| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.9 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹6.5 L+₹1.4 L (26.7%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹6.5 L+₹1.4 L (27.3%)Rejected-Finance | L3 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
15 Sept 2023, 6:00 pmClosed
Major S N Gaikwad
Holta Cantt, Palampur
REPAIR MAINTENANCE OF INTERNAL WIRING MCBs DBs SUB MAIN WIRING AND ELECTRICAL FITTINGS IN CENTRAL INSTITUTE AND FLAG STAFF HOUSE AT ALHILAL MIL STN
2023_MES_614134_1
GEP-43/2023-24
Open Tender
Civil Works
Item Rate
180 days
Alhilal Mil Stn
As per tender documents
8 documents required · 8 mandatory
₹500
GE Palampur
₹20,000
28 Nov 2023
17 Aug 2023
18 Sept 2023
17 Aug 2023
15 Sept 2023
1 Sept 2023
Amount
Taking down carefully copper / aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls,floors, etc, complete all as specified and directed.
M&L for point wiring for one light/fan/call bell point controlled by one 5/6 Amp switch with 1.5 Sqmm two single core multistranded copper conductor FRLSH, PVC insulated (unsheathed) heavy duty cable 1100 volts including continuous earth wire of size 1.5 Sqmm copper conductor multistrand FRLSH, PVC insulated (unsheathed) drawn into concealed rigid non-metallic PVC conduit Med Grade ISI marked not less than 20mm wide of 1.8mm wall thickness ISI marked including modular GI sunken flush box (Modular GI sunken flush boxese of any way i.e. 1 to 8 way as per site requirement) for mounting switches, sockets, fan regulators etc & making good to disturbed surfaces as well as matching with existing whitewash colour/surface complete all as specified and as directed for the following:- (a) Wiring shall be done by using proper colour coding (b) Earth wire shall be of green colour (c) On RCC roof/ceiling PVC conduit shall be provided on surface with proper fixing clamps all as directed. Note: Modular white cover plate with frame shall be measured and paid separately.
All as per the description of serial item No 2 here-in-before but one 5 pin socket outlet, 5 amps on the same board complete all as specified and directed.
All as per the description of Serial item No. 2 above but one 5 pin socket outlet, 5/6 Amp on independent board complete all as specified and directed.
All as per the description of Serial Item No. 2 above but for 16 Amps socket point on independent board with 2.5 Sqmm PVC insulated FRLS-H multi-stranded copper conductor with 2.5 Sqmm PVC insulated FRLS-H multi-stranded copper conductor as earth wire,complete all as specified and directed.
S&F modular switch 1 way 6A, 1 module complete all as specified and directed.
S&F modular switch 1 way 16A, 1 module complete all as specified and directed.
S&F modular socket, 6A-2/3 pin combined 2 module complete all as specified and directed.
S&F modular socket, 6A and 16A, 2/3 pin combined 2 module complete all as specified and directed.
S&F fan step regulator 120W-2 Module complete all as specified and directed.
S&F white cover plate with frame, 1 module complete all as specified and directed.
S&F white cover plate with frame, 2 module complete all as specified and directed.
S&F white cover plate with frame, 3 module complete all as specified and directed.
S&F white cover plate with frame, 4 module complete all as specified and directed.
S&F white cover plate with frame, 6 module complete all as specified and directed.
S&F white cover plate with frame, 8 module complete all as specified and directed.
S&F ding dong bell musical type AC 230 volt single pole complete all as specified and directed.
S&F modular bell push 5/6A switch 1 module, complete all as specified and directed.
M&L point wiring using approved colour coding as per IS (Red , Black and Green for single phase circuits),with multi stranded copper conductor 1.5 sq mm nominal cross-sectional area , two single core, PVC insulated and unsheathed FRLS-H cable 1100 Volts grade, ISI-694 marked with valid CML No.in and including concealed PVC rigid conduit not less than 20mm wide, ISI marked with accessories on wall/roof/floor etc, ISI marked with mild steel/pressed steel sunken box duly painted with two coats of anti corrosive paint/aiuminium paint over a coat of red oxide primer internally and two coats of black bituminous paint over a coat of red oxide primer externally,covered with 3 mm thick plastic laminated sheet cover for fixing of switches, socket and fan regulators etc, including PVC insulated multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLS-H cable as earth continuity conductor for one light/ fan/bell point controlled by one switch & making good to distubed surfaces as well as matching with existing whitewash colour/surface complete all as specified and directed.
All as per the description of serial item No. 19 above but one 5 pin socket outlet, 5/6 Amp on the same board complete all as specified and directed.
All as per the description of serial item No. 19 above but one 5 pin socket outlet, 5/6 Amp on independent board complete all as specified and directed.
All as per the description of serial item No. 19 above but for 16 Amps socket point on independent board with 2.5 Sqmm PVC insulated FRLS-H multi-stranded copper conductor with 2.5 Sqmm PVC insulated FRLS-H multi-stranded copper conductor as earth wire & making good to disturbed surfaces as well as matching with existing whitewash colour/surface complete all as specified and directed.
All as per item No. 19 above but one two way point controlled by 2 way switch 5 amps.
S&F switch piano 6 Amp flush type single pole two way with ISI marked,complete all as specified and directed.
S&F switch piano 6 Amp flush type single pole one way with ISI marked,complete all as specified and directed.
S&F socket outlets 2-in-1, 3 pin 6 Amp flush type, complete all as specified and directed.
S&F socket outlets 16 Amps, 3 pin flush type, complete all as specified and directed.
S&F switch piano 16 Amp flush type single pole one way with ISI marked,complete all as specified and directed.
S&F ceiling rose, 3 phase / PVC / Polycarbonate, isolated body complete all as specified and directed.
S&F lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
S&F bell Push flush type 5A switch, complete all as specified and directed.
S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet suitable for 240 volts AC 100 watt etc complete all as specified and directed.
S&F LED bulb of 9 watt complete all as specified and directed.
S&F LED light fitting mirror type with high out put diffuser 10 watt 220 v AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F LED complete fitting including batten & T-8 Retro LED polycarbonate 1 x 20 watt tuberod, appx 4 feet long, environment firendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed. Make: Bajaj Cat Part No. for batten BLRB-DB118 and Cat Part No. for tube rod BLRB20WLED/Havells Cat Part No. for batten STREAKNEOT8UPTO1X22wSSBSWH Cat part of tube rod TITANIAEO1213T8SSTL20WLED865SPC/Polycab Cat Part No for batten PID0502001/Cat Part tube rod LTU0101009P
S&F environmental friendly, ultra modern, energy saving, surface mounted, decorative bulk head fitting LED luminaire comprising of high brightness LEDs 10 watt, IP66 protection class complete all as specified and directed. Make: Havells Cat Part No. RUGBYGENXFTS10WLED865SSYMBOPC/Bajaj Cat Part No. BIBWP 10W LED WH/Philips Cat Part No. WT202WLED 10S
S&F factory made DB TPN 4 way double door with suitable size of copper bus bar concealed in wall IP 43 protection,415 V,3 phase 50 Hz for fixing MCB & making good to disturbed surfaces as well as matching with existing whitewash colour/surface complete all as specified and directed. Note:- Distribution board and MCB's should be same make.
S&F factory made DB SPN 12 way double door with 200 Amps rated bus bar concealed in wall IP42/ 43 protection,240V for fixing MCB & making good to disturbed surfaces as well as matching with existing whitewash colour/surface complete all as specified and directed. Note:- Distribution board and MCB's should be same make.
S&F factory made DB SPN 8 way double door with 200 Amps rated bus bar concealed in wall IP 42/43 protection,240V for fixing MCB & making good to disturbed surfaces as well as matching with existing whitewash colour/surface complete all as specified and directed. Note:- Distribution board and MCB's should be same make.
S&F factory made DB SPN 4 way double door with 200 Amps rated bus bar concealed in wall IP 42/43 protection,240V for fixing MCB & making good to disturbed surfaces as well as matching with existing whitewash colour/surface complete all as specified and directed. Note:- Distribution board and MCB's should be same make.
S&F MCB SP ‘B’ curve, 10KA, 240V, 6 to 32 amps, in the MCB DB including necessary connection complete all as specified and directed.
S&F MCB SPN ‘C’ curve, 10KA, 240V, 32 amps, in the MCB DB including necessary connection complete all as specified and directed.
S&F MCB SPN ‘C’ curve, 10KA, 240V, 40 to 63 amps in the MCB DB including necessary connection complete all as specified and directed.
S&F MCB TPN ‘B’ curve, 10KA, 415V, 63 amps in the MCB DB including necessary connection complete all as specified and directed.
M&L sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS-H, cable of 2 run 6 Sq mm for phase and neutral and one run of 6 Sq mm for earth wire unsheathed, multistranded, copper conductor FRLS-H, cable drawn through non metallic rigid PVC conduit not less than 20mm dia ISI marked including all conduit and fixing accessories complete. Two runs of cable for phase/neutral, one run of cable for earth and one run PVC conduit will be measured and paid as one unit length complete all as specified and directed. Note:- Wiring shall be done in proper colour coding.
M&L sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS-H, cable of 2 run 4 Sq mm for phase and neutral and one run of 4 Sq mm for earth wire unsheathed, multistranded, copper conductor FRLS-H, cable drawn through non metallic rigid PVC conduit not less than 20mm dia ISI marked including all conduit and fixing accessories complete. Two runs of cable for phase/neutral, one run of cable for earth and one run PVC conduit will be measured and paid as one unit length complete all as specified and directed. Note:- Wiring shall be done in proper colour coding.
Taking down the sub main wiring of any size from the wall/roof/ceiling and removing from the site and making good disturbed surface complete all as specified and directed.
Taking down main switches, distribution board, steel enclosure with MCB's any way and rating including wooden board or from steel board and making good distubed surfaces complete all as specified and directed.
S&F in repair switch piano 6 Amp flush type single pole one way with ISI marked,complete all as specified and directed.
S&F in repair socket outlets 2-in-1, 3 pin 6 Amp flush type, complete all as specified and directed.
S&F in repair bell Push flush type 5A switch, complete all as specified and directed.
S&F in repair switch piano 16 Amp flush type single pole one way with ISI marked,complete all as specified and directed.
S&F in repairs switch socket combination 2 in 1, 5/3 pin, 6 and 16 Amp flush type universal, ISI marked complete all as specified and directed.
S&F in repairs socket outlets 2-in-1, 5 pin 6 and 16 Amp flush type, complete all as specified and directed.
S&F in repairs stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc complete all as specified and directed.
S&F in repairs ding dong bell musical type AC 230 volt single pole complete all as specified and directed.
S&F in repairs capacitor 2.50 Mfd, 240V, complete all as specified and directed.
S&F in repairs MCB SPN ‘C’ curve, 10KA 32 amps complete all as specified and directed.
S&F in repairs MCB SP ‘B’ curve, 10KA 6 to 32 amps complete all as specified and directed.
S&F in repairs MCB TPN ‘B’ curve, 10KA, 415V, 63 amps in the MCB DB including necessary connection complete all as specified and directed.
S&F in repairs Hylem sheet 3mm thick of size 9" x 11" including cutting of sheet for fixing switch/socket complete all as specified and directed.
S&F in repairs Hylem sheet 3mm thick of size 8" x 5" including cutting of sheet for fixing switch/socket complete all as specified and directed.
S&F in repairs Hylem sheet 3mm thick of size 4" x 4" including cutting of sheet for fixing switch/socket complete all as specified and directed.
S&F in replacement of PVC non metallic casing caping of 25mm size with accessories including dismantling/taking down of old unserviceable/broken PVC conduit/casing caping fixed on surface/concealed including making good the disturbed surface complete all as specified and directed.
S&F in replacement PVC flexible pipe 25mm ISI marked complete all as specified and directed.
S&F in repairs environmental friendly, ultra modern, energy saving, surface mounted, decorative bulk head fitting LED luminaire comprising of high brightness LEDs 10 watt, IP66 protection class complete all as specified and directed. Make Havells Cat Part No. RUGBYGENXFTS10WLED865SSYMBOPC/ Bajaj Cat Part No. BIBWP 10W LED WH/Philips Cat Part No. WT202WLED 10S
S&F light fitting pre wired suitable for single T8 LED tube along with fitting of nominal wattage - 18 watt, Lumen out put- 2100 Lm, Colour Temp- 6500 Kelvin, Size & length- G13/T8/4 Feet, having short circuit and surge protection including making connection with two core PVC insulated, sheathed copper conductor cable of size 23/0.0076 complete all as specified and as directed.
S&F in repairs surface mounting 2 ft length, 10/12 watt LED batten with light fitting complete all as specified and directed. Make: Havells Cat Part No. LUMILINEPLUSBS10WLED865SPCWH/ Bajaj Cat Part No. BCLSB10W WH/Philips Cat part No. BN021LED125 6500K/4000k PSU
S&F in repairs 4ft length ultra bright 20W LED polycarbonate tube rod with THD<10% with very high efficacy suited for installation in existing T8 fitting with G13 lamp holders (single side connection) complete all as specified and directed. Make: Havells Cart Part No. PHOTONULTRA2.01213T8SSTL20WLED865SPC or equivalent in Crompton Greaves /Bajaj/Philips/Wipro as approved by GE.
S&F in repairs LED light fitting 1 x 36/33 Watt, 2ft x 2ft ceiling surface type environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to light fitting, complete fitting and all accessories with following specifications and all as directed. Note: Contractor is responsible for making necessary arrangements such as Scaffolding of suitable size for fixing of ceiling lights at different height and location at site. The rate for making arrangement of Scaffolding and manpower required for the above work is deemed to be included in the quoted rate. Make: Havells Cat Part No. PLANO2x2PLR36WLED840S/Bajaj Cat part No. BZRSQL 36W LED GX WH/Philips Cat part No. RC375B LED 865/840 PSU W60L60 52WH
S&F in repairs electronic meters temper proof LCD display with polycarbonate cover Single Phase 230V, 10-60A accuracy class-I 50 Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage & KWH complete all as specified and directed.
S&F in repairs electronic meters temper proof LCD display with polycarbonate cover Three Phase 415V 10-60A accuracy class-I 50 Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage & KWH complete all as specified and directed.
S&F in repairs 3 pin plug top 16 Amp, complete all as specified and directed. Make: Crabtree/Havells/Anchor/SSK
S&F in repairs switch socket combination 20A unit box 2 fixing holes complete all as specified and directed.
S&F in repairs switch socket combination 6A unit box 2 fixing holes complete all as specified and directed.
M&L disconnecting taking down and stacking the unsv/broken AI/GI strip of any size from the roof or from wall and removing the same from the site complete all as specified and directed.
S&F air termination vertical type, single pointed made with 12mm dia 300mm long aluminium rod including necessary fixing arrangements with aluminium bolts, nuts, lead washers, etc. complete and incl provision of GI tubing light grade 40mm dia, 300mm long embedded in PCC block (size 30cm x 30cm x 30cm) one end and other end fitted with air termination rod complete all as specified and directed.
Test point terminal block made out and gun metal or phosphorus bronze of size 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25mm long hex head screw for fixing the same on wall complete all as specified and directed.
S&F galvanized iron strip of size 32x6mm from earth pit to test point provided all around the bldg for lightening protection laid in trenches/fixed to walls on epoxy insulators with bolts, check nuts etc and connecting up complete all as specified and directed.
S&F horizontal/down conductors, aluminium strip of size 25x3.15mm and incl epoxy insulator bus bar type 40mm thick at an interval of 60cm apart for lightening protection on roof and for down conductors, including all fixing arrangements and aluminium nuts, bolts & washers complete all as per IS-2309-1989 and testing complete all as specified and directed.
S&F in repairs LED driver suitable for light fitting 1x36watt, 4 ft x 1 ft, ceiling surface type environment friendly, including connection to ceiling light complete all as specified and directed. Note: Contractor is responsible for making necessary arrangements such as Scaffolding of suitable size for fixing of LED driver to ceiling light at different height and location at site. The rate of making arrangment of Scaffolding and manpower required for the above work is deemed to be included in the quoted rates.
S&F factory made CRCA sheet powder coated double door panel board, 2mm thick, suitable size, wall mounted type partially grouted in wall and with locking arrangement, handle and including provn of the followings and connection all as specified and directed:- (a) MCB TPN 63A, 415 volts, C Series-01 Nos (Incoming) (b) MCB, SPN, 6-32 Amp, 230 volts- 05 Nos (outgoing for each qtr & 1 common stair case light point (c) Fixing only existing energy meter of old DB- 04 Nos
M&L earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead strip 32mm x 6mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth strip protected by galvanized iron 40 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc including taking out old un-serviceable earthing, complete all as directed.
Note:-(i) The concrete pit shall be of PCC 1:3:6 type C-1, 40mm thick pre-cast cover slab of RCC (1:2:4) type B-1 using 20mm graded crushed stone aggregate, reinforced with 8mm TMT bars @ 10 cm c/c on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No. 3 of MES SSR Part-I. (ii) Item includes the cost of GI pipe up to 7.5m GI for protection of earth strip. (iii) PCC pit shall be provided at least 500mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate
M/S Bharmouri Construction
M/S MALHI CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .