Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.7 LAccepted-AOC | ₹30.7 L | L1 | Accepted-AOC Awarded |
| 2 | L2₹31 LRejected-AOC GANAKPARA CITY TOWN UDALGURI P O BHOLABARI P S KALAIGAON DIST UDALGURI ASSAM PIN 784525 | DARRANG | ASSAM | 784525 | ₹31 L | L2 | Rejected-AOC Not awarded |
| 3 | L3₹31.1 LRejected-AOC VILL SINGIMARI PO KALAIGAON DIST UDALGURI ASSAM | ₹31.1 L | L3 | Rejected-AOC Not awarded |
| Sl No | Description | Qty | Unit | LANKESWAR RABHA L2 | RANJIT BORO L3 | SS Enterprise L1 |
|---|---|---|---|---|---|---|
| 1.00 | Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. (i) Private Land | 252.62 | Cum | 255 ₹64,418.61 | 250 ₹63,155.50 | 250 ₹63,155.50 |
| 2.00 | Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801
ii) 600mm equilateral Traingle | 1 | Each | 6,836.89 ₹6,836.89 | 5,000 ₹5,000 | 5,770.35 ₹5,770.35 |
| 3.00 | (iii) 600 mm circular. | 1 | Each | 5,401.6 ₹5,401.60 | 5,401.6 ₹5,401.60 | 7,500 ₹7,500 |
| 4.00 | Providing and laying of boulder apron laid in wire crates with 4 mm dia GI wire conforming to IS:280 and IS:4826 in 100 mm x 100 mm mesh (woven diagonally) including 10 per cent extra for laps and joints laid with stone boulders weighing not less than 25 kg each as per drawing and technical specifications Clause 1301 | 25.92 | Cum | 3,000 ₹77,760 | 3,000 ₹77,760 | 3,000 ₹77,760 |
| 5.00 | RCC SLAB CULVERT 8.00 M SPAN :
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of side. I Ordinary Soil. | 466.51 | Cum | 200 ₹93,302.40 | 200 ₹93,302.40 | 200 ₹93,302.40 |
| 6.00 | Providing concrete for Plain/reinforced cement concrete in open foundation complete as per drawings and technical specification Clauses 802, 803,1202 and 1203
A. Crushed Stone II. PCC Grade M 10 (i) Nominal Mix (1:3:6) | 30.5 | Cum | 5,500 ₹1.7 L | 5,500 ₹1.7 L | 5,500 ₹1.7 L |
| 7.00 | Plain/reinforced cement concrete in open foundation complete as per drawings and technical specification Clauses 802, 803, 1202 and 1203
A. PCC Grade M 15 (i) Nominal Mix (1 : 2.5 : 5) | 140.87 | Cum | 6,000 ₹8.5 L | 6,000 ₹8.5 L | 5,875 ₹8.3 L |
| 8.00 | Plain/reinforced cement concrete in Sub-Structure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 and 1204
A. PCC Grade M 15 (i) Nominal Mix (1 : 2.5 : 5) | 141.87 | Cum | 6,000 ₹8.5 L | 6,000 ₹8.5 L | 6,000 ₹8.5 L |
| 9.00 | Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX or equivalent)) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202 | 1.6 | t | 78,000 ₹1.3 L | 78,000 ₹1.3 L | 75,000 ₹1.2 L |
| 10.00 | Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar . (Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX or equivalent)) in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202 | 3.12 | t | 78,000 ₹2.4 L | 78,000 ₹2.4 L | 75,000 ₹2.3 L |
Tender Value
₹31.0 L
EMD Value
₹62,000
Closing Date
27 Jan 2026, 1:00 pmClosed
Superintending Engineer,PWD,Kokrajhar (R/B) Circle
O/o S.E., PWD, Kokrajhar (R/B) Circle, Kokrajhar
Recovery and Restoration of Jalukbari to Banderi road (construction of 8.00m clear span RCC slab culvert) under NDRF(PDNA-2022) in Udalguri District for the year 2025-26.
2026_BoTC_50028_19
SE(R/B)/20-21/Pt-III/15
Open Tender
Civil Works – Roads
90 days
Udalguri dist
Please refer Tender documents.
4 documents required · 4 mandatory
₹700
₹62,000
Yes
5 May 2026
7 Jan 2026
27 Jan 2026
7 Jan 2026
27 Jan 2026
7 Jan 2026
7 Jan 2026 - 16 Jan 2026
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. (i) Private Land
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 ii) 600mm equilateral Traingle
(iii) 600 mm circular.
Providing and laying of boulder apron laid in wire crates with 4 mm dia GI wire conforming to IS:280 and IS:4826 in 100 mm x 100 mm mesh (woven diagonally) including 10 per cent extra for laps and joints laid with stone boulders weighing not less than 25 kg each as per drawing and technical specifications Clause 1301
RCC SLAB CULVERT 8.00 M SPAN : Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of side. I Ordinary Soil.
Providing concrete for Plain/reinforced cement concrete in open foundation complete as per drawings and technical specification Clauses 802, 803,1202 and 1203 A. Crushed Stone II. PCC Grade M 10 (i) Nominal Mix (1:3:6)
Plain/reinforced cement concrete in open foundation complete as per drawings and technical specification Clauses 802, 803, 1202 and 1203 A. PCC Grade M 15 (i) Nominal Mix (1 : 2.5 : 5)
Plain/reinforced cement concrete in Sub-Structure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 and 1204 A. PCC Grade M 15 (i) Nominal Mix (1 : 2.5 : 5)
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX or equivalent)) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar . (Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX or equivalent)) in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 A. With Crushed Stone I. RCC Grade M 20 (i) For Nominal Mix (1 : 2 : 4)
Providing and laying cement concrete wearing course M 30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3 A With crushed stone
Drainage spouts complete as per drawing and technical specifications Clause 1209
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
Providing and fixing in position pipe railing consisting of IS Rolled steel joist posts designation IS MB 100 (100x75) at 2.5 m interval and three rows of 50 mm dia steel pipes (light) including fixing in position on bridge deck complete as per drawing and technical specifications Clause 1208.2
Providing and fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing and technical specifications
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 (i) Granular Material
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.49 MB
Tendernotice_2.pdf
PDF • 11.54 MB
Tendernotice_3.pdf
PDF • 0.26 MB
BOQ_79642.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid