Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹3.9 LAdmitted-Fee/PreQual/Technical/Finance SACHINDRA PARA WEST HARINA G P SABROOM SOUTH TRIPURA PIN 799143 | SABROOM | SOUTH TRIPURA | TRIPURA | 799143 | -41.99% | ₹3.9 L | L1 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | L2₹4.5 L+₹60,326 (15.5%)Admitted-Fee/PreQual/Technical/Finance ARALIA AGARTALA WEST TRIPURA | WEST TRIPURA | TRIPURA | 799002 | -33.00% | ₹4.5 L+₹60,326 (15.5%) | L2 | Admitted-Fee/PreQual/Technical/Finance |
| 3 | L3₹5.7 L+₹1.8 L (46.5%)Admitted-Fee/PreQual/Technical/Finance | -14.99% | ₹5.7 L+₹1.8 L (46.5%) | L3 | Admitted-Fee/PreQual/Technical/Finance |
| 4 | L4₹6.0 L+₹2.1 L (55.2%)Admitted-Fee/PreQual/Technical/Finance | -9.99% | ₹6.0 L+₹2.1 L (55.2%) | L4 | Admitted-Fee/PreQual/Technical/Finance |
| 5 | L5₹6.6 L+₹2.8 L (70.7%)Admitted-Fee/PreQual/Technical/Finance | -1.00% | ₹6.6 L+₹2.8 L (70.7%) | L5 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹6.7 L
EMD Value
₹13,421
Closing Date
14 Sept 2026, 3:00 pmClosed
The Executive Engineer, DWS Division, Sabroom
O/o the Executive Engineer, DWS Division, Sabroom
Running Mtc Of RWS Schemes/S.H Maintenance and repairing of existing SBDTW Schemes at Madhabnagar GP, Rajnagar GP, Subhashnagar GP , Krishnanagar GP, Srinagar GP, South Srinagar GP, Amlighat GP under Poangbari RD Block during the year 2026-27.
2026_CEDWS_76690_1
30/EE/DWS/DIVN/SBM/2026-27
Open Tender
Civil Works - Water Works
Percentage
270 days
Sabroom
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
₹13,421
14 Sept 2026
5 Sept 2026
14 Sept 2026
5 Sept 2026
14 Sept 2026
5 Sept 2026
5 Sept 2026 - 14 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Lifting of submersible pump with delivery assembly by heavy duty chain - pully after dismantling from delivery line and staking properly as per direction of the Engineer-in-charge. | 15 | job | 940 | ₹14,100 |
| 2 | Labour charge for fitting fixing and lowering of Submersible pump sets with delivery assembly 900 to 00 in/c re-fitting fixing with the delivery line etc as per direction of the Engineer-in-charge. | 15 | job | 850 | ₹12,750 |
| 3 | Development & washing the tube well by using Air Compressor (diesel operated) until sand free water is available as per direction of the Engineer-in-charge. | 7 | job | 3,000 | ₹21,000 |
| 4 | Providing and fitting fixing of 1500 GPH capacity submersible with 10 stage pump with suitable single phase 2 HP submerssible motor with head of 48.00 mtr DUKE make/VARUNA Make/ and other ISI mark make etc complete in all respect as per direction of the Engineer-in-charge. | 10 | job | 19,120.97 | ₹1,91,209.7 |
| 5Repair and maintenance of submessible Motor suitable for submerssible pumpset by complete dismantling in/c providing & fitting fixing of PVC ( IS : 8783-1978 ) insulated electro grade copper ( IS : 613-1984 ) conductor winding in stator & all necessary spare parts and reassembling the same including servicing of rotor & necessary trial run as per specification and direction of the Engineer-in-charge. | |||||
| 5.1 | 2.0 HP Motor suitable for 2000 GPH capacity submerssible pumpset | 3 | nos | 6,794.9 | ₹20,384.7 |
| 5.2 | 3.0 HP Motor suitable for 2000 GPH capacity submerssible pumpset | 3 | nos | 7,445.2 | ₹22,335.6 |
| 6 | Providing & fitting fixing of single phase motor starter unit (with heavy duty 2 pole contactor, relay range 18.0 - 25.0, with volt meter & amps meter) of Havels/BCH/L&T make suitable for 2 HP Submersible motor etc complete as per direction of the Engineer-in-charge. | 15 | job | 5,334.07 | ₹80,011.05 |
| 7 | Providing and fitting fixing of Moulded Case Circuit Breaker (MCCB) of Thermal release range, 415 + V, 50Hz (L & T, BCH, ABB make) as per specification and direction of the Engineer-in-charge.
i) 25-32 Amps | 8 | no | 5,299.3 | ₹42,394.4 |
| 8 | Providing and fixing C.I non-return valve of approved quality as per of CPWD specification and direction of the Engineer-in-charge.
i) 50 mm nominal bore | 5 | no | 3,626.1 | ₹18,130.5 |
stage.html
html • 0.03 MB
finance_78069.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.80 MB
Annexure-II.pdf
Additional Documents • 0.28 MB
Appendix.pdf
Additional Documents • 0.40 MB
Form-7.pdf
Additional Documents • 0.32 MB
DNIT.pdf
Tender Documents • 3.04 MB
BOQ_78069.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .