Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹75.4 LAccepted-AOC 14 SURI LANE KOLKATA 700 014 | KOLKATA | KOLKATA | WEST BENGAL | 700014 | L1 | Accepted-AOC AOC | |
| 2 | L2₹76.7 L+₹1.3 L (1.75%)Rejected-Finance | L2 | Rejected-Finance Rejected as L2 | |
| 3 | L3₹80.9 L+₹5.5 L (7.25%)Rejected-Finance | L3 | Rejected-Finance Rejected as L3 |
Tender Value
Refer Docs
EMD Value
₹1.4 L
Closing Date
6 Nov 2023, 1:00 pmClosed
Executive Engineer
Saktinagar Dist Hospital Campus Saktinagar Krishnagar Nadia
Electrical Installation work for Common Building of Department of CSE and DETS within the campus of Kalyani University
2023_WBPWD_595283_1
WBPWD/EE/NED/NIT/e-T/23/ (1st Call)23-24
Open Tender
ELECTRICAL WORKS ORG
Item Rate
60 days
Saktinagar Krishnagar Nadia
Please refer Tender documents.
5 documents required · 5 mandatory
₹1.4 L
Nadia Electrical Division
2 Apr 2025
17 Oct 2023
8 Nov 2023
17 Oct 2023
6 Nov 2023
17 Oct 2023
30 Oct 2023
Amount
LT Cubical Panel: SITC of CPRI approved Cubical type compartmentalised floor mounted LT panel board of suitable size and shape for existing panel room and made of 2 mm thick CRCA sheet,angle iron/flat iron for structural frame work & followed by nine tank pre-treatment of entire enclosure with powder coated finish paint having copper bus bar and following equipments & accessories. Protection required of panel is IP-54.Busbar system with EPR support for main power distribution by S&F 4 nos. of electrolyte tinned copper bar of size 50 mmx8 mm .To supply power to individual section from busbar with suitable size copper bar/wire with socketing ,all joint must be of bolted type construction.Proper colour code to be provided by PVC heat shrink sleeves.Each compartment will be providing with hylam board at back side.Installation:The complete panel board is to be installed on suitable brick padestal incl. net cement finish and as dierected by the EIC. Incoming Arrangement: 415 V, 400 A TPN SFU with HRC Fuse (Make- Legrand/Siemens/ABB/L&T Front handle)- 1 No. Bus Bar Section: 415 V, 600 A capacity 99.9% -99.5% electrolytic tinned 4 bar copper bus bar (size of flat (4x50x5mm) mounted on non- hygroscopic porcelain insulator / hylam sheet having sufficient di-electric strength duly wrapped with PVC heat Sinkable sleeve of suitable size & different colour (Red, yellow, blue & black) for phases & neutral identification - 1 Set (should be Placed Vertically Section at Panel Board).
Outgoing Arrangement: 415 V, 125 A TPN SFU with HRC Fuse (Legrand/Siemens/ABB/L&T front handle)- 6 Nos. 415 V, 63 A TPN SFU with HRC Fuse (Legrand/Siemens/ABB/L&T Front handle)- 4 Nos. Metering Panel: a) 0-500 V Digital Voltmeter- 1 No. b) 0-400 A Digital Ammeter 1 No. c) 230 V R.Y.B. LED indicator lamp - (Make- Approved) - 3 Nos.) d) 400/5 A ratio C.T. (Make- Kappa) - 3 Nos., e)Slide lock fuse - 3 Nos. f) EI Danger Board of suitable size - 1No. Interconnection: All interconnection between incoming main to busbar are to be made with suitable size electrilytic tinned copper bars and the same between busbar to each outgoing mains & for metering arrangements are to be made by suitable size of copper with proper Ring type socketing at the end of each wire leads. Installation: The complete panel board is to be installed on suitable brick padestal incl. net cement finish as directed by EIC. Painting: The complete panel board is to be spray painted after required surface treatment by 7 tanks process / sand blasting with 2 coat of red oxide primer & 2 coat of finished paint over dried or powder coating. Earthing: A separate continuous CU earth busbar of appropriate size is to be painted at the inside bottom of the panel and run across the full load of the panel board. All electrical equipment are to be properly earthed with suitable size CU wire. (NS)
S&F 415 V upto 160 A , double door VTPN DB Enclosure for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. 8 Way (Make:Legrand/Siemens/ABB) (SOR:D-11/15)
4 Way (Make:Legrand/Siemens/ABB) (SOR:D-11/15) *For AC
S&F 415V double door HTPN DB Enclosure with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. 4 Way (Make:Legrand/Siemens/ABB) (SOR: D-10/14) *For Ac
6 Way (Make:Legrand/Siemens/ABB) (SOR: D-10/14)
8 Way (MakeLegrand/Siemens/ABB) (SOR: D-10/14) *For Lab Through Sevo Stabilizer
S&F 240 V, (2+10) Way double-door SPN MCB Distribution Board (SPN) with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment of Following sizes. Enclosure (Make:Legrand/Siemens/ABB) (SOR: D-9 to D-10/13)
S&F 240/415 V, 4 way MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment (SOR: D-9/11) (Make:Legrand/Siemens/ABB)
S&F 415 V, 125 A Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection.(Make:Legrand/Siemens/ABB)(SOR: D-8/10)
S&F 240/415 V MCB Isolator on din rail of existing DBs and necessary connection.(Make:Legrand/Siemens/ABB)(SOR: D-5/6) 40 A DP MCB Type Isolator
63 A FPMCB Type Isolator
S&F 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection as follow:(Make:Legrand/Siemens/ABB) (SOR: D-6/7) 6-32 A SP MCB
63 A TP MCB
6-32 A DP MCB
S&F of 1 Module Blank Plate (Modular type for Enclosing DB Blank Place)(Approve Make) as Direction of E.I. C.(NS)
Distn. wiring in 1.1 KV grade , 3x 1.5 sq. mm (Ph.,N& E) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand:Finolex//Polycab/Havells) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Piano key type switch (Anchor make) fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 3 nos. copper bar with holes (for Ph, N & E) fixed/Sitted on bakelite/Hard Rubber insulator over the MS welded Special type Double Side chairs incl. bakelite/ Perspex top cover 3 mm thick and sheet metal (16 SWG) flushed in wall incl. mending good damages to original finish. Average Run 9 mtr.(SOR:E-9/2(a)(iv))
Average Run 8 mtr.(SOR:E-19/2(a)(iii))
-do-do-do- On Board (SOR:E-10/4(a)(i))
Distribution wiring in 1.1 KV grade, 3x 1.5 sq. mm single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand:Finolex/Polycab/Havells) partly in 20mm size PVC rigid conduit 'FR' (Brand :Precision) (for horizontal run & above false ceiling portion only) and in 19mm bore, 3mm thick polythene pipe (for vertical run embedded in wall) to light/fan/call bell points with Piano Key type switch (Anchor Make) fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish (PVC Rigid Conduit only for horizontal run & above false ceiling and vertical run concealed) Average Run 9 mtr (SOR:E-16/6(b))
Average Run 8 mtr (SOR:E-16/6(c))
S&F 240 V, 4 nos. 6A plug socket with separate 4nos. 6A Piano key type switch, indicator & 16A kit-kat flush type fuse (Make:Anchor) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board complete with three nos.suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded special type Double Side chairs incl.bakelite/Perspex/coloured Perspex (wall matching colour) top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.(NS). *For Computer Board On lab.
S&F 240 V,6A plug socket (Anchor Make), without switch & plug top on sheet metal switch board incl. S & F 100x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. (NS) *For wall Bracket Fan.
S&F CRC sheet metal (16 SWG) JB-cum- Switch Board of the sizes 175 mm x 150 mm x 65 mm complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. bakelite/Perspex/coloured Perspex (wall matching colour) top cover 3 mm thick flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works. (SOR:E-4/10(b)) *For 2nos.x6A Separate Plug.
S&F bakelite / perspex top cover on existing 175 mm x 150 mm x 65 mm Inspection board by Brass screws. (SOR:E-5/13(c)) *For 2nos.x6A Separate Plug.
S&F 240 V 6 A Piano key type switch (Anchor Make) on existing sheet metal switch board having bakelite/perspex top cover by screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.(SOR:E-5/14(a)) *For Separate Plug and Wall Bracket Fan.
S&F 240 V, 6A plug socket (Anchor Make), without switch & plug top, on existing sheet metal switch board with bakelite/perspex top cover by screws after making housing for plug by cutting bakelite/perspex top cover and making necy. connections with PVC wire and earth continuity wire etc.(SOR:E-5/15(a)) *For Separate Plug.
S&F 240 V, 6A, plug socket with separate 6 A Piano key type switch (Anchor Make) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.(SOR:E-6/21) *For 1no.x6A Separate Plug.
S&F 240 V, 3 nos. 6A & 1 no. 20A plug socket with separate 3 nos. 6A & 1 no. 20 A Piano key type switch, indicator & 16A kit-kat flush type fuse (Make:Anchor) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board complete with three nos.suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded special type Double Side chairs incl.bakelite/Perspex/coloured Perspex (wall matching colour) top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.(SOR: E-7/25). *For Computer Board.
Supply & Fixing 240 V, 1 Nos. 16/20 A Socket and 01 No. 06 A Socket With Separate 01 no. 20A Piano key type switch and 01 no. 20 A Piano key type switch (Make: Anchor) on sheet metal switch board incl. S & F 200x100x65mm MS (16SWG) switch board complete with three nos.suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded special type Double Side chairs incl. bakelite/ Perspex/ coloured Perspex (wall matching colour) top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. as to G.S. (SOR: E-3/10(a),E-5/13(b),E-5/14(a),E-5/14(b),E-5/15(a),E-5/15(b)) *For 1no.x6A + 1no.x20 ASeparate Plug.
Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Anchor Make) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. (SOR: E-6/22) *For Power Plug.
S&F 240 V, 25 A, 3 pin Modular type plug socket (Make:Legrand/Schnider/ABB), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. (SOER:E-17/5(a)) *For AC plug point.
S&F 240 V, 25 A, Modular type starter (Make:Legrand/Schnider/ABB) with 25A Modular switch type SP MCB (CCurve) (Make:Legrand/Schnider/L&T) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.(NS) *For AC Starter And MCB.
S&D 1.1KV 4Cx240 sqmm XLPE/PVC Ar Al LT cable, as per direction of EIC. (Make - Finolex/ Polycab/ Havells/Gloster) (NS )(From Source To Panel) (NS)
Laying of two cables above 185 sq. mm in an underground trench in single tier formation (horizontal), the trench size: 680 mm x 760 mm average depth, with brick protection on the top of each cable 8 (eight) Nos. bricks per Mtr. and 4 (four) Nos. bricks per Mtr. as separator between the bricks and cables and also trench to be filled up with shifted soil, leveling up and 2(b/F-2 ] For 240 Sq.mm & above cable ize.
Laying only of 1.1KV 4Cx240 sqmm XLPE/PVC Ar Al LT cable but through existing RCC/ Hume/GI Pipe/open masonary trench.(SOR:F-1/3(b))
S&D 1.1KV 4Cx70 sqmm XLPE/PVC Ar Al LT cable, as per direction of EIC. (Make - Finolex/ Polycab/ Havells/Gloster ) (From Panel To VTPN) (NS)
S&D 1.1KV 4Cx95 sqmm XLPE/PVC Ar Al LT cable, as per direction of EIC. (Make - Finolex/ Polycab/ Havells/Gloster) (From Panel To AC VTPN) (NS)
Laying only of 1.1KV 4Cx70 sqmm XLPE/PVC Ar Al LT cable but through existing RCC/ Hume/GI Pipe/open masonary trench.(SOR:F-1/3(b))
Laying only of 1.1KV 4Cx95 sqmm XLPE/PVC Ar Al LT cable but through existing RCC/ Hume/GI Pipe/open masonary trench.(SOR:F-1/3(b))
Laying of 1.1KV 4Cx70 sqmm XLPE/PVC Ar Al LT cable after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth of 100 mm and mending good the damages to original finish incl. removing the rubbish.(SOR:F-3/5(ii))
Laying of 1.1KV 4Cx95 sqmm XLPE/PVC Ar Al LT cable after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth of 100 mm and mending good the damages to original finish incl. removing the rubbish.(SOR:F-3/5(ii))
S&D 1.1KV 4Cx35 sqmm XLPE/PVC Ar Al LT cable, as per direction of EIC. (Make -Finolex/ Polycab/ Havells/Gloster) (From Panel To Lift) (NS)
S&D 1.1KV 4Cx25 sqmm XLPE/PVC Ar Al LT cable, as per direction of EIC. (Make -Finolex/ Polycab/ Havells/Gloster) (From Panel To Pump) (NS)
Laying of following XLPE/PVC Ar Al LT cable after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth of 75 mm and mending good the damages to original finish incl. removing the rubbish.(SOR:F-3/5(i)) 4Cx35 sqmm
4Cx25 sqmm
Laying of one No. 1.1KV 4Cx25 sqmm XLPE/PVC Ar Al LT cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed. (SOR: F-2/1(a))
S&D 1.1KV, 2Cx6 sq. mm XLPE/PVC Ar Al LT cable, as per direction of EIC. (Make - Finolex/ Polycab/ Havells) (For Bollard) (NS)
Laying of one No. 1.1KV, 2Cx6 sq. mm XLPE/PVC Ar Al LT cable upto 35 sq. mm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed. (SOR: F-2/1(a))
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Make:Finolex/Havellsl/Polycab) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required. 4x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as ECC (From VTPN to HTPN) (SOR:E-9/1(g1))
2x 10 sq. mm + 1x 6 sq. mm as ECC (From HTPN TO SPNDB) (SOR:E-9/1(b1))
2x 4 sq. mm + 1x 2.5 sq. mm as ECC (From HTPN to AC) (SOR:E-9/1(v))
2x 2.5 sq. mm + 1x 1.5 sq. mm as ECC (From HTPN to Computer Board) (SOR:E-9/1(s))
2x 1.5 sq. mm + 1x 1.5 sq. mm as ECC (For Separate Plug) (SOR:E-9/1(b))
2 x 10 sq. mm (SOR:E-9/1(m)) * For continuing earth Connection Wire Run as 1x 10 sq. mm As per Direction of E.I.C.
Supplying and Fixing of polythene pipe complete with fittings as necy. under ceiling/beam, bound with 22 SWG GI binding wire incl. supplying and drawing 1x18 SWG GI Wire as fish wire inside the pipes and fittings and providing 50 mm dia disc of MS sheet (20 SWG) having colour paint at one face fastened at the load point end of the polythene pipe with fish wire (synchronizing with roof/beam casting work of building construction). 19 mm dia 3 mm thick Polythene Pipe [1(b)/E-2]
25 mm dia 3 mm thick Polythene Pipe [1(c)/E-2]
Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19 mm, 3 mm thick Polythene pipe without earth continuity wire by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles. (SOR:E-3/6(a))
Cutting Channel of size (43 mm x 43 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 25 mm, 3 mm thick Polythene pipe without earth continuity wire by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles. (SOR:E-3/7(a))
Cutting Channel of size (43 mm x 125 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 40 mm, 3 mm thick Polythene pipe without earth continuity wire by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG and mending good damages to original finish by using own tools and tackles. (NS)
Making holes on RCC ceiling 125 mm depth having dia of 50 mm.(SOR:E-3/9(b))
S&F sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works. 240 mm x 200 mm x 65 mm (SOR:E-4/11(e))
175 mm x 100 mm x 65 mm (SOR:E-4/11(c))
S&F bakelite / perspex top cover on existing Inspection board by Brass screws of 240 mm x 200 mm x 65 mm (SOR:E-5/13(e))
150 mm x 100 mm x 65 mm (SOR:E-5/13(b))
S&F compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : 4Cx240 sqmm (SOR:F-4/7(c))
4Cx95 sqmm (SOR:F-4/7(c))
4Cx70 sqmm (SOR:F-4/7(c))
4Cx35 sqmm (SOR:F-4/7(c))
4Cx25 sqmm (SOR:F-4/7(c))
2Cx6 sqmm (SOR:F-4/7(a))
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : 4Cx240 sqmm (NS)
4Cx95 sqmm (NS)
4Cx70 sqmm (NS)
4Cx35 sqmm (NS)
4Cx25 sqmm (SOR:F-5/8(b))
2Cx6 sqmm (SOR:F-5/8(b))
Finishing of the PVC insulated wire ends by socketting with pin/Ring type copper sockets (Make: Dowels/Sona/Approve Make)and insulated tapes etc., including supplying sockets, tapes. 1.5 sq. mm (NS) (Make: Dowels/Sona)
2.5 sq. mm (SOR:F-5/9(i))
4 sq. mm (SOR:F-5/9(i))
6 sq. mm (SOR:F-5/9(i))
10 sq. mm (SOR:F-5/9(i))
16 sq. mm (SOR:F-5/9(i))
S&F medium gauge 65mm dia GI Pipe ( TATA/ISI-Medium) Protection with necessary fittings and jointing metarials as required.(SOR:F-6/11(e )).
Earthing with 50 mm diaTATA-Medium GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as to GS. (SOR: G-1/2 (a))
Excavation of soil for installation of Earth Electrode and filling & ramming, for Soft Soil, as per GS. (SOR:G.S G1/1(a))
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos.12 mm dia holes on the GI pipe as per GS. (SOR: G2/3(a))
S&F earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.(SOR:G-2/4 (a))
S&F earth busbar of galvanized (Hot Dip) MS flat 50 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required. (SOR:G-2/4 (c))
Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.(SOR:G-3/5 (d)) *For Panel Earth Connection
Providing CC (6:3:1) muffing 0.3 mtr x 0.3 mtr x 0.5 mtr or Eqv. Size of cylindrical structure some part below ground level and almost 0.2 mtr above ground level incl. net cement finishes incl. mending good the damages by shifting soil/rubbish.(NS) *For Bollard light
S&F IP 65 Protected Polystyrene Cable junction box with all accesiories and mechanical locking Arrangement incl making housing on the muffing with CO's Own tools and tackles. (Make: Hensel DK 1010 B) (NS)
S & F of 2 mm thick, stainless steel sheet fabricated, water proof type looping cable box (200 mm x 150 mm x 100 mm deep) comprising of one 240 V, 16 A kit-kat fuse unit, one NL on porcelain insulator, 4 nos. stud type connector, lined with rubber gasketted hinged top cover with brass machine screws etc., earthing terminal with lug on wall S&F 30 mm x 4 mm flat iron clamp, nut-bolt etc. including painting with anticorrosive paint. NS
S&F MS fan clamp of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991)(SOR:D14/29)
S & F of Box type fan clamp of 150 mm dia & 80 mm depth made of 16 SWG CRCA sheet with one end duly sealed by cover, properly welded, incl. S&F 12 mm dia 600 mm long MS rod duly bent by heat treatment at the center position of rod to grip fan bobbin properly, incl. binding the rod and fan box with reinforcement by 22 SWG steel binding wire, incl. supplying & covering the box with alkathene sheet, placed in order to prevent concrete from entering the box. (SOR:D-14/31)
S&D of 1200mm sweep 230V BLDC AC Ceiling fan incl. Blades, canopy etc. with 18" down rod (14SWG), Fork (10SWG), Heavy type insulator, 3/8th inch bolt with nut, heavy type split pin etc., as directed by EIC.(Make - Crompton 1200mm ENERGION RIVIERA 32 w w/o remote/Orient aeroquet BLDC 1200mm - / Atomberg RENESA ALPHA) (NS)
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. (SOR-C3/21(a))
S&F Socket type fan regulator (Step type) (Anchor Make) onm existing sheet metal switch board with bakelite/ perspex top cover by screw incl. making necy. connections etc.(SOR:E-6/18(b))
S&D 240 V AC, 1200 mm length box type single T-8 LED tube light fittings complete with all accessories [Make - Phillips Tmc 502 P 1xT-LED /WIPRO WIO912208 / Havells STREAK NEOT8upto 1 x22 WSSBSWH) ) (NS) *For Conventional Lighting.
S&D 240 V AC, 1200 mm length box type twin T-8 LED tube light fittings complete with all accessories [Make - Phillips Tmc 502 P 2xT-LED WIPRO WIO912208 / Havells STREAK NEOT8upto 1 x22 WSSBSWH)) (NS) *For Conventional Lighting.
S&D of 240V, 20 Watt, 1200 mm Length 2100 lm ecofriendly asthetic luminare T8-LED Tube polycarbonate Body(Make-Philips Master LED or (NS) *For Conventional Lighting.
Fixing only single / twin LED light fitting complete with all accessories Suspended from ceilling with 20 mm dia (16 SWG) EI Conduit ceiling by 2 nos. “U” type (25+50+75+50+25) mm x 30 mm x 3 mm thick MS clamp whose both side fixed on wall / ceiling by 2 nos. fastener, 2 nos. GI nipple & other side with the fitting by 2 nos. GI nipple and making connection by PVC insulated stranded copper wire (3 x 1.5 sq. mm up to 1 mt. length through the polythene pipe) with mending good damages to original finish incl. S&F the fixing materials . (NS)*For Conventional Lighting.
S&D of 230 V , 1420 RPM 30cm (12") Heavy Duty Exhaust fan with all necessary accessories, as directed by EIC (Make-EPC Electrical Pvt. Ltd.) (NS)
S&D of 230 V , 1420 RPM 23cm (9") Heavy Duty Exhaust fan with all necessary accessories, as directed by EIC (Make-EPC Electrical Pvt. Ltd.) (NS)
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of 30cm(12") diameter (SOR-C-4/28(b))
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of 30cm(12") diameter (SOR-C-4/28(a))
S&F louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) AI type For 30 cm (12") Exhaust fan as to G.S. (SOR-D-14/32(a))
S&F louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) AI type For 23 cm (9") Exhaust fan as to G.S. (SOR-D-14/32(a))
S&F 240V, 9W/10W, energy saver, environment-friendly, aesthetically designed Square shaped Integral decorative LED bollard (Make:,Havells cat: BAMBOOBL58WLED857PSYMTOPC, Wipro,Philips) with polycarbonate diffuser, IP65 protection & better optics for symmetrical light distribution, as directed by EIC.(NS)
S&D of 240 V, 36 watt recess mounted LED (2' x 2') light fittings complete with all accessories incl. hanging provision suitable for 2'x2' grid ceiling to be fixed in false ceiling by S&F GI wire from ceiling with anchor fastener or bullet, nut, bolt etc. and necy. connection by 2 x 1.5 mm² PVC insulated Cu. Wire as per direction of EIC. (Make:-Philips/Havells- PLUTOSURFACE 2 x2 PLS34WED8575/Wipro) (NS) *For False Ceilling
S&D 230V, 3W LED round recessed mounted LED spot light fittings (COB Type Colour: WW) with high efficiency diffuser provides soft glare free Asthetic light with all accessiories and making necy. Connections (Make: Philips/ Havells-UNECODJDLR8WLED830524, Wipro) (NS)
Fixing only Recess mounted LED light fitting complete with all accessories directly on False ceiling by screws etc.(SOR: C-2/14(a))
S&F of 240 V, IP66 protected 1.1 KV Surge resistant Outdoor type Flood light fitting with all accessiories and making necy. Connections and fitted with nuts, bolts, fastner etc. by CO,s own tools and tackles as per direction of EIC. (Make-Philips, Type - BVP180 LED50 CW PC WB 50W 120-270 PSU or eqv. Spec from K - Lite/Wipro/Havells). (NS)
Fixing only Floodlight fittings on top of masonary structure by 3 Nos. 10 mm dia x 87 mm long rag bolts, nuts & double washers complete either 37 mm x 10 mm MS flat support/or by other means as required.(SOR: C3/20(b))
S & D of outdoor type light fitting (Make - Philips, Type - BRP409 LED115 CW SLC FG PSU GR V2 or Similar Model of Wipro / K Lite / Havells) complete with all accessories.
Fixing only outdoor / street light LED fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 2 mts. average length having suitable bend S&F necy. length of 3×1.5 sqmm 'FR' PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc.(SOR:C-3/19))
S&F 240 V AC Buzzer (Anchor) on HW board incl. S&F HW board.(SOR: D-13/20(b))
Supply of 240 V, 18" (450 mm) dia whole metal body and metal blade wall bracket fan (Make - Crompton/EPC).
Fixing only cabin fan (Wall Bracket) on wall by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length. (SOR: D-2/29)
S&D of 240 V, 18" (450 mm) 4 (four) Blades Industrial type Air-Circulator Pedestal Fan complete with all accessories such as Regulator, Cord and 16 Amp. 3-pin Top (Make - EPC Electrical Pvt. Ltd., Heavy Duty). (NS)
S&D 240 V, Pressure Die Cast aluminium housing Conventional Bulkhead Fittings with 01 (One) No. 240 V, 9 Watt LED Bulb forMultiple Application.(Make: Bajaj Cat No.:BJDB-100 BC or, Equivalent Spec from Philips/Havells/Wipro 9W LED Bulb Make: Bajaj/Philips/Havells/Wipro) (NS).
S&D 240 V, 10 W IP-65 Pressure Die Cast aluminium housing Bulkhead fittings forMultiple Application.(Make: Philips/Havells- RUGBYGENXFTS10WLED 865 SSY MBOPC/Wipro) (NS).
S& D of 240 V, 18 W Round Surface Mounted LED Panel (Colour:CDL) with high efficiency diffuser provides soft glare free Asthetic light with all accessiories and making necy. Connections. (Make: Philips SM251C LED 205 6500 PSU WH/Havells /Wipro) (NS).
Fixing only bulk head ceiling fitting on wall /ceiling by screws etc. (SOR: C-2/13)
S&D 240 V,12 Watt Box type LED Tube (Make: Philips/ Crompton/Wipro/Havells) of PolyCarbonate Body With all acessiories. (NS) * For Mirror Light.
S&F of 240 V, IP-43 protected phosphitised powder coated steel sheet double door enclosure (eqv. size of 8 way SPNDB Enclosure (Make:ABB/Crabtree/L&T)) with locking arrangement for Timer DB comprises with following Materials- (i) 1 no. 20A/25A DP MCB ('C' Curve, 10 kA), (ii) 1 no. 24 hours programmable Time Switch (Make: with minimum switching time of 15 miniutes), (iii) 1 no. 18A/25A 2 pole contactor ), (iv) 1 no. Auto Mannual bypass Toggle Switch (Approve Make) (v)LED indication light (Approve Make) complete with all acessiories like Ph & N Bar,Din Rail etc. and making all internal wiring/Connection by suitable size PVC Sheathed Stranded 'FR' copper wire incl. shocketting the Finising end and provision for earthing attachment. *For Outdoor LED & Faced Light operation. (NS)
S&F Lightning conductor Air-terminals made of 15 mm dia 1500 mm long GI pipe (ISI Medium) having five prongs of 4 SWG GI (Hot Dip) wire at top with 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc. duly grouted on the parapet etc. in CC mortar (4:2:1), as per GS. (J-1/1)
S&F GI (Hot Dip) strips 20 mm x 3 mm thick for horizontal run on the Parapet/Roof/ Wall with GI Saddles 1100 mm apart incl. mending good the damages to building works as per GS. (SOR:J-1/9)
S&F of GI (Hot Dip) strips 20 mm x 3 mm thick for vertical run on wall with GI saddles spaced not exceeding 1000 mm apart incl. mending good damages to bldg. work as per GS.
Cutting cornices/ steps etc. including cutting recess in buildings etc. & supply & fixing 15 mm bore (ISI-Medium) GI pipe protection as below and mending good damages to the bldg. works as per GS. Length upto 0.5 Mtr
Length above 0.5 Mtr
Making soldered joints between conductors, conductors and air terminals for 4 SWG GI (Hot Dip) wire incl. supply of jointing materials and painting with 2 (two) coats of bituminous paint.
Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation, (per storey of building per vertical run)as per GS. (SOR:J-1/7)
Earthing with 50 mm diaTATA-Medium GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as to GS. (SOR: G-1/2 (a))
Excavation of soil for installation of Earth Electrode and filling & ramming, for Soft Soil, as per GS. (SOR:G.S G1/1(a))
Extra for treatment of soil by using salt & charcoal or coke for plate/pipe electrode as per GS.(SOR:G2/3(b))
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos.12 mm dia holes on the GI pipe as per GS. (SOR: G2/3(a))
GEM ENGINEERS CO-OP SOCIETY LTD
JAYBEECO
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .