 LAccepted-AOC 154 GANDHI MARKET AMBALA CANTT HARYANA 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L1 | Accepted-AOC BEING LOWEST BIDDER | |
| 2 | L2₹33.6 L+₹2.9 L (9.31%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹40.7 L+₹10.0 L (32.4%)Rejected-Finance 186 GANDHI MARKET AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹41.6 L+₹10.9 L (35.3%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
23 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF AMBALA
GE AF AMBALA
GE AF/AMB-T-19/2022-23 REPAIRS / MAINTENANCE / IMPROVEMENT TO EXTERNAL ELECTRIC DISTRIBUTION SYSTEM, CABLES, OH LINES AND CONNECTED ITEMS IN TECHNICAL AND DOMESTIC AREAS AT AF STATION AMBALA
2022_MES_533804_2
GE AF/AMB-T-19/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE AF AMBALA
ALL AS PER NIT AND TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
Yes
GE AF AMBALA
₹99,000
Yes
16 Dec 2022
22 Aug 2022
26 Sept 2022
22 Aug 2022
23 Sept 2022
10 Sept 2022
29 Aug 2022 - 2 Sept 2022
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundations, manholes, etc. or for laying cables/pipes, erecting poles, etc. not exceeding 10sqm on plan and getting out in soft / loose soil complete all as specified and as directeddisposing off complete all as specified and as directed
Returning, filling in, including, spreading, leveling, watering and well ramming in layers not exceeding 25cm deep as in any type of soil complete all as specified and as directed
Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point in any type of soil including spreading in low lying area and leveling complete all as specified and as directed
Supply and laying burnt bricks of sub-class 'B' designation 75 laid in trenches for cable protection complete all as specified and as directed
M&L for fine dry river sand cushioning by laying 8cm thick layer below the cable for making soft bed and 15cm above the cable and then punning down to its consolidated thickness of 18cm after the cable is laid all as specified in SSR Part-I complete all as specified and as directed Note: Only punned thickness of sand shall be considered for measurement purposes
M&L for plain cement concrete 1:3:6 (type C-2) using 40mm graded stone aggregate as in foundations, filling, bases of poles, post holes, etc. complete all as specified and as directed
M&L for plain cement concrete 1:2:4 (type B-1) using 20mm graded stone aggregate as in coping to poles, etc. including all necessary formwork complete all as specified and as directed
M&L for boring into roads / paths / hard standing, concrete / tiled / bituminous, etc. by trenchless / manual method, as per site requirements, for insertion of GI protection / passing through pipes 50 to 80mm bore, at any length at any location including making good the disturbed surfaces after laying of pipes complete all as specified and as directed
Providing labour, transport and requisite T&P for locating fault in LT line in OH/UG line/cable by visual inspection recce of faulty area and repairs to the fault by means of replacement of unservicible jumpers / fuse wires / burnt lugs / MCCB/ cable, etc. including restringing of broken ACSR conductors/ earth wire, etc. taking out and relaying the same after rectification of defects upto 5m length complete all as specified and as directed Notes: (i) Materials requried for fault repairs will be measured under relevant items herein in BOQ (ii) Contractor will depute the dedicated team, he will completely responsible for all the safety aspects of his team. No dispute regarding safety of person would be entertained later on and in the event of any mishappening during rectification works Contractor shall be fully liable to bear all the expenses whatsoever (iii) Maximum 10Nos. of misc complaints/petty repairs at different location will be treated as one job per day. Requisite log register shall be maintained accordingly. (iv) Contractor will provide necessary complaint slip, complaint book & permit book, for lodgging the complaints duly marked the location, time and date for earlier rectifications, signed by all concerned (v) After getting the complaints, team deployed by the Contractor will rectify the complaints within stipulated time i.e within 2hours from the time of receiving of complaints
Item No. 9 continued: (vi) Contractor shall also provide a dedicated supervisor for collection of complaints from SBA, JE, etc. in normal working hours i.e. 0900hrs to 1700hrs daily (excluding Sundays and holidays). He would be held responsible, in case complaints are not collected timely (vii) Contractor will provide all set of T&P, communication device (Mobile Phone) to deployed persons/ electrician team as required for repair of LT Electrical switch gear system including safety equipment (bamboo ladders, shorting rod, screw drivers, wire/cable cutters with blades, multi meters, cutting pliers, torch lights and rain coats, etc.) for routine maintenance and protection of the tradesmen. (viii) On intimation of any type of repair/maintenance work of LT switch gear incomer as well as out going feeder the contractor is responsible to locate the fault by the dedicated team comprising tradesman helpers required numbers as per the gravity /nature of the work involved to restore the power supply (not less than one electrician and one helper) and communicate with SBA on duty and getting permit card for working on LT lines and deposit the permit card after rectification of fault, all the activities shall be carried out within reasonable time as directed by the Engineer-in-Charge
Supply, laying, jointing, connecting and testing XLPE insulated, screened, PVC sheathed cable 1100V grade, screwed PVC bedded, armoured electric power cable, heavy duty multi-stranded aluminium conductor laid in trenches / fixed on walls/poles, passing through pipes, etc. including taking out old cables and disposing off complete all as specified and as directed of the following sizes: Note: Excavation and earthwork will be measured and paid separately under respective item herein
3.5 core 240sqmm
3.5 core 150sqmm
3.5 core 120sqmm
3.5 core 95sqmm
3.5 core 70sqmm
3.5 core 50sqmm
3.5 core 35sqmm
3.5 core 25sqmm
4 core 16sqmm
Supplying, fixing / laying steel water tubing, light grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for protection of electric clables including taking out old damaged tubing and disposing off complete all as specified and as directed for the following bores:
100mm bore
50mm bore
40mm bore
M&L for carrying out tests for locating faults in LT cable of any size with the help of fault locator machines, etc. at any locations, finding fault and repairing viz. changing the jointsetc. as required and relaying of cable complete all as specified and as directed Notes: (i) Rate shall be inclusive of all excavation, earthwork in any type of soil and making good the disturbed surfaces (ii) Cable joints will be measured and paid separately under respective items herein (iii) Testing to ensure funstionality of the line after repairs shall be done as required. Rate shall be deemed to be included in quoted rate
M&L for cable jointing kit for 1.1kV grade cable for straight through heat shrink type joint with jointing material and accessories suitable for 4 core, 25/35/50mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for cable jointing kit for 1.1kV grade cable for straight through heat shrink type joint with jointing material and accessories suitable for 3.5 core, 70/95/120/150mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for cable jointing kit for 1.1kV grade cable for straight through heat shrink type joint with jointing material and accessories suitable for 3.5 core, 185/240/300mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for cable jointing kit for 1.1kV grade cable for end termination heat shrink type joint, indoor/outdoor type with jointing material and accessories suitable for 3.5 core, 185/240/300mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for cable jointing kit for 1.1kV grade cable for end termination heat shrink type joint, indoor/outdoor type with jointing material and accessories suitable for 3.5 core, 70/95/120/150mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for cable jointing kit for 1.1kV grade cable for end termination heat shrink type joint, indoor/outdoor type with jointing material and accessories suitable for 4 core, 35/50mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for cable jointing kit for 1.1kV grade cable for end termination heat shrink type joint, outdoor type with jointing material and accessories suitable for 4 core, 16/25mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
S&F bus bar chamber, IP-42, suitable of 3 phase 433V outdoor type fabricated out of 3.15mm thick MS sheet with rated aluminium busbar 4Nos., PVC sleeves (coloured red, yellow, blue and black) with suitable locking arrangments and four legged angle iron stand made of angle iron of size 40x40x6mm duly grouted in and including foundation in PCC 1:2:4 type C1 using 20mm graded stone aggregates alongwith all necesary cable connections, lugs and cable glands including applying two coats of synthetic enamel paint (of approved tint) over a coat of red oxide zinc chrome primer complete all as specified and as directed of the following sizes and capacity:
of size 600x600x450mm with 400A busbar
of size 300x300x150mm with 100A busbar
M&L for carrying out repairs / maintenance of existing LT panels at any position / location and of any size, by disconnecting connections, etc. cleaning the entire compartments, arranging cables in proper manner, changing burnt lugs by providing new lugs, thimbles, etc., taping with insulated tapes of all naked cable joints/ends, preparation of old treated surfaces and applying one coat of grey synthetic enamel paint including all necessary welding works to reinstate broken / damaged doors, hinges, supports, legs, etc. cleaning the surrounding upto 2m all around and reconnecting the connections complete all as specified and as directed
Supply, installation, testing and commisioning CPRI approved powder coated compartmentalized LT electric control panel, cubical type, for outdoor use, double door dust & vermin proof, floor mounted made out of CRCA steel sheet of 3.15mm thick (outer parts) and 2.00mm thick (other inner parts) with angle iron legs of size 50x50x6mm having front and rear hinged doors with front openable shutters for each MCCB with spreader & extended rotary handle having hinges on one side and locating arrangements with screws type on other sides, fully enclosed bus bar chamber, having electrolytic high conductivity insulated bus bar made but of aluminium, of rating 400A for 3 phase, 415V, 50 C/S 4 wire system, with cable entry provisions, with suitable lugs, glands, voltmeter, ammeter and phase indicator, legs duly painted with two coats of stove enameled powder coated paint over a coat of red oxide primer including necessary PCC work of height 45cm from the ground level complete all as specified and as directed for the following:
Panel with the following: (i) 1000A rated aluminium bus bar 04Nos. (three phase and neutral) (ii) MCCB 3 phase adjustable type with thermal magnetic release 630A 50kA four pole -01No. (iii) MCCB 3 phase adjustable type with thermal magnetic release 400A 35kA four pole -02Nos. (iv) MCCB 3 phase adjustable type with thermal magnetic release 250A 25kA four pole -02Nos. (v) Digital Ammeter and voltmeter- 01No. (vi) LED Indicator lamp in three colour RYB - 01set of 3 (vii) Spare chamber -01No.
Panel with the following: (i) 600A rated aluminium bus bar 04Nos. (three phase and neutral) (ii) MCCB 3 phase adjustable type with thermal magnetic release 400A 35kA four pole -01No. (iii) MCCB 3 phase adjustable type with thermal magnetic release 200A 35kA four pole -02Nos. (iv) MCCB 3 phase adjustable type with thermal magnetic release 100A 16kA four pole -02Nos. (v) Digital Ammeter and voltmeter- 01No. (vi) LED Indicator lamp in three colour RYB - 01set of 3 (vii) Spare chamber -01No.
Panel with the following: (i) 600A rated aluminium bus bar 04Nos. (three phase and neutral) (ii) MCCB 3 phase adjustable type with thermal magnetic release 400A 35kA four pole -01No. (iii) MCCB 3 phase adjustable type with thermal magnetic release 160A 25kA four pole -02Nos. (iv) MCCB 3 phase adjustable type with thermal magnetic release 125A 25kA four pole -03Nos. (v) Digital Ammeter and voltmeter- 01No. (vi) LED Indicator lamp in three colour RYB - 01set of 3 (vii) Spare chamber -01No.
Panel with the following: (i) 400A rated aluminium bus bar 04Nos. (three phase and neutral) (ii) MCCB 3 phase adjustable type with thermal magnetic release 250A 35kA four pole -01No. (iii) MCCB 3 phase adjustable type with thermal magnetic release 125A 25kA four pole -03Nos. (iv) Digital Ammeter and voltmeter- 01No. (v) LED Indicator lamp in three colour RYB - 01set of 3 (vi) Spare chamber -01No.
Notes for serial item Nos. 37 to 41: (i) The location of panels / feeders shall be as directed by the Engineer-in-charge (ii) Panels shall be of make as detailed hereinafter (iii) Contractor shall submit shop drawings from CPRI approved manufactures / fabricators listed in these tender documents for approval before procurement (iv) Drawings of panels showing location of switchgears shall be got approved from the GE before incorporation at site
S&F in repairs onload change over switch 100A 4 Pole 415V 50Hz with front handle operation in sheet metal enclosure as per exising make and size complete all as specified and as directed
Supplying, fixing, connecting, testing and commissioning MCCB 63A, 4 Pole, 16kA, 415V, 50Hz rating with fixed thermal and magnetic setting including taking out old unserviceable MCCB and disposing off complete all as specified and directed
Supplying, fixing, connecting, testing and commissioning MCCB 100A, 4 pole, 16kA, 415V, 50Hz rating with fixed thermal and magnetic setting including taking out old unserviceable MCCB and disposing off complete all as specified and directed
Supplying, fixing, connecting, testing and commissioning MCCB 125A, 4 pole, 16kA, 415V, 50Hz rating with fixed thermal and magnetic setting including taking out old unserviceable MCCB and disposing off complete all as specified and directed
Supplying, fixing, connecting, testing and commissioning MCCB 160A, 4 pole, 25kA, 415V, 50Hz rating with fixed thermal and magnetic setting including taking out old unserviceable MCCB and disposing off complete all as specified and directed
Supplying, fixing, connecting, testing and commissioning MCCB 200A, 4 pole, 25kA, 415V, 50Hz rating with fixed thermal and magnetic setting including taking out old unserviceable MCCB and disposing off complete all as specified and directed
Supplying, fixing, connecting, testing and commissioning MCCB 250A, 4 pole, 25kA, 415V, 50Hz rating with fixed thermal and magnetic setting including taking out old unserviceable MCCB and disposing off complete all as specified and directed
Supplying, fixing, connecting, testing and commissioning MCCB 250A, 4 pole, 25kA, 415V, 50Hz rating with fixed thermal and magnetic setting with front operated rotary handle including taking out old unserviceable MCCB and disposing off complete all as specified and directed
Supplying, fixing, connecting, testing and commissioning MCCB 315A, 4 pole, 36kA, 415V, 50Hz rating with adjustable thermal and magnetic setting including taking out old unserviceable MCCB and disposing off complete all as specified and directed
Supplying, fixing, connecting, testing and commissioning MCCB 400A, 4 pole, 36kA, 415V, 50Hz rating with adjustable thermal and magnetic setting including taking out old unserviceable MCCB and disposing off complete all as specified and directed
Supplying, fixing, connecting, testing and commissioning MCCB 400A, 4 pole, 50kA, 415V, 50Hz rating with adjustable thermal and magnetic setting with front operated rotary handle including taking out old unserviceable MCCB and disposing off complete all as specified and directed
Supplying, fixing, connecting, testing and commissioning MCCB 630A, 4 pole, 50kA, 415V, 50Hz rating with adjustable thermal and magnetic setting including taking out old unserviceable MCCB and disposing off complete all as specified and directed
Supplying, fixing, connecting, testing and commissioning MCCB 630A, 4 pole, 50kA, 415V, 50Hz rating with adjustable thermal and magnetic setting with front operated rotary handle including taking out old unserviceable MCCB and disposing off complete all as specified and directed
S&F 10mm thick CI earth pit cover with handle, duly hinged in mild steel angle iron frame of size 300x300mm made out of MS angle iron of size 40x40x6mm thick duly fixed to existing earthing pits and entirely painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer including dismantling and taking down old pit cover and disposing off complete all as specified and as directed
M&L for test point terminal block made of gun metal phosphorus bronze, size 75x75x25mm, drilled and screwed with sheet metal enclosure of size 100x100x100mm fabricated out of steel sheet not less than 1.6mm thick and including 3Nos. 8mm dia 25mm long hexagonal head screws, taking down and disposing off old unserviceable block complete all as specified and as directed
S&F in repairs air termination, single pointed aluminium rod 12mm dia and 300mm long including suitable insulated base plate and connecting up complete all as specified and as directed
M&L for brazing / welding works on joints of any type of earth strip complete all as specified and as directed
Supply only lugs for UG cable 2.5/4 core 16sqmm to 150sqmm complete all as specified
S&F copper strip of size 20x3.15mm with saddles and fixing screws, FRP insulators, etc. for roof conductors, earth continuity conductors, down conductors and wall conductors above the ground, etc. brazed/welded at each joint complete all as specified and as directed
S&F in repairs GI strip of size 32x6mm with saddles and fixing screws, FRP insulators, etc. for roof conductors, down conductors and wall conductors above the ground, etc. brazed/welded at each joint complete all as specified and as directed
S&F in repairs aluminium strip of size 25x3.15mm with saddles and fixing screws, FRP insulators, etc. for roof conductors, down conductors and wall conductors above the ground, etc. brazed/welded at each joint complete all as specified and as directed
S&F PVC / porcelain insulators fixed on walls, etc. complete all as specified and as directed
M&L for taking down carefully existing steel tubular electric poles after proper shutting down of supply, etc. from any location, and erecting the same in position in other location including providing new MS base plate of size 300x300x6mm duly welded at bottom, cap, finial taper plugs, bolts, nuts, screws, etc. (rate shall be included) complete all as specified and as directed Notes: (i) Excavation / earthwork and PCC foundation, coping etc. will be measured and paid separately under respective items herein (ii) Locations for taking down & refixing poles will be at any position within the Station premises (iii) Cost of all loading, unloading, carting, etc. as required at site from old location to new location shall be deemed to be included in the quoted rate (iv) Poles shall be painted with two coats of bituminous paint (both internally and externally) for the embedded portions and with two coats of aluminium paint over a coat of red oxide primer for the balance exposed portions
M&L for preparation of surfaces viz. scrapping old paints, smoothening, etc. and painting to steel poles 9/11m high/long with two coats of synthetic enamel paint over a coat of red oxide primer, in blue & white alternate stipes (in 30cm height 5 blocks of each AF pattern) and top red stripe, upto a height of 1.5m from ground, including painting of pole coping with synthetic enamel paint (black tint) and writing (font 1/2"x3") pole numbers with white synthetic enamel paint on circular base, marking of HT/LT, painting of cross arms, brackets with two coats of aluminum paint over a coat of red oxide primer complete all as specified all as directed
M&L for preparation of surfaces viz. scrapping old paints, smoothening, etc. and painting to PCC poles 9/11m high /long with two coats of acrylic paint over a coat of wall primer, in blue & white alternate stipes (in 30cm height 5 blocks of each AF pattern) and top red stripe, upto a height of 1.5m from ground, including painting of pole coping with synthetic enamel paint (black tint) and writing (font 1/2"x3") pole numbers with white synthetic enamel paint on circular base, marking of HT/LT, painting of cross arms, brackets with two coats of aluminum paint over a coat of red oxide primer with all necessary staging, safety precautions, etc. as required complete all as specified all as directed
S&F in repairs PVC line separator for LT OH line suitable for 3 phase and neutral of capacity 1100V complete all as specified and as directed
M&L in repairs for cross arms, bracings, supports clamps, and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated and inclusive of one primer coat, one under coat and one finishing coat of good quality of aluminium paint all as specified and as directed
M&L in repairs for stringing of aluminum conductor steel reinforced (ACSR), weasel type, stringing properly on insulators and binding with aluminum binding wire, jumpers, etc. complete all as specified and as directed
M&L for re-stringing ACSR conductor, straightening properly on insulators and binding with aluminum tape /binding wire/conductor, jumper, etc. complete all as specified and as directed
S&F pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, 02Nos. galvanised iron washers and 01No. galvanised iron nut, 100mm height 65mm dia for 1100V grade complete all as specified and as directed
M&L for cutting, trimming, dressing, etc. to remove manually or mechanically vegetative growth viz. grass, shrubs, plants, etc. around installations, premises, boundary walls, electric poles, etc. and removing the rubbish to a suitable place at a distance not exceeding 50m complete all as specified and as directed
M&L for cutting / trimming / prunning branches of trees, exceeding 1inch and not exceeding 2inch dia, falling over HT lines, cutting to make minimum distance of 2m from OH lines of any type span of any length in 2/4/6 way conductor system, including all neceessary safety precautions, shutting of supply, staging, barricading, roping down the cut branches, suitable cutters, etc. and disposing off the cut branches to a suitable place at a distance not exceeding 50m complete all as specified and as directed Note: All branches cut, as required at site and as directed, in each tree shall be measured as one unit
S&F lightening arrestor, expulsion type, 65kA discharge capacity transmission class, suitable for 11kV system, non-linear resistor type, horn gap and chocking coil, with all fittings for outdoor use, including staging as required including taking down and disposing off old arrestor complete all as specified and as directed
S&F 20mm dia ERW steel conduit with proper clamping for streetlight box to street light fitting including taking down of old conduit and disposing off complete all as specified and directed
M&L for preparation of surfaces viz. scrapping old paints, smoothening, etc. and painting to concrete surfaces of earthing pit walls, etc. with two coats of synthetic enamel paint (of approved tint) complete all as specified all as directed
M&L for preventive maintenance to functional earthing GI/Cu/ Chemical (any type), by mechanically checking earth resistance value and bringing up the same to required state by developing and adding new chemical mixture of sodium carbonate, magnesium sulphate, common salt, charcoal, etc. and ensuring required earth resistance value on completion including all necessary excavation/earthwork complete all as specified and as directed
M&L for earthing using GI earthing with galvanised steel earth plate electode 600x600x6mm thick buried directly in ground, earth pit not less than 2.25m deep below ground level connection to and including GI strip of size 32x6mm extended to 7.5m as earth lead by means of GI bolts, nuts, etc. with provision of charcoal and salt all as per electrical plate No. 3 of SSR Part-I including water arrangement with GI pipe 40mm dia (light grade), earth lead protection GI pipe 20mm medium grade with bends, elbow, etc. from earth plate to test point, excavation and earthwork in any type of soil, returning, filling, ramming and removing of soil to distance not exceeding 50m, make good to match with existing surface making PCC pit (earth chamber) having internal size 300x300x300mm and outer size 600x 600x600mm with RCC reinforced cover 50mm thick and testing on completion including making test points on wall as per SSR specifications, taking down and disposing off old earthing complete all as specified and as directed
Notes for serial item No. 79: (i) The cost of GI earth continuity wire / strip with GI pipe 40mm light grade upto 7.5m is deemed to be included (ii) The earth chamber to be constructed 0.5m from edge of earth pit with necessary watering arrangement. The cost for the same is deemed to be included in above item (iii) Earthing shall produce desired earth resistance values as directed by the Engineer-in-charge
CHAUHAN ENTERPRISES
M/S Sonu Traders
R D Bansal
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .