Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹353.3 CrAccepted-AOC A 177 OKHLA INDUSTRIAL AREA PHASE I NEW DELHI 110020 | NEW DELHI | SOUTH EAST DELHI | DELHI | 110020 | ₹353.3 Cr | L-1 | Accepted-AOC Work awarded on 03.08.2018 |
| 2 | L-2₹359.8 CrRejected-Finance | ₹359.8 Cr | L-2 | Rejected-Finance Not L-1 bidder |
| 3 | L-3₹371.5 CrRejected-Finance NCC HOUSE MADHAPUR HYDERABAD 500081 TELANGANA INDIA TELEPHONE 040 23268730 | ₹371.5 Cr | L-3 | Rejected-Finance Not L-1 bidder |
| 4 | L-4₹379.5 CrRejected-Finance GODREJ WATERSIDE TOWER NO 1 OFFICE 803 8TH FLOOR PLOT NO 5 BLOCK DP SECTOR V SALT LAKE CITY KOLKATA 700091 | KOLKATA | KOLKATA | WEST BENGAL | 700091 | ₹379.5 Cr | L-4 | Rejected-Finance Not L-1 bidder |
| 5 | L-5₹382.7 CrRejected-Finance CIGNUS 14TH 15TH FLOOR PLOT NO 71A KAILASH NAGAR MAYUR NAGAR PASSPOLI POWAI MUMBAI MAHARASHTRA INDIA | MUMBAI | MUMBAI | MAHARASHTRA | 400087 | ₹382.7 Cr | L-5 | Rejected-Finance Not L-1 bidder |
Tender Value
₹344.8 Cr
EMD Value
₹3.7 Cr
Closing Date
23 Apr 2018, 6:00 pmClosed
Sr. Manager(Engg.-Civil)
Airports Authority of India, O/o Executive Director (Engg.)-NR, Corporate Head Quarters, B-Block, 3rd Floor, Rajiv Gandhi Bhawan, Safdarjung Airport, New Delhi-110 003
Construction of Domestic Passenger Terminal Building at Dehradun Airport
2018_AAI_8196_1
AAI/CHQ/Engg(C)/DHDN/NITB
Open Tender
Construction Works
760 days
Dehradun
As per NIT
19 documents required · 19 mandatory
₹11,800
Airports Authority of India
₹3.7 Cr
6 Jul 2022
28 Feb 2018
27 Apr 2018
28 Feb 2018
23 Apr 2018
9 Apr 2018
28 Feb 2018 - 17 Mar 2018
Amount
Carriage of Earth By Mechanical Transport including loading ,unloading and stacking for all lift and lead of 3km
Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge: All kinds of soil.
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. Note;- Filling of available excavated earth shall be done after properly segregating boulders and stones. and only available excavated Earth of approved specifications shall be used for backfilling. Additional efforts for segregating boulders,seiving or seperating earth from excavated earth shall be included in the item rate and no extra payment shall be done towards the same.
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil
Supplying and filling in plinth with sand under floor, including watering ramming consolided and dressing complete
Surface dressing of the ground including removing vegetation and in- equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. Aall kind of soil
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size).
"1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size).
1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size)
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification.
Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Centering and shuttering including strutting, propping etc. and removal of form for :
Foundations, footings, bases of columns, etc. for mass concrete
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Suspended floors, roofs, landings, balconies and access platform
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Columns, Pillars, Piers, Abutments, Posts and Struts
Edges of slabs and breaks in floors and walls Under 20 cm wide
Steel reinforcement for R.C.C. work ready to use "cut and bend" rebars of approved make from factory/workshop to construction site including placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C. work ready to use "cut and bend" rebars of approved make from factory/workshop to construction site including placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500 D or more.
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately). Note1 : Agency may use RMC (Ready Mixed Concrete) instead of design mix with prior approval of engineer incharge.Nothing extra shall be payable on this account. Note 2 :- For the purpose of tendering, the quantity of cement to be used may be assumed as 330.0 Kg/cum of finished concrete for M-25 grade mix. In case, cement content as worked out by mix design formula varies from above, the necessary adjustment (plus or minus) in the rate of these item will be made on the basis of base price of cement as per schedule 'F' or purchase price of cement whichever is lower) at site plus water charges @1% and contractor's profit and overheads @ 15%.
All works up to Plinth level.
All works above plinth level & up to floor V level.
Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable /recoverable separately. Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/ cum) Note:- For the purpose of tendering, the quantity of cement to be used may be assumed as 340.0 Kg/cum of finished concrete for M-30 grade mix. In case, cement content as worked out by mix design formula varies from above, the necessary adjustment (plus or minus) in the rate of these item will be made on the basis of base price of cement as per schedule 'F' or purchase price of cement whichever is lower) at site plus water charges @1% and contractor's profit and overheads @ 15%.
Providing and fixing parallel threaded couplers conforming to IS code on “Reinforcement Couplers for Mechanical Splices of Bars for Concrete Reinforcement - Specification”, to reinforcement bars including threading, enlargement at connection by forging, protecting the prepared reinforcement bars and related operations as required to complete the works as per direction of Engineer-in-Charge.
Coupler for 16 mm diameter reinforcement bar
Coupler for 20 mm diameter reinforcement bar
Coupler for 25 mm diameter reinforcement bar
Coupler for 28 mm diameter reinforcement bar
Coupler for 32 mm diameter reinforcement bar
Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical locations in load application areas that accommodates multi directional seismic movement without stress to it's components. System shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in- Charge. (Material shall conform to ASTM 6063). Floor Joint of 150 mm gap
Providing and fixing of expansion joint system related with wall joint (internal/ external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall conform to ASTM 6063.) Wall Joint of 150 mm gap
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with clay flyash F.P.S. (non modular) brick of class designation 7.5 in superstructure above plinth level up to floor five level in : Cement mortar 1:6 (1 cement : 6 coarse sand)
Half brick masonry with non modular fly ash bricks of class designation 10, conforming to IS :12894, in super structure above plinth and upto floor V level. Cement mortar 1 : 4 (1 cement : 4 coarse sand)
Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineerin- Charge. (The payment of RCC band and reinforcement shall be made for seperately).
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry
Stone tile work for wall lining upto 10 m height with special adhesive over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement with an admixture of pigment to match the stone shade. 8mm thick (mirror polished and machine cut edge) Granite stone of any colour and shade
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any Colour and Shade. Area of slab over 0.50 Sqm
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work
Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete.
Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite stone of Approved shade
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye ,Rolite brown,River white, Valley white or equivalent.
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building, all complete as per the architectural drawings, with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand), laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye, Rolite brown,River white, Valley white or equivalent.
Providing and fixing 18 mm thick machine cut, mirror Polished granite stone Work for Wall lining( Venner work) including risers of steps, skirting and dados, in required design and pattern, size, approved shade, colour and texture laid on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with white cement slurry @ 3.3 kg/sqm i/c pointing with white cement slurry admixed with pigment of matching shade , including rubbing, curing and polishing etc. all complete as per architectural drawings and as directed by the Engineer-in-charge. (Sample of granite stone shall be approved by Engineer-in-Charge). Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye,Rolite brown,River white, Valley white or equivalent. or equivalent.
Providing and fixing machine cut, mirror/ eggshell polished , Marble stone work for wall lining (veneer work) including dado, skirting, risers of steps etc., in required design and pattern wherever required, stones of different finished surface texture, on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) laid and jointed with white cement slurry @ 3.3 kg/Sqm including pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing, polishing etc. all complete as per Architectural drawings, and as directed by the Engineer-in-Charge. 18 mm thick Italian Marble stone slab, Perlato, Rosso verona, Fire Red or Dark Emperadore etc.
Providing and laying machine cut, mirror polished Marble stone flooring, in required design (Simple geometrical, abstract etc.) and in patterns in combination with Italian marble stones of different colours, shades and finished surface texture etc., in linear portions of the building, all complete as per the architectural drawings, with 18 mm thick stone slab laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with white cement slurry @ 4.4 kg/sqm including pointing with white cement slurry admixed with pigment to match the marble shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 18 mm thick Italian Marble stone slab, Perlato, Rosso verona, Fire Red or Dark Emperadore etc.
Extra for providing and applying minimum two coats of Ferrocrete/MYKLaticrete/STP Sealer or approved equivalent on the back surface and sides (Raw Surface) of the Granite/Marble with a brush or roller to act as a barrier coat against stains, discoloration and effloroscence including cleaning the surface with brush or roller, mopping with moist cloth and allowing it to dry before application all complete as per direction of Engineer-in-charge. Note : Granite/Marble stone flooring shall be paid for separately under respective item.
Extra for providing and applying minimum two coats of Ferrocrete/MYKLeticrete/STP Impregnator sealer or approved equivalent with a brush / roller on the top surface (polished surface) of the Granite/marble to act as a barrier coat against stains, soling, discoloration and effloroscence including cleaning the surface with brush or roller, mopping with moist cloth and allowing it to dry before application all complete as per direction of Engineer-in-charge. Note : Granite/Marble stone flooring shall be paid for separately under respective item.
Extra for protecting the Finished surface of Vitrified/Ceramic/Granite/Marble/ Flooring with foam sheet having thickness 5 mm of Floor Guard or equivelant make as per manufacturers specifications / details till commissioning as per the direction of Engineer in charge.
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). Second class teak wood
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): Rectangular or Square.
Extra if louvers (not exceeding 0.2 sqm) are provided in flush door shutters (overall area of door shutters to be measured) Decorative type door
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.0 mm thick
Melamine polishing on wood work (one or more coat).
Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 gms/ sqm(both side inclusive), consisting of floor and ceiling channel 50mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture's specification and direction of engineer in charge all complete.
75 mm overall thickness partition with 12.5 mm thick double skin fire rated board conforming to IS: 2095: part I
75mm overall thickness partition with 12.5 mm thick double skin tapered edged plain Gypsum board conforming to IS: 2095: part I
66 mm overall thickness partition using 8 mm thick double skin multipurpose cement bonded wood particle board manufactured as per IS: 14276 with suitable cement bonded board screws.
Providing and fixing of hollow metal fire rated doors as per IS 3614 & BS 476 part 20 & 22 for stability and integrity. Pressed Galvanized steel conforming to IS 277 with the following specification. Recommended fire door shall have doors tested at CBRI or internationally accredited laboratory for maximum rating of 2 hours with vision panel. Test certificates should be available for vision lites/panels as part of the fire door assembly. Independent glass test certificates will not be accepted. Manufacturer test certificates shall cover doors both single and double leaf and all doors supplied should be within tested specimen, deviation in specification and sheet thickness other than what is mentioned it the test certificates are not allowed. Proper label conforming the type of door and the hourly rating is mandatory. Door frame shall be single rebate grooved frame profile of size 125 x 60 mm made out of 1.60 mm (16 gauge) minimum thick galvanized steel sheet. Frames shall be mitered and field assembled with self tabs groved frame shall have provision for inbuild thermo plastic elastomer dry flex gasket. All provision should be mortised, drilled and tappedfor receiving appropriate hardware. frames should be provided with back plate bracket and achor fastners for installation on a finishede plastered masony wall opening. once frame installed should be grouted with fire rated PUF necessary for fire doors on the clear masonry opening. Door leaf shall be 47mm thick fully flush double skin door withoyut vision lite. Door leaf shall be manufactured from 1.2mm (18 guage) minimum thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be resin bonded honeycomb core. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks and door closers. The edges should be inerlocked with lock seam. For pair of doors integral astragals shall be provided as required. Vision lie wherever applicable should be 6mm thick clear borosilicate fire rated glass of shott make relavant rating of the door. All hardwares also should be same fire rating of doors. All doors and frames shall be furnished to "PURE POLYSTER POWDER COATING" FOR MINIMUM" for minimum 50 microns (on the visible surface of the shutter and frame) of approved colour. The door leaf and frame shall have passed minimum 500 hours of salt spray test.
Single leaf door with 200x300 vision panel along with fire rated all hardware includings panic bar and trim
Double leaf door with 200x300 vision panel on both shutter along with fire rated all hardware includings panic bar and trim
Single leaf door with 200x300 vision panel along with fire rated all hardware includings mortise sash lock etc
Double leaf door with 200x300 vision panel on both shutter along with fire rated all hardware includings mortise sash lock etc
Providing and fixing set of Stainless steel 304 grade L-shape Mortise Lever Door Handle and Narrow Style Mortice lock in Stainless steel satin finish grade 304 with one side key operation and other side thumb turn operation along with strike plate, front plate, cylinder, keys, necessary screws, etc complete with oval / round rosettes and escutcheon of approved make complete to the satisfaction of Engineer-in-charge.
Providing and fixing Stainless steel 304 grade Pull Handle 300 -350mm long, 22-25 mm dia suitable for wooden doors of approved make with necessary screws etc complete to the satisfaction of Engineer-in-charge. The pull handles should have supporting washer with raised bevelling on the outer surface.
Providing and fixing slimline aluminium extruded section body tubular type universal hydraulic door closer (door weight upto 80 kg) of approved make with double speed adjustment with necessary accessoriesand screws etc. complete to the satisfaction of Engineer-in-charge.
Providing and fixing stainless steel 304 grade half dome type floor door stopper of approved make with necessary screws etc. complete to the satisfaction of Engineer-in-charge.
Providing and fixing 304 grade stainless steel tower bolts of approved make with necessary screws etc. complete to the satisfaction of Engineer-in-Charge : 250 mm x10 mm
Providing and fixing stainless steel 304 grade Matt finish Corner Patch Lock with cylinderof approved make with necessary screws etc. complete for frameless glass door to the satisfaction of Engineer-in-Charge.
Providing & fixing of modular toilet cubicles (Sturdo Classique-Evergreen series of Greenlam Industries or Titan 12 mm Box-up series of Merino or T-Line or approved equivalent) consisting of high pressure 12 mm thick compact laminated board as per IS 2046 (Indian Standards) and as per fire retardant BS-476/97 standards with phenolic core panels for partitions of intermediate divider, doors and pilasters (. The cubicle shall have dimensions of 1550 mm depth x 1000 mm width x 2100 mm height with a door size of minimum 600 mm(W) x 1905mm(H), head rail on top of panels and panels shall be fixed on the floor with a clearance of maximum 150 mm using stainless steel satin finish adjustable legs screwed to the floor.) including providing and finishing stainless steel (SS) lock set, SS door knob, SS gravity self closing hinge, SS coat hook with door stopper, SS U channel, SS head rail, SS adjustable foot, SS tabular holder, SS head rail wall bracket, SS head rail corner connection and SS noise reducing tape, etc.(all SS accessories shall be of Grade 304) as per direction of Engineer-Incharge.
Providing & fixing Urinal Modesty Panels made of 12 mm thick compact laminated board (Greenlam Sturdo UMP model A of Greenlam Industries Ltd / UMP SS Series of Merino Industries or approved equivalent make ) of approved texture/shade having standard dimension of 1200 mm Height x 450 -500 mm Width and made as per IS 2046 (Indian Standard) and as per fire retardant BS-476/97 standard and should be heat, bacteria, water, chemical, scratch and impact resistant . The product should have Green Guard Certificate. Including all accessories as per approval and direction of Engineer-in-Charge .Modesty panels will be fixed to the wall at an height of 500-600mm from the floor with 304 garde SS right angle bracket, 304 grade SS Screws with satin finish & Wall Plugs . The work includes all accessories, machineries, tools etc., complete as per direction of Engineer-in-charge.
Providing and Fixing of Slim Glass internal partition using 12 mm Toughened Glass ( Saint giobain/AASHI or equivalent )and Aluminium profiles of DORMA Alexa System-45 Frames or approved equivalent to a height of maximum 3m as per the technical specification/Drawings and as per direction of Engineer-In -Charge. The Fixed glass to be fixed using DORMA Alexa BP45 Profiles or equivelent at Top & Bottom & fixed frame cleat. The profile size shall be 45x25MM to be fixed on to the floor/ ceiling as per the requirements and the H Junction profile to be used at all Glass to Glass vertical joints and 90 degree L /T Junction profiles at required necessary areas as per design. The Glass overall panel will be as per the technical specification/Drawings.The profile shall be made of 2 mm Gauge thick matt natural anodized Aluminium and having Minimum anodic coating 20 miicron .The item includes all material like Aluminium profiles, Glass, all the necessary clips, seals, fixing accessories for the system and labour for fixing etc. .Noting shall be paid extra.
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately).
Supply & Installation of Translucent glass film (3M/Avery Dennison or equivelent make) Frosted/Dusted effect with approved artwork, cut using digital plotter. Self-adhesive, bubble-free installation on clean glass in partitions, doors, windows etc.( Installation is to be done by Authorized Installers only.)
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Note;- 1.) Structural steel for this project comprises of entire superstructure of Airport Terminal Building which is a prestigeous and architecturally designed building. Thus steel involves Architecturally Exposed Structural Steel which shall be detailed and fabricated as per International norms of AESS. No extra payment towards the same shall be made and shall be included in the rate. 2.) Structural steel for this project involves fabrication and erectionof large span girders up to 12M, large span girders, Virandeel girders at roof level of span even more than 24M at 20M height. This will involve special cranes,erection equipments, planning, erection methodology. Contractor to study all such requirements and provide for the same. Rates shall be inclusive of all such special erection efforts and no extra payment shall be made towards the same. 3.) Contractor shall prepare fabrication and erection drawings for entire structural steel preparing using 3D based software such as Tekla Structures or equivalent.
Extra for using HSFG Bolts conforming to IS1367, IS3757, of grade 8.8 in place of bolts of grade 4.6, wherever required. Bolts shall be installed and tightened by torque wrench conforming to IS4000. Rate shall be inclusive of sample testing and establishing the torque required, applying masking tape on the laying surfaces at all HSFG bolt joints which shall not be painted. All complete as per drawings, specifications and as directed by Engineer-Incharge ( Only weigth of Bolts and Nut will be measured).
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Note;- 1.) Structural steel for this project comprises of entire superstructure of Airport Terminal Building which is a prestigeous and architecturally designed building. Thus steel involves Architecturally Exposed Structural Steel which shall be detailed and fabricated as per International norms of AESS. No extra payment towards the same shall be made and shall be included in the rate. 2.) Structural steel for this project involves fabrication and erectionof large span girders up to 12M, large span girders, Virandeel girders at roof level of span even more than 24M at 20M height. This will involve special cranes,erection equipments, planning, erection methodology. Contractor to study all such requirements and provide for the same. Rates shall be inclusive of all such special erection efforts and no extra payment shall be made towards the same. 3.) Contractor shall prepare fabrication and erection drawings for entire structural steel preparing using 3D based software such as Tekla Structures or equivalent.
Extra for using Structural Steel conforming to IS2062 of minimum Yield Strength of Fy= 350 MPa Grade B0 in place of Fy=250MPa ,wherever required all complete as per drawings, specifications and as directed by Engineer-Incharge. ( Only weigth of Structural steel except bolt & nut will be measured)
Structural steel work riveted, bolted or welded in insert plates,angle etc.including cutting, hoisting, fixing in position all complete as per direction of Engineer In Charge.
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angles 40x40x6 mm for diagonal braces
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover
Providing and fixing ball bearing for rolling shutters.
Extra for providing mechanical device chain and crank operation for operating rolling shutters. Exceeding 10.00 sqm and upto 16.80 sqm in the area
Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer-in- charge, (area of grill to be measured).
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile B Fixing with adjustable lugs with split end tail to each jamb
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Electric resistance welding (ERW)/High frequency induction welding (HFIW) MS tube thickness upto 10mm, ISI marked from SAIL/RINL/TATA/JINDAL or approved equivalent make conforming to IS1161/4923, grade of steel YST310/355 in the profile shaped as per drawings with special plate connectors, pinion joints, plates, hollow sections etc using SAW/MMAW/MIG welding process with special plate connectors, pinion joints, plates, hollow sections etc and including transportation, cutting, threading, machining, leads and lifts upto all heights, tools and plants and necessary scaffolding etc required for all operations involved to make structure of terminal building. All complete as per direction of engineer in charge. Note;- 1.) Structural steel for this project comprises of entire superstructure of Airport Terminal Building which is a prestigeous and architecturally designed building. Thus steel involves Architecturally Exposed Structural Steel which shall be detailed and fabricated as per International norms of AESS. No extra payment towards the same shall be made and shall be included in the rate. 2.) Structural steel for this project involves fabrication and erectionof large span girders up to 12M, large span girders, Virandeel girders at roof level of span even more than 24M at 20M height. This will involve special cranes,erection equipments, planning, erection methodology. Contractor to study all such requirements and provide for the same. Rates shall be inclusive of all such special erection efforts and no extra payment shall be made towards the same. 3.) Contractor shall prepare fabrication and erection drawings for entire structural steel preparing using 3D based software such as Tekla Structures or equivalent.
Providing and fixing mild steel round holding down bolts with nuts and washer plates complete.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. Note;- 1.) Structural steel for this project comprises of entire superstructure of Airport Terminal Building which is a prestigeous and architecturally designed building. Thus steel involves Architecturally Exposed Structural Steel which shall be detailed and fabricated as per International norms of AESS. No extra payment towards the same shall be made and shall be included in the rate. 2.) Structural steel for this project involves fabrication and erectionof large span girders up to 12M, large span girders, Virandeel girders at roof level of span even more than 24M at 20M height. This will involve special cranes,erection equipments, planning, erection methodology. Contractor to study all such requirements and provide for the same. Rates shall be inclusive of all such special erection efforts and no extra payment shall be made towards the same. 3.) Contractor shall prepare fabrication and erection drawings for entire structural steel preparing using 3D based software such as Tekla Structures or equivalent.
In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Providing and installing Hot dipped galvanised steel deckspans – 0.9 mm thk - Providing and installing Hot dipped galvanised steel deckspans – 0.9 mm thk, Grade 350, TR 60+ of approved make including cutting to required shape, lapping, fixing to supporting structural members as per manufacturers specifications including welding of shear stud connection to main structural steel members through deck sheets at specified locations and level for receiving reinforced concrete or screed complete. Including flashings, end trims, closure pieces, slabs, stopper blocks, etc. Rate shall include temporary supports wherever required. Rate shall be inclusive of supplying and installing headed high strength (fy=350mpa) shear studs of 19mm dia and 95 to 120mm length, puddle welded to supporting steel beam through deck sheet using stud installing gun all complete as per specifications, drawings and as directed by Engineer Incharge.
Providing supplying and installing stainless steel high strength tension bar / compression strut system including design. Conforming to Eurocode 3 (EN 1993-1-1) for suspender system of large cantilever canopies, cross bracings, wind bracings etc including all accessaries such as Fork ends, clevises, Couplers, Turnbuckles, anchor discs etc installed as per manufacturers specifications, with guaranteed load capacities, load testing stainless steel with min fy 460 N/mm2, manufacturers certificate etc complete as per direction of EIC.
Supply & installation of AISI 304 grade satin finish floor mounted guard railing comprises of 54x12mm thk. baluster welded to a SS circular base plate of Ø97x8mm thk.(AISI 304) and anchored with 3 nos. of M8 CSK anchors (GI) at maximum spacing of 1250mm. Handrail of Ø42.4x2mm thk.welded on the top of the baluster at maximum railing height of 250mm from FFL with necessary bends & joints etc. complete. as per direction of Engineer Incharge.
Fabrication, Supply and installation of Light Bollard Conforming Grade to SS-304, Mattfinish), BOLLARD with tappered top, Height-900mm, Diameter -150mm, Base plate dia –210mm.)etc Complete of approved make as per technical specification and direction of Engineer Incharge.
Supply & Installation of AISI 304 grade satin finish floor mounted handrail system of approved make comprises of 54x12mm thk. baluster with Ø115x8mm thk. (AISI 304) base plate welded at bottom and anchored with 3 Nos. of M8x105 mm long mechanical anchors on the top of RCC slab / treads, covered by Ø118x18x1mm thk. AISI 304 rosette cover. The maximum spacing of balusters will be 1200mm. Handrail of Ø42.4x2mm thk. will be mounted on the baluster with unified handrail bracket at a railing height of 1100mm from FFL for staircase & Atruium /cutouts respectively. 12.89mm thk. (6mm+0.89SGP+6mm ) toughened laminated glass mounted on the baluster with thru hole fixation using glass adaptors with necessary rubber beading, washers etc complete as per direction of Engineer Incharge.
62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 gradedstone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete
Providing and fixing glass strips in joints of terrazo / cement concrete floors. 40 mm wide and 4 mm thick.
Cement plaster skirting (upto 30 cm height) with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement 18 mm thick
Providing and laying Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand.) 25 mm thick
Providing and laying Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete
Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab.
Extra for Kota stone/ sand stone in treads of steps and risers using single length up to 1.05 metre.
Providing & fixing at site 18 mm thick of approved make or equivalent pre finished hard wood flooring with 7 coats of UV lacquer of panel size 120mm x 900 mm (approx.) laid directly on existing IPS flooring as a floating floor inclusive of 2mm PE foam & ployethelene sheet complete in all respects as per direction & satisfaction of Engineer in charge. Pre finished and pre treated solid Asian Teak.
Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm
Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, Dado, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 600x600 mm
Providing and fixing Glass mossaic tiles on finished plain wall surface of size 20 mm x 20 mm x 4 mm in all colour, design , fixing in customize design as per direction of Engineer-in- Charge. The glass mosaic tiles to be fixed on the wall surface with the help of approved adhesive applied at the rate of 2.5 kg per sqm and grouting of the same. The rate is inclusive of all operation, material and required pattern approved by Engineer-in-Charge:
Providing and fixing 10x10x7.50 cm Granite stone block hand cut and chisel dressed on top, for paving in floors, drains etc. laid over 20mm thick base mortar 1:4 (1 cement : 4 coarse sand) with joints 10mm wide filled with same mortar including ruled pointing etc. complete as per direction of engineer-in-charge.
Providing and fixing removable raised/false access flooring with system and its components of approved make for different plenum height with possible height adjustment upto 50 mm, comprising of modular load bearing floor panels supported on G.I. rectangular stinger frame work and G.I. Pedestal etc. all complete, as per the architectural drawings, as specified and as directed by Engineer-in-charge consisting of: a) Providing at required spacing to form modular framework, pedestals made out of GI tube of thickness minimum 2 mm and 25 mm outer diameter, fully welded on to the G.I. Base plate of size 100mm x 100mm x 3mm at the bottom of the pedestal tube, G.I. pedestal head of size 75mmx75mmx3.5 mm welded with GI fully threaded stud 16mm outer diameter with two GI Check nuts screwed on the stud for level adjustment upto 50mm, locking and stabilizing the pedestal head in position at the required level. The pedestals shall be fixed to the subfloor (base) through base plate using epoxy based adhesive of approved make or the machine screw with rawl plug. b) Stringers system in all steel construction hot dipped galvanized of rectangular size 570x20x30x0.80mm thick having holes at both ends for securing the stringers on to the pedestal head using fully threaded screws ensuring maximum lateral stability in all directions, the grid formed by the pedestal and stringer assembly shall receive the floor panel, this system shall provide adequate solid, rigid support for access floor panel, the system shall provide a minimum clear uninterrupted clearance between the bottom of the floor for electrical conduits and wiring etc. all complete as per the architectural drawings, as specified and as directed by the Engineer-in-charge.
Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having water absorption less than 0.5% and conforming to IS: 15622, of approved make in all colours and shades in outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.
Providing and Laying Teracotta Vitrified Tile of size 30 X 30 cm for flooring laid on a bed of cement mortar 1:4, filling joints with white cement slurry with matching pigments, curing, and cleaning etc, complete without boarder/ with border with pattern of cement tiles of approved colour as per direction of Engineer-in-Charge.
Providing and laying Carpet of Woven Axminster -Ax 1228 A or approved equivalent of thickness 10.3mm, Weight of 2559 g/m2 with Pile Yarn (80% wool 20% Nylon), with Backing material of Polyster , Polypropylene, latex.The construction Details with Yarn count R674/2, Pitch of 27.6 Per dm, Rows -47.2 Per DM, The carpet with Turf Density of 1303 per dm2. The pile height above back with 1315g/m2 and total pile weight 1754 g/m2. The colour compling ISO I05-B02, Turf Ancourage as per ISO 4919, flamability classification as per ISO 9239. The rate shall be inclusive of all operation, material, fixing in required pattern imported specialised adhesive, overheads etc. complete. as per direction of Engineer-in-Charge.
Providing and fixing 5 mm thick Aluminium anodized profile skirting of 75 mm wide with approved finish in skirting for Granite,carpet and vitrified flooring areas . The skirting should be equally spaced as directed by engineer incharge.The cost includes with all acessories, coupler,corners,dry wall screws,Installation Fixing with Screw Corner guards & Caping Strip Soft Rubber Colour Vibrant colours of Skirting will be matched with same colour Corner guard and PVC Caping Strip etc complete.as directed by Engineer- in-charge.
Proiving and fixing 300mm high Stainless steel skirting of 304 grade, 1 mm thick over 12mm Fire rated plywood backing and necessary MS subframe red oxide coated complete with necessary hardware , buffing, polishing complete as per technical specification and direction of Engineer-in-Charge.
WT-10 DOUBLE SKIN ALUMINIUM INSULATED STANDING SEAM ROOFING SYSTEM Supply and fixing of 65/400- Self Supported concealed Fix STANDING ROOFING SYSTEM in 0.9mm thick in AA 3004 Aluminium Alloy comprising of the following layers: For designing wind load calculation shall be as per IS :875, pull out strength of fastners and sound transmission class (STC) report from reputed NABL accredited lab for the roofing system to be submitted to Engineer - In -charge. i. Exterior Layer – Top layer – 65/400 Straight/Tapered/Curved profiled sheeting manufactured from Aluminum Alloy Almnlmg1- as specified in BS EN 1396 (comparable AA 3004), minimum material thickness of 0.9 mm and 25micron PVDF2 finish. The material properties are as follows:- Ultimate tensile strength: minimum 200 N/mm2 0.2% Proof Stress: minimum 185 N/mm2 Modulus of elasticity:70,000 N/mm2 The fluorocarbon coating (2-coat system) shall consist of:- First coat -Inhibitive primer, with a dry film thickness averaging 5-7 micron Second coat-Fluorocarbon colour coat, with a minimum dry film thickness of 20 microns. The inner side of the panels shall be finished with primer coating of 5-7 microns. Accessories: Aluminum ST clips – in grade 6061- T6 , of suitable height, with spacing as required for the wind loads thus resulting in an overall “Self-supporting standing seam roof system”.Detailed structural calculations shall be provided by the manufacturer for the Clip Pull out force. Each aluminum clip shall come with a 5mm height black polyamide thermal barrier pad. Other relevant accessories like, Ridge closures, gable end channels, tolerance clips, gable end clips, foam fillers etc to be included as appropriate and wherever necessary. Corrugation cavities shall be closed off from the outside and inside of the building to ensure a tight fit leaving no gaps. ii. Insulation layer – Rockwool Insulation of overall thickness 150 mm and density 64 kg/m3. K-value 0.038 W/mK as per standard ASTM C-518. Fire classification as per BS 476: Part 6&7 / EN-1350-1 / UL-273.
ALUMNIUM FLASHINGS Supply & Fixing of 0.90 mm thick Aluminium Flashing in the same PVDF finish as of Roof panels as per specification of item Aluminium standing roof system and as per direction of engineer in-charge.
INSULATED ALUMINIUM GUTTERS Supply and fixing of 2 mm thick Alumnium gutters up to 1800mm Girth along with 100 mm thick insulation of 120 kg/m3 density, VCL , GI Z-Girts and 0.5 mm thck Precoated and Galvalume Liner. The Gutter will also have aluminium Expansion joints fixed at every 12 mtrs and aluminium spouts at every Grid location. All joints of gutters shall have aluminium welding. all complete as per direction by engineer in-charge.
ROOF HATCH SYSTEM Roof Hatch - Single Leaf Ideal for applications requiring roof access • Size : 900mm x 900mm Material : Shall have aluminium cover and frame of 11 gauge (2.3mm) Cover: Shall have breakformed, hollow-metal design with 1" (25.4mm) concealed fiberglass insulation, 3" (76mm) beaded, overlapping flange, fully welded at corners, and internally reinforced for 40 psf (195 kg/m2) live load Curb: Shall be 12" (305mm) in height with integral capflashing, 1" (25.4mm) fiberboard insulation, fully welded at corners, and 3-1/2" (89mm) mounting flange with 7/16" holes (11mm) provided for securing frame to the roof dec Gasket: Shall have extruded EPDM rubber gasket permanently adhered to cover Hinges: Shall have heavy-duty pintle hinges with 3/8" (9mm) type 316 stainless steel hinge pins. Latch: Single leaf: Shall have slam latch with interior and exterior turn handles and padlock hasps. Lift Assistance: Compression spring operators shall be enclosed in telescopic tubes. Shall have automatic hold-open arm with grip handle release Hardware: Shall have Aluminium engineered composite compression spring tubes. Shall have steel compression springs with electro coated acrylic finish. Shall have type 316 Stainless steel hinges.All other hardware shall be zinc plated/chromate sealed Finish: Shall have aluminum: Mill Finish. All complete as per direction by engineer incharge
WALKSAFE SYSTEM Supply and fixing of WALKSAFE SYSTEM The specification of the system is as mentioned below: FRP Pultruded Grating Manufactured From 'I' Section 25 mm Height with Bearing Bar C/c 40mm,& Cross Bar of 12mm Dia Round Bar,C/C 150mm Manufactured From Isophthalic Resin. Colour---Grey/Yellow Width of Walkway--- 490 mm Walk-Safe System Accessories: Seam clip made of Aluminium Alloy 6063/T5 Temper mill finished and will be as per BSEN755-2 specifications Aluminium L-Angle made of Aluminium Alloy 6063/T6 Temper mill finished and will be as per BS EN 755-2 specifications Fasteners of Stainless Steel Grade 304.All complete as per direction by engineer incharge.
Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening“for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/ opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection > 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity <0.043 w/mK.
Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ?85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm ) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6)
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with onnecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to all/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :
12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- Part I
12.5 mm thick tapered edge gypsum moisture resistant board
Providing and fixing torsion spring Plank Ceiling System Hunter Douglas or Equivalent make of approved finish comprising of Plank of 600mm wide and 1200mm long manufactured out of 0.9mm thick Aluminium Alloy 3105 perforated 1.5mm dia With 22% open area. The metal ceiling panels shall be downward accessible with a minimum of four (4) torsion springs per panel.The Plank will be manufactured on advanced CAD/CAM equipment that includes several levelling stages in the manufacturing process.Torsion Spring panel with two side legs die formed and two end legs die formed and punched to receive torsion springs (min two springs each end or side) for secure engagement into Tee Grid main runners which are factory punched to receive torsion springs. Planks will be square edged. The metal ceiling panels shall be downward accessible with a minimum of four (4) torsion springs per panel. The Plank shall be Polyester powder coated in desired colour.All complete as per drawings, specification and direction of the Engineer in Charge. All Ceiling products shall adhere to Green Pro Certification. Main Runners: 24mm deep, inverted “Tee” sections, 3.6m long, with factory punched flanges to receive torsion spring assembly. Main Tee on centre spacing to match panel length. Cross Runners: 24 mm deep, inverted “Tee” sections designed to interlock in to web of main tee section on designated spacing. Cross tee length to match panel length. Cross tees are spaced spacing 1200mm on centre maximum. Suspension System: As per manufacturer standard considering type of plenum and its height. Paint finish – The panels will be pre treated in latest nano technology process and electro statically powder coated with automatic Carona system and cured with gas catalytic technology. Acoustic Felt (Optional): Non-woven felt made of glass-reinforced fibre glued over the perforation for sound absorption. NRC- 0.7
Wood finish
white finish
Providing and fixing unperforated corrosion resistant Aluminium Magnesium alloy lineal metal panel ceiling system by Hunter Douglas or Equivalent of approved wood Finish colour consisting of panel 180mm wide x 15mm deep x 0.6mm thick with square edges, panel length up to 6 mtrs, Coil Coated on a Continuous Paint Line, Double baked and roll formed from doubled baked enameled corrosion resistance aluminium magnesium alloy for higher strength and good roll forming characteristics. Panel shall be clipped to a baked enameled aluminium panel carrier of 62mm wide x 29mm deep made of 0.90 mm thick in standard length of 5 mtrs made of doubled enameled aluminium magnesium alloy black with cut outs to hold the panels in a module of 200 mm and at a distance 1.45 mtrs without insulation. The carrier shall be suspended by means of G.I suspension rod 4mm diameter and a Galvanized suspension spring clip at a distance of 1.7mtrs centre to centre.All complete as per drawings, specification and direction of the Engineer in Charge. All Ceiling products shall adhere to Green Pro Certification Paint finish: Aluminium panels shall be chromatised for maximum bond between metal and paint enamelled twice under high temperature, one side with full primer and finish coat, the other side (inner side) with a primer coating and skin coat on a Continuous Paint Line. Mode of Measurements: Measurements shall be wall to wall without any deductions for lights, diffusers, columns etc. Wood finish
Providing and fixing Baffle Aluminium panel ceiling manufactured by Hunter Douglas or equivqlent of approved colour consisting of panel size 150 mm deep X 50 mm width using 0.7mm thick, panel length upto 4 mtr, Powder Coated, Double baked and roll formed from enamelled corrosion resistance Aluminium alloy AA 3105 (Al. Mg) for higher strength and good roll forming characteristics. Panels shall be connected using friction grip upper and lower bracket on a special carrier of 30 mm wide x 30 mm high x 2 mm thick powder coated GI member to form as cassette based on the 150mm module, which shall be downward accessible with a minimum of four (4) torsion springs in group of panel. Main Runners: 24mm deep, inverted “Tee” sections, 3.6m long, with factory punched flanges to receive torsion spring assembly. Main Tee on centre spacing to match panel length. Cross Runners: 24 mm deep, inverted “Tee” sections designed to interlock in to web of main tee section on designated spacing. Cross tee length to match panel length. Cross tees are spaced spacing 1200mm on centre maximum. Suspension System : The complete frame to be suspended using special bracket with M6 threaded rod. Paint Finish: Aluminium panels shall be chromatised for maximum bond between metal and paint enamelled twice under high temperature, both sides with a full primer and finish coat on a Continuous Paint Line. Ceiling Finish above U Baffle Ceiling : ceiling area above U Baffle to be painted in black colour if required before fixing. The ceiling system should br all complete as per direction of E-I-C.
12 mm cement plaster of mix 1:6 (1 cement: 6 fine sand)
15 mm cement plaster on the rough side of singleor half brick wall of mix : (b) 1:6 (1 cement: 6 fine sand)
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge.
Providing and applying 12 mm thick (average) premixed formulated one coat gypsum lightweight plaster having additives and light weight aggregates as vermiculite/ perlite respectively conforming to IS: 2547 (Part - 1 & II) 1976, applied on hacked / uneven background such as bare brick/ block/ RCC work on walls & ceiling at all floors and locations, finished in smooth line and level etc. complete.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
6 mm plaster on cement concrete or reinforced cement concrete work with white cement based polymer modified self curing mortar of approved make as per the direction of Engineer-In-Charge.
Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two Coats
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two Coats
Finishing walls with textured exterior paint of required shade New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.
With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre
With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
Extra for priming with ready mixed red oxide zinc chromatic primer on steel / iron works having VOC content less than 250 grams/litre over priming coat included in the items of steel work.
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.
On Steel Work
On concrete Work
Painting with synthetic enamel paint, having VOC (Volatile Organic Compound) content less than 150 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two Coats
Supplying and applying water based Fire intumescent paint fire tested in accordance with BS 476 Parts 20‐22 as approved make @ DFT dependent on HP/a ratio of structural steel with zinc phosphate primer to give additional anti‐corrosive protection having VS of 73% ‐ 83% as approved applied over abrasive blasted surface and surface preparation up to a standard of Sa2.5 (ISO 8501‐1:1988) or SSPC‐SP6 at 75 micron and LEED V4 Compliant for VOC Content and VOC Emissions polyurethane finish paint as approved having volume solid of 72% ‐ 73% @ 50 micron of the required shade over Structural Steel Works at all levels including storage, surface preparation by sand blasting, degreasing, cleaning, drying, providing temporary staging, scaffolding, testing etc., all complete with all respect as desired and as per manufacturer specification and direction of Engineer in charge. The above products should confirm to Green Building norms. Application to be carried out by authorized manufacturer applicator or any other trained applicator as approved by the manufacturer and direction of Engineer in charge.
Consolidation of sub grade with power road roller of 8 to 12 tonne capacity including making good the undulations etc. with available earth or quarry spoiles etc. complete as per direction of Engineer- incharge.
Dry stone pitching 22.5 cm thick including supply of stones and preparing surface complete.
Supplying and fixing turn buckles and straining bolts for barbed wire fencing.
Providing and laying in position Polysulphide sealant of approved make conforming to BS-5212-1990 or IS: 11433-1995. in expansion including rounding off edges, applying 2 coats of approved primer compatible with the brand of Polysulphide and preparing the surface and applying masking tape along the edge of joint to prevent accidental spillage of sealant on top surface and to give neat finish to the sealant and removing the masking tape after application of sealant etc. complete as per direction of Engineer in-Charge & particular specifications. Expansion Joints of size 25 mm wide and 10 mm deep over 30 mm dia closed-cell Polyethylene foam back-up rod. [Note: For purpose of payment, quantity (Length x Width x Depth) of Polysulphide sealant only will be measured.]
Providing and fixing Glow studs of size 100x20 mm made of heavy duty body shall be moulded ASA (Acrylic styrene Acryloretrite ) or HIP (High impact polystyrene) or ABS having electronically welded micro- prismatic lens with abrasion resistant coating as approved by Engineer in charge. The glow stud shall support a load of 13635 kg tested in accordance with ASTM D4280. The slope of retro- reflective surface shall be 35 (+/-5) degress to base .The reflective panels on both sides with at least 12 cm of reflective area up each side. The luminance intensity should be as per the specification and shall be tested as described in ASTM I: 809 as recommended in BS: 873 part 4 : 1973. The studs shall be fixed to the Road surface using the adhesive conforming to IS, as per procedure recommended by the manufacturer complete and as per direction of Engineer-in-charge.
Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4 m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately)
Providing and applying 2.5 mm thick road marking strips (retro- reflective) of specified shade/ colour using hot thermoplastic material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, T&P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete as per direction of Engineer-in-charge and accordance with applicable specifications
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand) including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
Providing and fixing post delineators made of ABS round body fitted with 2 nos 100 mm dia high reflective reflectors and mounted on MS pipe of 65 mm dia duly powder coated anti-rust and anti theft steel to be installed as per direction of Engineer-incharge.
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material, by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30
Construction of dry lean cement concrete sub base over a prepared sub-grade with coarse and fine aggregate conforming to IS:383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per specifications, cement content not to be less than 150 Kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, for all leads & lifts, laid with a mechanical paver, compacting with 8-10 tonne vibratory roller, finishing and curing etc. complete as per direction of Engineer-in- charge.
Providing and laying factory made chamfered edge Cement Concrete paver blocks, in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern.
Providing and laying Pavement Quality Concrete having a minimum work test beam flexural strength of 4.1 MPa at 28 days using not less than 350 Kg of ordinary Portland Cement of 43 grade conforming to IS: 8112 per cum of concrete, coarse sand and graded stone aggregates of 40 mm nominal size in appropriate proportions as per specified design criteria and job mix formula approved by the Engineer -in-Charge, in airfield pavements/Roads laid in panels with necessary dummy/ construction/ expansion joints as per drawings/specifications or as directed by the Engineer-In-Charge, mechanically vibrated using Slip form paver /Fixed Form Paver/Manual method as decided by the Engineer-in-Charge as per site requirement & technical specification & providing 400 microns thick polythene sheet as antifriction layer , curing and providing & filling construction joints and dummy joints with approved polysulphide joint sealing compound (conforming to grade BS: 5212, 1990 or IS 11433-1995) including rounding off edges, priming the concrete surface with approved primer and filling the groove 10 mm x 10 mm deep at top for construction joints and 10mm x 10mm deep at top for dummy joints with approved polysulphide joint sealing compound, the balance depth of dummy joint if any, being filled with expanded polyethylene foam (Armor Board) including providing and applying bond breaker (polythene tape) on Armor board top surface, including preparing the surface and applying masking tape on front edge of joint to prevent accidental spillage of sealant on top surface and to give neat finish to the sealant and removing the masking tape after sealant has been applied and tooled and necessary arrangements for expansion joints etc. complete. Note: Antifiction layer, filler board and polysulphide sealant for expansion joint shall be paid separately. i) Mechanically cutting dummy joints 3 mm wide X 1/3rd thickness of slab which is subsequently widened to 10 mm for the top 25 mm depth and construction joints 10 mm wide X 25 mm deep as per specification.
Supplying and laying of sand 6 mm thick over dry rolled lean concrete layer including the cost of sand , removal of pebbles, rubbish etc. and screening if required etc. complete, as directed by Engineering -In Charge.
Providing and laying polythene sheet 400 micron thick, anti-friction layer on the sub-base course complete as per specification with specified overlaps between adjacent strips and transverse joint etc. (only plan area is measured for payment) complete as per direction and satisfaction of Engineer-in-charge.
Providing and laying in position for expansion joint, 25mm thick pre-cut Synthetic joint filler board of approved make conforming to IS:1838(part 3)-2011, 45 mm from top (to be removed at the time of filling of Polysulphide sealant), complete as per particular specifications and directions of Engineer-in-charge. (Note: Mode of measurement shall be length of joint multiplied by depth of filler board including precut portion.)
Providing and fixing white vitreous china Wall mounting water closet of approved make including providing & fixing with dual flush valve of flushing capacity 3 litre/6 litre (adjustable to 4 litre/8 litres), including seat cover, and nuts, bolts and gasket, Pan connector etc complete as per direction of Engineer In Charge. Item Consisting :- a) Wall Mounted WC Pan:-Hindware Dome 92517 Or Cera B1520105 Coupe or approved equivelent b) Seat Cover:-Hindware Comfort Or Cera Soft Close or approved equivelent c) Dual Flush valve:-Jaquar FLVCHR 1085 Or Cera F8010203 or approved equivelent
Providing and fixing Differecially abled toilets including Wash basin, Water closet,flush valve, grab bars & hand rails etc complete as per direction of Engineer In Charge. Item Consisting :- a) Two Piece Floor mounted WC Pan-01 no. of Cera CAT no.S1021113 or any Equivalent Approved make b) Cistern-01 no. of Cera CAT no. S1060106 or any Equivalent Approved make c) Soft Close Seat Cover -01 no of Cera CAT no.B1520118 or any Equivalent Approved make d) Twin Flush Fittings -01 no of Cera CAT no.B1810112 or any Equivalent Approved make e) Wash Basin 510 x 400 mm -01 no of Cera CAT no.S2040101 or any Equivalent Approved make f) Wall mounted Grab bar 600 mm long - 2 nos of Cera CAT no.B2210106 or any Equivalent Approved make g) Wall mounted Hinged hand rail 750 x 100-01 no Cera CAT no B2210108 or any Equivalent Approved make h) Sensor tap (with control box set)-01 no.of Cera CAT no F6010101 or any Equivalent Approved make
Providing and fixing water closet squatting pan (Orissa Type W.C. pan ) with 100 mm PVC P or S trap, dual flush valve, including flush pipe, Pan connector with all fittings and fixtures ,complete as per direction of Engineer In Charge. Item Consisting :- a) Orissa WC Pan Hindware Orissa 20004 Or Cera CALINA S3010102 or approved equivelent b) Dual Flush valve Jaquar FLVCHR 1085 Or Cera F8010203 or approved equivelent c) 100mm PVC P trap- Supreme or prince or approved equivelent
Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification . Item Consisting :- Sensor Operated Urinal Hindware Flow 60021 or Cera S4010102 or approved equivelent
Providing and fixing Under Counter wash basin with C.P. sensor pillar tap, 32 mm C.P. brass waste of standard pattern, CP bottle trap, CP angle stop cock, Braided hoist pipe including painting of fittings and brackets, cutting and making good the walls wherever require etc complete as per direction of Engineer In Charge.: Item Consisting :- a) Wash Basin Hindware Lara 10095 or Cera S2030114 or approved equivelent b) CP Sensor Taps Jaquar SNR-CHR-51021 Or Cera F6010101 or approved equivelent c) CP bottle trap Jaquar ALD 769 Or Cera F8060302 or approved equivelent d) CP Angle stop cock Jaquar FLR 5053N Or Cera F2002201 or approved equivelent e) Waste coupling Jaquar ALD 705 Or Cera F8050351 or approved equivelent f) Braided Hose pipe Jaqua ALD 803 Or Cera F8070402 or approved equivelent
Providing and fixing Half Pedestal wash basin with C.P. sensor pillar tap, 32 mm C.P. brass waste of standard pattern, CP bottle trap, CP angle stop cock, Braided hoist pipe including painting of fittings and brackets, cutting and making good the walls wherever require etc complete as per direction of Engineer In Charge.: Item Consisting :- a) Wash Basin Half Pedestal Hindware Mario 10087 Or Cera S2040112 or approved equivelent b) Half Pedestal Hindware 11027 Or Cera S2090120 or approved equivelent b) CP Pillar cock Pressmatic Jaqua PRS-CHR-031L65 Or Cera F9020101 or approved equivelent c) CP bottle trap Jaquar ALD 769 Or Cera F8060302 or approved equivelent d) CP Angle stop cock Jaquar FLR 5053N Or Cera F2002201 or approved equivelent e) Waste coupling Jaquar ALD 705 Or Cera F8050351 or approved equivelent f) Braided Hose pipe Jaqua ALD 803 Or Cera F8070402 or approved equivelent
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required etc.completeas per direction of Engineer In Charge.. Kitchen sink without drain board 610x510 mm bowl depth 200 mm i/c 32mm dia CP Waste coupling, CP Bottle Trap & Swinging type Sink Cock Item Consisting :- a) Sink Bowl Jayna Sink SBF 09 Or Cera B4511206 or approved equivelent b) CP bottle trap Jaquar ALD 769 Or Cera F8060302 or approved equivelent c) Sink Cock Jaquar CON-357KN Or Cera F3002261 or approved equivelent d) Waste coupling Jaquar ALD 705 Or Cera F8050351 or approved equivelent
Providing and fixing toilet roll holder with flap etc.complete of Jaquar ACN- 1153N Or Cera F5001109 Or any Equivalent Approved make as per direction of Engineer In Charge.
Providing and fixing of CP liquid soap container of pump type with initial soap fill i/c all hardwares etc complete of Jaquar ACN- 1135N Or Cera F5007111 Or Any Equivalent Approved make as per direction of Engineer In Charge.
Providing fixing C.P. brass towel rail of size 450 mm long fixed to cleats with CP brass Screws etc.complete of Jaquar ACN-1111BNM Or Cera F5007104 Or Any Equivalent Approved make as per direction of Engineer In Charge.
Providing & fixing CP Towel Ring with Flange etc.complete of Jaquar ACN-1121BN Or Cera F5007105 Or Any Equivalent Approved makeas per direction of Engineer In Charge.
Providing and fixing CP health faucet for ablution at toilets in heavy quality with 1m Long Braided Hose with Two 15mm Nuts & Rubber Washers Without Nipple i/c CP angle cock of approved make etc.complete as per direction of Engineer In Charge. . Item Details:- a) Health Facuet Jaquar ALD 577 Or Cera F8030201 or approved equivelent b) CP Angle stop cock Jaquar FLR 5053N Or Cera F2002201 or approved equivelent
Providing and fixing 15 mm nominal bore CP brass bib cock of Jaquar CAT FLR 5047N or equivelent make etc.complete as per direction of Engineer In Charge. .
Supplying & Fixing C P Angle Stop Cock of Jaquar FLR 5053N Or Cera F2002201 Or Any Equivalent Approved make complete as per direction of Engineer In Charge. .
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings etc.with Semi rigid pipe,complete as per direction of Engineer In Charge.
32 mm dia
40 mm dia
50 mm dia
Supplying & fixing PVC Pipes conforming to I.S - 13592 type B including necessary fittings and joining with rubber rings and lubricants as per standard practice with holder bats; PVC clamps, dash fasteners fixed to walls,beams, or ceiling as required slope, pcc bedding and necessary special heavy detachable MS bracket and Testing as per standard Practice etc. complete as per direction of Engineer In Charge. . Soil, Waste & Vent Pipes
110 mm dia pipe.
75 mm dia pipe.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, Single socketed pipes.
75 mm diameter
110 mm diameter
160 mm diameter
Providing and fixing PVC 'P' Trap with SS Grating etc. complete as per direction of Engineer In Charge. . 110 X 110 mm dia Size
Providing and fixing PVC Nahani / Multi Trap with SS Grating etc. complete as per direction of Engineer In Charge. 75 mm dia Size
Providing and fixing PVC clean out plug with necessary joints etc. completeas per direction of Engineer In Charge.
110 mm dia
75 mm dia
Providing and fixing PVC vent cowl with joints etc. complete as per direction of Engineer In Charge.
110 mm dia
75 mm dia
Providing and fixing 6mm thick bevelled edge mirror of normal glass with stud of approved quality and approved make with VHP tap (3M) & 25mm dia stainless steel stud and 10mm brush finish stainless steel trims machine cut in required size and shape as approved shade colour etc complete at all levels as per detailed drawings and direction of Engineer in Charge.
Providing and fixing to the inlet mouth of PVC pipes for surface drain PTMT (an Engineering Thermoplastic) grating square (Slit) 150 mm square with a height of 8 mm and weighing not less than 100 gms.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall
15 mm nominal outer dia Pipes
20 mm nominal outer dia Pipes
25 mm nominal outer dia Pipes
32 mm nominal outer dia Pipes
40 mm nominal outer dia Pipes
50 mm nominal outer dia Pipes
65 mm nominal outer dia Pipes
80 mm nominal outer dia Pipes
100 mm nominal outer dia Pipes
150 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.
15 mm nominal outer dia Pipes
20 mm nominal outer dia Pipes
25 mm nominal outer dia Pipes
32 mm nominal outer dia Pipes
40 mm nominal outer dia Pipes
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
32 mm nominal bore
40 mm nominal bore
50 mm nominal bore
65 mm nominal bore
80 mm nominal bore
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
15 mm nominal bore
20 mm nominal bore
25 mm nominal bore
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work
15 mm nominal outer dia Pipes
20 mm nominal outer dia Pipes
25 mm nominal outer dia Pipes
32 mm nominal outer dia Pipes
40 mm nominal outer dia Pipes
50 mm nominal outer dia Pipes
62.5 mm nominal outer dia Pipes
75 mm nominal outer dia Pipes
100 mm nominal outer dia Pipes
150 mm nominal outer dia Pipes
Supplying and fixing 150 mm dia. G.I 'C' Class pipes to IS: 1239, screwed/ flanged/welded as specified and with heavy clamps, hangers, brackets or pipe supports all with screwed/bolted joints as required including necessary specials,fixing supports into masonry walls or RCC with anchor fasteners and painting with two finishing coats of enamel paint of approved colour over a coat of approved primer after hydraulic testing to 13.55 Kg/Sq.cm pressure, complete as specified & as per direction of E-I-C.
Supplying and fixing 200 mm dia. M.S 'C' Class pipes to IS: 3589, screwed/ flanged/welded as specified and with heavy clamps, hangers, brackets or pipe supports all with screwed/bolted joints as required including necessary specials,fixing supports into masonry walls or RCC with anchor fasteners and painting with two finishing coats of enamel paint of approved colour over a coat of approved primer after hydraulic testing to 13.55 Kg/Sq.cm pressure, complete as specified & as per direction of E-I-C.
Providing and fixing Cast Iron Butterfly valve with SS Disc Nitrile Rubber Seal & O- Ring PN 16 pressure rating with hand lever operated including nut, bolt, flanges, gasket etc. complete as per direction of Engineer-In-Charge
50 mm nominal bore
65 mm nominal bore
80 mm nominal bore
100 mm nominal bore
150 mm nominal bore
Providing and fixing Ball valve (bronze) of Zoloto, Leader or Equivalent , High or low pressure complete as per direction of E-I-C.s directed. 32 mm nominal bore
Providing and Fixing GM 15 mm Air release valve,(Make:- Zoloto, Leader or Equivalent) having threaded connection including the cost of 15 mm dia Brass Ball valve with required fittings & as per direction of E-I-C.
Providing and Fixing pressure Reducing valve (Make:- Zoloto, Leader or Equivalent) including the valves ,Tees, bend, Isolation valves of approved make the work shall also include accessories necessary for proper installation. in accordance to specification, drawings and preamble subject to the approval of the E-I-C.
Forged Brass 32 mm dia
Forged Brass 40 mm dia
Forged Brass 50 mm dia
Bronze 65 mm dia
Providing M.S. foot rests including fixing in RCC walls as per standard design : With 20x20 mm square bar
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : With 20x20 mm square bar
Providing and fixing in Position Pre-Cast RCC Man hole cover and frame of required shape and Approved quality - LD-2.5 Rectangular shape 600x450 mm internal dimensions
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality EHD - 35 Circular shape 560 mm internal diameter
Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : For pipes 100 to 250 mm diameter
Providing and laying Non Pressure NP-4 class (Heavy duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete
1200 mm dia RCC pipes. (Laying by mannual/ machenical means)
900 mm dia RCC pipes.
600 mm dia RCC pipes.
450 mm dia RCC pipes.
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :
150 mm dia. R.C.C. pipe
250 mm dia. R.C.C. pipe
300 mm dia. R.C.C. pipe
450 mm dia. R.C.C. pipe
600 mm dia. R.C.C. pipe
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :
100 mm diameter
150 mm diameter
250 mm diameter
300 mm diameter
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 100x100 mm size P type With Sewer bricks conforming to IS : 4885
Constructing brick masonry manhole in cement mortar 1:4 ( 1cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominalsize), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 120x90 cm and 90 cm deep including C.I. cover withframe (heavy duty) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg (weight of cover 108 kg and weight of frame 100 kg) : With Sewer bricks conforming to IS : 4885
Extra for depth for manholes : Size 120x90 cm With Sewer bricks conforming to IS : 4885
Constructing brick masonry circular manhole 1.52 m internal dia atbottom and 0.56 m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand) inside cement plaster 12 mm thick with cement mortar1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :2.30 m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) : With Sewer bricks conforming IS : 4885
Extra depth for circular type manhole 1.52 m internal dia (at bottom) beyond 2.30 m : With Sewer bricks conforming IS : 4885
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even afterfixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
Providing and fixing 65 mm horizontal /vertical type GM non return valve tested to21 kgf/sq.cm. With flanged type connection as per direction of E-I-C.
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 65 mm nominal bore
Supplying and fixing 100 mm dia GI 'C' class pipe of IS grade, laid to required slope in trenches or clamped to ceiling including clamped fittings as per specificationincluding two coats of approved paint over a primer as per direction of E-I-C.
Supplying and fixing 80 mm dia GI 'C' class pipe of IS grade, laid to required slope in trenches or clamped to ceiling including clamped fittings as per specificationincluding two coats of approved paint over a primer as per direction of E-I-C.
Providing, driving with hydraulic piling rigs with power units and installing driven cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of shoe and the length of pile to be embedded in the pile cap etc. all complete. (Length of pile for payment shall be measured from top of shoe to the bottom of pile cap) : 500 mm dia piles
Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately): For fixed portion Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately): For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with PVC/neoprene gasket, aluminum snap beading, aluminum channel etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminum snap beading, channel shall be paid in basic item) With float glass panes of 8 mm thickness .
Filling the gap in between aluminum frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5mm depth and 5 mm width
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with nonwoven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 3 mm thick
Providing and mixing integral crystalline admixture for waterproofing treatment to RCC structures like basement raft, retaining walls, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc. at the time of transporting of concrete into the drum of the ready-mix truck, using integral crystalline admixture @0.80% (minimum) to the weight of cement content per cubic meter of concrete) or higher as recommended by the manufacturer's specification in reinforced cement concrete at site of work. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducing permeability of concrete by more than 90%, compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure. The crystalline admixture shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guaranteed for 10 years against any leakage.
For vertical surface two coats @0.70 kg per sqm per coat
For horizontal surface one coat @1.10 kg per sqm
Providing and applying crystalline mortar by mixing in the ratio of 4.5 : 1 (4.5 parts crystalline mortar : 1 part water) for the treatment of faulty construction joints, cracks, tie rod holes and spalled & honeycombed surface of RCC underground structures like basement, water tanks, bridge deck etc. to ensure water tightness. The crystallie mortar shall conform to the EN 1504-3 having compressive strength Class R4 > 45 MPa and adhesive bond strength Class R3 > 1.5 MPa. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. For patching of tie rod holes, preparing tie rod hole surface and then priming the area with integral crystalline slurry @0.070kg per sqm and while the surface is tacky, repairing and then filling the tie rod holes with crystalline mortar @0.040kg per hole. The crystalline mortar shall be tightly rodded into tie rod holes or packed tightly (For 25x25x25 mm tie rod hole, use 0.040 kg to fill the hole)
Providing and applying of swellable type water stop tape, 19mm x 25mm thick in linear meter (expansive nature) for construction joints treatment of RCC structure, such as raft slab, retaining walls, water storage tank and at the junctions of raft slab with the retaining walls etc.. After cleaning the surface, one coat of required primer for swellable water stop tape shall be applied throughout the length of the joint @3.78 litre per 240 running meter. Over the primed surface swellable type water stop tape shall be placed. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guaranteed for 10 years against any leakage.
Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately.For the purpose of measurement the entire treated surface will be measured.
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer- in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer- in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
SUNKEN AREA WATER PROOFING Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. The product performance shall carry guaranteed for 10 years against any leakage.
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level.
All types of soil 300 mm dia
Rocky strata including Boulders 300 mm dia
Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge.
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) slotted pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge 150 mm nominal size dia
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge.
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 150 mm nominal size dia
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 150 mm dia. R.C.C. pipe
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. Rocky strata including Boulders 300 mm dia
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge
Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/ plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge. 200 mm nominal size dia having minimum wall thickness 5.40 mm
Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed/ plain bevel ended pipe (type A) of required dia, conforming to IS: 8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200mm dia.
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200mm dia
WT-01 HYBRID CURTAIN WALL SYSTEM - TENSION -COMPRESSION ROD ALUMINIUM WT / m2 FOR WT-01= 3.0 Kg/m2 Providing and supplying aluminium extruded sections as per architectural drawings & approved shop drawings,the aluminium quality as per grade 6063 T5 OR T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2605 of required colour and shade as approved by the Architect/Engineer-in-charge.(The item included cost of material such as cleats,sleeves,screws etc necessary for fabrication of extruded aluminium frame work.Nothing extra shall be paid on this account.
WT-01 HYBRID CURTAIN WALL SYSTEM - TENSION -COMPRESSION ROD (Excluding Aluminium Extrusion & M.S.Structure) (System+Installation Cost Only) Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: For Detail please refer item no.228 in Tender documents & SOQ
GL-01 VISION GLASS FOR WT-01 ( Fritted Glass ) (Glass Supply & Delivery at Site Cost Only) Supplying & Delivering at site vision glass panels of Approved make comprising of hermetically-sealed 41.04mm Thick Laminated Insulated Glass Unit.The laminated IGUs shall be assembled in the factory/workshop of the glass processor. Performance and shade as per direction of engineer in charge. Rate shall include all wastage & landing cost on site. For Detail please refer item no.229 in Tender documents & SOQ
GL-02 VISION GLASS FOR WT-01 (NON-FRITTED GLASS) (Glass Supply & Delivery at Site Cost Only) Supplying & Delivering at site vision glass panels of Approved make comprising of hermetically-sealed 41.04mm Thick Laminated Insulated Glass Unit.The laminated IGUs shall be assembled in the factory/workshop of the glass processor. Performance and shade as per direction of engineer in charge. Rate shall include all wastage & landing cost on site. For Detail please refer item no. 230 in Tender documents & SOQ
Providing and fixing structural steel frame (for dry cladding with 40 mm thick gang saw cut with machine cut edges sand stone) on walls at all heights using M.S. square/ rectangular tube in the required pattern as per architectural drawing, including cost of cutting, bending, welding etc. The frame work shall be fixed to the wall with the help of M.S. brackets/ lugs of angle iron/ flats etc. which shall be welded to the frame and embedded in brick wall with cement concrete block 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) of size 300x230x300 mm, including cost of necessary centring and shuttering and with approved expansion hold fasteners on CC/RCC surface, including drilling necessary holes. Approved cramps/ pins etc. shall be welded to the frame work to support stone cladding, the steel work will be given a priming coat of Zinc primer as approved by Engineer in- charge and painted with two or more coats of epoxy paint (Shop drawings shall be submitted by the contractor to the Engineer-in-charge for approval before execution). The frame work shall be fixed in true horizontal & vertical lines/planes. (Only structural steel frame work shall be measured for the purpose of payment, stainless steel cramps shall be paid for separately and nothing extra shall be paid).
Providing and fixing adjustable stainless steel cramps of approved quality, required shape and size, adjustable with stainless steel nuts, bolts and washer (total weight not less than 260 gms), for dry stone cladding fixed on frame work at suitable location, including making necessary recesses in stone slab, drilling required holes etc complete as per direction of the Engineer-in-charge.
SANDSTONE FOR WT-02 (DRY WALL CLADDING) Providing and fixing dry cladding upto all heights with 40mm thick gang saw cut stone with (machine cut edges) of uniform colour and approved size, fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge. (The steel frame work, stainless steel cramps and pins etc. shall be paid for separately). Jodhpur Pink sand stone - 40mm thick gang saw cut stone of approved shade
DOUBLEDOUBLE LEAF MANUAL SWING DOORS : TOP & BOTTOM RAIL WITH FLOOR SPRING (FOR WT-01 & 02) (Door Hardwares + Glass Supply + Installation Cost Only) Designing, engineering, fabricating, packaging,delivering (jobsite)installing and fixing in position: Supply and installation of Double leaf Manual Swing Door inclusive of 13.52mm Thk Non-Performance Laminated Glass as per dimension and specification as indicated in tender drawings and as per direction of engineer in charge For Detail please refer item no. 234 in Tender documents & SOQ
WT-04 ROOF SKYLIGHT -20mm THK MULTIWALL POLYCARBONATE SHEET CLADDING (Excluding M.S.Structure) (Supply of Multiwall Polycarbonate sheet at site + Installation Cost Only) Designing, engineering, fabricating, protecting,packaging,delivering (jobsite),installing and fixing in position: Design, Manufacture, Supply and Installation of system, a complete assembly of co-extruded UV protected 20 mm thick (min) multi-layered polycarbonate panels incorporated into a complete system in roof skylights . For Detail please refer item no. 235 in Tender documents & SOQ
WT-05 SPIDER GLAZING SYSTEM:FRAMELESS GLAZING Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel For Detail please refer item no. 236 in Tender documents & SOQ
GL-04:VISION GLASS FOR WT-05 (SPIDER GLAZING) Extra for providing vision glass panels comprising of hermetically sealed 15.52mm Laminated glass : 6mm thick clear Fully Tempered glass + 1.52mm thick Clear Sentry Plus Interlayer + 8mm thick clear Fully Tempered glass instead of 12mm thick clear toughened glass wherever required & as per direction of Engineer-in-charge .
WT-06 FIXED Glazing @ Rotunda (System Cost Excluding M.S.Structure) (System + Installation Cost Only) Designing, engineering, fabricating,protecting,packaging,delivering (jobsite)installing and fixing in position: For Detail please refer item no. 238 in Tender documents & SOQ
GL-04: NON PERFORMANCE VISION GLASS FOR WT-06 (FIXED GLAZING) (Glass Supply & Delivery at Site Cost Only) Supplying & Delivering at site vision glass panels comprising of hermetically sealed 15.52mm Laminated glass : 8mm thick clear Fully Tempered glass + 1.52mm thick Clear Sentry Plus Interlayer + 6mm thick clear Fully Tempered glass.The laminated glass shall be assembled in the factory/workshop of the glass processor.Rate shall be including wastage and landing cost all complete and as per direction of engineer in charge Mode of Measurement: For payment only the actual area of glass on face #1 of the glass panels (excluding the width of grooves and weather silicone sealant) and the portion of glass panel inside the S.S. channel fixed in position,shall be measured in sqm.
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
WT-07 ALUMINIUM SOFFIT CLADDING (Excluding Aluminium Extrusion & M.S.Structure) Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: For Detail please refer item no. 241 in Tender documents & SOQ
WT-08 GLASS CANOPY (Excluding Tension Rod & M.S.Structure) (System + Installation Cost Only) Designing, engineering, fabricating, testing,protecting,packaging,deliverin (jobsite),installing and fixing in position complete as per direction of E-I-C: For Detail please refer item no. 242 in Tender documents & SOQ
GL-06:NON PERFORMANCE VISION GLASS FOR WT-08 (Glass Canopy) (Glass Supply & Delivery at Site Cost Only) Providing,assembling & supplying vision glass panels comprising of hermetically sealed 17.52mm Laminated glass ( ceramic fritting witha pattern) : 8mm thick clear Fully Tempered (Heat Soak) glass + 1.52mm thick Clear Sentry Plus Interlayer + 8mm thick clear Fully Tempered ( Heat Soak) glass..The laminated glass shall be assembled in the factory/workshop of the glass processor.Rate shall be including wastage and landing cost all complete and as per direction of engineer in charge Mode of Measurement: For payment,only the actual area of glass on face # 1 of the glass panels (excluding the width of the grooves and weather silicone sealant)provided & fixed in position,shall be measured in sqm.
WT-09 GLASS HIGH HT. PARTITION-1 (System + Installation Cost Only) Designing, engineering, fabricating, testing,protecting,packaging,deliverin (jobsite),installing and fixing in position: Height of Partition-1: 2100mm For Detail please refer item no. 244 in Tender documents & SOQ
WT-09 GLASS HIGH HT. PARTITION-2 (System + Installation Cost Only) Designing, engineering, fabricating, testing,protecting,packaging,deliverin (jobsite),installing and fixing in position: Height of Partition-1: 2400mm For Detail please refer item no. 245 in Tender documents & SOQ
GL-04:NON PERFORMANCE VISION GLASS FOR WT-09 (Glass Railing) (Glass Supply & Delivery at Site Cost Only) Supplying & Delivering at site vision glass panels comprising of hermetically sealed 15.52mm Laminated glass : 8mm thick clear Fully Tempered glass + 1.52mm thick Clear Sentry Plus Interlayer + 6mm thick clear Fully Tempered glass.The laminated glass shall be assembled in the factory/workshop of the glass processor.Rate shall be including wastage and landing cost all complete and as per direction of engineer in charge Mode of Measurement: For payment,only the actual area of glass on face # 1 of the glass panels (excluding the width of the grooves and weather silicone sealant)provided & fixed in position,shall be measured in sqm.
LIFE LINE FALL ARREST SYSTEM Designing,supplying, engineering, fabricating,transportation,installation,commissioning of Façade Access System: Supplying and fixing of Horizontal Anchorage Life lIne system for fall protection on standing seam profile roof system. For Detail please refer item no. 247 in Tender documents & SOQ
Supply,installation & commissioning of Self Proppeled Articulated Boom Lift (Working height= 23 Mtrs) to work as aerial work platforms with multiple sections that "articulate," allowing the user to gain access to work areas that may be blocked by barriers or obstacles to workperfectly in area with hard to reach places.Commisioning of the system will be certified by E-I-C.
Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge.
Providing, supplying, casting, handling and installing feature column
As per the drawing No. AAI-DCI-A/31086-ID-401. It will have all the openings, on vertical and inclined surfaces of this feature column (as per approved design and patterns), shall have peripheral offsets to hold toughened, laminated glass panels, as per detailed drawings and specifications. After fixing, visible surface of these glass panels and the visible surface of the feature column should be in the same planes and should follow the same form of the feature column. After fixing of these glass panels (at top and on vertical / inclined surfaces of the feature column), there should not be any possibility of dirt / insects, etc. entering the feature column. For maintenance purposes, provision to access the insides should be made, as directed by the Architect & Direction of Engineer-In-charge For Detail please refer item no. 250.01 in Tender documents & SOQ
As per the drawing No. AAI-DCI-A/31806-AD-401 . GRC Panels will be in suitable sizes including all material, labour, equipment and related services to form column cladding as shown in drawings and specifications and as approved by Architects. GRC cladding panels shall be installed and fixed to structural steel secondary framework attached to main column. GRC shall be confirming to BS EN 1169, BS EN 1170, EN 15422. For Detail please refer item no. 250.02 in Tender documents & SOQ
Providing and erecting 2.00 metre high temporary barricading at site; each panel of size 2.50x2.00m made of 40x60mm angle iron or 50x50x3mm hollow MS tube posts/horizontal memers/bracings covered with 1.63mm thick MS sheet. The sheet shall be fixed with 30x5mm MS flat by suitable welding/riveting. The panels shall be made so that gap of 50cm above the ground is available making overall height as 2.5m. MS channel ISLC 75@ 5.70kg/m, 50cm long shall be provided at the bottom having oval shaped holes of size 50x25mm at both ends with 50cm long MS angle 40x40x6mm bracing. Suitable arrangement shall be made to fix the barricading to aviod from overturning by providing 250mm long expansion fasterners at both ends. The work shall be executed as per drawing/direction of Engineer-in-Charge which includes writing and painting, arrangement for traffic diversion such as traffic signals during construction at site for day and night, glow lamps, reflective signs, marking, flags, caution tape as directed by the Engineer-in- Charge. The barricading provided shall be retained in position at site continuously i/c shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion. Rate include its maintenance for damages, painting, all incidentals, labour materials, equipments and works required to execute the job. The barricading shall not be removed without prior approval of Engineer-in-Charge. (Note :- One time payment shall be made for providing barricading from start of work till completion of work i/c shifting. The barricading provided shall remain to be the property of the contractor on completion of the work).
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix)
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
Providing, making and placing in position Check-in counters made up from 19mm thick block board covered with 1.00mm thick laminate of approved make/ shade having hard wood base of specified section including fixing of 12mm thick acrylic polymer solid surface of corian (LG Himac, Dupoint, Neonnex or equivalent as approved) at the designated location with necessary fixtures ,fittings etc. complete as shown in the drawing and as per the direction of the Engineer-In-Charge.
Providing, making and placing in position Ticket Counter made up from 19mm thick block board covered with 1.00mm thick laminate of approved make/ shade having hard wood base of specified section including fixing of 12mm thick acrylic polymer solid surface of corian (LG Himac, Dupoint, Neonnex or equivalent as approved) at the designated location with necessary fixtures ,fittings etc. complete as shown in the drawing and as per the direction of the Engineer-In-Charge.
Providing, making and placing in position Inspection Desk made up from 19mm thick block board covered with 1.00mm thick laminate of approved make/ shade having hard wood base of specified section including fixing of 12mm thick acrylic polymer solid surface of corian (LG Himac, Dupoint, Neonnex or equivalent as approved) at the designated location with necessary fixtures ,fittings etc. complete as shown in the drawing and as per the direction of the Engineer-In-Charge.
Providing, making and placing in position Writing Desk ( twin sided) made up from 19mm thick block board covered with 1.00mm thick laminate of approved make/ shade having hard wood base of specified section including fixing of 12mm thick acrylic polymer solid surface of corian (LG Himac, Dupoint, Neonnex or equivalent as approved) at the designated location with necessary fixtures ,fittings etc. complete as shown in the drawing and as per the direction of the Engineer-In-Charge.
Providing and fixing in position security check inspection & X-ray Monitoring table of following sizes consisting of 19mm thick Commercial board of BWR grade covered with 12mm thick corian of approved shade pasted over the CBB with adhesive and all necessary screws etc. complete and as per direction of the Engoneer-in-Charge.
Providing, making and placing in position security check & stamping table Pedestal ( gents) made up from 19mm thick block board including fixing of 12mm thick acrylic polymer solid surface of approved shade(LG Himac, Dupoint, Neonnex or equivalent as approved) and 1.0mm thick white Laminate on the under faces of the Desk at the designated location with rounded edges with necessary fixtures ,fittings etc.complete as shown in the drawing and as per the direction of the Engineer-In-Charge.
Providing, Fabricating and installation in position of Security check for ladies (Frisking Booth ) comprising frame work of SS Section 50 x 50x 3mm over the 12mm thick M.S base Plate fixed to the floor with the help of the fasteners.The frame work is covered with 12mm thick Toughened Glass screwed to the SS frame work with the help of 25 dia SS studs,the toughened glass shall have 3 mm thick fasara film Matte crystal ( SH2 MACRX ) patsed internally, the frisking booth shall be a complete unit in itself with all necessary fittings, fixtures etc.complete and as per the direction of the Engineer-In-Charge.
Providing and laying 3 M or Euronics or approved equivelent make Modular matting (whipping & scrapping -moisture & dirt recessed ) for areas like main entry/ exit or whereever required as per the technical specification and direction of Engineers incharge.
Providing and placing stainless steel Swing Bin ( Dustbins) of Sizes 14"x 28" made of 2mm thick 202 grade Stainless steel sheet all as per manufacturers specification etc complete and as per the direction of the Engineer-In-Charge.
Art Panel on wall – Deep and intricate carving on AAC block Location - Pre-check in area at ground floor Size - The feature wall shall be 83m in length and 7.9m in height, installed at a height of 6.4m from ground floor upto the bottom of ceiling. Fabricating, supplying and installing Art relief panel on the wall surface made out of 100 mm thick AAC (Autoclaved Aerated Concrete) block with deep & intricate carving on the theme depicting the culture and temples of Char Dham of Uttarakhand. The size of the panel shall be 83 m x 7.9 m (approx.) and shall be a combination of different sizes of AAC blocks to be fixed on 12 mm thick cement board of 1.2m x 1.2m or suitable size for easy portability and shall portray ritual designs of pujas, festivals and ceremonies depicting birth, janoi, marriage & death. The art panel shall cover local art form called Aipan (Aipana) which is popular art form of Kumaon in which pieces of cloth are decorated by the drawing of various geometric and other figures belonging to gods, goddesses and objects of nature. The art panel shall also cover clay images called Dekara" which portray gods & goddesses. The art panel shall be fabricated as per instructions of Architect and Art Curator of Dehradun Airport and local artisans may be involved. Please refer tender drawing AAI-DCI-A/31806-ID-402. This ready panel shall be installed on site in the following sequence: 1 fix the panel directly on wall with S.S. screws to hold it properly & touch up all nailed areas. 2 The painting of the art panel shall be done with two or more coats of superior quality acrylic emulsion paint including touch-up to the edges etc.
Wall painting on a plain surface: Location - Ground Floor on Baggage Claim area with ID no FW2 Size - The feature wall shall be (approx.) 60 m length and 8.1m in height starting from finished floor level on ground floor. Fabricating, Supplying and installing wall painting with intricate detail & colours in 2d-3d mixed work on 12 mm thick High Density Wood Plastic Composite (HD WPC) sheet. The proposed size of the panel is 60 m x 8.1 m, (approx.) which shall portray wall painting found in Buddhist monasteries for which local artisans can be involved. Please refer drawing AAI-DCI-A/31806-ID-402. This panel should be transported from workshop to Dehradun airport in shockproof & tamper proof packing safely and installed directly on wall with S.S. screws to hold it properly & touch up all nailed areas. Superior quality of acrylic emulsion paint (2 or more coats) shall be used for painting. The painting shall be prepared as per instructions of the Architect and Art Curator of Dehradun Airport.
Aglaonema commutatum (3 plant in a pack) of Height- 9"- 12"
Alpinia intermedia 'Sunspice'(3 plant in a pack) of Height- 12"- 15"
Dracaena song of india (3 plant in a pack) of Height- 12"- 15"
Petunia varie. (4-5 plant in a pack) of Height- 4"- 6"
Black ficus (1 plant in a pack) of Height- 60"- 66"
Arica palm (1 plant in a pack) of Height- 5'- 6'
Rhapis palm (1 plant in a pack) of Height- 36"- 40"
Supplying 10" dia plastic pots inclusive of delivery on site etc complete.(cost of plant is excluded)
Supplying 12" dia plastic pots inclusive of delivery on site etc complete.(cost of plant is excluded)
Labour for planting in plastic pots with soil manure,coco pit,sand & arranging white pebbles on top etc complete and placing at the desired location as per direction of EIC .(cost of plant & white pebbles is excluded)
Supplying and stacking of White River (Stone) Pables size of 2" to 2.50" dia in natural colour at site of work including loading, unloading, carriage and all taxes paid etc.complete and as per direction of engineer in charge.
WIRING & ACCESSORIES POINT WIRING Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
Wiring for MCB controlled light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required(MCB cost is included in the DB).Group C
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
3 x 2.5 sq. mm
3 x 4 sq. mm
6 X 6 sq.mm.
Supplying and fixing of following sizes of steel conduit along with accessories in surface / recess including painting in case of surface conduit or cutting the wall and making good the same in case of recessed conduit as required
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
DISTRIBUTION BOARDS,MCBs & MCCBs Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator)
4 way (8 + 12), Double door
6 way (8 + 18), Double door
8 way (8 + 24), Double door
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 12 way (8+ 36), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Triple pole & Neutral
Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 32A
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing 32 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 32 A, “C” curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying & installation of 63A. Industrial type socket outlet with top(industrial lock in type).
INTERNAL LIGHT FIXTURES & INSTALLATION Supply, installation, testing & commissioning of LED recessed mounted circular downlighter made of pressure die cast aluminum housing with translucent PMMA diffuser, LED Used shall be SMD type and minimum system lumens of 1800, Life of fixture (Including Driver) : 50K Hrs. @ L70B50 Lumen maintenance, CCT up to 4000, C, IP20. Minimum Internal Surge Protection 2.5 KV. The fixture design should comply with IS10322, EMC/EMI compliance maintaining driver leakage current as per as per IEC 60598, Make: Trilux Ambiella Plus IND G3 LED1530-840 ET / Wipro CRDL11R023HP40DE / Philips DN395B LED20S-4000 PSU WH or equivalent models as per specification.
Supply, installation, testing & commissioning of LED Recess mounted 600x600mm fitting made of white CRCA powder quoted finish with fully covered by PMMA Diffuser, LED Used shall be SMD type with minimum system Lumens 3600. Life of fixture : 50K Hrs. @ L70B50 Lumen maintenance, CCT 4000, IP20, minimum Internal Surge Protection 2.5KV The fixture design should comply with IS:10322 & Must be EMC / EMI compliance maintaining driver leakage current as per as per IEC 60598, complete as required. Make:,Trilux Enterio IND M73 OA LED 3600-840 ET / Wipro CRCO10R036HP40G1DE / Philips RC380B LED34S-4000 G3 PSU OD or equivalent models as per specification.
Supply, installation, testing & commissioning of LED Recessed Mounted Circular Downlighter made of pressure die cast aluminum housing with translucent PMMA diffuser, LED Used shall be SMD type and fixture should have minimum system Lumens 1200. Life of fixture (Including Driver) : 50K Hrs. @ L70B50 Lumen maintenance, CCT up to 4000, IP20 . Minimum Internal Surge Protection 2.5 KV. The fixture design should comply with IS10322, EMC/EMI compliance maintaining driver leakage current as per as per IEC 60598, complete as required As Trilux Ambiella Plus IND G3 LED1000-840ET/ Wipro CRDL11R017HP40DE / Philips DN393B LED12S-4000 PSU WH or equivalent models as per specification.
Supply , installation, testing & commissioning of Surface Mounted Linear LED fitting made of Extruded Aluminium , LED Used shall be SMD type and fixture should have minimum system Lumens 3600. Life of fixture (Including Driver) : 50K Hrs. @ L70B50 Lumen maintenance, CCT 5700 - 6500 K, IP 20, Minimum Internal Surge Protection 3KV. The fixture design should comply with IS10322, EMC/EMI compliance maintaining driver leakage current as per as per IEC 60598, Make: Trilux LED Batten D OTA LED 3600 CW ET / /NW L1200 FR / Wipro LE10-491-XXX40DE / Philips BN108C LED 40S PSU NW WH or equivalent models from the approved list of makes.
Supply, installation, testing & commissioning of LED Industrial Bay luminaire, electrical Class I, Aluminium die cast with IP 65 optical compartment with a polycarbonate protector for an optimal luminous flux having minium system lumen of 11500 and the control gear shall have IP 65 tightness level. The luminaires shall have CCT of 4000 - 5700K and, surge protection 4KV, . The beam angle of the luminaire shall be 120 degree wide for the uniform photometric distribution. The luminaires shall have direct access to gear and electronic compartment, a driver (efficiency > 90%*) with internal surge protection of 4 kV (in both Common and Differential modes),. The Luminaire shall be with factory fitted eye bolt for suspension ease in installation. complete as required as Trilux LBL 11500 ET / Wipro LH17-132-090-50-DE / Philips Maxoled BY415 LED90S WB FG PSU or equivalent models as per specification.
Supply, installation, testing & commissioning of Round LED downlight with faceted aluminium reflector recessed downlight for cut-out ceiling openings. Installation in cast concrete ceilings via accessories. Tool-free ceiling installation via rapid-mounting springs.Luminaire luminous flux minimum 4400 lm, Light colour neutral white, colour temperature 4000 K, colour rendering index Ra > 80. Service life L80(t q 25 °C) = 70,000 h, service life L85(t q 25 °C) = 50,000 h. Ceiling mounting frame of die-cast aluminium powder-coated white. Heatsink of die-cast aluminium, powder-coated white, IP54 protection rating on room side in combination with closed decorative cover. Safety class (EN 61140): II, protection rating (DIN EN 60529): impact resistance level in accordance with IEC 62262: IK03/0,35 J, testing temperature of wire glow test in accordance with IEC 60695-2-11: Make: Trilux InperlaL G2 C07 BR25 4700-840 / Wipro LH17-132-090-50-DE / Philips DN570B LED40S/840 PSEU-E CWH or equivalent as per specification.
Supply, installation, testing & commissioning of LED Recessed Mounted Circular Downlighter made of pressure die cast aluminum housing with translucent PMMA diffuser, LED Used shall be SMD type and fixture should have minimum system Lumens 800. Life of fixture (Including Driver) : 50K Hrs. @ L70B50 Lumen maintenance, CCT up to 4000, Minimum Internal Surge Protection 2.5 KV. The fixture design should comply with IS10322, EMC/EMI compliance maintaining driver leakage current as per as per IEC 60598, complete as required. Make:Trilux Ambiella IND G3 LED 640-840 ET / Wipro CRDL11R013HP40DE / Philips DN 392BLED10S-6500 PSU WH or equivalent model from the approved list of makes.
Supply, installation, testing & commissioning of LED flexible type Strip Light complete with drivers etc. complete as required. Make: Wipro LS06-015-120-WW-50 / Philips CAT NO.- LS152S LED8/WW L5000 IN Flexible Strip Light / Trilux LEDM Flexi Strip light 15W/M (In Metre) or equivalent as per specifications.
Supply, installation, testing & commissioning of LED floodlight for planar lighting and accent lighting. Pivotable fixing bracket for suspended and vertical mounting. Aluminium reflector with reflection-intensifying coated surface. With rotationally symmetrical wide light distribution. Min. Luminaire luminous flux 7500 lm, Light colour neutral white, colour temperature 4000 K, Service life L80(t q 25 °C) = 50,000 h., Spotlight body of die-cast aluminium, Colour black/similar to RAL 9005, highly weather resistant, powder-coated. Cover of non-laminated safety glass Safety class (EN 61140): I, protection rating (DIN EN 60529): IP65, impact resistance level in accordance with IEC 62262: IK09/10 J. With electronic driver, switchable. Surge voltage resistance 4 kV. The luminaire complies with fundamental requirements of applicable EU regulations and product safety legislation and bears the CE symbol. As Trilux Combial 30-RB8R/7500-740 1G1W ET / Wipro LF19-931-060-57-DE / Philips BVP122 LED110 NW FLNB FG XTFC or equivalent as per specification.
Supply, installation, testing & commissioning of LED floodlight for planar lighting and accent lighting. Pivotable fixing bracket for suspended and vertical mounting. Aluminium reflector with reflection-intensifying coated surface. With rotationally symmetrical wide light distribution. Min Luminaire luminous flux 12000 lm, Light colour neutral white, colour temperature 4000 K, Spotlight body of die-cast aluminium. Colour black, similar to RAL 9005, highly weather resistant, powder-coated. Cover of non-laminated safety glass Safety class (EN 61140): I, protection rating (DIN EN 60529): IP65, impact resistance level in accordance with IEC 62262: IK09/10 J. With electronic transformer, switchable. Surge voltage resistance 4 kV. The luminaire complies with fundamental requirements of applicable EU regulations and product safety legislation and bears the CE symbol. As Trilux Combial 40RB8R/12000-740 1G1W / Wipro LF20-132-060-57-DE / Philips BVP122 LED128 CW FLNB FG XTFC or equivalent as per specification
LIGHTNING PROTECTION SYSTEM Supply fixing, testing and commissioning of 10mm dia and 600 mm length solid Aluminium blunt tip air temination with base to meet the requirements for IS/IEC 62305 and IEC 62561-2.
Supply, fixing, testing & commissioning of standing seam clamp as per IEC 62561-2.
Supply, fixing, testing & commissioning of 8 mm dia solid Aluminium Conductor.
Supply, fixing, testing & commissioning of conductor holding clamp suitable for aluminium conductor on concrete roof / wall with fasteners.
Supply fixing, testing and commissioning of Stainless Steel standing seam Clamping for conductor fixing on metal roof to meet the requirements for IS/IEC 62305.
Supply fixing, testing and commissioning of 8mm dia solid Aluminium conductor for down conductor as per IEC 62561-2.
Supply fixing, testing and commissioning of Down Conductor holder / saddle for GI flat.
Supply fixing, testing and commissioning of Straight Splicers for Aluminium Conductor.
Supply fixing, testing and commissioning of "T" Splicers for Aluminium Conductor.
Supply fixing, testing and commissioning of cross Splicers for Aluminium Conductor.
Supply& installation of 25 X 6 mm GI strip from Earth test link to the Earthing Grid and further the same strip shall be used for Making the Earthing Grid around the pheriphery of the building below ground level to meet the requirements of IS/ IEC 62305 and IEC 62561-2.
Supply, fixing, testing and commissioning of SDS clamp for conductor fixing on metal roof with fasteners.
Supply fixing, testing and commissioning of Test Link without enclosure.
Supply fixing, testing and commissioning of Electromechanical Lightning event counter - Display shows the number of lightning strikes, hour and date of lightning events. Buttons enable TIME/DATE setting and log viewing.Replaceable battery, working life minimum five years, Complies with IEC/EN 62561-6.
EXTERNAL ROAD LIGHTING - Supply, installation, testing & commissioning of 150W LED Street Light Premium LED Street light with following specifications: High-brightness White LEDs sources with high transmittance tempered glass cover and LENS on each leds, min system lumen output of 15000 lms, 5700K colour temperature . Life of atleast 50,000 hours at 70% lumen maintenance. Min. 10KV surge protection. The fixture should be made of Pressure die-cast aluminum with engraved company name & should have IP66 Class I protection complete as required As Trilux Endura Ind G3 15000857 ET/ Wipro LR02-182-XXX-57-DE / PHILIPS BRP322 LED 147 CW HE MR FG S3 XT or equivalent as per specification.
Supply, installation, testing & commissioning of LED-Compact spotlight for accent lighting. For direct mounting to firm underground. With ground stake (accessory) suitable for installation into substrate. Post fixing via stainless steel post strap (accessory). Clamping range Ø 40-130 mm. Optical system of aluminium with reflection-intensifying coating. With rotationally symmetrical wide light distribution. Maximum light intensity in beam angle 2 x 25°. beam angle 50°. Min. Luminaire luminous flux 4200 lm, Light colour neutral white, colour temperature 4000 K, Service life L 80 (t q 35 °C) = 50,000 h. Spotlight body of die-cast aluminium. Colour of luminaire body anthracite, similar to DB 703 with metal effect, highly weather resistant, powder-coated. Further colour variants possible from RAL or DB colour codes. With pan-and-tilt, Swivel range 195°, Rotation range 360°. Safety class (EN 61140): I, protection rating (DIN EN 60529): IP65. Factory-equipped with 5000 mm connection cable. With electronic driver , switchable. The LED system with control gear unit is suitable for operation on direct voltage supply grids. Make: Trilux Faciella 20 RB1R/4200-840 1G1 / Wipro LF04-501-XXX-30-DE or equivalent as per specification.
Supply , installation, testing & commissioning of LED Flood Light electrical Class I, with aluminium die cast with IP 65 optical compartment and the control gear shall have IP 65 tightness level. The Luminaire shall have min system lumen of 8800. The luminaires shall have CCT of 5700K. luminaires shall have direct access to gear and electronic compartment, a driver (efficiency > 90%*) with internal surge protection of 4/6 kV (in both Common and Differential modes), complete as required. As Trilux LFL 8000 865/ Wipro LF19-931-060-57-DE / Philips BVP122 LED110 CW FLNB FG XTFC or equivalent as per specification.
Supply, installation, testing & commissioning of Decorative post-top luminaire with convex, translucent diffuser, Parabolic mast bracket. Post-top luminaire for post spigot Ø 76 mm, Mast mounting via two stainless steel fixing screws in accordance with EN 60598-2-3. Also suitable for mounting to masts with spigot Ø 60 mm via reduction pieces to be ordered separately. Optical system with Multi-Lens Technology. Luminaire optic consists of highly efficient, UV and temperature-resistant lens systems. With rotationally symmetrical wide angle light distribution. Optimised for horizontal positioning of luminaire body. Further beam characteristics are available for flexible adaptation to customer-specific lighting tasks. Retrofitting a rear shielding is possible, With 6 LED modules. LED module consisting of four LEDs including optical system. Luminaire luminous flux min 3800 lm, Light colour neutral white, colour temperature 4000 K, Luminaire body of die-cast aluminium. Colour anthracite, similar to DB 703. Inclination angle can be adjusted Adjustment is lockable in 10° steps between 0° and 90°. with convex, translucent diffuser. Safety class (EN 61140): II, protection rating (DIN EN 60529): IP66, impact resistance level in accordance with IEC 62262: IK08/5 J. Gear tray with all electrical components and LED modules mounted as upper luminaire enclosure. Removable after releasing four fixing screws of V2A. Connection module in post mounting element, freely accessible. With 4-pole terminal to 2.5 mm² and insulated terminal point for earth conductor. With cable strain relief system. Surge voltage resistance 6 kV. With electronic transformer, switchable. Configurable ballast with luminous flux stabilising (CLO). Connected load at the end of service life: With intelligent power reduction via integral evaluation electronics. Reduction of luminaire luminous flux to 50 % for a time period of 7 hours (-2 h/+5 h). The luminaire complies with fundamental requirements of applicable EU regulations and product safety legislation and bears the CE symbol. As Trilux Publisca P1W-RBT-LRA/3800-740 6G1S ET / Wipro LP06-351-XXX-57-DE or equivalent as per specification.
Supply, installation, testing & commissioning of Ground-recessed spotlight for accent lighting, walkable and driveable. for ground recessing. On-site, a foundation suitable for the load with adequate drainage must be ensured with rotationally symmetrical narrow angle light distribution. beam angle 10°. 1 Chip on Board LED. Luminaire luminous flux min 2400 lm, Light colour warm white, colour temperature 3000 K, Service life L 80 (t q 25 °C) = 50,000 h, . Spotlight housing and cover ring of die-cast aluminium, colour deep black, similar to RAL9005, powder-coated. Cover ring is permanently fixed with locking screws and threaded inserts of stainless steel. Cover of 15 mm thick, hardened glass, clear. Can be rolled over at walking pace to 2000 kg. Safety class (EN 61140): II, protection rating (DIN EN 60529): IP68. Wired ready for connection. With connection cable fed outwards, sealed with appropriate protection rating. Inner connection compartment sealed with epoxy resin. With electronic driver , switchable. Make: Trilux 8521 RE2R/2400-830 1G1 ET / or equivalent as per specification.
Providing & erecting 8 m high (clear height) galvanised OCTAGONAL pole with foundation bolts having bottom of 135 mm above ground, top 70 mm above ground on foundation with single arm for mounting single street light including the terminal box for connection & including civil cost of making foundation.
Providing & erecting 8 m high (clear height) galvanised OCTAGONAL pole with foundation bolts having bottom of 135 mm above ground, top 70 mm above ground on foundation with double arm for mounting double street light including the terminal box for connection & including the civil cost of making foundation.
Providing & erecting 4 m high (clear height) galvanised OCTAGONAL pole with foundation bolts having bottom of 135 mm above floor, top 70 mm above floor on foundation including the terminal box for connection & including the civil cost of making foundation.
33 KV HT Panel For Detail please refer item no. 320 in Tender documents Volume - III
HT METERING PANEL For Detail please refer item no. 321 in Tender documents Volume - III
TRANSFORMERS INDOOR TYPE TRANSFORMER Supply, Installation, Testing & Commissioning of Oil type 2000 kVA, 33/0.415 kV 3 Phase, 50Hz, Dyn 11 vector group having impedance 7.5% copper wound with winding temperature indicator/controller , outdoor type Transformer with impedence as per IS1180(BEE-2STAR), The transformer shall be provided with +7.5% to -7.5% in steps of 2.5 % each On load tap changer with rotary links on HT side, having cable end boxes on HV side suitable for 3C x 300 sq.mm. XLPE cable of 11kV grade and 3200 Amp. bus trunking arrangement of LV side with neutral brought out separately , supplying and grouting of suitable MS channels with all accessories for mounting arrangement of incommer and confirming to IS 2026 (Part 1 to Part 5) & as per specification attached complete in all respects as required at site. The transformer shall be supplied with following Fitting & Accessories: All standard fitting viz Humidistat for Alarm and Trip Transformer Oil Temperature Alarm & Tripping Winding temperature relay unit with Alarm and trip Oil Level Low Alarm with trip Electronic temperature controlled with RTD. Gas Pressure Relays Buchholz relay of double float type with high gas pressure alarm & trip suitable for 24 volts DC supply. With wiring upto marshalling Box 1 No. 3200/5A, 5P10,10 VA, Protection class, CT after Neutral trifurcation point forbackup earth fault protection(51S). Outdoor type Marshalling box with RS-485 communication port for BMS integration to monitor all transformer parameters or having 2 No. potential free contact for alram, trip & annunciation (one for BMS and one for control system). The transformers shall have bi-directional rollers, winding temperature indicator, oil temperature indicator and Buchholz relay with wiring up to the marshalling box complete. The transformers shall have first filling of oil, weather proof HT cable box. The transformer shall have suitable disconnecting chamber at the ends with min 8mm thick non-magnetic gland plate , including M. S. channel and suitable size foundation complete with earth terminals/ lifting lugs and other standard accessories as required, as per relevant IS to successfully test & commission the Power Transformer as described above and technical specification
HSD STORAGE SYSTEM Underground Storage Tank Supply, Installation, Testing and commissioning of HSD Storage tank (Cylinderical and Horizontal) of 20 KL Cap.Shell to be fabricated from 5 mm thick M.S. Plate and flat ends from 8 mm thick M.S. Plate with M.S. Angle iron stiffenes as per specifications and approved for construction shop drawing as per IS - 10987 (Code of practice for design, fabrication, Testing and installation of underground steel storage tank for petroleum Products). Tank will be supplied with inlet/outlet, vent, nozzles ,manhole and suitable flame catcher, dip gauge & Calibration Chart. Tank will be supplied duly painted with anticorrosive black paint.
OIL PUMPS Supply, installation, testing and commissioning of electrically driven rotary gear oil pumps of cap. 225 LPM at 20 M Head; complete with flame proof motor, flame proof Isolator, common bed plate of requisite strength, fabricated out of M.S. Channel, Coupling & Coupling guard complete for transfering the HSD from Storage tanks to Day Oil tanks of DG. - 1W + 1SB
BUFFER & OVER FLOW TANK Supply, Installation, testing and commissioning of M.S fabricated 990 Ltr.Cap. Buffer tank for HSD ,as per specifications, fabricated out of 5 mm thick M.S. Sheet. The buffer tank shall be complete with all associated accessories and oil level controller for automatic operation of pump for transfering oil from bulk oil tank to buffer tank. Tank will be supplied with float & Board level indicator, duly painted with red oxide primer. The Buffer Tank will be installed at 2.0 Mtr. Level above F.L.on M.S. supports structure
Supply, Installation, testing and commissioning of M.S.Fabricated 990 Ltr. Cap.over flow Oil Tank for HSD ,as per specifications, fabricated out of 5 mm thk, M.S. Sheet. The Tank shall be complete with inlet, outlet drain, vent nozzles and manhole.The tank shall collect overflow oil from all the day oil tanks and from buffer tank and shall be complete with level controller for automatic operation of oil transfer pump when the level in the overflow tank is high.
FUEL FLOW RECORDING METER Providing and fixing of Oil Flow Meter 80 mm size installed in 80 mm dia pipe with bucket strainer, cast steel ball valve 80 mm dia flanged ends on each side and by Pass Valve for measuring Fuel at Unloading Point
Providing and fixing of Oil Flow Meter 50 mm size installed in 50 mm dia pipe with bucket strainer, cast steel ball valve 50 mm dia flanged ends on each side and by Pass Valve for measuring Fuel Consumption by DG Set - 1no. Meter for each DG set
PIPING & VALVES Supply and Installation of M.S. ERW "C" Class Pipe with fittings i.e. flanges,elbows, reducers etc. including painting of pipe with desired shade of synthetic enamel paint over a coat of red oxide primer as per I.S. Colour Code.
40 mm dia
50 mm dia
80 mm dia
Supply and Installation of Single piece fire safe design ball valve to pressure class 150 ASA ends flanged to class 150.
80 mm dia
25 mm dia
50 mm dia
Providing, Fixing, Testing and Commissioning of Non - Return Valve with Dual Plate of C I body, SS plates, flanged ends & PN 16 pressure rating for HSD system complete etc. as required.
Providing, Fixing, Testing and Commissioning Foot Valve of CI body, flanged ends with required accessories etc. complete as required.
65 mm dia
50 mm dia
Supply and Instalaltion of Float Valve with copper Ball and Brass rod. 50 mm
Providing, Fixing, Testing and Commissioning of dial type SS construction glycerine filled Pressure gauge with isolating valve and accessories etc. complete as required.
Auxillary Panel for Fuel Transfer Pump Supply of MCC Panel suitable for 415 V, 3 Phase, 4 Wire 50 HZ. Power distribution system. Panel shall be weather proof ,free standing, floor/wall mouting, sheet metal enclosed with aluminium bus bar and shall be powder coated in steel grey finish. Panel shall be suitable for Auto manual operation of HSD transfer pumps and shall be provided with all necessary/suitable switch gears. Panel shall be provided with 2 Nos. spare MCB'S for future use. DOL Starter suitable for motor mentioned below with Auto manual switch, overload relay and single phase preventing feature,shall also be provided.. On/Off/ Trip indication lamps, remote/local operation and indication and spare potential free contacts for building management system and operation of level controller.
DG SETS & EQUIPMENTS For Detail please refer item no. 336 in Tender documents Volume - III
500 kVA with Accoustic Enclosure
Accoustic Enclosure as per CPCB norms - 2000KVA
EXHAUST PIPING Supply, erection, testing and commissioning of exhaust piping of following sizes with welded joint including bends, MS pipe supports, clamps, dash fastener, nuts, bolts etc.,with first layer of insulation 50mm thick rock wool(96Kg/Cum) covered with 24 SWG aluminium sheet claddings etc. complete as required and as per specifications.
a) 400 mm dia. NB (Min. 5.20mm thick) after Y piece
b) 250 mm dia. NB (Min. 4.85mm thick)
c)300 mm dia. NB (Min. 4.85mm thick) for Y Piece Making of MS "Y" Piece -Before Silencer & After Silencer (as per manufacturers standrd design & site requirement )
Silencer Insulation Supplying and installing mineral wool insulation for silencer of DG sets thermal insulated mineral wool, minimum 75 mm thick(density 100Kg/cu metre) up to silencer. Wire chicken mesh over insulation and 24 gauge aluminium sheet wrapping to ensure that the temoertaure after insulation should not increase more than 10degC over site ambient at full load condition along with bends & flanges complete in all respect and as required.
Supply & installation of MS support with angle/chanel etc for above exhaust pipe of suitable height with Aviation Light and lightning arrestor fitting on the top complete as required in lieu of Structure supported Chimney.
Supply & laying from Control Cabling Between DG set and Synch Panel with its accessories such as MS spacers, saddles, screws etc. partly on trays & partly on slab/wall.
6 Core x 2.5Sq. Mm Copper Shielded Cable
3C x 2.5Sq. Mm Copper Armound Cable
12C x 2.5Sq.mm Copper Armoured Cable
24C x 1.5Sq.mm Copper Armoured Cable
Termination for above Control Cable using single compression type brass cable glands & copper crimping type lugs.
6 Core x 2.5Sq. Mm Copper Shielded Cable
3C x 2.5Sq. Mm Copper Armound Cable
12C x 2.5Sq.mm Copper Armoured Cable
24C x 1.5Sq.mm Copper Armoured Cable
PROTECTIVE EARTHING Supply & installation of 3mtr. X 3mtr. Earth mat made out of 75mm. X 10mm. GI earthing strip(including 4 nos. of 17.2mm. Dia and 3 mtrs. Earth electrode). The work shall include excavation of earth mat area, laying, cutting, bending and welding of 75mm. x 10mm. GI strip(500mm. below ground) as shown in the drawing. Also 4 nos. 17.2mm. dia and 3mtr. long copper bonded steel electrode installation at all the 4 corners of the earth mat as shown in the drawing).
Supply and laying, Testing and commissioning of copper/GI Strips/wire for interconnecting the earthing stations ,panels, DBs etc. of the following sizes in built up trenches /surface/wall/ground complete with holes & fixing, jointing / terminating accessories as per specifications & drawing as required. (Quantity shall be paid as per the actual measurement as executed, however direct measurement shall not exceed the quantity indicated in drawing approved) Note-1: In case of non-availability of any of the sizes mentioned above, next higher size available in market shall be provided at the same rate. Note-2: No additional payment will be made for providing Main Earth Terminals (made out of GI/Cu strips from within the above sizes). The METs will required to be fixed on walls as required and will be required to be provided with 12/16/20mm holes for connections of individual equipments including of other contractors.
32 mm X 3 mm copper strip on surface or in recess for connections etc. as required.
8 SWG dia G.I. wire on surface or in recess for loop earthing as required.
50mm. X 6mm. GI earthing strip including welding on surface/cable trays duly clamped & welded.
50mm. X 6mm. copper earthing strip on surface/cable trays duly clamped.
Supply & installation of Maintenance Free Earthing system comprising of 17.2 mm dia 3 mtr long Earth electrode of low carbon steel electrode with 250 micron copper bonding & Carbon based Ecosafe environment friendly backfill compound 50 pounds and suitable clamp of 17.2mm. tin coated brass clamp on both sides. The Earth pit should be covered with polyethylene weather proof chamber etc. as required & approved by the Engineer In charge.
H.T. CABLE LAYING & TERMINATIONS 33 KV Grade HT Cable Supply of following sizes of XLPE insulated PVC sheathed aluminium conductor armoured power cable of 33 kV grade conforming to IS 7098 (Part-II) amended upto date. 3 Core, 300 Sq.mm.
LAYING OF 33 KV GRADE HT CABLES Laying of one number XLPE power cable of 33 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Above 120 sq. mm and upto 400 sq. mm
Laying of one number XLPE power cable of 33 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 120 sq. mm and upto 400 sq. mm
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 33 kV grade as required. 3 Core 300 Sq.mm.
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 33 kV grade as required. 3 Core 300 Sq.mm.
Providing, laying and fixing following dia HDPE hume pipe(heavy duty) in ground complete with collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc. as required.
100 mm dia
150 mm dia
Supply & making of cable chambers of 1mtr. X 1mtr. X 1mtr. Size including brick work & cast iron cover.
BUS TRUNKING SYSTEM Supplying, installing by suspension on ceiling/along the wall, testing and commissioning of following capacity Sandwich Type Mains for use on 3 phase 4 wire 415 V, 50Hz A.C. supply with metal clad enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos. aluminium bus bars having current density of 130 A/ sq. cm at nominal current rating, necessary joints, elbow joints & expansion joints and bends, fire barrier at each floor, provision of tapping at every meter, adopter box and copper flexible for joints, continuous earthing with 2 Nos. aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required
630 A, Isc = 50 kA for 1 second
800 A, Isc = 50 kA for 1 second
1250 A, Isc = 50 kA for 1 second
1600 A, Isc = 50 kA for 1 second
3200 A, Isc = 50 kA for 1 second
LT CABLES & Termination Supply of following size of 1.1kv grade multicore aluminium conductor XLPE insulated and PVC sheathed armoured cable as per IS: 7098:1988 (Part - I) with upto date amendments.
3.5 core, 240Sq.mm
3.5 core, 185 Sq.mm
3.5 core, 150 Sq.mm
3.5 core, 95Sq.mm
3.5 core, 70Sq.mm
3.5 core, 50 Sq.mm
3.5 core, 35 Sq.mm
4 core, 16Sq.mm
4 core, 10Sq.mm
Supply of following size of 1.1kv grade multicore copper conductor XLPE insulated and PVC sheathed armoured COPPER cable as per IS : 7098:1988(Part - I) with upto date amendments.
4core, 240 Sq.mm
4core, 95 Sq.mm
3. core, 16 Sq.mm
3. core, 6 Sq.mm
3. core, 4 Sq.mm
3. core, 2.5 Sq.mm
4 core 25 sq.mm.
4. core, 6 Sq.mm
LAYING OF CABLES Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on cable tray as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
3.5 core, 240Sq.mm
3.5 core, 185 Sq.mm
3.5 core, 150 Sq.mm
3.5 core, 95Sq.mm
3.5 core, 70Sq.mm
3.5 core, 50 Sq.mm
3.5 core, 35 Sq.mm
4 core, 16Sq.mm
4 core, 10Sq.mm
Supply and making end termination with flame proof brass compression gland and Copper thimbles for XLPE insulated and PVC sheathed copper conductor cable of 1.1kv grade of the following sizes as required.
4. core, 240 Sq.mm
4 core, 95 Sq.mm
4. core, 25 Sq.mm
3. core, 16 Sq.mm
4. core, 6 Sq.mm
3. core, 6 Sq.mm
3. core, 4 Sq.mm
3. core, 2.5 Sq.mm
Cable Tray Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 75 mm depth X 2.0 mm thickness
450 mm width X 75 mm depth X 2.0 mm thickness
600 mm width x 75 m depth x 2 mm thickness.
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “bends” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 75 mm depth X 2.0 mm thickness
450 mm width X 75 mm depth X 2.0 mm thickness
600 mm width x 75 m depth x 2 mm thickness.
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Tee” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 75 mm depth X 2.0 mm thickness
450 mm width X 75 mm depth X 2.0 mm thickness
600 mm width x 75 m depth x 2 mm thickness.
GI Raceway & Junction boxes Supply, assembly and laying of under floor trunking made out of 1.6mm thick GI sheet complete with jointing sleeve, horizontal bends, vertical bends, level adjustment components and closer, vertical elbow, covers, access outlet. etc. complete with all other accessories under floor installation including cutting and chasing the floor/ or on surface, making good the same, placing in position and cleaning from inside complete etc. as required
300 mm wide x 38 mm deep raceway (3 compartment)
150 mm wide x 38 mm deep raceway (3 compartment)
Supply and fixing of pop up box (floor mounted) on floor including connection & accessories etc. as required including 2 nos. 6A. Sockets & 1 nos. 16A. Switch, 1 no. RJ45 socket, 1 no. RJ11 socket, 1 no. blank plate).
Providing and fixing 350 x 350 x 60-75 mm deep GI (hot dip galvanized) raceways made out of 1.6 mm thick sheet steel cross over box complete as required as per specification .
Providing and fixing 250 x 250 x 60-75 mm deep GI (hot dip galvanized) raceways made out of 1.6 mm thick sheet steel cross over box complete as required as per specification.
MAIN L.T. PANEL For Detail please refer item no. 368 in Tender documents & SOQ A. THE GENERAL DESCRIPTIONS FOR ALL LT PANELS B. BACK ACCESS PANELS WITH ACB's
BASEMENT PANEL For Detail please refer item no. 369 in Tender documents & SOQ A. THE GENERAL DESCRIPTIONS FOR ALL LT PANELS B. BACK ACCESS PANELS WITH ACB's
GROUND FLOOR PANEL For Detail please refer item no. 370 in Tender documents & SOQ A. THE GENERAL DESCRIPTIONS FOR ALL LT PANELS B. BACK ACCESS PANELS WITH ACB's
MEZZ. FLOOR PANEL For Detail please refer item no. 371 in Tender documents & SOQ A. THE GENERAL DESCRIPTIONS FOR ALL LT PANELS B. BACK ACCESS PANELS WITH ACB's
FIRST FLOOR PANEL For Detail please refer item no. 372 in Tender documents & SOQ A. THE GENERAL DESCRIPTIONS FOR ALL LT PANELS B. BACK ACCESS PANELS WITH ACB's
LIFT & ESCALATOR PANEL For Detail please refer item no. 373 in Tender documents & SOQ A. THE GENERAL DESCRIPTIONS FOR ALL LT PANELS B. BACK ACCESS PANELS WITH ACB's
HYBRID ( PASSIVE AND ACTIVE FILTER) PANEL 610 kVAR HYBRID PANEL-1 For Detail please refer item no. 374 in Tender documents & SOQ A. THE GENERAL DESCRIPTIONS FOR ALL LT PANELS B. BACK ACCESS PANELS WITH ACB's
310 kVAR CAPACITOR PANEL-2 For Detail please refer item no. 375 in Tender documents & SOQ A. THE GENERAL DESCRIPTIONS FOR ALL LT PANELS B. BACK ACCESS PANELS WITH ACB's
LIGHTING PANEL BASEMENT LIGHTING PANEL(MLDB-B) For Detail please refer item no. 376 in Tender documents & SOQ A. THE GENERAL DESCRIPTIONS FOR ALL LT PANELS B. BACK ACCESS PANELS WITH ACB's
GROUND FLOOR LIGHTING PANEL(MLDB-GF) For Detail please refer item no. 377 in Tender documents & SOQ A. THE GENERAL DESCRIPTIONS FOR ALL LT PANELS B. BACK ACCESS PANELS WITH ACB's
MEZANNINE FLOOR LIGHTING PANEL(MLDB-MEZZ.) For Detail please refer item no. 378 in Tender documents & SOQ A. THE GENERAL DESCRIPTIONS FOR ALL LT PANELS B. BACK ACCESS PANELS WITH ACB's
FIRST FLOOR LIGHTING PANEL(MLDB-FF) For Detail please refer item no. 379 in Tender documents & SOQ A. THE GENERAL DESCRIPTIONS FOR ALL LT PANELS B. BACK ACCESS PANELS WITH ACB's
UPS PANEL 1(MEZZ. FLOOR)(FOR EMERGENCY LIGHTING) For Detail please refer item no. 380 in Tender documents & SOQ A. THE GENERAL DESCRIPTIONS FOR ALL LT PANELS B. BACK ACCESS PANELS WITH ACB's
UPS PANEL(FOR IT SYSTEMS) For Detail please refer item no. 381 in Tender documents & SOQ A. THE GENERAL DESCRIPTIONS FOR ALL LT PANELS B. BACK ACCESS PANELS WITH ACB's
UPS PANEL(FOR DATA CENTRE) For Detail please refer item no. 382 in Tender documents & SOQ A. THE GENERAL DESCRIPTIONS FOR ALL LT PANELS B. BACK ACCESS PANELS WITH ACB's
RETAIL AREA PANEL For Detail please refer item no. 383 in Tender documents & SOQ A. THE GENERAL DESCRIPTIONS FOR ALL LT PANELS B. BACK ACCESS PANELS WITH ACB's
SUBSTATION ROOM PANEL For Detail please refer item no. 384 in Tender documents & SOQ A. THE GENERAL DESCRIPTIONS FOR ALL LT PANELS B. BACK ACCESS PANELS WITH ACB's
EXTERNAL LIGHTING PANEL For Detail please refer item no. 385 in Tender documents & SOQ A. THE GENERAL DESCRIPTIONS FOR ALL LT PANELS B. BACK ACCESS PANELS WITH ACB's
FEEDER PILLAR 1/2/3/4 For Detail please refer item no. 385 in Tender documents & SOQ A. THE GENERAL DESCRIPTIONS FOR ALL LT PANELS B. BACK ACCESS PANELS WITH ACB's
Auto Starting, Auto Synchronizing, Auto load sharing and load managing panel & DG Auxiliary Panel For Detail please refer item no. 385 in Tender documents & SOQ A. THE GENERAL DESCRIPTIONS FOR ALL LT PANELS B. BACK ACCESS PANELS WITH ACB's
MISCELLANEOUS - SUB STATION ITEMS Supplying of Rubber hand gloves suitable for 33 kV.as per IS Standard with test certificate.
Supplying and fixing of Shock treatment chart both in Regional, Hindi & English.and framed with 5mm thick glass as required.as per IS Standard.
Supply & fixing HT danger notice plate of 250 mm x 200mm, made of mild steel sheet of at least 2mm thick & vitreous enamelled white on both sides and with inscription in signal red colour on front side as required. (33 kV)as per IS Standard.
Supply & fixing MV danger notice plate of 200 mm x 150mm, made of mild steel sheet of at least 2mm thick & vitreous enamelled white on both sides and with inscription in signal red colour on front side as required.as per IS Standard.
Caution board printed in signal red "Man on Line".
Caution board printed in signal red "Don’t switch on".
Supply of First aid box containing material as prescribed by St. John Ambulance brigade OR Indian Red Cross conforming to IS 2217-1963 complete as required.
Supply and fixing of 33/12 KV grade class C nominal 3.0 mm + 10% thick insulated wit 1 mtr wide synthetic Mat conforming to IS 15652:2006 and meeting the requirments of IS 5216 (Part 1, 2 & 3) IS 8437, IEC-179 Pub-1, along- with suitable adhesive / chemibound, PU resin, waterproffinf compound and celing material as per recommendition of the manufacturaer and as per specifications and direction of Engineer-in- charge.
Supply and fixing of 3.3 KV grade class-A nominal 2.0 mm + 10% thick insulated syntheic mat conforming to IS 15652:2006 and meeting the requirments of IS 5216 (Part 1, 2 & 3) IS 8437, IEC-179 Pub-1, along-with suitable adhesive / chemibound, PU resin, waterproofing compound and celing material as per recommendition of the manufacturaer and as per specifications and direction of Engineer-in- charge
UPS SYSTEM Supply, installation, testing & commissioning of high performance IGBT based fully microprocessor controlled(three phase input & three phase output) online UPS system suitable for input & output parameters as per specifications. The UPS shall be modular type suitable for normal, emergency, recharge, by-pass and maintenance mode including bypass arrangement. The system is expandable in such as manner that addition of another module of similar capacity can double the system output with common by-pass. The UPS shall have a microprocessor based display and control panel. 3 x 30 KVA on line UPS , with IGBT based PWM technology ,3 phase input (415 V + 10% , 50 Hz + 3 % ), and three phase output (415 V + 3% , 50 Hz + 1 % ). The batteries shall be having high performance, hot swappable/scalable, user replaceable, internally fused pluggable type battery modules. UPS shall be housed in rugged enclosure made of MS sheet 2mm thick aesthetically finished duly pre treated and powder coated including digital metering , protections ,Digital Dislpay to moniter & control the various Parameter as per specification and approved drawing. -30 Minutes External battery Backup with 12V/150 Ah x 40Nos batteries, -100A STS(static transfer switch).
Supply, installation, testing & commissioning of high performance IGBT based fully microprocessor controlled(three phase input & three phase output) online UPS system suitable for input & output parameters as per specifications. The UPS shall be modular type suitable for normal, emergency, recharge, by-pass and maintenance mode including bypass arrangement. The system is expandable in such as manner that addition of another module of similar capacity can double the system output with common by-pass. The UPS shall have a microprocessor based display and control panel. 6X30 KVA on line UPS , with IGBT based PWM technology ,3 phase input (415 V + 10% , 50 Hz + 3 % ), and three phase output (415 V + 3% , 50 Hz + 1 % ). The batteries shall be having high performance, hot swappable/scalable, user replaceable, internally fused pluggable type battery modules. The UPS shall be housed in rugged enclosure made of MS sheet 2mm thick aesthetically finished duly pre treated and powder coated including digital metering , protections ,Digital Dislpay to moniter & control the various Parameter as per specification and approved drawing. -30 Minutes External battery Backup with 12V/150 Ah x 40Nos batteries, -300A STS(Static Transfer Switch).
Supply, installation, testing & commissioning of 5 KVA on line UPS , with IGBT based PWM technology ,1 phase input (230 V + 10% , 50 Hz + 3 % ), and single phase output (230 V + 3% , 50 Hz + 1 % ) with 30 minutes battery backup. The batteries shall be having high performance, hot swappable/scalable, user replaceable, internally fused pluggable type battery modules.It shall be housed in rugged enclosure made of MS sheet 2mm thick aesthetically finished duly pre treated and powder coated including digital metering , protections ,Digital Dislpay to moniter & control the various Parameter as per specification and approved drawing.
Supply, installation, testing & commissioning of high performance IGBT based fully microprocessor controlled(three phase input & three phase output) online UPS system suitable for input & output parameters as per specifications. The UPS shall be modular type suitable for normal, emergency, recharge, by-pass and maintenance mode including bypass arrangement. The system is expandable in such as manner that addition of another module of similar capacity can double the system output with common by-pass. The UPS shall have a microprocessor based display and control panel. 30 KVA on line UPS , with IGBT based PWM technology ,3 phase input (415 V + 10% , 50 Hz + 3 % ), and three phase output (415 V + 3% , 50 Hz + 1 % ) with 30 minutes battery backup. The batteries shall be having high performance, hot swappable/scalable, user replaceable, internally fused pluggable type battery modules. The UPS shall be housed in rugged enclosure made of MS sheet 2mm thick aesthetically finished duly pre treated and powder coated including digital metering , protections ,Digital Dislpay to moniter & control the various Parameter as per specification and approved drawing.
FIREALARM SYSTEM Supply, Installation, Testing & Commissioning of Microprocessor based 7 loop minimum (4.3" touch screen LCD display), Networkable analogue addressable type fire alarm control panel with minimum 600 character display, The panel should be equipped with sufficient numbers of loop with 10-20% spare capacity having integration voice evacuation with amplifier as per the quantity and fire fighting telephone system rail mounted with each loop shall have a capacity of 240 analog addressable devices in one loop. Four access levels, capable of taking Flash Scan devices, flash EPROM sufficient numbers of programmable relay controls for controlling AHUs, pressurization fans, ventilation fans at fire pump room, monitoring of fire sprinkler and fire hydrant pump, addressable 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and then be capable of operating the system for 2 hours during an emergency conditions as required. The Panel shall have BACKNET CARD for integration. (UL 9th Edition Approved and NFPA/ EN54 LPCB or latest amended upto date)
Supply, Installation, Testing & Commissioning of networkable 4.3 " Touch Screen Microprocessor based 2 loop intellegent analogue Addressable Type Fire Alarm Control Panel, with minimum 600 character LCD display ,The panel should be equiped of Sufficiant number of loops with loop capacity to take 250 total intellegent addressable detectors & devices in one loop. (UL 9th Edition Approved and NFPA // EN54 / or Latest ammended upto date LPCB )
Supply, Installation , Testing & Commissioning of the GUI based main network Fire Detection must be capable of graphically representing each facility being monitored with floor plans and icons depicting the actual locations of the various systems; and / or sensors’ locations. The GUI software shall be located in control room in one of the Floors and shall monitor and control all the Floor Fire Detection, Digital voice evacuation system and 2 way communication panel connected with each other through fibre optics. The software shall provide the facility to Monitor & Control all the Digital voice evacuation system as well as 2 way communication from main control room using voice signals over Fire Network along with the Fire detection signal. The software shall be capable of broadcasting on Voice over IP and complete as per the specification. (UL 9th Edition Approved and NFPA compliant) Operator work station with PC having Intel Pentium I7 Processor including Serial ports (RS232) and USB ports and following accessories etc. complete with software all as specified. 8 Gigabytes of RAM memory 2 TB of hard disk space DVD ROM 21” LED colour monitor Mouse with Mouse Pad Standard Key Board Latest Windows Operating System Compatible Fire Alarm System Control Software Laser Printer colour A4- 1 No Software for Automatic Fire Detection and Alarm System Software for Aspiration Based Smoke Detection System UPS 800 VA or better
Supply, installation, testing and commissioning of 100 meter Addressable MOTORISED AUTOALIGN Beam Detector with mounting reflector and beam extender to cover the distance. (UL 9th Edition Approved and NFPA).
Supply, installation, testing and commissioning of Addressable Acclimate Smoke Detector with mounting based LED with Electronic/Rotary switch Addressing Feature to programme the detectors. Complete as required to be installed under/above false ceiling, roof and concealed space, etc. interconnecting to loop cable complete as required.(UL 9th Edition Approved and NFPA / EN54 OR LATEST.
Supply, installation, testing and commissioning of Addressable type Heat Detector (Fixed cum- rate of rise type at 15 degree farehiet or better) with fixed temperature range upto 57o C complete with all fixing accessories like base, base box, self adhesive sticker indicating loop number and address etc. to be installed under/above false ceiling, roof and concealed space, etc. interconnecting to loop cable complete as required..(UL 9th Edition Approved and NFPA / EN54 OR LATEST.
Supply, Installation, Testing and Commissioning of Addressable type manual call (Reseatable) Station complete with all accessories ( As per IS 2189), Manual call point shall be located preferably near entry to staircases at various levels and shall be fixed at a height of 1.4 m above the surrounding floor level. as per specifications. (UL 9th Edition Approved EN54 and NFPA compliant or IS 2189 latest amended upto date) complete as required.
Supplying, installation, testing & commissioning of (CO/HEAT) Addressable type Multi Criteria Multi sensor detector complete as required to be installed under/above false ceiling, roof & concealed space etc. interconnecting to loop cable complete as required.((UL 9th Edition Approved and NFPA) / EN54.
Supply, installation, testing and commissioning of addressable aspiration detector with Based Aspiration Detection Unit with three stage filteration for aspiration chamber with area coverage of 20000 Sq. Feet with sensitivity ranging from 0.0005% Obs/ft to 6.00% Obs/ft. The main fire alarm panel shall recieve all the signals from the unit and the main fire alarm panel shall control the aspiration system directly for better response. The cost will include Power Supply Unit for above detector 230 V AC to 24 V DC 1.5 Amp with 24 hour battery backup in normal condition and 30 minutes in alarm condition etc. complete with as per specifications. (UL 9th Edition Approved and NFPA compliant or latest amended upto date)/EN54
Supply, Installation, Testing and Commissioning of End Cap for the Aspiration system.
Supply, Installation, Testing and Commissioning of 25 mm FRLS UPVC pipe for Aspiration System with ONE mm Drill at equal distance mounting on above ceiling with all required accessories.
Supply, installation, testing and commissioning of Addressable Strobe loop powered. The strobes shall be synchronized for better evacuation as per specification complete as required.(UL LISTED , NFPA or EN54 LATEST)
Supply, Installation, Testing & Commissioning of addressable sounder with 20 Hz to 20KHz operating frequency with supervised power supply with distinct sound patterns/ multitone to indicate Exit doors and direct occupants for safe and fast evacuation , complete with MS Powder coated Junction Box for mounting on Surface, Cable lugs at Ends, cable compression glands, cable tags and Ferruling as specified in NFPA 72 - 2016 edition (Clause A.18.4.7) and complete as per the specification. (UL Listed, NFPA compliant or latest amended upto date) / EN54
Supply, installation, testing & commissioning of Fault Isolator Module as per specifications.(UL 9th edition Approved and NFPA / EN54) complete as required.
Providing, installation, testing & commissioning of Control relay Module (for control of AHU, ventilation fan etc) as per specifications.(UL 9th edition Approved and NFPA/EN54) complete as required.
Supply, installation, testing & commissioning of UL listed monitor module with (for monitoring different electrical/mechanical device like flow switch etc.) as per specifications.(UL 9th edition Approved and NFPA) complete as required.
Supply, Installation, Testing and Commissioning of 2 way communication Fire Fighter's Telephone Jack with control odule fitted on wall including the cost of breaking and making good the wall wherever required, complete in all respects as per specifications. (UL 9th edition Approved and NFPA/EN54)complete as required.
Supply, Installation, Testing and Commissioning of 2 way communication Fire Fighter's Handset complete with all accessories as per specifications.
Supply and laying of 2 core 1.5 sq.mm. FR LSZH, stranded copper conductor armoured cable 1100 V grade as per IS 7098 (part 1)1988, amended upto date as required.
Supply and laying of 4 core RS 485 FR LSZH, stranded copper conductor armoured cable 1100 V grade as per IS 7098 (part 1)1988, amended upto date as required.
FOR GAS SUPRESSION SYSTEM FOR DATA SYSTEM NOVEC 1230 BASED FIRE SUPPRESSION SYSTEM COMPRISING OF PROVIDING ALL MATERIAL, EQUIPMENT, INSTALLATION, LABOUR, TESTING, COMMISSIONING & HANDING OVER OF THE ENTIRE SYSTEM, WITH THE FOLLOWING COMPONENTS: Providing & fixing Seamless Steel Cylinder Complete with Pneumatical Valve Assembly arrangement, supervisory switch connection for minitoring cylinder pressure, in compliance with Chief Controller of Explosive, Nagpur with electric & pressure operated control heads as per requirement (Master/Slave Actuation Packages) a safety burst disc, and any other accessories to make the cylinder completely operational including Flexible Actuation Hose (directed to a pressure operated control head on each cylinder valve using actuation hose), container strap, structural supports etc. 140ltr Capacity
Supply & installation of Slave Cylinders of 140 Ltr capacity complete with Cylinder Valve ,Contact pressure Gauge , Syphon Tube and Safety Cap. 140ltr Capacity
Supply & installation NOVEC-1230 Agent filled in above cylinder (Kgs).
Supply & installation of Accessories for Master Cylinder.
Manual Release Device
Discharge Hose - DN 50
Actuation adapter
Supply & installation of Accessories for Slave cylinder.
Pnuematic Release Device
Actuation hose
Discharge hose - DN 50
Supply & installation of Nozzles. MX 1230 Nozzles--180 degree - 1''
Supply & installation of Safety device malfunction pressure SFD DN 4.
Supply & installation of Manifold Check valve.
Supply & installation of Accessories such as
Cylinder Strap
Caution advisory signages
Supply & installation of Piping, Sch 40; ASTM A106 Gr B, as per flow calculations for the specific hazard volume and stand to hold,position & Support the Manifold and Piping properly.
Supply installation testing and commissioning of 4 zone Gas Release Panel facility to connect Manual Abort/Release switches. The Panel shall provide Potential free contacts for First knock, second knock, Trouble / Fault Status., Battery charger & batteries.
Supply & installation of Manual Abort Stations Semi Flush Mounting Re-settable (Non-Breaking Glass), Supplied with Special Reset Tool - Compatible with both C & DC Series (Certified by LPCB).
Supply & installation of Manual Release Stations Semi Flush Mounting Re-settable (Non-Breaking Glass), Supplied with Special Reset Tool - Compatible with both C & DC Series (Certified by LPCB).
Supply & laying of 2 core x 1.5 mm2, Multistrand Copper, FRLS Armoured cable, RED in Colour, laid on surface with GI saddle-spacers every 0.3 meters. Complete with GI Junction Box, lugs, cable compression glands, cable tags and Ferruling.
Supply, Installation, testing & commissioning of UL listed / LPCB approved & NFPA 72 compliant Intelligent Analogue optical smoke Detector with floating sensitivity Complete with all accessories like base, base box, etc. to be installed under / above false ceiling, roof and concealed space, etc.
Supply, installation, testing & commissioning of Response Indicators.
GAS SURESSION SYSTEMS FOR GAS PANELS Supply, Installation, Testing & Commissioning of Microprocessor based 10 loop minimum (5.1" touch screen LCD display), Networkable analogue addressable type fire alarm control panel with minimum 600 character display, The panel should be equipped with sufficient numbers of loop with 10-20% spare capacity having seamless integrated voice evacuation with amplifier as per the quantity and fire fighting telephone system rail mounted with each loop shall have a capacity of 250 analog addressable devices in one loop. Four access levels, capable of taking Flash Scan devices, flash EPROM sufficient numbers of programmable relay controls for controlling AHUs, pressurization fans, ventilation fans at fire pump room, monitoring of fire sprinkler and fire hydrant pump, addressable 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and then be capable of operating the system for 2 hours during an emergency conditions as required. The Panel shall have BACKNET CARD for integration. (UL 9th Edition Approved and NFPA/ EN54 or latest amended upto date)
Supply, installation, testing & commissioning of FireTraceTube for automatic fire detection and suppression system made by special modified Polyamide (PA), Color Red RAL300, High grade quality, Inner diameter 4mm, OuterDiameter 6 MM, Pressurised with dry Nitrogen at 13.5/10.5 bar pressure UL approved as per UL 521 STANDARD FOR HEAT DETECTORS FOR FIRE PROTECTIVE SIGNALING SYSTEMS.
Supply, installation, testing & commissioning of FireTrace T Connection, Brass, Nickle plated, for 4x6 mm Sensor Tube, quick and easy disassembly using special tool, External Diameter tube 6mm.
Supply, installation, testing & commissioning of FireTrace End of Line Plug for Automatic fire suppression tube used for fitting at the tube end to terminate the point. Fitting made by brass nickel plated material.
Supply, installation, testing & commissioning of FireTrace End of Line adapter with Pressure gauge for Automatic fire suppression tube used for fitting at the end of the tube for pressurizing and re suppression tube used for fitting at the end of the tube for pressurizing and re pressurizing the tube includes check Valve, Pressure Gauge and fitting to connect to sensor tubing. Tube connection 6mm.
Supply, installation, testing & commissionong of FireTrace Pressure Switch to monitor Pressure drop in the tube, switch point 5 Bars.
Supply, installation, testing & commissioning of MASTER CONTROL UNIT.
DOUBLE LEAF AUTOMATIC SLIDING DOOR (Door Hardwares + Glass Supply+ Installation Cost Only) Design, engineer, furnish, fabricate, package, deliver (to jobsite) and Install: Façade mounted Double Leaf automatic sliding door from approved company & make supported from the glass as per dimension and specification as indicated in tender drawings and technical specifications.Rate shall include landing cost on site. Automatic sliding glass door with stainless steel 316 hardware and accessories along with door closer,Guider of approved make and stainless steel 316 grade handles. ( Door Opening : 2400 x 2440mm ) GL-05:Vision glass panels comprising of hermetically-sealed 13.52mm Laminated glass : 6mm thick clear Fully Tempered (Heat Soak Test) glass + 1.52mm thick Clear Sentry Plus Interlayer + 6mm thick clear Fully Tempered (Heat Soak Test) glass.The laminated glass shall be assembled in the factory/workshop of the glass processor.Rate shall be including wastage and landing cost. Mode of Measurement: For payment only the actual area of glass panels shall be measured in sqm.
AIRPORT ENTRY PORTAL 1. Sign face - 3mm thick Aluminium sheet fabrication with a white retroreflective film, fixed to horizontal structural truss. Graphics in plotter RAL 5013 exterior grade opaque vinyl pasted over white retroreflective vinyl. 2. Sign structure - MS square post 300x300 and mounting square sections, hotdipped galvanised and PU Painted to match RAL 9006 grouted in ground. Spanning truss shall be designed for each. Mounting square section span and the wind loads.
Vehicular Directional Sign- Pole mounted 1.Sign face - 3mm thick aluminium with a white retro-reflective film. Graphics in Plotter RAL:5013 Exterior grade opaque vinyl pasted over white retro-reflective vinyl. 2. Sign frame - M.S.frame 50x50mm hotdipped galvanised 3. Sign structure - MS square post 125x125 and mounting square sections 75x75mm, hotdipped galvanised and PU Painted to match RAL 9006 grouted in ground. 4. Cover plate - 225x225mm, 5 mm thick cover plate mounted on the flooring.
Multiple of width- 1
Multiple of width- 2
Multiple of width- 3
Vehicular Directional Sign Portal 1. Sign face - 3mm thick Aluminium sheet fabrication with a white retroreflective film, fixed to horizontal structural truss. Graphics in plotter RAL 5013 exterior grade opaque vinyl pasted over white retroreflective vinyl. 2. Sign structure - MS square post 300x300 and mounting square sections, hotdipped galvanised and PU Painted to match RAL 9006 grouted in ground. Spanning truss shall be designed for each Mounting square section span and the wind loads.
Pedestrian Directional Sign 1.Sign face - 3mm thick aluminium with a white retro-reflective film. Graphics in Plotter cut RAL:5013 Exterior grade opaque vinyl pasted over white retro-reflective vinyl pasted over 3mm thick aluminium sheet. 2. Sign frame - M.S. frame 50x50mm wide, hotdipped galvanized 3. Sign structure - M.S. hollow box section 75x75 and mounting square sections, hotdipped galvanised and PU Painted to match RAL 9006 grouted in ground. All hardware used for fixing of sign shall be Stainless steel. 4. Cover plate - 5 mm thick cover plate mounted on the flooring.
Traffic Statutory Sign 1.Sign face - 3mm thick aluminium on two sides of the sign structure with a white retroreflective film and red Pantone 485C and black Pantone 6C vinyl. 2. Sign structure - MS square post 50x50, hotdipped galvanised and powder coated to match RAL 9006 grouted in ground. All hardware used for fixing of sign shall be Stainless steel.
Traffic Information Sign 1. Sign Structure : 25 x25 M.S. Frame hotdipped galvanized 2. Sign Face: Graphics in Plotter cut RAL:5013 Exterior grade opaque vinyl pasted over white retro-reflective vinyl pasted over 3 mm thick aluminium sheet. The size of the sign is A1 (594 x 841 mm).
Arrival/Departure Zone Marker 1. Sign Face – Entire Sign face all 4 sides, to be made of printed vinyl flex of high quality, with the letters/pictogram to match Pantone Black 6C and the rest of the vinyl to match Pantone Yellow C. To be mounted onto framework using appropriate clips and edge ties to be perfectly taut with no sagging 2. Suspender - Stainless steel Hollow section100mm OD mounted on slabs/beams/walls. 3. Sign Frame-25mm x 25mm m.s. square sections welded together to form a framework. 4. Stretching member-8mm thick acrylic strip fixed to the sign frame to help stretching the sign face. All hardware used for fixing of sign shall beStainless steel.Secret fixing methods should be used to fix parts together. Lighting : All internal illumination shall be using Power LED Lights with electronic controllers, having even spread and overlaps to avoid banding and dark spots.
Entry/Exit Announcer 1. Portal – The portal frame is site dependent. Wherever existing portal exists, the portal to have Yellow Pantone Yellow C opaque vinyl stuck over. In case of no portal, 50mm wide portal has to be fabricated from 3mm thick ACP, with Yellow Pantone 116C Vinyl Stuck over it. 2. Sign Letters-50mm thk 3D cut letters in black glossy acrylic. 3. Sign Structure (in case of no portal) - The internal structural frame to be made from 50 mm MS box section hot-dipped galvanized PU Painted in colour RAL 9006.
Facility Announcers - Floor Mounted 1. Sign Box – Entire Sign face all 4 sides, White translucent 040 acrylic, 5mm thick with backlighting. 2. Graphics - Plotter cut vinyl Pantone Yellow C, Blockout vinyl for text Pantone Black 6C, pasted over acrylic with white diffuser film on inside face. 3. Bottom panel – Bottom MS Panel powder coated in colour to match Vinyl Black of Pantone Black 6C. 4. Sign Structure: M.S. hollow box section 75x75 hotdipped galvanised and PU Painted to match RAL 9006 fixed to ground. Lighting : All internal illumination shall be using Power LED Lights with electronic controllers, having even spread and overlaps to avoid banding and dark spots
Terminal Building Announcer 1.Letter face- White translucent 040, 5mm thick acrylic. complete face shall be covered with translucent vinyl film to match Blue Pantone 541C. 2. Back channel - A channel made out of aluminium to receive the front acrylic and house the controller and LEDs 3. Spacer - Recommended for use for mounting the larger text on the glazing frame Mounting and structure Lighting : All internal illumination shall be using Power LED Lights with electronic controllers, having even spread and overlaps to avoid banding and dark spots.
Directional Signs Artwork for Directional Signs Ceiling Hung Directional Sign 1. Sign face - Graphics - Plotter cut Blockout vinyl Pantone Black 6C, vinyl for text Pantone Yellow C or Cyan 311C as per graphics, pasted over 8mm thick White translucent 040 acrylic. 2. Sign frame - 50mm wide aluminium extrusion with inbuilt frame to recieve the sign face. The panel should be made easily openable for maintainance. 3. Sign Structure: Framewrok of aluminium 25mmx 25mm hollow squrae sections Suspender - Stainless steel 25x25mm Hollow sections mounted on slabs/beams/walls. All hardware used for fixing of sign shall be Stainless steel. Lighting : All internal illumination shall be using Power LED Lights with electronic controllers, having even spread and overlaps to avoid banding and dark spots
Multiple of width- 1
Multiple of width- 3
Multiple of width- 4
Multiple of width- 5
Wall Mounted Directional Sign 1. Sign Structure - 50mm wide aluminium extrusion with inbuilt frame to recieve the sign face. The panel should be made easily openable for maintainance. 2. Sign Face: Graphics - Plotter cut Blockout vinyl Pantone Black 6C, vinyl for text Pantone Yellow C or Cyan 311C as per graphics, pasted over 8mm thick White translucent 040 acrylic. Graphics as per 2.1 Lighting : All internal illumination shall be using Power LED Strip Edge Lights with electronic controllers, having even spread and overlaps to avoid banding and dark spots.
Multiple of width- 1
Multiple of width- 3
Multiple of width- 4
Multiple of width- 6
Wall Projected Directional Sign 1. Sign face - Graphics - Plotter cut Blockout vinyl Pantone Black 6C, vinyl for text Pantone Yellow C or Cyan 311C as per graphics, pasted over 8mm thick White translucent 040 acrylic. 2. Sign Structure - 50mm wide aluminium extrusion with inbuilt frame to recieve the sign face. The panel should be made easily openable for maintainance. All hardware used for fixing of sign shall be Stainless steel. Projection supported of small plates 8mm thick and tension rod with threaded ends and turnbuckles for adjustments. Secret fixing methods should be used to fix parts together. Lighting : All internal illumination shall be using Power LED Strip Edge Lights with electronic controllers, having even spread and overlaps to avoid banding and dark spots.
Multiple of width- 1
Multiple of width- 4
Facility Announcer Signs Wall Mounted Facility Announcer Sign 1. Sign Face: Graphics - Plotter cut Blockout vinyl Pantone Black 6C, vinyl for text Pantone Yellow C or Cyan 311C as per graphics, pasted over 8mm thick White translucent 040 acrylic. 2. Sign Frame - 50mm wide aluminium extrusion with inbuilt frame to recieve the sign face. The panel should be made easily openable for maintainance. Lighting : All internal illumination shall be using Power LED Lights with electronic controllers, having even spread and overlaps to avoid banding and dark spots.
Door Mounted Facility Announcer Sign 1. Sign Structure -25mm wide aluminium extrusion with inbuilt frame to recieve the sign face. The panel should be made easily openable for maintainance. 2. Sign Face: Graphics - Plotter cut Blockout vinyl Pantone Black 6C, vinyl for text Pantone Yellow C or Cyan 311C as per graphics, pasted over 6mm thick White translucent 040 acrylic.
Boarding Gates - Wall Mounted 1. Sign face: Graphics - Plotter cut Blockout vinyl Pantone Black 6C, vinyl for text Pantone Yellow C or Cyan 311C as per graphics, pasted over 8mm thick White translucent 040 acrylic. 2. Sign Frame - 50mm wide aluminium extrusion with inbuilt frame to recieve the sign face. The panel should be made easily openable for maintainance. LED 32” display:FIDS/Information Panel- Digital Panel mounted on cross ties internally, with brackets designed for the specified sizes. Lighting : All internal illumination shall be using Power LED Strip Edge Lights with electronic controllers, having even spread and overlaps to avoid banding and dark spots.
Belt No. Sign 1. Sign Face – Entire Sign face all 4 sides, White translucent 040 acrylic, 8mm thk. Graphics - Plotter cut vinyl Pantone Yellow C, Blockout vinyl for text Pantone Black 6-C, pasted over acrylic with white diffuser film on inside face. 2. Bottom panel – Bottom MS Panel PU Painted in colour to match Vinyl Black of 95%(Pantone Black 6C). 3. Sign structure - All structural members in Stainless steel 75x75mm Hollow box section brush finish, base plate embedded below the floor finish and provided with a floor trim ring. All hardware used for fixing of sign shall be Stainless steel All internal illumination shall be using Light Guide Panels(preferred) or LED Strip Edge Lights with electronic controllers, having even spread and overlaps to avoid banding and dark spots.
Utility Signs Washroom / Drinking Water/ Baby Care Type 1 - Wall Projected 1. Sign Internal Structure -50mm wide aluminium extrusion with inbuilt frame to recieve the sign face. The panel should be made easily openable for maintainance. 2. Sign face - Graphics - Plotter cut Blockout vinyl Pantone Black 6C, vinyl for text Pantone Yellow C or Cyan 311C as per graphics, pasted over 8mm thk acrylic. All hardware used for fixing of sign shall be Stainless steel. Projection supported internally by side mounting of SS frame. Lighting : All internal illumination shall be using Power LED Lights with electronic controllers, having even spread and overlaps to avoid banding and dark spots. Type 2 - Wall Mounted 1. Sign Internal Structure - 50mm wide aluminium extrusion with inbuilt frame to recieve the sign face. The panel should be made easily openable for maintainance. 2. Sign Face:Graphics - Plotter cut Blockout vinyl Pantone Black 6C, vinyl for text Pantone Yellow C or Cyan 311C as per graphics, pasted over 8mmthk acrylic. Lighting : All internal illumination shall be using Power LED Lights with electronic controllers, having even spread and overlaps to avoid banding and dark spots.
Service Area 1. Sign Face: Digitally printed Graphics pasted on 3mm thick black acrylic mounted on walls/ calddings/ panelllings using VHB Tape
Lift Number sign 1. Sign Structure - 25mm wide aluminium extrusion with inbuilt frame to recieve the sign face. The panel should be made easily openable for maintainance. 2. Sign Face:Graphics - Plotter cut Blockout vinyl Pantone Black 6C, vinyl for text Pantone Yellow C or Cyan 311C as per graphics, pasted over 040acrylic. Lighting : All internal illumination shall be using Power LED Lights with electronic controllers, having even spread and overlaps to avoid banding and dark spots.
Statutory Signs Poster Size A0 1. Sign Face: Digitally printed Graphics pasted on 3mm thick acrylic mounted on walls/ calddings/ panelllings using VHB Tape
Poster Size A1 1. Sign Face: Digitally printed Graphics pasted on 3mm thick acrylic mounted on walls/ calddings/ panelllings using VHB Tape
Poster Size A2 1. Sign Face: Digitally printed Graphics pasted on 3mm thick acrylic mounted on walls/ calddings/ panelllings using VHB Tape
Poster Size A4 1. Sign Face: Digitally printed Graphics pasted on 3mm thick acrylic mounted on walls/ calddings/ panelllings using VHB Tape
Emergency Direction Signs - Illuminated 1. Sign Frame - 1.5mm CRCA MS powder coated white 2. Sign Face - Laminated acrylic 6mm thick with graphics in white and green transluscent vinyl on the inside face of the glass 3. Illumination : All Internal illumination using LED lamps connected to a UPS with a min 1.5hr backup 4. Sign Fixing - Suspenders and projecting pipes shall be stainless steel to match other similar hardware 35mm dia.
Emergency Signs - Fire Life Safety Layout All signs are digitally printed using artworks made specific to each location. Laminated Digital prints on photoluminiscent self adhesive film mounted on 3mm thick white acrylic plate. At location with available flat and non-porous surfaces like glass laminate panels, cladding- the printed vinyl can be applied directly
WATER COOLED CENTRIFUGAL CHILLER WITH VFD (R-134A) For Detail refer to Item no. 472 in volume - III
Supply, installation, testing, commissioning of Air Source Heat Pump operating on 415+/- 10% Volts, 3 Phase, 50 Hz AC Supply complete with Screw Compressor with capacity control Shell and Tube Condenser, Copper Tubed Aluminium finned Evapourator Coil with fans motors, contactors, electrical controls, all connected with copper refrigerant piping and complete with expansion device and controls and complete with electrical switchgear, all factory assembled, piped and wired,and with refrigerant charge and oil of following parameters : Heating Capacity 160 KW Air on Condenser 10 Deg C Hot Water In 40 Deg C Hot Water out 45 Deg C Refrigerant R 134a
Primary Chilled water pumps for 700 TR Water cooled Centrifugal Chillers with insulation for following capacity Water flow rate = 1608 USGPM Quantity 1 Working + 1 Standby Head = 30 Ft. of water ( as required)
Secondary Chilled water pumps with insulation with following capacity Water flow rate = 804 USGPM Quantity 2 Working + 1 Standby Head = 120 Ft. of water column (As required)
Control panel with VFD & Differential pressure switch/ pressure sensor for operation, sequencing & modulating the pumps suitable for 4-20mA / 0-10V signal from chiller plant optimizer. Also VFD shall provide all feedback & data back to chiller plant optimizer THiD (IEEE519-1992) - 35% at Full Load EMC filter category - C2 PID controller feedback loops - 2 (Min)
Condenser water pumps for 700TR Water cooled Centrifugal Chillers as follows: Water flow rate = 2100 USGPM (1W+1S) Head = 80 Ft.of water column (As required) Quantity 1 Working + 1 Standby
Hot Water pumps for hot water duty Flow 120 usgpm ( 26 Lit / Sec ) Head 120 Ft of water column (As required) Quantity 1 Working + 1 Standby
AIR HANDLING UNITS Supply, Installation, Commissioning & Testing of factory built floor mounted Double Skinned type horizontal/vertical Air Handling Units consisting of 25mm thick panels consisting of pre plasticized G.I. casing of thickness 0.8mm outside layer between them by injection moulding machine, complete with blower section with eliminators,cooling coil section with aluminum finned copper tubes (copper tube thickness shall not be less than 0.5mm) cooling coil of 6/4 rows deep,filter section with 50mm thick metal viscous / washable synthetic type air prefilters, belt drive package with TEFC drive motorof effeciency class IE3 suitable for 415+/- 10% volts,50 Hz, 3 phase AC supply suitable design for VFD application drain connections,stanless steel drain pan with PUF insulation, 150mm dia dial type pressure guages 2nos. and industrial type thermometers 2 nos. at the inlet and outlet of coil auot purge valve wherever required, necessary vibration isolators arrangement etc. complete as per specifications. Contractor shall design the chilled water coil according to the following conditions: ADP - 54 deg F Coil air entering temperature 75 deg F DB/ 63.8 deg F WB Coil air leaving temperature 56 deg F DB/ 54.8 deg F WB Chilled water temperature( 7.5 deg C/ 45.5 deg F) / (12.5 deg C / 54.5 deg F) Hot water temperature( 45 deg C/ 113 deg F) / (40 deg C / 104 deg F) a) Fan section with fire rated flexible canvas connections on supply and return b) Cooling coils c) Heating coils d) Filters - MERV8 e) Ultraviolet lamps (as specified) f) S.S Insulated Drain pan g) Mixing box section h) Necessary vibration isolators & supporting frame as required for AHU
Air handling unit - 1 WITH 31700 CFM / 6 ROWS / 80 mm static
Air handling unit - 2 WITH 18400 CFM / 6 ROWS / 80 mm static
Air handling unit - 3 WITH 16200 CFM / 6 ROWS / 80 mm static
Air handling unit - 4 WITH 27800 CFM / 6 ROWS / 80 mm static
Air handling unit - 5 WITH 27280 CFM / 6 ROWS / 80 mm static
Air handling unit - 6B WITH 10250 CFM / 6 ROWS / 80 mm static
Air handling unit - 6A WITH 12750 CFM / 6 ROWS / 80 mm static
Air handling unit - 7 WITH 23100 CFM / 6 ROWS / 80 mm static
Air handling unit - 8 WITH 28960 CFM / 6 ROWS / 80 mm static
Air handling unit - 9 WITH 29850 CFM / 6 ROWS / 80 mm static
Air handling unit - 10 WITH 31410 CFM / 6 ROWS / 80 mm static
Air handling unit - 11 WITH 28660 CFM / 6 ROWS / 80 mm static
Air handling unit - 12 WITH 26590 CFM / 6 ROWS / 80 mm static
Air handling unit - 13 WITH 16600 CFM / 6 ROWS / 80 mm static
Air handling unit - 14 WITH 24100 CFM / 6 ROWS / 80 mm static
Air handling unit - 15 WITH 26600 CFM / 6 ROWS / 80 mm static
Air handling unit - 16 WITH 4000 CFM / 6 ROWS / 65 mm static (Without Heating Coil)
Air handling unit - 17 WITH 10250 CFM / 6 ROWS / 80 mm static
DUCTING, GRILLS, DIFFUSER AND INSULATION Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.
Thickness 0.63 mm sheet
Thickness 0.80 mm sheet
Thickness 1.00 mm sheet
Thickness 1.25 mm sheet
Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.
Thickness 0.63 mm sheet
Thickness 0.80 mm sheet
Thickness 1.00 mm sheet
Thickness 1.25 mm sheet
Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc., as per specifications.
Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.
Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.
Supplying, fixing, testing & commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core.
Supplying, fixing, testing & commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core.
Jet Nozzles - Supply, installation,testing and commissioning of following Overall sizes of Jet Nozzles 375 mm dia
Supply, installation, testing & commissioning of thermal insulated flexible duct of following sizes duly supported at regular interval as per site requirement etc. complete as required as per specifications.
200 mm dia
300 mm dia
Supplying, Fixing, testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.
Fire damper
Actuator
Accoustic lining of upply air duct and plenum with 25mm resin bonded glass wool of having density of 32 kg/m3.
Supply, installation of accoustic insulation on wall and ceiling of AHU rooms with 50mm thick density 32 kg/cum resin bonded glass fibre insulation friction fixed in 610mmx610mm frame work made of 25x50x50x50x25 mm made out of of 0.6mm thick GI sheet U shaped channel and covered with reinforced fibre glass tissue and finished with 0.8mm perforated aluminum sheet etc. as required.
Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class “O”) insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.
INSULATED CHILLED WATER PIPING (Nitrile rubber insulation) Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 40 Kg / m3 density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class ‘O’ insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect; and finally applying Class 0 (BS 476) having a Flammability Index ≤ 5 (AS1530.2) Cladding of 350μm in thickness with a total weight ≥500 g/m2 made from a 3-layer composite film of metallic appearance with aluminium intermediate layer tested for UV protection as per EN ISO 4892-2 Method A and having a permanent curl to be applied with 30-50mm overlap using plastic rivets and manufacturer's recommended 50mm PSA Tapes complete as per Specifications. All bends, T-sections and end caps shall be cladded with thermoformed fittings of the same composite covering system as per approved shop drawings and specifications. Pipe supports to be used at each 1 m length shall be Insulated pipe support with self-adhesive closure, PUR/PIR load bearing Inserts, embedded in Elastomeric Nitrile Rubber insulation with two outer metal shells made of aluminum sheet. Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.
250 mm dia. (32 mm thick insulation)
200 mm dia. (32 mm thick insulation)
150 mm dia. (32 mm thick insulation)
125 mm dia. (32 mm thick insulation)
100 mm dia. (32 mm thick insulation)
80 mm dia. (32 mm thick insulation)
65 mm dia. (32 mm thick insulation)
50 mm dia. (32 mm thick insulation)
40 mm dia. (32 mm thick insulation)
32 mm dia. (19 mm thick insulation)
25 mm dia. (19 mm thick insulation)
INSULATED VALVES Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/ hot eater circulation as specified
250 mm dia
200 mm dia
150 mm dia
80 mm dia
65 mm dia
50 mm dia
40 mm dia
BALL VALVE with S.S body & internals rated for PN10 pressure
32 mm dia
25 mm dia
20 mm dia
BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified.
250 mm dia
200 mm dia
80 mm dia
65 mm dia
50 mm dia
40 mm dia
NON - RETURN VALVE with duel plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for chilled / hot water circulation including insulation as specified.
250 mm dia
200 mm dia
150 mm dia
125 mm dia
100 mm dia
80 mm dia
65 mm dia
Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified.
250 mm dia
200 mm dia
80 mm dia
65 mm dia
50 mm dia
40 mm dia
32 mm dia
25 mm dia
20 mm dia
Supplying, fixing, testing and commissioning of following sizes Motorized 2 way modulating Valve with CI Body, SS Disc, O - ring and minimum PN-16 pressure rating, conforming to BS 5155, IS 13095, with IP-55 actuator, capable of accepting upto 10V DC , and upto 20 mA electric signal and providing similar transduced feedback output to control system as required..
80 mm dia
65 mm dia
50 mm dia
40 mm dia
32 mm dia
25 mm dia
20 mm dia
Supplying, fixing, testing and commissioning of following sizes Motorized 2 way ON/OFF Valve with CI Body, SS Disc, O - ring and minimum PN-16 pressure rating, conforming to BS 5155, IS 13095, with IP-55 actuator, capable of accepting upto 10V DC , and upto 20 mA electric signal and providing similar transduced feedback output to control system as required. 250 mm dia
Supply & Installation of 1 No.1500 Lit closed expansion tank for as specified complete with: a) M.S factory fabricated tank with mounting base b) All necessary valves, flanges and associated fittings c) Drain connection d) Pressurisation Unit with pumps, power, control wiring & necessary accessories required for proper functioning of the system
Supply & Installation of 1 No. 500 Lit closed expansion tank for as specified complete with: a) M.S factory fabricated tank with mounting base b) All necessary valves, flanges and associated fittings c) Drain connection d) Pressurisation Unit with pumps, power, control wiring & necessary accessories required for proper functioning of the system
Supply & Installation testing & commissioning of a common Air separator on the return water line located at the pump suction and suitable for 1608 US GPM water flow, 250mm dia inlet, outlet. The separator should be insulated complete with high capacity air vent, service valve, non return valve, butterfly valve connection for makeup water inlet, flanges etc. as specified
Supply & Installation testing & commissioning of a common Air separator on the return water line located at the pump suction and suitable for 120 US GPM water flow, 250mm dia inlet, outlet. The separator should be insulated complete with high capacity air vent, service valve, non return valve, butterfly valve connection for makeup water inlet, flanges etc. as specified
Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required
Providing & fixing in position the mercury in glass industrial type thermometers.
Rubber Bellows for pump and chiller connections as per specifications.
250mm dia.
200mm dia
80mm dia
CONDENSER WATER PIPE Supplying, fixing, testing and commissioning of condenser water pipes of following sizes of MS ‘C’ class along with necessary clamps, vibration isolators and fittings such as bends,tees etc. but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. Note:-The Pipes size 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.
300 mm dia
200 mm dia
150 mm dia
125 mm dia
100 mm dia
VALVES WITHOUT INSULATION Supplying, fixing, testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications. BUTTERFLY VALVE (MANUAL) with CI body SS disc nitrile sheet & O - ring & PN 16 pressure rating as specified.
300 mm dia
40 mm dia
BALL VALVE with S.S body & internals rated for PN10 pressure
32 mm dia
25 mm dia
NON - RETURN VALVE with dual plate of CI body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating as specified. 300 mm dia
Supplying, fixing, testing and commissioning of following sizes Motorized Butterfly Valve with CI Body, SS Disc, O - ring and minimum PN-16 pressure rating, conforming to BS 5155, IS 13095, with IP-55 actuator, capable of accepting upto 10V DC , and upto 20 mA electric signal and providing similar transduced feedback output to control system as required. 300 mm dia
Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled water circulation as specified. 300mm dia.
Rubber Bellows for pump and chiller connections as per specifications. 300mm dia.
Supplying, fixing, testing and commissioning of Airvents
VENTILATION & EXHAUST SYSTEM - Supply, installation, testing & commissioning of VENTILATION SYSTEMS in accordance with and meeting the specifications complete with: i) Fan section, or inline centrifugal fan or SISW fan or Axial flow fan or Propeller fan as specified. ii) The pump motor shall be suitable for 415 ± 10% volts, 50 cycles, with IE3 efficiency. iii) G I Mounting frame iv) Vibration mounts/Spring suspenders v) Fire rated Canvas connection vi) Filter with necessary frame wherever necessary vii) Drive assembly and motor viii) Starter & starter power control cabling and earthing in GI cable tray
Inline Exhaust Fan for Toilets 500 cfm @ 25 mm static
Inline Exhaust Fan for Toilets 600 cfm @ 25 mm static
Inline Exhaust Fan for Toilets 1200 cfm @ 25 mm static
Exhaust Fan for Toilets 7200 cfm @ 25 mm static
Exhaust Fan for Toilets 9000 cfm @ 25 mm static
AHU Fresh air fan 10300 cfm @ 25mm static
AHU Fresh air fan 15400 cfm @ 25mm static
AHU Fresh air fan 17000 cfm @ 25mm static
Exhaust Fan for Basement smoke extraction 85000 cfm @ 20 mm static
Fresh Air Fan for Basement 85000 cfm @ 20 mm static
Exhaust Fan for Atrium smoke extraction 85000 cfm @ 20 mm static
Exhaust Fan for Pump Room 15000 cfm @ 20 mm static
Fresh Air Fan for AC plant Room 31500 cfm @ 20 mm static
Exhaust Fan for AC plant room 31500 cfm @ 20 mm static
Fresh Air Fan for Transformer Room 62600 cfm @ 20 mm static
Exhaust Fan for Transformer room 62600 cfm @ 20 mm static
Exhaust Fan for DG room 40000 cfm @ 20 mm static
SISW Exhaust Fan for Kitchen 3000 cfm @ 80 mm static
Fresh Air Fan for Utility tunnel 10500 cfm @ 20 mm static
Exhaust Fan for Utility tunnel 10500 cfm @ 20 mm static
VFD Controllers for AHU motors complete with necessary cabling, interlocks and integration with BMS
VRF Outdoor Units : Supply installation, Tesing and Commissioning of VRF system complete with indoor unit, condensing unit, Controls, Micro-processor controls, individual temp control of each indoor unit,insulated Drain pan and required accessories for smooth operation of the system.
4 HP (SIDE DISCHARGE)
INDOOR UNITS: HI STATIC DUCTABLE UNITS Supply installation, Tesing and Commissioning of indoor units complete with centrifugal blower, cooling coil with suitable rows, electronic expansion valves, air filter & insulated drain pan all as per specifications.
CENTRAL CONTROLLER AND REMOTE FOR INDOOR UNITS: Central Controller compatible for integration with IBMS
SITC of following Corded remotes for the above mentioned IDUs.
PIPING AND ACCESSORIES Supply, Installation, Testing and Commissioning of the refrigerant piping with 19 mm nitrile rubber insulation in sleeve form as specified
Supply, Installation, Testing & Commissioning of Refnet Joints, T joints of Suitable Size for the above system.
Supply, fabrication and installation of MS base frame / platform for the following VRV units complete with vibration isolation pads, brackets etc. for the above Outdoor units.
Supply, Fabrication of Cowl Piece for Outdoor Units
Supply, laying, testing and Commissioning of unarmoured 1.5 sq.mm 2 core power & communication cables between outdoor units and indoor units and Indoor to Indoor units, ODU and Intelligent Touch Controller.
IBMS Central Computer System Intel Core i5 4th Gen. Ram 4GB DDR3, HDD 500 GB, 18.5” Screen, Parallel Port & Serial Port, Wired Keyboard Mouse, Windows 8(10) Professional MS Office with Antivirus software
BMS Server
Software Web Based Graphical interface software based on MS Windows 10 / Latest. The system should be accessible from anywhere on LAN or WAN or Ethernet without additional licenses. The Communication protocol shall be one of the Industry Standard Open Protocols such as BACNet, LON etc. System should be scalable.
DDC Controller Standalone and BACnet IP Networkable 32 Bit or more , 32 MB RAM 1GHZ DDC Controllers with I/O module as per enclosed IO List. The controllers shall be capable of 3 No's of RS485 for Modbus/BACnet MSTP Integration ,standalone operation with real time clock and historical database. The DDC's shall be capable of peer to peer communication without help of system interface controller or PC. The DDCs shall be with suitable IP 67 enclosure complete with all wiring and accessories DDC-Plant Room DDC-Cooling Tower DDC-Air Handling Units & Fans with Basement - 2nos, GF- 1no, FF - 1 no., MF - 2 nos. DDC-HT< Panel DDC-DG DDC-HSD
Portable Operator Terminal Portable Operator Terminal : capable of connecting to one of the Controllers on the Communication bus and view parameters of the complete system. The Terminal should be capable of viewing / changing parameters and trend the specified parameters as per requirement
Sensors & Field Devices Supplying, installing, testing and commissioning of the following sensors / transducers / transmitters
Air Flow Switch to monitor the fan status & Filter Status
Duct Type T & RH Sensor with all mounting accessories to measure the return air temperatures in the AHUs
Duct Type Temperature Sensor with all mounting accessories to measure the return air temperatures in the CSUs
Immersion Temperature Sensor with Well
Water Flowmeter
Water Differential Pressure Switch
Water Differential Pressure Transmitter
Water Flow switch
Current Relay
Ambient Temp. RH sensor
Float Level Switch
Flame proof Level Switch
Diesel Flow Meter flameproof
Level transmitter
Flame proof Level transmitter
PH analyser
Hardness Analyser
Wiring & Conduiting Supplying, laying, termination, testing and commissioning of signal cables. (2 core 1.0 mm2), Armoured, PVC insulated, tinned copper conductor FRLS cable- unscreened. for Command/Status
Supplying, laying, termination, testing and commissioning of signal cables. (2 core 1.0 mm2), Armoured, PVC insulated, tinned copper conductor FRLS cable-screened.for Sensor/Integration/controller to controller comminication
Supplying, laying, termination, testing and commissioning of 4 Core 1.0 SQ. MM, unarmoured Armoured, PVC insulated, tinned copper conductor FRLS cable - Unscreened.for Command/Status/Sensor
Supplying, laying, termination, testing and commissioning of 6 Core 1.0 SQ. MM, unarmoured Armoured, PVC insulated, tinned copper conductor FRLS cable - Unscreened.for Command/Status/Sensor
Supplying, laying, termination, testing and commissioning of Cat 5/Cat 6 cable for bus connection- for Integration / controllers
3C X 1.5 SQ mm Armored Power cable for DDC's , Integrators
Supplying and laying PVC conduit
Supplying and layingMS conduit
STP SCADA AND INSTRUMENTATION SET
50 x 50 x 2 mm Supply and providing of GI Perforated cable tray
100mmX50mmX2mmSupply and providing of GI Perforated cable tray
Supply and providing of OFC cable with all reqired accessories like pig tail,Network Switches etc..
FIREFIGHTING Supplying and fixing M.S/ G.I 'C' Class pipes to IS: 3589 & IS 1239, screwed/ flanged/welded as specified and with heavy clamps, hangers, brackets or pipe supports all with screwed/bolted joints as required including necessary specials,fixing supports into masonry walls or RCC with anchor fasteners and painting with two finishing coats of enamel paint of approved colour over a coat of approved primer after hydraulic testing to 13.55 Kg/Sq.cm pressure, as per direction of the engineer in charge. Open Piping
250 mm dia MS Pipe as per IS 3589
200 mm dia MS Pipe as per IS 3589
150 mm dia MS Pipe as per IS 1239
100 mm dia MS Pipe as per IS 1239
80 mm dia MS Pipe as per IS 1239
65 mm dia MS Pipe as per IS 1239
50 mm dia MS Pipe as per IS 1239
40 mm dia MS Pipe as per IS 1239
32 mm dia MS Pipe as per IS 1239
25 mm dia MS Pipe as per IS 1239
Providing and fixing MS/G.I. C Class pipes (As per IS 1239 & 3589) complete with necessary fittings, with rcc anchor block support, Anti Corrosive Wrapping and coating with 4mm thick bitumasitc membrane (Pypcoat) for pipe, necessary excavation & refilling upto 1.5m length with testing of joints complete as per direction of the engineer in charge. Underground Piping
150 mm dia MS Pipe as per IS 1239
100 mm dia MS Pipe as per IS 1239
80 mm dia MS Pipe as per IS 1239
Providing and fixing C.I. sluice valves complete with bolts, nuts,rubber insertions etc. complete as per instruction of Engineering Incharge.
150 mm diameter - Class II
100 mm diameter- Class II
80 mm diameter- Class II
Providing and fixing Cast Iron Butterfly valve with SS Disc Nitrile Rubber Seal & O-Ring PN 16 pressure rating with hand lever operated including nut, bolt, flanges, gasket etc. complete as reqd.
150 mm nominal bore
100 mm nominal bore
80 mm nominal bore
Supplying and fixing flanged C.I. tested non- return valve as per IS:5213 of approved make with necessary nuts,bolts,flanges, rubber gasket etc. complete as specified.
150 mm dia . - do- as above
do- 80 mm dia . - do- as above
Providing and fixing gun metal / Bronze gate valve with C.I. wheel of approved quality (screwed end) :
40 mm nominal bore
50 mm nominal bore
65 mm nominal bore
Supplying and fixing weather proof courtyard fire hydrant M.S. hose cabinet of about 750 mm x 600 mm x 250 mm size made of MS 18G capable of accommodating two lengths of 65 mm dia.canvas hose of 15 Mtr. length with locking arrangement, and lever for opening the door after breaking glass. Each hose box to be fitted with glass door in front, painted 'FIRE' in red luminous paint. Hinges should be sturdy to bear the weight of fully open door without sagging. Cabinet should be painted two coats of red enamel paint over a primer suitable for fixing to wall /floor or Free standing including necessary M S Angles with all necessary supports etc. complete as specified.
Providing and fixing G.M singleheaded External hydrant valve as per IS-5290 including 80 mm dia x 2 mt m.s stand post as a courtyard hydrant, painting / underground protection , complete as specified
Supplying and fixing all synthetic fibre circular woven jacketted rubberlined fire hose, delivery, 38kg/cm2 burst pressure,22kg/cm2 proof pressure,14kg/cm2 working pressure, bearing IS:636-88 type A mark, in 15m length, 63mm dia., duly S.S. wire bounded with gunmetal couplings, 63mm size, pair of male & female parts, inst. type, heavy duty, bearing IS:903 mark.
Providing and Fixing GM 15 mm Air release valve, having threaded connection including the cost of 15 mm dia Brass Ball valve with required fittings as per standard design.
Supplying and fixing Fire Brigade breach inlet connection with four connecting points 63 mm size fixed over 150 mm dia MS Pipe x 2mt stand post with necessary companion flanges, nuts, bolts,gasket, washers,outlets, necessary bronze coupling connection : B215, painting / underground protectionetc. as specified.
Providing and fixing Siamese in breaching assembly in brass with twin 63 mm breaching gun metal male inlets fixed over 150mm dia MS Pipes x 2mt stand post with necessary companion flanges, nuts, bolts,gasket, washers,outlets, non-return valve, blank caps, inlet boxesconforming to BS-5041 Part 3 complete as specified.
Supplying and installing End Suction centrifugal pump as per manufacturer's pump characteristics data, cast iron casing and internal parts, make approved by Tariff Advisory Committee for fire duty, capable of discharging 2850 lpm. against 75 metre head, against all losses, complete with motor (H.P of motor to be confirmed from the pump manufacturer to suit the pump characteristics ) of approved make motor winding with class F insulation suitable for starter as per Fire Brigade / Supply Co. regulations, base plate, foundation bolts, suitable cable entry gland box, pressure gauges etc. and wired for gauges etc. and wired for automatic start on drop of pressure in the system.
Providing and installing Diesel Engine operated pump head and discharge capacity as per item FF 13 with 24 Volts DC starting motor, push button for manual starting,Tacho generator attachment for multiple kicks, electronic panel for automatic starting, fuel tank for eight hours full load run of the pump, set of 24 V required ampere- hour capacity, heavy duty lead cell, leak proof battery including interbattery connectors and terminals complete, automatic, two rate circuit battery charger suitable for either quick or trickle rate, suitable for 200/250 V 50 Hz supply, single phase, fabricated base plate for pump and engine, suitable MB type pressure switches, pressure gauges etc complete. All control units and instruments to be mounted on MCC specified under Item 15.
Supply, Installation, Testing & Commissioning double flanged vertical Air vessel fabricated from 10mm M.S. plate with dished ends from 10mm M.S. plate, outside with one coat of primer and two coats of synthetic enamel paint of approved shade, complete with approved quality and sufficient number of pressure switches, air release valve, tripod type stand, pressure gauge with ball valve, drain ball valve of 50mm dia with 2.0 meter long GI (Heavy Duty ) piping complete as required and all other required accessories to operate commonly main fire pump, and Jockey pump at drop of pressure, automatically required pressure setting; Recommended dia. : 300 mm Height of shell : 1200 mm Working pressure : 12 Kg/Sq.cm Test Pressure : 18 Kg/Sq.cm
Providing and fixing Pressure gauge (0-14 Kg/Cm2) with necessary ball / isolation valve and fittings such as tees, elbows and painting and supports etc. complete for 100mm dia
Providing and fixing Standard type Pressure switch (for operation at 0-15 Kg./sqcm) with required fittings and accessories complete
Supplying and installing Jockey Pump as per manufacturer's pump characteristics data, cast iron casing and bronze/phosphor bronze internal parts, make approved by Tariff Advisory Committee for fire duty, capable of discharging 180 lpm. against 75 metre head, against all losses, complete with TEFC motor (H.P of motor to be confirmed from the pump manufacturer to suit the pump characteristics ) of approved make motor winding with class F insulation suitable for starter as per Fire Brigade / Supply Co. regulations, base plate, necessary MS pipe reducer, vibration pads,foundation bolts, suitable cable entry gland box, pressure gauges etc. and wired for gauges etc. and wired for automatic start on drop of pressure in External Hydrant system.
Supplying, installing, testing and commissioning conventional Sprinkler quartzoid bulb type with 15mm screwed end connection of 68 deg. C. temperature rating,K 80 and orifice shall not be less than 6mm.Sprinklers shall be UL Listed / FM approved with Chrome finished.
Pendent / Up right
Side wall
Supply & fixing of approved type rosette plates ( Recessed type, in two piece) for Sprinklers below false ceiling area. The Rosette shall be fabricated by M.S. plate of 2mm thick and the finish shall be powder coated and color shall be as approved by architects / clients.
Stainless steel corrugated flexible pipe(hose) for dropping sprinklers below false ceiling, pipe shall be 16 bar pressure rating and 1500 mm long 25 mm dia with union / reducer collar, clamps etc. as required.
Supplying and fixing 150 mm installation valve with 24 V hooter; connection at pump room and fire console room complete with drain pipe leading to drain, cabling, pressure & flow switches,Bell etc.complete. (For sprinkler system)
Supplying and fixing hand held fire extinguisher ABC dry chemical powder type Fire Extinguisher of Capacity 4kg Confirms to IS 15683, bearing ISI mark complete with brass forged squeeze grip type valve fitted with pressure gauge , pressurize with dry Nitrogen gas filled, with discharge nozzle with wall mounting bracket.
Supplying and fixing hand held fire extinguisher ABC dry chemical powder type Fire Extinguisher of Capacity 9kg Confirms to IS 15683, bearing ISI mark complete with brass forged squeeze grip type valve fitted with pressure gauge , pressurize with dry Nitrogen gas filled, with discharge nozzle with wall mounting bracket.
Supplying and fixing CO2 type Fire Extinguisher of capacity 4.5 kg (6.8Liter) confirms to IS 15683, bearing ISI mark, consisting of High Pressure seamless steel cylinder (IS 7285) fitted with wheel type valve, fully charged with CO2 gas (IS 15222) & mounting brackets having fire rating 21B.
Supplying and fixing CO2 type Fire Extinguisher of capacity 9 kg (13.5Liter) confirms to IS 15683, bearing ISI mark, consisting of High Pressure seamless steel cylinder (IS 7285) fitted with wheel type valve, fully charged with CO2 gas (IS 15222) & Wheel carriage Trolley mountings.
Supplying and fixing ISI grade approved 9 Ltrs. capacity galvanised round bottomed fire buckets painted Red and lettered 'FIRE' each with a bracket to hang the bucket on a wall or pillar as directed.
Supplying safety equipments as mentioned below:- Fire man axe
Supplying and fixing swinging type wall mounted fire hose reel to IS 884 with fire hose of braided rubber to IS 444 suitably reinforced Dunlop/Fire Stone make 19 mm size and 30 Mtrs. length,with 10 mm tapering branch nozzle in Brass male and female coupling with cut off valve attachment including fixing with approved anchor fasteners and bolts complete as specified.
Construction of valve chamber of size 900 x 900 x 1500mm deep comprising of 230mm brick thick walls in cement mortar 1:5 over a bed of 150mm thick PCC 1:4:8 alround beyond the masonry faces plastered with CM 1:3 mixed with approved water proofing compound as per manufacturer's specifications, 13mm thick on internal, external, top surfaces, finished smooth with a floating coat of neat cement, providing and fixing painted Medium duty double seal RCC frame and cover, fixing the frame in RCC 1:2:4 including fabrication, formwork, curing etc., complete all as specified and directed.
Supplying and fixing specially designed gun metal orifice plate 6mm Thick for reducing the pressure upto 3.5kg/cm2 at outlet on hydrant outlets including distance pieces of suitable size for adjustment of delivery pressure complete with necessary companion flanges, nuts, bolts, gaskets etc. complete as specified.
Supplying & fixing 80 mm dia Deluge valve- A, Flanged ANSI-B 16.1,UL Listed Wet pilot Basic Trim assembly for DV-A with Test and alarm, drip & drain valve ( NTW) Including water motor gong bell- GA ,Type-A UL Listed & FM approved etc complete as directed
Solar Supply, Erection, Testing and commissioning of Solar Equipments as per the Drawings & Specifications and as directed by Engineer In Charge :
Solar PV Polycrystalline Panels, 330 Watt +3% each, 72 Cells, min. 17% efficiency, 5-Bus bar,
Solar Grid-tied Inverter, rating 25 KWp minimum, TL, AC 3-phase output power, MPPT -1 no., Efficiency >98%, RS232, Datalogger port, Datamonitoring/ controller for zero export capability using smart meter
DC Combiner box, min. 4 in/ 4 out ports with MC4 connector outlets, Fuselink, MCB, Surge protection Device
AC Combiner Box 11 AC in with 4P, 50A MCB / 1 AC out with 4P, 630A MCCB, SPD for grid-side protection, Tinned copper bus bar, R-Y-B LED indicator, Indoor IP54, MS powder coated cabinet with front glass door (as per detailed specifications)
Smart meters, 3-phase, 50 Hz, LCD display, 13 different parameter, Modbus Rtu (RS 485 ) port, Export Limitation capability, Web-based monitoring
Supply, Laying, Testing and commissioning of Cabling as per the Drawings & Specifications and as directed by Engineer In Charge :
DC Cables for PV string-Combiner box-Inverter, 4 Sq.mm., Cu, single core, multi-stranded (in mtrs.)
MC4 connectors, 4 Sq.mm. (Male/ Female pair)
AC Cable, 4C, 25 Sq.mm., Al, XPLE, insulated, Armoured cable, mtrs. (From String Inverters to ACCB)
AC Cable, 4C, 400 Sq.mm., Al, XPLE, insulated, Armoured cable, mtrs., (From ACCB to Building Sub Distribution Panel)
AC Cable, 1C, 4 Sq.mm., Cu, XPLE, insulated, flexible FRLS cable, Green color, mtrs. For solar panel earthing
Shielded Twisted Pair data cable, cat6 with metal RJ45 connectors, in mtrs.
Supply, Errection and commissioning of Mounting System as per the Drawings & Specifications and as directed by Engineer In Charge :
Solar Panel Mounting Structure for flat roof, Aluminium material profiles, interconnected, groutless mouting on roof along with SS screws, nut, bolt, anti-slip devices, PV panel mounting structs profile with spring pressure clamps, (As per detailed drawing), in KW capacity
RCC concrete blocks with J-bolt (200 x 200 x 250mm)
Supply, Erection, Testing and commissioning of Protection & Monitoring systems as per the Drawings & Specifications and as directed by Engineer In Charge :
Earthing system: Maintenance free Earth Pits & Earthing strips, separate for DC and AC system, Copper cladded rod and carbon powder as back filling will be as per IS 3043/5049
Lightning arrester system suitable for solidly earthed neutral system with all accessories like surge monitor, insulated base and bushings etc., Chemical earthing electrode
Plant CCTV system: CCTV Camera 500M Diameter/IR and cable laying with all accessories, with 48 hour backup
Weather monitoring station with sensors for Radiation, temperature, Wind velocity, humidity, web- based monitoring on cloud
INTERNAL PLUMBING Supply & Installation of water heaters complete with : i) Fixing and leveling ii) Making water connections with 15mm CP concealed stop cocks and flexible connections iii) Making approved flexible electrical connections with appropriate plug tops iv) Checking, testing and commissioning including painting of exposed metal parts etc. complete as directed by site Incharge/ Engineer.
25 Ltrs capacity a) Jaquar Elena Geyser b) CP Angle stop cock Jaquar FLR 5053N Or Cera F2002201 c) Geyser Connection 12mm dia, 450 mm length 2pc Or Any Equivalent Approved make
60 Ltrs capacity a) Jaquar Versa Geyser Or Havells SLK HB 50ltrs b) CP Angle stop cock Jaquar FLR 5053N Or Cera F2002201 c) Geyser Connection 12mm dia, 450 mm length 2pc Or Any Equivalent Approved make
Providing and fixing Modular Drinking fountain including necessary inlet/outlets, drain connection as per req. etc. complete as directed by site Incharge/ Engineer. Rated Capacity - 60 lph Oasis MMRSL Or Sunroc DF-2801 Or Any Equivalent Approved make
Providing and Fixing of Hand Dryer fixed on wooden cleats with CP brass screws and washers including drilling hole in walls with drill gun and making good the walls. Automat or equivalent approved make etc. complete as directed by site Incharge/ Engineer. Jaquar HDR-SAP-M99ACS Or PTD-SAP-DT0106CS
External Water Supply Providing, fixing and commissioning suitable complete composite Hydropneumatic system consisting of vertical multistage centrifugal pump having stainless steel (SS 304) impellers, shaft (SS-316) and housing, with single mechanical seal and pressurised tank of 100 liters capacity, complete with all standard accessories ,S S mounting bracket including pressure switch, VFD based control panel with starters, pressure gauges, isolating valves , flexible joints on suction side and isolation valve , Non - return valve & flexible joints on delivery side with nuts, bolts & washer including G I flanges, where ever required with 3 mm thick rubber insertion, with necessary protection and operational devices i.e alternate pumping operation and shut-off during dry running conditions etc. with suitable electrical motor to be operated on 210/220 OR 400/440 volt 50 cycle AC supply, suitable for following duty and with total no. of pumps - (working+standby) complete with Control Unit Panel, manifolds & chassis, as per the approval of Project-in- charge complete as directed a) Flushing/ Domestic hydropneumatic system System Capacity : 68 m3/hr Nos of pumps- 4 ( 3 working + 1stand by ) Head : 50 m
Supplying, Installing ,Testing & Commissioning of Centrifugal pumps having with S.S. Impeller, SS shaft, SS casing capable of delivering (each pump) 20 cu mt / HR LPM at 30 Mtrs.and driven by suitable H.P , 3 PH, 415V, 2900 RPM, TEFC motor, complete with anti vibration pads, etc complete with necessary starter panel & panel to pump cabaling complete as directed ( set consisting 1 working + 1 stand by pump ) ( Exg UGT excess water feed pump to Proposed UGT )
Supplying, Installing ,Testing & Commissioning of Centrifugal pumps having with S.S. Impeller, SS shaft, SS casing capable of delivering (each pump) 22.5 cu mt /HR at 50 Mtrs.and driven by suitable H.P , 3 PH, 415V, 2900 RPM, TEFC motor, complete with anti vibration pads, etc complete with necessary starter panel & panel to pump cabaling complete as directed ( set consisting 1 working + 1 stand by pump ) ( STP Treated water feed pump to Proposed UGT )
Supply, Installation & Commissioning of Water Treatment Plant of Capacity 185 KLD. System Consists :- Filter Feed Pumps 2 nos, Pressure sand filter, Activated Carbon Filter, Softner, UV Sterlizer, complete frontal piping & Valves, Control Panel with necessary etc. Product Flow - 16 m3/ hr Scope Includes :- To operate and maintain the plant and machinery for DLP + 4yrs by providing one operator in each shifts Maintaining the record of daily operations, consumptions of energy & consumables and report to Client representative. Required material Tools and Tackles & spare parts of machinery for Predictive and Breakdown maintenance. Necessary consumables during AMC. Interconnecting piping, valves, gates, fitting. Control Panel with necessary cableing.
Submersible Pump set for bore wells Three phase electric motor with suitable HPDischarge: 8 cu mt / HR at 450m Head Control Panel with necessary cabaling Includes Necessary inlet outlet valves & Fittings, bends, tees etc Pump body: Cast Iron, Impeller,Shaft SS410. Before purchasing a pump Contractor should confirm pump capacity with bore well vendor
EXTERNAL SEWAGE/STORM WATER DISPOSAL Supplying and installing approved make totally submercible sump pump for wet pits with suitable coupling, complete with mounting brackets with activating probes at high and low level etc.complete with submercible motors of 1450 RPM with vibration altern-ators vertical type and approved make all ISI certified. ( set consisting 1 w + 1 stand by pump ) Purpose- Sullage/ Muddy water pump Discharge- 6 LPS Head- 15 mtrs
Supplying and installing approved make totally submercible sump pump for wet pits with suitable coupling, complete with mounting brackets with activating probes at high and low level etc.complete with submercible motors of 1450 RPM with vibration altern-ators vertical type and approved make all ISI certified. ( set consisting 1 w + 1 stand by pump ) Purpose- Sewage pump Discharge- 6 LPS Head- 15 mtrs
Providing and Installing Bubbler Fountain equipped with 2 1/2 " GI pipe inside 50' withstand of inlet (1 Nos) with 30 Nos. GI pipe fitting outlets, 1" bubbler nozzle brass with ball joint of 1" brass valve & GI nipple 1". Including cost of submersible pimp(10 HP), LED light control panel, 12 W waterproof LED warm white light necessary Cabling
STP Designing ( aesthetically), providing, constructing and giving satisfactory trials and commissioning of sewage treatment plant of 150 cum/day average capacity and operated for 20 hours and is based on MBBR process. The design of the STP shall be based on the guidelines of CPHEEO manual on sewerage and sewage treatment. The STP shall consists of oil & grease trap, equalisation tank, inlet chamber, bar screens, grit chamber, MBBR tank, clarifier, filter feed tank, treated waste tank with compartments, sludge sump and pump, centrifuge, raw sewage pumps, pressure filter, carbon filter, softener, ozonator, laboratory equipments etc including all allied civil, mechanical, electrical and, etc. complete. Note: Additional details are provided for guidance in the design brief and layout attached. STP of 150 cum/day at Dehradun airport
ESCALATORS E3, E4 Suppply, Erection, Testing and Commissioning of following passanger elevator based with STANDARDS: EN 115, STEP WIDTH (MM): 1000 mm, HORIZONTAL STEPS: Three, VERTICAL RISE = H: 4500 MM, HORIZONTAL SPAN = L: 13853 MM, INCLINATION: 30 degree, SPEED: 0.50 M/s, GEAR BOX: WORM GEAR, MOTOR PROTECTING RATE: IP55, LIGHTING VOLTAGE: 240v, FREQUENCY: 50HZ, START : VVVF (Inverter), POWER VOLTAGE: 415v, ARRANGEMENT: SINGLE, MOTOR POWER: 7.5 KW, DEFLECTION OF TRUSS: 1/750*L, COLOR OF PAINTED TRUSS: STANDARD COLOUR, TREATMENT OF TRUSS: NORMAL PAINTING, DELIVERY IN: TWO PIECES, INSTALLATION: INDOOR, STANDARD INSTALLATION: 500 MM EXTENSION, HANDRAIL COLOR: BLACK, BALUSTRADE PANEL : TEMPERED SAFETY GLASS (10 MM), BALUSTRADE PROFILE : HAIRLINE STAINLESS STEEL, BALUSTRADE: VERTICAL, SLIMLINE - HEIGHT 1000 mm, SKIRTING: HAIRLINE STAINLESS STEEL, INNER & OUTER DECKING: HAIRLINE STAINLESS STEEL (304), STEP DEMARCATION: YELLOW PAINTING LINE, STEP: DIE CAST ALUMINIUM, GREY COLOUR, PANEL OF LANDING PLATE: ETCHED STAINLESS STEEL, COMBS: DIE CAST ALUMINUM,STOP BUTTON, KEY SWITCH, HANDRAIL ENTRANCE CONTACT, BROKEN STEP-CHAIN CONTACT, STEP SAG CONTACT, PHASE MONITOR, ZINC STEEL FLYING WHEEL COVER, STEP REVERSING FENCES, MOTOR OVERLOAD AND OVERHEAT CONTACT, COMB CONTACT, MAINTENANCE LOCKING DEVICE, ALARM BUZZER, MOTOR SPEED & ANTI-REVERSAL MONITOR, HANDRAIL ANTI-STATIC ROLLER, SERVICE BRAKE RELEASE CONTACT, STEP ANTI-STATIC BRUSH, SOFT STOP, HANDRAIL SPEED MONITOR, LANDING PLATE SWITCH: No, ALARM FOR STOP DISTANCE OVERRUN, STEP MISSING CONTACT, AUTO LUBRICATION SYSTEM, LCD FAULT DISPLAY AT CONTROLLER, EARTH LEAKAGE CIRCUIT-BREAKER, BROKEN DRIVE-CHAIN CONTACT, DRY CONTACT (UP, DN, ERROR, STOP), LED COMB LIGHTING, STEP GAP ILLUMINATION, SKIRTING LIGHTING: LED DOT LIGHTING, STEP ANTI-UPTHRUST DEVICE, HANDRAIL BROKEN CONTACT, MACHINE ROOM LIGHTING, SKIRTING BRUSH, OUTSIDE TRUSS CLADDING: HAIRLINE STAINLESS STEEL ON LEFT,RIGHT AND BOTTOM, AUTO-START: DIFFUSE SENSOR, FREE SERVICE FOR ONE YEAR. (GF to MF)
E1, E2 Suppply, Erection, Testing and Commissioning of following passanger elevator based with STANDARDS: EN 115, STEP WIDTH (MM): 1000 mm, HORIZONTAL STEPS: Three, VERTICAL RISE: 8100 MM, HORIZONTAL SPAN: 20676 MM, INCLINATION: 30 degree, SPEED: 0.50 M/s, GEAR BOX: WORM GEAR, MOTOR PROTECTING RATE: IP55, START : VVVF (Inverter), FREQUENCY: 50HZ, LIGHTING VOLTAGE: 240v, POWER VOLTAGE: 415V, ARRANGEMENT: SINGLE, MOTOR POWER: 2*11 KW, TRUSS: PAINTED TREATMENT, DELIVERY IN: FOUR PIECES, INTERMEDIATE SUPPORT: ONE, INSTALLATION: INDOOR, STANDARD INSTALLATION: 500 MM EXTENSION, HANDRAIL COLOR: BLACK, BALUSTRADE PROFILE : HAIRLINE STAINLESS STEEL,BALUSTRADE PANEL : TEMPERED SAFETY GLASS (10 MM), BALUSTRADE VERTICAL, SLIMLINE - HEIGHT 1000 mm, SKIRTING HAIRLINE STAINLESS STEEL, INNER & OUTER DECKING HAIRLINE STAINLESS STEEL, PANEL OF LANDING PLATE ETCHED STAINLESS STEEL, STEP DEMARCATION YELLOW PAINTING LINE, STEP DIE CAST ALUMINIUM, GREY COLOUR, COMBS DIE CAST ALUMINUM, STOP BUTTON , KEY SWITCH , HANDRAIL ENTRANCE CONTACT, BROKEN STEP-CHAIN CONTACT, STEP SAG CONTACT, PHASE MONITOR, ZINC STEEL FLYING WHEEL COVER, MOTOR OVERLOAD AND OVERHEAT CONTACT, COMB CONTACT, MAINTENANCE LOCKING DEVICE, ALARM BUZZER, MOTOR SPEED & ANTI-REVERSAL MONITOR, HANDRAIL ANTI-STATIC ROLLER, SERVICE BRAKE RELEASE CONTACT, SOFT STOP, HANDRAIL SPEED MONITOR, SWITCH BOARD BOX (IP54), LANDING PLATE SWITCH, ALARM FOR STOP DISTANCE OVERRUN, STEP MISSING CONTACT, AUTO LUBRICATION SYSTEM (WITH OIL COLLECTOR), LCD FAULT DISPLAY AT CONTROLLER, EARTH LEAKAGE CIRCUIT-BREAKER, FIRE INTERFACE: (24VDC/110VAC, NC DRY CONTACT AND CABLE TO BE SUPPLIED BY CLIENT), STEP ANTI-UPTHRUST DEVICE, SAFETY BRAKE ON MAIN SHAFT, SKIRTING CONTACT, STEP GAP ILLUMINATION, BROKEN DRIVE-CHAIN CONTACT, DRY CONTACT (UP, DN, ERROR, STOP), SKIRTING LIGHTING: LED DOT LIGHTING, LED COMB LIGHTING, HANDRAIL BROKEN CONTACT, EMERGENCY STOP DEVICE AT INCLINED SECTION, SKIRTING BRUSH: SINGLE ROW, LED Traffict light numbers: EACH ONE AT TOP AND BOTTOM, LED Traffict light sign: FIXED ARROW SIGN, LED TRAFFIC LIGHT: FIXED ARROW SIGN, OUTSIDE TRUSS CLADDING: HAIRLINE STAINLESS STEEL ON LEFT, RIGHT & BOTTOM, AUTO-START: DIFFUSE/RADAR SENSOR TYPE, CONTROLLER LIFT DEVICE - ONE SET, MAINTENANCE FENCE - ONE SET, INSPECTION HANDLE - ONE SET, (GF to FF)
SERVERS & WORKSTATION Database Primary Server: Supply, Installation, Testing & Commissioning of Database Primary Server for entire cameras - Complete as per specifications & preferred make.
Database Failover Server: Supply, Installation, Testing & Commissioning of Database Failover Server for entire cameras - Complete as per specifications & preferred make.
VIdeo Recording Primary Server: Supply, Installation, Testing & Commissioning of Failover Video Recording Servers. All Primary Recording servers kept at Primary Data Center. Each recording server shall support min. of 50 cameras and max. of 100 cameras. Each recording Server shall have min. 25% spare capacity to take additional cameras in future. Recording Server & storage sizing shall be done considering min. write throughput of B12 Mbps/camera - Complete as per specifications & preferred make.
Video Recording Failover Server: Supply, Installation, Testing & Commissioning of Video Recording Servers . All Failover Recording servers kept at Secondary Data Center. Each recording server shall support min. of 50 cameras and max. of 100 cameras. Each recording Server shall have min. 25% spare capacity to take additional cameras in future. Failover Recording Server & storage sizing shall be done considering min. write throughput of 3 Mbps/camera - Complete as per specifications & preferred make.
Video Analytic Primary Server: Supply, Installation, Testing & Commissioning of Video Analytic Server Each Analytic server shall support min. of 50 cameras and max. of 64 cameras. Each Analytic Server shall have min. 25% spare capacity to take additional cameras in future. All Primary Analytic servers kept at Primary Data Center - Complete as per specifications & preferred make.
Video Analytic Failover Server: Supply, Installation, Testing & Commissioning of Video Analytic Server Each Analytic server shall support min. of 50 cameras and max. of 64 cameras. Each Analytic Server shall have min. 25% spare capacity to take additional cameras in future. All Failover Analytic servers kept at Secondary Data Center - Complete as per specifications & preferred make.
SITC of WORKSTATION Supply, Installation, Testing & Commissioning of CCTV Client Operator Station with 1No. 42/46” LED Display & 1 Nos 21" LED Display- Complete as per specifications & preferred make.
Supply, Installation, Testing & Commissioning of CCTV Client Operator Station with 1 No.of 46” LED Display - Complete as per specifications & preferred make.
Supply, Installation, Testing & Commissioning of A4 size Colour Laser Printer with scan/copy feature - Complete as per specifications & preferred make.
Video Management & VA Software Supply, Installation, Testing & Commissioning of Digital Video Surveillance Server control software along with server/ NVR/NAS software loaded with necessary camera licenses for 250 cameras with 20 concurrent client user licenses (VMS shall be scalable to incorporate 2000 nos. of cameras) in N+N configuration - Complete as per specifications & preferred make.
Supply, Installation, Testing & Commissioning of Video Analytic Software licenses for 100 cameras & requirement as per specification including Object left VA -50 cameras, License plate recognition - 10 cameras and Image Tracking (attribute search) -50 cameras- Complete as per specifications & preferred make.
Network Storage Supply, Installation, Testing & Commissioning of Network attached Storage (NAS) - Complete as per specifications & preferred make. Network attached Storage (NAS) with required storage capacity (To be estimated for 500 cameras with H.264, Full resolution @ 1920 X 1080, 25 FPS, 30 days of data retention + 25% Spare; The offered storage shall be scalable to add additional 50% usable capacity at site within the same storage; No other upgrades should be required for desired scalability except for disk Arrays enclosures and Disk drives as required. )
Primary Storage (30 days)
Redundant Storage(7 days)
Supply, Installation, Testing & Commissioning of following types of Cameras -Complete as per Specifications & Preferred make.
Indoor Dome Cameras - IP Day/night Colour Mega Pixel camera
Outdoor Dome Cameras - IP Day/night Colour Mega Pixel camera
SITC of Outdoor Fixed Cameras - Box type - IP Day/night Colour Mega Pixel camera
SITC of Indoor IP PTZ Dome Cameras
SITC of Outdoor PTZ Cameras, if required at site
SITC of Multi Sensor camera - 180º panoramic overview if required at site
SITC of Speed Dome Controller Joystick, complete as per specification
Integration Integration of CCTV system with other system which includes ACS, FAS,BHS,BMS & VHT for seamless alarm based CCTV camera image pop ups
Network Server/Network Controller Supply of 19" rack mountable Digital Public Address and Emergency Sound System Controller certified to International standards of Emergency Sound System EN 54 (IEC 60849) certified and as per specifications. The cost shall include all required Fiber Network cable/termination assembly. - 1 mains + 1 Hot stand by
Proccessor for PA system IP based Digital Controller which is VDS - EN54-16 certified and complying with EN60849 standards, hot standby for controller and amplifier, Digital Audio and Control for simultaneous multi Audio channel, Prerecorded or manual announcement broadcast, Built in Supervision and monitoring for Amplifier and Microphone station, Alarm Input and Out put for interfacing with external Fire Alarm, CCTV, ( 1+1 ), Access Control or other Alarm Input, Support for multi channel Digital Audio Inputs from Call station, multi level of priority, support several type chime/tones/ emergency tones, the systems should allow PC based controlling to the network controller and programming. Universal interface module having 2x2 Audio line I/O with 8 freely programmable control contacts with monitoring provision on 8 contacts. Communicates with digital output module over proprietery protocol.The systems shall have open interface for interfacing other services sych as Fire and FID with Building Integrated service software etc. alsohaving the following features : i) Built in high and low pass filters and 8-band parametric equalisers ii) Continous inaudible monitoring of all signal paths iii) All errors must be detected, displayed, and recorded (log view) within a matter of seconds iv) The system should be able to transmit upto 20 audio channes over IP v) Timer program that can accommodate time based announcements and volume control vi) Can monitor all speaker circuits
SITC of Call Station with key pad Supply of Remote digital paging station having electret Goose-neck microphone with cordoid pickup pattern. Broadband loudspeaker for micophone monitoring and 8or better Button keypad with expansion provision of additional nos of 18 button keypads. Unbalanced auxillary audio inputs available. via standard CAT-6 cable.EN 54 Certified
Digital Power Amplifier Supply, Installation, Testing & Commissioning of EN 54 certified 19" rack mountable Digital Class-D Amplifier of 480 W minimum or equivalent power Amplifier, each with single/dual channels as per the design/Specification requirement. The amplifiers should have digital audio interface connection to network controller via Fiber optics/CAT 5 and shall have the following features as a minimum: Failover (standby) amplifier in N+1 configuration where N >= 8 at each amplifier cluster locations - complete as per specification & preferred make. Faulty amplifier shall automatically switch to standby amplifier automaticcally without any manual intervention. The cost shall include all required Fiber Network cable/termination assembly.
480 W or equivalnet Amplifier with 1 channel
480 W or equivalnet Amplifier with 2 channel ( 2 x 240W or equivalent)
Active Line array Supply of active line array with built in DSP, ADC-DAC , network interface,with software configurable vertical coverage,with ambience noise sensing microphone ,thermal overload protection ,with RJ-45,ethernet 100 Mbps interface - complete as per specifications & preferred make. The cost shall include all required mounting brackets and other installation accessories to the approval of architect. EN 54 Certified Active Line array and Active Line array (with base & Extension)
Passive - Line array Speaker Supply of 30W EN 54Certified Passive line array speaker ,with multi tap for 30/15/7.5 Wor better with the maximum SPL of 106 dB and sensitivity of 91 dB or more Frequency response shall be 190Hz - 18Khz or better. The cost shall include all required mounting brackets and other installation accessories to the approval of architect. - complete as per specifications & preferred make.
Cabinet Loudspeakers 30W Indoor/Outdoor premium cabinet / Column Loudspeaker Supply of 30W wall mount Indoor/ outdoor cabinet /Column speaker Power: 30Watts, Power Tapping:30/15/7.5 W complete as per specifications, the Frequency response shall be 190 Hz - 18KHz or better , it shall also have the maximum SPL of 106 dB and sensitivity of 91dB or better with the preferred make. The cost shall include all required mounting brackets and other installation accessories to the approval of architect. EN 54 Certified
20W Indoor/Outdoor uni-directional cabinet Speaker Supply of 20W wall mount unidirectional speaker with EN Listing for excellent speech & music reproduction.The speaker shall be IP 65 rated and should have Frequency response of 75 Hz ~ 20 KHz or better,having maximum SPL and sensitivity of 100 dB and 84 dB mounted on an angled baffle, providing a wide opening angle. -complete as per specifications & preferred make.The cost shall include all required mounting brackets and other installation accessories to the approval of architect. EN 54 Certified
20W ceiling Speaker Supply of 20W ceiling mount EN 54-24 certified speaker with suitable fire dome having the maximum SPL 98 dB or better and frequency response shall be 110- 18KHz or better with conical dispersion pattern of Dispersion angle (-6dB) @ 1Khz 170° or better - complete as per specifications & preferred make. The cost shall include all required mounting brackets and other installation accessories such as hanging arrangement/threadded rod/chain etc., to the approval of architects.
15W Horn Speaker Supply of Maximum Power of15 W with high efficiency ABS horn loudspeaker with weather protection IP65 with the maximum SPL of 112 dB and with sensitivity of 100dB - complete as per specifications & preferred make. The cost shall include all required mounting brackets and other installation accessories to the approval of architect. EN 54 Certified
Supply, Installation, Testing & Commissi+B1048576oning of 19" rack-mountable Workstation (as per specifications) based Music player capable of playback of common digital media like MP3/ MP4/WMA/ AVI/ WMV/ DivX etc., with minimum 500GB hard disk, with full function for facilities like skip/ shuffle/ repeat as per specification & approved make.
SITC of hemispeherical direction noise sensing microphone two in each public/passenger area zone - Flush/surface mounted to the approval of architects - complete as per specifications.
19"Rack mountable Digital Ambient Noise Controller, two balanced Line Inputs and Outputs, one Ambient Noise Sensor Microphone Input and one Monitor Output. Digital ambient noise control (ANC) function to automatically adjusts output gain to match changes in ambient noise levels. - Complete as per specifications.
IP based Auto Dialer with Digital voice processor to access EPABX link for Fire tender request. Auto dialer should be able to dial out minimum of 4 telephone/mobile numbers and relay digital message of Mini. 20sec.
Supply, laying & testing of 2c x 1.5 sq.mm fire survival armoured cable (600/1000V) with class-2 Copper conductor having halogen free ceramified silicon insulation and low smoke zero halogen (LSZH) inner & outer sheath. The cable Outer sheath should be in red colour with Anti-rodent & LSZH properties including end terminators, saddles, clamps with screws etc for fixing on wall/ceiling or on cable trays complete as required.
19" 42U high Amplifier Rack, 800mm depth, made of Aluminium channels with side and rear panels made of M.S. Louvered side Panels and finished to the architects requirement. The front door shall be made of toughened glass with MS Lockable door. 4 fans shall be provided at the top for Ventilation. Side Panels shall be Ventilated Type. The Rack shall be powder coated to Siemens Grey colour as per IS-5. All spare U shall be covered with blank panels.The Rack shall have all necessary trays, holes, nuts and bolts required for Mounting Amplifiers, Music Sources, Controllers, Telephone Interface Unit, Auto Dialer and any other accessories needed for the system.
Supply, Installation, Testing & Commissioning of PC Control GUI Software along with Client Workstation of Intel - Xenon E-5 Series, 8 Core or better, 8GB RAM, 500 GB HDD, DVD RW, 19" LED, Mouse, Keyboard or higher configuration with necessary software & Hardware for complete, as per specification & approved make.
Detailed design of PA System speaker layout with acoustic modeling, Testing of PA system as per specifications, Integration of Public Address System with fire alarm system with all allied and implied items required for complete functioning of the system including all interconnections, terminations accessories in the control room.
FIDS Servers, Software, Licences and Workstations, as detailed below
SITC of FIDS Servers (installed in active-active mode in each of two data centres), core software, licenses
SITC of Client Software for installation on AAI-provided PCs
SITC of FIDS Workstation PCs, with client software
SITC of 49" LED Displays with Mounting Arrangement
SITC of 32" LED Displays with Mounting Arrangement
SITC of 3x2 LED Board Displays with Mounting Arrangement
SITC of 32" LED Board
SITC of Server with accessories for Automatic Flight Announcement System (AFAS)
SITC of KVM Switch with accessories
SITC of FIDS package Software as per requirement of the tender
SITC of AFAS package Software as per requirement of the tender
Integration with AODB and other systems as required
ACAM Supply, Installation, Testing & Commissioning of Network Intelligent 4 reader Access controller, As Per technical Specification
Supply, Installation, Testing & Commissioning of Network Intelligent 2 reader Access controller, As Per technical Specification
Supply, Installation, Testing & Commissioning of REQUEST-TO-EXIT MOTION DETECTOR, As Per technical Specification
Supply, Installation, Testing & Commissioning of ELECTRIFIED LOCKING DEVICE , As Per technical Specification
Supply, Installation, Testing & Commissioning of CARD READER , As Per technical Specification
Supply, Installation, Testing & Commissioning of OUTDOOR & Indoor Biomatrix CARD READER , As Per technical Specification
Supply, Installation, Testing & Commissioning of MAGNETIC DOOR CONTACT , As Per technical Specification
Supply, Installation, Testing & Commissioning of Panic Button , As Per technical Specification
Supply, Installation, Testing & Commissioning of INTERCOM SYSTEM STATION , As Per technical Specification
Supply, Installation, Testing & Commissioning of Desktops with OS As Per technical Specification
Supply, Installation, Testing & Commissioning of Finger Print enrolment Scanner, As Per technical Specification
Supply, Installation, Testing & Commissioning of Multifunction Printers,As Per technical Specification
Supply, Installation, Testing & Commissioning of Laser Jet Network Printer, As Per technical Specification
Supply, Installation, Testing & Commissioning of AEC Smart Card personalization Printer,As Per technical Specification
Supply, Installation, Testing & Commissioning of AEC Encoder,As Per technical Specification
Supply, Installation, Testing & Commissioning of Smart cards,As Per technical Specification
SITC of Enterprise level Access Control Servers (Database & Application),As Per technical Specification
Supply, Installation, Testing & Commissioning of Enterprise level Access Control Software,As Per technical Specification
Supply, Installation, Testing & Commissioning of of ACS Client workstation,As Per technical Specification
Integration of ACS with other systems,As Per technical Specification
Supply, Installation, Testing & Commissioning of BCAS Smart cards,As Per technical Specification
Supply, Installation, Testing & Commissioning of Vehicle RFID tags,As Per technical Specification
Supply, Installation, Testing & Commissioning of RFID Registration Desktops
Supply, Installation, Testing & Commissioning of RFID Web Cam,As Per technical Specification
Development of software for Access Control & Alarm management,As Per technical Specification
Customization & Integration with BCAS of software already developed,As Per technical Specification
SITC of Health Monitoring and Asset Management tool ,As Per technical Specification
Installation Accessories,As Per Site requirment
SITC of Optical Item- Master Optical Unit Active POI SISO (850MHz+900MHz+1800MHz+2100MHz+2300MHz)
Active POI MIMO (850MHz+1800MHz+2300MHz)
Master Unit (4+4 Port) MIMO Supportable (850MHz+900MHz+1800MHz+2100MHz+2300MHz)
Remote Management System (Hardware + Software)
SITC of Optical Item- Remote Optical Unit Optical Remote Unit, 43dBm, MIMO (GSM, DCS, UMTS, LTE850, LTE1800 and LTE2300),
SITC of Optical
96 Core Armoured LSZH Optical Fiber Cable (Outdoor Type)
12 Core Armoured LSZH Optical Fiber Cable (Outdoor Type)
Single Mode Simplex Patch Cords SC-APC to SC-APC-3Mtrs.
Fiber Management System 12 Port SC-APC
LIU 6 Port SC-APC
Joint Enclosure 96F
Joint Enclosure 12F
19" 42U Transmission Rack
SITC of Antenna
Omni Antenna MIMO, 2/4 dBi, 700-2700MHz, PIM: <-130dBc
Panel Antenna MIMO, 7/9 dBi, 700-2700MHz, PIM: <-130dBc
SITC of Splitter/Coupler
2-way Splitter, N(F)
3-way Splitter, N(F)
5dB Coupler, N(F)
7dB Coupler, N(F)
10dB Coupler, N(F)
15dB Coupler, N(F)
20dB Coupler, N(F)
Terminator, 50W
SITC of Jumper-Connector
Connector, N, Straight / Male, for 1/2 Inch Regular Feeder Cable
Connector, N, Straight / Male, for 7/8 Inch General Feeder Cable
DIN-Male Connector for 1/2" Cable
1m - 1/4" Jumper Cable - N-Male - QMA Male
1m - 1/4" Jumper Cable - QMA Male - QMA Male
1m - 1/2" Jumper Cable - N-Male - N-Male
1m - 1/2" Jumper Cable - N-Male - N-Female
SITC of RF Cable
1/2-inch Regular Cable, LSZH, Fire retardant
7/8-inch General Feeder, LSZH, Fire retardant
SITC of Accessories
Z type clamp for Omni Antenna
Panel Antenna Clamp (L Type)
Weather Proofing Kit
Saddle 32mm
10 mm Trihead MS Screw (1.5 Inch)
PVC Gitti
Cable Tie Size L=300mm * 4.8 mm width
Flexible MS Pipe, 32mm
SITC of Electrical Power
1 Core 16 SQMM copper electrical cable Green LSZH
Termination lugs RING Type (AC Power cable, 16 sq.mm 1C GI)
Equipment Earthing Busbar, (EGB) Tinned Copper with 20 holes with Insulating Studs, G.I. Nut, Bolt and washers
Equipment Earthing Busbar, (EGB) Tinned Copper with 5 holes with Insulating Studs, G.I. Nut, Bolt and washers
TMRS Supply, Installation, Testing & Commissioning of OMNI Antenna 2 dBi
Supply, Installation, Testing & Commissioning of Panel Antenna, 10dBi
Radio & Controller Supply, Installation, Testing & Commissioning of Radio Terminal Equipments (portable handsets, vehicle-mount mobiles and desk-top mount fixed radios) to support Unified Communications Portable Handsets Radio 30 Nos Vehicle-Mount Mobiles Radio 10 Nos Desk-Top Mount Fixed Radios 5 Nos
Supply, Installation, Testing & Commissioning of Expansion of Digital Voice Recording system as necessary
Splitter/Coupler Supply, Installation, Testing & Commissioning of 2way splitter
Supply, Installation, Testing & Commissioning of 3way splitter
Supply, Installation, Testing & Commissioning of 4way splitter
Supply, Installation, Testing & Commissioning of Coupler 5dB
Supply, Installation, Testing & Commissioning of Coupler 7dB
Supply, Installation, Testing & Commissioning of Coupler 10dB
Supply, Installation, Testing & Commissioning of Coupler 15dB
Supply, Installation, Testing & Commissioning of Coupler 20dB
Connector Supply, Installation, Testing & Commissioning of Connector 1/2" N-Male
Supply, Installation, Testing & Commissioning of Connector 7/8" N-Male
Supply, Installation, Testing & Commissioning of Connector 1/2" DIN-Male
Supply, Installation, Testing & Commissioning of Connector 7/8" DIN-Male
Supply, Installation, Testing & Commissioning of 1m - 1/2" Jumper Cable - N-Male - N-Male
RF Cable Supply, Installation, Testing & Commissioning of 1/2-inch Regular Cable, LSZH, Fire retardant
Supply, Installation, Testing & Commissioning of 7/8-inch General Feeder, LSZH, Fire retardant
Accessories Supply & Installation of Saddle25 mm
Supply & Installation of Z clamp for Omni Antenna
Supply & Installation of Panel Antenna Clamp (L Type)
Supply & Installation of 10mm self Trihead screw 1''
Supply & Installation of Gitti
Supply & Installation of Cable Ties 10 Inch
Supply & Installation of Weather Proof Kit
Supply, Installation, Testing & Commissioning of Category 6A 4 pair UTP Cable 305m,
Supply, Installation, Testing & Commissioning of Category 6A 24 Port Loaded Patch Panel
Supply, Installation, Testing & Commissioning of Category 6A Information Outlet for Field side
Supply, Installation, Testing & Commissioning of Cat-6A Face Plate Singlex with Gl back Box
Supply, Installation, Testing & Commissioning of Cat-6A Face Plate Duplex with Gl back Box
Supply, Installation, Testing & Commissioning of Category 6A UTP Patch Cord 1 Meter
Supply, Installation, Testing & Commissioning of Category 6A UTP Patch cord 2 Meter
Supply, Installation, Testing & Commissioning of Category 6A UTP Patch Cord 3 Meter
Supplying and fixing of PVC Cable Manager finger duct type
Supply, Installation, Testing & Commissioning of Indoor single mode fiber optic cable, 12 Core
Supply, Installation, Testing & Commissioning of 48 LC Fiber Patch Panel Loaded with Splicing tray. Fibre adaptor plate with adpters
Supply, Installation, Testing & Commissioning of 288 LC Fiber Patch Panel Loaded with Splicing tray, Fiber adaptor plate with adapters
Supply, Installation, Testing & Commissioning of LC type Singlemode Fiber Pigtail
Supply, Installation, Testing & Commissioning of LC to LC Fiber Patch Cord Singlemode 3Meter
Supply, Installation, Testing & Commissioning of LC to LC Fiber Patch Cord Singlemode 5Meter
SITC of 42RU, 800w x lOOOd, 19" Comms equipment rack with front 19" rails and dual 12-outlet PDUs, and mesh-screen front and rear lockable doors, ventilated top cover with cable glands
SITC of 15RU, 800w x lOOOd, 19" Comms equipment rack with front 19" rails and dual 12-outlet PDUs, and mesh-screen front and rear lockable doors, ventilated top cover with cable glands
Supply, fabricating and fixing of 2.0 mm thick sheet steel hot dip galvanised class B perforated cable tray with horizontal & vertical bends, reducers, Tee's, cross over member and other accessories as required and duly suspended from the ceiling Gl suspenders (8 MM) including Gl bolts & Gl nuts and including painting with powder coating etc The trays should be tested to handle 150 Kgs of load at a span distance of 1.5 meters.
600 mm width x 50mm depth x 2 mm thickness.
300 mm width x 50mm depth x 1.6 mm thickness.
150 mm width x 50mm depth x 1.6 mm thickness.
Supply, assembly and laying of 150 mm width x 60mm depth x 1.6 mm thickness, complete with jointing sleeve, horizontal bends, vertical bends, level adjustment components and closer, vertical elbow, covers, access outlet, etc. complete with all other accessories under floor installation including cutting and chasing the floor/ or on surface, making good the same, placing in position and cleaning from inside complete etc. as required 300 mm wide x 38 mm deep raceway (3 compartment)
Providing and fixing 350 x 350 x 60-75 mm deep Gl (hot dip galvanized) raceways made out of 1.6 mm thick sheet steel cross over box complete as requried as per specification .
Providing and fixing 300 x 200 x 50 mm deep Gl (hot dip galvanized) raceways made out of 1.6 mm thick sheet steel vertical access box complete as requried as per specification.
Supplying and fixing of following sizes of G.l conduit 1.6mm thick along with accessories in surface / recess including painting in case of surface conduit or cutting the wall and making good the same in case of recessed conduit as required.
Supply, Installation, Testing & Commissioning of GPS Synchronized Master clock (1+1) redundant mode,As Per technical Specification - 1 Set Supply, Installation, Testing & Commissioning of 4” NTP slave clocks As Per technical Specification - 20 Nos.
Active Network-Equipment Supply, Installation, Testing & Commissioning of Core Switch,As Per technical Specification
Supply, Installation, Testing & Commissioning of Internet Router,As Per technical Specification
Supply, Installation, Testing & Commissioning of Internet Firewall/ Load balancers,As Per technical Specification
Supply, Installation, Testing & Commissioning of 24 Port Rack Switch for Server management,As Per technical Specification
Supply, Installation, Testing & Commissioning of 24 Port MPLS Switch,As Per technical Specification
Supply, Installation, Testing & Commissioning of 24 Port Access Switch PoE,As Per technical Specification
Supply, Installation, Testing & Commissioning of 48 Port Access Switch PoE,As Per technical Specification
Supply, Installation, Testing & Commissioning of A P Indoore,As Per technical Specification
Supply, Installation, Testing & Commissioning of Wireless Controller,As Per technical Specification
Supply, Installation, Testing & Commissioning of NMS,As Per technical Specification
Supply, Installation, Testing & Commissioning of AAA Solution ( in HA ),As Per technical Specification
Supply, Installation, Testing & Commissioning of Server Farm Switch,As Per technical Specification
Supply, Installation, Testing & Commissioning of Distribution Switch ,As Per technical Specification
Conference Room AV-Equipment SITC of of Conference Room IT AV System -Video conferencing with PTZ Camera-1Nos,Wireless Chairman discussion unit with pluggabke super cardiod mic and battery unit-1Nos,Wireless Delegate discussion unit with pluggabke super cardiod mic and battery unit-38Nos. Centrak control uit - 1No,Antenna Module - 1No,Wireless digital Lavalier Microphone of 1.9GHz frequency - 1No,Wireless Handheld digital microphone of 1.9GHz frequency - 2No,Digital Signal Processor - 1No,Thin Edge ceiling speaker - 8No,Digital quad core Class - D Power Amplifier - 2No,2ft X 2ft ceiling microphone tile with 29no. omni directional microphone - 2No,Wireless Microphone Charger - 2No,Dante Interface - 1No,65" 4K touch display - 1No, 4 X 4 presentation matrix - 1No, Control system - 1No,I-pad Mini - 1No,Software license - 1No,Wireelss Presentation device - 1No,Cable cubby - 4No,Complete required as per Technical specification.
Cascadable executive Room AV-Equipment SITC of of Cascadable executive Room IT AV System Video conferencing with PTZ Camera-1Nos, Wireless Chairman discussion unit with pluggabke super cardiod mic and battery unit-1Nos,Wireless Delegate discussion unit with pluggabke super cardiod mic and battery unit-20Nos,Centrak control uit - 1No,Antenna Module - 1No,Wireless digital Lavalier Microphone of 1.9GHz frequency 1No.,Wireless Handheld digital microphone of 1.9GHz frequency - 2No,Digital Signal Processor - 1No,Thin edge ceiling speaker - 6No,Digital quad core Class - D Power Amplifier - 1No,2ft X 2ft ceiling microphone tile with 29no. omni directional microphone - 2No,Wireless Microphone Charger - 2No,Dante Interface - 1No,65" 4K display - 1No,4 X 4 presentation matrix - 1No,Control system - 1No,I-pad Mini - 1No,Software license - 1No,Cable cubby - 4No. Complete required as per Technical specification.
Airport Director Room AV-Equipment SITC of of Director Room IT AV System -Video conferencing with PTZ Camera-1Nos Wireless digital Lavalier Microphone of 1.9GHz frequency - 1No,Wireless Handheld digital microphone of 1.9GHz frequency - 1No,Digital Signal Processor - 1No,2owatt edge ceiling speaker - 2No,Digital quad core Class - D Power Amplifier - 1No,2ft X 2ft ceiling microphone tile with 29no. omni directional microphone - 1No. Wireless Microphone Charger - 1No,Dante Interface - 1No,55" 4K display - 1No,4 X 4 presentation matrix - 1No,Control system - 1No,I-pad Mini - 1No,Software license - 1No,Cable cubby - 1No,Complete required as per Technical specification.
IPPBX Supply of Server based IPPBX (should support hot standby redundancy of Call Control Servers without disconnection of single call during switchover) with support upto 2000 lines with following features :- As Per technical Specification 200 IP Users ( Licenses) 20 Analog Users 1 Operator Console IP based along with PC 10 trunk port 2 PRI Trunk lines (30 Channel) Circuit with CLIP Facility One Number Scheme on all extensions Parallel ringing on GSM as well as on desk phone
Supply of 6 port Voice Mail System for Item No.1 with following features:- As Per technical Specification Voice Mail Boxes for all users PC/Server for installing Voice Mail System to be provided by bidder Unified Messaging Solution for 50 users Instruments (As per annexure A of Technical Specifications)
Supply of PC for Installing Operator Console
Supply of PC for Installing Call Billing Software
Supply of PC for Maintenance Console
Supply of Online UPS with Battery backup of 4 Hours
Main Distribution Frame with Modules for 50 users
Server/Network Rack 42 U for EPABX along with all accessories
Analog PBT CLIP Telephone Instruments as per specification
Executive IP/SIP Telephone Instruments as per specification
High End IP/SIP Telephone Instruments as per Specification
Installation, Testing, Commissioning and Training of above items
Modular Rack for Detail refer to item no. 749 in tender Volume - III
SITC of NTP Server ,As Per technical Specification
SITC of Domain Server ,As Per technical Specification
SITC of DHCP Server ,As Per technical Specification
SITC of NMS Server ,As Per technical Specification
SITC of Anti Virus Server ,As Per technical Specification
SITC of 60TB Centerlized Network Storage for Users ,As Per technical Specification
SITC of Rodent Repellent System for Data Center.As Per technical Specification.
All inclusive Comprehensive Maintenance of all Lifts & Escalators after DLP as provided under the main contract including trouble shooting, preventive maintenance and breakdown maintenance etc. as required as per good engineering practice, recommendation of the manufacturer, instructions of Engineer-in-Charge and as per terms and conditions specified (the response time in case of breakdown shall not be more than 8 hours).
First year after DLP
Second year after DLP
Third year after DLP
Fourth year after DLP
Fifth year after DLP
All inclusive Comprehensive Maintenance of all UPS after DLP as provided under the main contract including trouble shooting, preventive maintenance and breakdown maintenance etc. as required as per good engineering practice, recommendation of the manufacturer, instructions of Engineer-in-Charge and as per terms and conditions specified (the response time in case of breakdown shall not be more than 8 hours).
First year after DLP
Second year after DLP
Third year after DLP
Fourth year after DLP
Fifth year after DLP
All inclusive Comprehensive Maintenance of all HVAC after DLP (Services of Chillers, Pumps, AHU through OEM only) as provided under the main contract including trouble shooting, preventive maintenance and breakdown maintenance etc. as required as per good engineering practice, recommendation of the manufacturer, instructions of Engineer-in-Charge and as per terms and conditions specified (the response time in case of breakdown shall not be more than 8 hours).
First year after DLP
Second year after DLP
Third year after DLP
Fourth year after DLP
Fifth year after DLP
All inclusive Comprehensive Maintenance of all Fire Alram System & Aspiration System after DLP as provided under the main contract including trouble shooting, preventive maintenance and breakdown maintenance etc. as required as per good engineering practice, recommendation of the manufacturer, instructions of Engineer-in-Charge and as per terms and conditions specified (the response time in case of breakdown shall not be more than 8 hours).
First year after DLP
Second year after DLP
Third year after DLP
Fourth year after DLP
Fifth year after DLP
Manning, Operating & Maintaining the Sewage Treatment Plant complete in all respects, including all technical/non-technical manpower, consumables and disposal of treated effluent/solid sludge as per requirements, and its all comonents works as a whole and the various assets generated thereon under this contract, including cost of collection, analysis, reporting ,monitoring and maintaining record of samples from the raw sewage daily collected at least for one time a day from the entry and exit of the STP including required staff and consumables , chemicals like chlorine, polymer, salts etc., complete. as per proposed details by Vendor in approved format and training to Client representatives as per the guidelines/ requirements of the Client.
First year after DLP
Second year after DLP
Third year after DLP
Fourth year after DLP
Fifth year after DLP
All inclusive Comprehensive Maintenance of all SCCTV System after DLP as provided under the main contract including trouble shooting, preventive maintenance and breakdown maintenance etc. as required as per good engineering practice, recommendation of the manufacturer, instructions of Engineer-in-Charge and as per terms and conditions specified (the response time in case of breakdown shall not be more than 8 hours).
First year after DLP
Second year after DLP
Third year after DLP
Fourth year after DLP
Fifth year after DLP
All inclusive Comprehensive Maintenance of all PAVA System after DLP as provided under the main contract including trouble shooting, preventive maintenance and breakdown maintenance etc. as required as per good engineering practice, recommendation of the manufacturer, instructions of Engineer-in-Charge and as per terms and conditions specified (the response time in case of breakdown shall not be more than 8 hours).
First year after DLP
Second year after DLP
Third year after DLP
Fourth year after DLP
Fifth year after DLP
All inclusive Comprehensive Maintenance of all FID System after DLP as provided under the main contract including trouble shooting, preventive maintenance and breakdown maintenance etc. as required as per good engineering practice, recommendation of the manufacturer, instructions of Engineer-in-Charge and as per terms and conditions specified (the response time in case of breakdown shall not be more than 8 hours).
First year after DLP
Second year after DLP
Third year after DLP
Fourth year after DLP
Fifth year after DLP
All inclusive Comprehensive Maintenance of all Access Control Alarm Monitoriing System (ACAM) after DLP as provided under the main contract including trouble shooting, preventive maintenance and breakdown maintenance etc. as required as per good engineering practice, recommendation of the manufacturer, instructions of Engineer-in-Charge and as per terms and conditions specified (the response time in case of breakdown shall not be more than 8 hours).
First year after DLP
Second year after DLP
Third year after DLP
Fourth year after DLP
Fifth year after DLP
All inclusive Comprehensive Maintenance of all Distributed Antenna System (DAS) after DLP as provided under the main contract including trouble shooting, preventive maintenance and breakdown maintenance etc. as required as per good engineering practice, recommendation of the manufacturer, instructions of Engineer-in-Charge and as per terms and conditions specified (the response time in case of breakdown shall not be more than 8 hours).
First year after DLP
Second year after DLP
Third year after DLP
Fourth year after DLP
Fifth year after DLP
All inclusive Comprehensive Maintenance of all Trunk Mobile Radio System (TMRS) after DLP as provided under the main contract including trouble shooting, preventive maintenance and breakdown maintenance etc. as required as per good engineering practice, recommendation of the manufacturer, instructions of Engineer-in-Charge and as per terms and conditions specified (the response time in case of breakdown shall not be more than 8 hours).
First year after DLP
Second year after DLP
Third year after DLP
Fourth year after DLP
Fifth year after DLP
All inclusive Comprehensive Maintenance of all Mater Clock System (MCS) after DLP as provided under the main contract including trouble shooting, preventive maintenance and breakdown maintenance etc. as required as per good engineering practice, recommendation of the manufacturer, instructions of Engineer-in-Charge and as per terms and conditions specified (the response time in case of breakdown shall not be more than 8 hours).
First year after DLP
Second year after DLP
Third year after DLP
Fourth year after DLP
Fifth year after DLP
All inclusive Comprehensive Maintenance of all Network Active System after DLP as provided under the main contract including trouble shooting, preventive maintenance and breakdown maintenance etc. as required as per good engineering practice, recommendation of the manufacturer, instructions of Engineer-in-Charge and as per terms and conditions specified (the response time in case of breakdown shall not be more than 8 hours).
First year after DLP
Second year after DLP
Third year after DLP
Fourth year after DLP
Fifth year after DLP
All inclusive Comprehensive Maintenance of all IPPBX System after DLP as provided under the main contract including trouble shooting, preventive maintenance and breakdown maintenance etc. as required as per good engineering practice, recommendation of the manufacturer, instructions of Engineer-in-Charge and as per terms and conditions specified (the response time in case of breakdown shall not be more than 8 hours).
First year after DLP
Second year after DLP
Third year after DLP
Fourth year after DLP
Fifth year after DLP
All inclusive Comprehensive Maintenance of all Data Center after DLP as provided under the main contract including trouble shooting, preventive maintenance and breakdown maintenance etc. as required as per good engineering practice, recommendation of the manufacturer, instructions of Engineer-in-Charge and as per terms and conditions specified (the response time in case of breakdown shall not be more than 8 hours).
First year after DLP
Second year after DLP
Third year after DLP
Fourth year after DLP
Fifth year after DLP
All inclusive Comprehensive Maintenance of all Sliding Door after DLP as provided under the main contract including trouble shooting, preventive maintenance and breakdown maintenance etc. as required as per good engineering practice, recommendation of the manufacturer, instructions of Engineer-in-Charge and as per terms and conditions specified (the response time in case of breakdown shall not be more than 8 hours).
First year after DLP
Second year after DLP
Third year after DLP
Fourth year after DLP
Fifth year after DLP
Shapoorji Pallonji and Co Pvt Ltd
NCC Limited
ITD Cementation India Limited
Tata Projects Limited
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid