Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.1 LAccepted-AOC 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹34.0 L+₹2.2 L (6.79%)Rejected-Finance 200 NAVAGAM NAVAGAM TA SAYLA SURENDRA NAGAR GUJARAT 363430 | SURENDRANAGAR | GUJARAT | 363430 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹43.8 L+₹11.9 L (37.4%)Rejected-Finance 203 NABIL APARTMENT ASHOK NAGAR OPP HATHIKHANA ANAJ MARKET TULSIWADI ROAD KARELIBAUG VADODARA 390018 GUJARAT | VADODARA | GUJARAT | 390018 | L3 | Rejected-Finance Being L3 |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
13 Feb 2025, 6:00 pmClosed
GE (I) CG PORBANDAR
COAST GUARD DHQ NO 1, OPP BIRLA FACTORY
REPAIR MAINT OF LT UNDER GROUND CABLES STREET LIGHTS BOLLARD LIGHTS EXTERNAL WATER SUPPLY PIPE LINES AND VARIOUS TYPE OF PUMPS INSTALLED AND REPAIR AND MAINTENACE OF INTERNAL WIRING WITH FITTING AND FIXTURES FANS GEYSERS INCLUDING COMPREHENSIVE REPAI
2025_MES_693115_1
8060A/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
LEKAWADA
AS PER NIT
9 documents required · 9 mandatory
₹500
GE I CG PORBANDAR
₹76,000
Yes
29 Mar 2025
13 Jan 2025
15 Feb 2025
13 Jan 2025
13 Feb 2025
31 Jan 2025
Amount
Schedule 'A' E/M
Taking down carefully burnt out aluminium/copper point wiring (light, fan, socket or power) complete (fittings such as switches, ceiling roses, pendent, regulators, sockets, fluorescent tube light fittings etc. to be measured and paid for separately) removing materials to store for schedule of credit and making good to the disturbed surfaces of walls ceilings and floors etc., complete all as specified and directed by Engineer-in-Charge.
Disconnecting of unserviceable sub main wiring of any size and including steel conduit and accessories & removing from site and making good the disturbed surfaces including painting, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for point wiring using ISI marked 1.1 kV grade single core FR-LSH flexible sheathed cable of 1.5 Sqmm conforming to IS: 694- 1990, having multi-drawn thin strands of electrolytic copper conductor, conforming to IS: 8130- 1984 and insulation conforming to IS: 5831- 1984, for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in not less than 25mm size PVC conduit concealed/surface conforming to IS: 9537 (Part 3)- 1983, colour-coded as specified in IS: 11353- 1985, thick modular cover-plates complete in IS: 732- 1989, complete all as specified and directed by Engineer-in-Charge. Note : (i) cutting/chasing for concealed to be inclusive of quoted rate.
One light/ Bulb Holder /fan/exhaust point / bell point controlled by one, one way switch
One light point controlled by 2, Two way switch
One 3Pin/5 pin socket outlet 5/6 amps on independent board
One 3Pin/5 pin socket outlet 5/6 amps on the same board
All as per item No 3 above but 2.5 Sqmm wire for 15 amps power socket point.
Supply & Fixing in replacement of modular type 6 Amp one-way SP switch, conforming to IS: 3854-1997 with finger proof terminal, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of modular type 16 Amp one-way SP switch, conforming to IS: 3854- 1997 with finger proof terminal, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of modular type 6 Amp bell-push conforming to IS: 8884-1978 with finger proof terminal, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of modular type 2/3 pin combined shuttered type 6 Amp socket conforming to IS: 1293- 2005, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of modular type 2/3 pin combined shuttered type 6/16 Amp socket conforming to IS: 1293- 2005, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of modular type 120 Watt step fan regulator of 2 module size, conforming to IS: 11037-1984, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of 6 Amp, 250 V high quality robust surface/flush type polycarbonate/PVC ceiling rose, conforming to IS: 371- 1979, having 2/3 terminals and outside diameter not less than 63.5mm, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for point wiring using ISI marked 1.1 kV grade single core FR-LSH flexible cable of 1.5 Sqmm conforming to IS: 694-1990, having multi-drawn thin strands of electrolytic copper conductor, conforming to IS: 8130-1984 and insulation conforming to IS: 5831- 1984, for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in not less than 25mm size PVC casing capping surface conforming to IS: 9537 (Part 3)- 1983, colour-coded as specified in IS: 11353-1985, thick modular cover-plates, in IS: 732- 1989, complete all as specified and directed by Engineer-in-Charge.
One light/ Bulb Holder /fan/exhaust point / bell point controlled by one, one way switch
One light point controlled by 2, Two way switch
One 3 Pin/5 pin socket oulet 5/6 amps on independent board
One 3 Pin/5 pin socket outlet 5/6 amps on the same board
All as per item No 11 above but 2.5 Sqmm wire for 15 amps power socket point.
All as per item No 11 above but 4.0 Sqmm wire for AC power socket point.
Supply & Fixing in replacement of switch piano flush button 230 V, 6 Amps, Single pole, way ISI marked, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of Socket outlet flush type 2 in 1, 3 pin, 5 Amps 230 Volt, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of Socket outlet 3 pin, 15 Amp, flush type, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of switch piano flush button 230 V, 16 Amps, Single pole, one way ISI marked, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement modular flush metal box 6 way, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement modular white cover plate with frame 6 way, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for sub main wiring using ISI marked 1.1 kV grade single core HR- FR flexible cable, conforming to IS: 694- 1990, having multi-drawn thin strands of electrolytic copper conductors and insulation conforming to IS: 5831- 1984, type C, HR 85° C + FR for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in not less than 25mm NB UPVC medium grade surface/recessed existing conduits, conforming to IS: 9537 Part- 3, colour-coded as specified in IS: 732- 1989, including making good of disturbed surfaces of wall/ceiling/floor, and painting, complete all as specified and directed by Engineer-in-Charge. Make: RR Kabel, Polycab, Havells, Finolex (HR-FR flexible cable) & Precision, Prince, Supreme (PVC conduit) NOTE: 01 run of phase conductor, 01 run of neutral conductor, 01 run of earth continuity conductor and 01 run of concealed conduit shall be measured as one length.
2 x 4.0 Sqmm + 1 x 4.0 Sqmm earth wire
2 x 6.0 Sqmm + 1 x 6.0 Sqmm earth wire
Supply & Fixing in replacement of following DB sheet enclosure double door type single pole and neutral 240 Volt, 200A rated bus bar with fixing accessories, complete all as specified and directed by Engineer-in-Charge. of following size
SPN DB 4 way
SPN DB 8 way
TPN DB 4 way, 3 phase
Supply & Fixing in replacement 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 Amp, in the MCB DB, Complete with connection testing and commissioning, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement MCB SPN 32-40 Amp rating 240V, 10KA 'C' curve complete with connection testing and commissioning, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement MCB TPN 40-100 Amp rating 415 V, 10KA 'C' curve complete with connection testing and commissioning, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement RCBO for earth leakage, overload and short circuit protection of DP of capacity 40 Amp, 100 mA, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement RCBO for earth leakage, overload and short circuit protection of FP of capacity 40 Amp, 100 mA, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of track light, track mount LED COB luminaire with high efficacy housing made of extruded aluminium 240V, 50Hz, 20W, CCT 4000K, complete all as specified and directed by Engineer-in-Charge. Make: Wipro Cat No LD-57-251-024-40-XX/ GE/Philips or equivalent make mentioned in Appendix 'B'. Note- cost of replacing in existing cut out of false ceiling deemed to be included in unit rate.
Supply & Fixing in replacement of Sleek surface downlight LED recessed mounted luminaire ,240V, 50Hz, 18W, CCT 5700 K, round in shape, cut-out dimension 168 mm, complete all as specified and directed by Engineer-in-Charge. Make: Wipro Cat No LD06 -221-XXX-57RF* /Philips/ GE or equivalent make mentioned in Appendix 'B'.
Supply & Fixing in replacement of Sleek round recessed mounting LED downlight with AL die-cast body, finish with drop down PC diffuser to deliver low glare illumination with optimized heat sink for efficient heat dissipation 6 Watt LED compact vertical round shaped down lighter low ceiling warm white/ day cool light /Ecco light, complete all as specified and directed by Engineer-in-Charge. Make- Bajaj Cat No-BGSLO SLEEK 6W WH RD or Havells / CG / Philips or equivalent make mentioned in Appendix 'B'. Note- cost of replacing in existing cut out of false ceiling deemed to be included in unit rate
Supply & Fixing in replacement of Sleek round recessed mounting LED downlight with AL die-cast body, finish with drop down PC diffuser to deliver low glare illumination with optimized heat sink for efficient heat dissipation 18 Watt LED compact vertical round shaped down lighter low ceiling light, complete all as specified and directed by Engineer-in-Charge. Make- Bajaj Cat No-BGSLO SLEEK 18W WH RD or Havells/CG/Philips or equivalent make mentioned in Appendix 'B'. Note- cost of replacing in existing cut out of false ceiling deemed to be included in unit rate
Supply & Fixing in replacement of environmental friendly, new generation, aesthetically designed, ultra-modern recess mounting luminaire with high brightness SMD LEDs as light source, suitable for Armstrong/grid ceiling and POP mounting of cap 42 watt, size 2x2 complete including electronic driver, complete all as specified and directed by Engineer-in-Charge. Make - Havells Ordering Code PLUTONEO2X2PLR42WLED840S or PHILIPS/WIPRO or equivalent make mentioned in Appendix 'B'.
Supply & Fixing in replacement of decorative wall light, gold finish fixture with white glass diffuser suitable for 7.5 Watt LED filament lamp E27 base, complete all as specified and directed by Engineer-in-Charge. Make:- Cat part No LHFOAKD1TZ1D060 of Havells or Philips/Bajaj/Orient or equivalent make mentioned in Appendix 'B'.
Supply & Fixing in replacement of Environment friendly, energy efficient, aesthetically designed, surface ornamented with rings, moulded body, wall/ceiling light LED fixture with diffuser to give glare free light for 8 Watt, complete all as specified and directed by Engineer-in-Charge. Make-Havells Code No-LHEBKJP7OZ1W008 or Philips/HPL/Wipro/CG or equivalent make mentioned in Appendix 'B'.
Supply & Fixing in replacement of recess mounted 15 Watt LED compact edge pro range of silm fit low profile down light, complete all as specified and directed by Engineer-in-Charge. Make:- Cat part No EDGEPRORDDLR15WattLED 84OS of Havells or Philips / wipro / Syska / CG or equivalent make mentioned in Appendix 'B'.
Supply & Fixing in replacement of LED light fitting 1 x 9W / 1 x 10W bulkhead luminaires including LED light driver holder connecting up with flexible copper conductor cable of suitable size, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of swivel COB LED down light fitting 12 Watt with crysp light throw and high CRI of warm white/ day cool light including connecting up with flexible copper conductor cable of suitable size, complete all as specified and directed by Engineer-in-Charge. Make-Havells Ordering Code-LHGEEGEPGIE1W012 or Philips/HPL/Orient/SYSKA or equivalent make mentioned in Appendix 'B'.
Taking down of following items for servicing, cleaning all the dust particle & oiling, greasing the bearing and checking the electrical connection, including painting and re-fixing of ceiling fan/exhaust fan and wall mounted fan in situ, complete all as specified and directed by Engineer-in-Charge. Note: (i) Spare parts will be measured and paid separately. (ii) Rewinding/repair of fan motor will be measured and paid separately.
Ceiling Fan 1200mm sweep
Exhaust Fan 240/300mm
Exhaust Fan 450mm
Wall mounted fan 300mm
Material & Labour for cutting of burnt winding of rotor and rewinding with same gauge copper wire winding with insulated material and re-assembling and other repairing work, complete all as specified and directed by Engineer-in-Charge. Note:- Taking down and re-fixing charges will be paid under relevant items
Ceiling Fan 1200mm sweep
Exhaust Fan 240/300mm
Exhaust Fan 450mm
Wall mounted fan 300mm
Supply only spare parts of Fan/Exhaust fan & Including taking down old unserviceable parts, complete all as specified and directed by Engineer-in-Charge. of following rating
Capacitor 2.5/3.15Mfd
Ball bearing of appropriate size code
Mild steel Down Rod 600mm Long with Clamp nut bolts & split pin as par sample
Mild steel Down Rod with Clamp nut bolts& split pin for 900mm Long as par sample
Dismantling electric/water connection and taking down of storage type water heater, servicing, cleaning of inner tank etc. at site and replacement of burnout parts etc. and re-fixing in situ, complete all as specified and directed by Engineer-in-Charge. Note- worn out parts shall be measured as separately.
Supply only spare parts of Geyser, & Including taking down old unserviceable parts, complete all as specified and directed by Engineer-in-Charge. of following rating
Heating element 1.5/2 KW Tringular/circular type with rubber gasket
Thermostat as per sample/suitable to 25/50 Ltrs capacity ISI marked
body of geyser 25 Ltr capacity vertical type with indication lamps
Supply & Fixing in replacement surface mounted LED batten fitting 18/20 Watt, with driver complete all as specified and directed including connecting cable from ceiling rose to terminal block of luminaire, complete all as specified and directed by Engineer-in-Charge. Make : Philips(BN100C LED40S-6500 PSU L120 GR)/Wipro/ Osram or equivalent make mentioned in Appendix 'B'.
Supply & Fixing in replacement of wall mounted LED Tube light fitting 1 x 10W LED (6500K), 2 feet, 12W, Sleek and seamless profiled extruded aluminium batten with an efficient diffuser to illuminate work, including making connections with 2 core flexible copper wire 0.50 Sqmm from ceiling rose after fixing fitting, complete all as specified and directed by Engineer-in-Charge. Make:- Philips -Cat Part No BN 021 LED12S 6500 PSU GR or Wipro/GE Lighting or equivalent make mentioned in Appendix 'B'.
Supply & Fixing in replacement of LED post top made in cast aluminium with decorative opal polycarbonate diffuser with IP 65 protection made in cast aluminium spigot housing with decorative clear acrylic diffuser with 70W LED and inbuilt driver, complete all as specified and directed by Engineer-in-Charge. Make: Bajaj Celesta Model No. BGCL 70W LED WH or Havells/Philips/CG or equivalent make mentioned in Appendix 'B'.
Supply & Fixing in replacement of LED step light 9 watt with die-cast aluminum housing designed for rugged outdoor usage & IP 65 protection warm white, complete all as specified and directed by Engineer-in-Charge. Make:- Bajaj cat part No BLSGV 9W LED WW PRO or Philips/CG/Havells or equivalent make mentioned in Appendix 'B'.
Supply & Fixing in replacement of Cone LED Bollard light 11 Watt, new generation, energy saving, environmental friendly, long life aesthetically designed aluminium landscape luminaire for diffuser lighting with high power LED, IP 65 warm white complete with nut, bolt and PCC Foundation, complete all as specified and directed by Engineer-in-Charge. Make- Wipro Cat No LB12-131-XXX-65-5 or Bajaj/Philips//CG or equivalent make mentioned in Appendix 'B'.
Supply & Fixing in replacement of Cone NXB LED Bollard light 8 Watt, new generation, energy saving, environmental friendly, long life aesthetically designed aluminium landscape luminaire for diffuser lighting with high power LED, IP 65 warm white complete with nut, bolt and PCC Foundation, complete all as specified and directed by Engineer-in-Charge. Make- Havells, Item Description CONENXGBLS8WLEDPSYM830PSYMTOPC or Bajaj/Philips/Wipro /CG or equivalent make mentioned in Appendix 'B'.
Comprehensive maintenance and servicing of air conditioner of model DSA1021R1 ductable type comprising of hermetic/ semi hermetically scrolled compressor indoor/outdoor unit with refrigerant use R-22/ R-407 C /R 410A, of capacity 8.75 TR, making servicing of the plants and making fully in serviceable condition installed at ICGS Udhyog bhawan, complete all as specified and directed by Engineer-in-Charge. Note:- (i) The rates quoted by the tenderer includes the cost of complete comprehensive service including replacement of spares as required and visit the site at interval of 90 days to verify functioning of AC units till completion of contract as mentioned in Work Order No. 1. (ii) Rates inclusive of replacement of parts during currency of contract as and when directed by Engr-in-Charge. (iii) Servicing/ Repairs of AC units shall be carried out through the OEM only. (iv) Contractor has to submit test certificate on completion of service/ repairs of AC units issued by service provider. (v) Contractor is responsible to proper functioning of AC, leakage and seepage repaired is sole responsibility of contractor quoted rates should be including leakage and seepage repaired. (vi) this is Type 'A' AMC i.e. ALL IN ALL so that spares required will be provided by the contractor with in stipulated time period. (vii) complaints should be attended and rectified in 24 hr otherwise a penalty of Rs. 2000.00 per day will be recovered from the contractor.
Material & Labour for servicing and testing of Split type air conditioners of 1.5/2/4 ton capacity of any make inverter / non inverter complete for minimum two times during the contract period of each unit by cleaning cooling coil, condenser fins, blowing off dust from machines & air filters, checking and de-carbonizing, oiling, compressor greasing of blower motor, checking and removing any vibration, removing and cleaning the air filter pad testing after fixing at site, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for detecting the cause of leakage in any type/capacity of 1.5/2 ton inverter / non inverter AC and ensuring the complete system leak proof and charging of refrigerant gas with appropriate quantity including testing for smooth functioning, complete all as specified and directed by Engineer-in-Charge. Notes :- (i) Dismantling of unserviceable compressor, cost of refrigerant gas and re-installation of serviceable compressor after repairing are deemed to be included in the quoted rates.
Material & Labour for repair/replacement of PCB suitable for split type AC 1.5 TR type indoor unit, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for repair/replacement of PCB suitable for split type AC 2.0 TR type indoor unit, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for replacement of indoor cooling coil of split type AC 1.5 TR unit, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for replacement of indoor cooling coil of split type AC 2.0 TR unit, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for replacement of Blower motor, single phase, 230-345Volt, 50Hz 3 speed for 1.5 Ton indoor unit, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for replacement of Blower motor, single phase, 230-345Volt, 50Hz 3 speed for 2.0 Ton indoor unit, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for replacement of remote suitable for 1.5/2 Ton, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for replacement of Drain out PVC/flexible Pipe of 11/16 inch dia/17.79mm inner dia for 1.5 Ton/2 ton AC, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for replacement of swing motor 230Volt for 1.5/2 Ton AC, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for replacement of compressor of outdoor unit of split type AC 1.5 TR, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for replacement of compressor of outdoor unit of split type AC 2.0 TR, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for replacement of outdoor copper condenser unit of size 20x 30 inch size, Cu tubing size 6mm dia for outdoor Unit of split type AC 1.5 TR, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for replacement of outdoor copper condenser unit of size 20x 30 inch size, Cu tubing size 6mm dia for outdoor Unit of split type AC 2.0 TR, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for replacement of fan motor for AC 230 Volt 1180 Rpm for outdoor unit split type AC 1.5 TR, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for replacement of fan motor for AC 230 Volt 1180 Rpm for outdoor unit split type AC 2.0 TR, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for replacement of running capacitor for motor of capacity 2/4/6 mfd 230 volt suitable for 1.5/2.0 Ton AC outdoor unit, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for replacement of compressor running/starting capacitor of 45/50 mfd 230 volt suitable for 1.5/2.0 Ton AC outdoor unit, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for replacement pair of fan motor blade suitable for motor of 1.5/2 Ton AC outdoor unit, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for replacement of suction copper tubing of size 1/2'' dia with rubberised insulation and tape suitable for supply pipes for air-conditioners, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for replacement of Liquid/discharge copper tubing of size existing size 8-10mm bore including brazing etc and with rubberised insulation and tape suitable for supply pipes for air-conditioners, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for with rubberised insulation cover including adhesive tape suitable supply pipes for air-conditioners, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of outdoor unit stand of metal including fixing accessories such as nut bolt washers and fastener for 1.5/2 Ton outdoor unit, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of indoor unit bracket of metal including fixing accessories such as nut bolt washers and fastener for 1.5/2 Ton outdoor unit, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for repair/replacement of PCB suitable for Inverter type split type AC 1.5 TR type indoor unit, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for repair/replacement of PCB suitable for Inverter type split type AC 2.0 TR type indoor unit, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for replacement of Blower motor, single phase, 230V, AC for 1.5 Ton indoor unit of Inverter AC, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for replacement of Blower motor, single phase, 230V, AC for 2.0 Ton indoor unit of Inverter AC, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for replacement of indoor condenser copper coil of inverter split type AC 1.5 TR, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for replacement of indoor condenser copper coil of inverter split type AC 2.0 TR, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for replacement of outdoor condenser unit of copper with 2 run of copper pipe of outdoor unit of inverter split type AC 1.5 TR, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for replacement of outdoor condenser unit of copper with 2 run of copper pipe of outdoor unit of inverter split type AC 2.0 TR, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for replacement of compressor of outdoor unit of split type AC 1.5 TR inverter type, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for replacement of compressor of outdoor unit of split type AC 2.0 TR inverter type, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for replacement of swing motor 230 Volt for 1.5/2.0 Ton indoor unit inverter type AC, complete all as specified and directed by Engineer-in-Charge.
Taking down of split type AC 1.5 Ton Inverter type from site for replacement of outdoor unit and re-installing split type AC at site and including re-fixing of outdoor unit on wall and outdoor unit an wall mounted including bracket of MS and replacement of refrigerant tubing as per site std requirement upto 6 RM, any insulated, complete all as specified and directed by Engineer-in-Charge. Note- Gas charging if required deemed to be included in unit rate. Make Voltas/Carrier/Hitachi or equivalent make mentioned in Appendix 'B'.
Taking down of split type AC 2.0 Ton Inverter type from site for replacement of outdoor unit and re-installing split type AC at site and including re-fixing of outdoor unit on wall and outdoor unit an wall mounted including bracket of MS and replacement of refrigerant tubing as per site std requirement upto 6 RM, any insulated, complete all as specified and directed by Engineer-in-Charge. Note- Gas charging if required deemed to be included in unit rate. Make Voltas/Carrier/Hitachi or equivalent make mentioned in Appendix 'B'.
Taking down of split type AC 1.5 Ton Inverter type from site for replacement of indoor unit and re installing split type AC at site and including re-fixing of indoor unit on wall and outdoor unit an wall mounted including bracket of MS and replacement of refrigerant tubing as per site std requirement upto 6 RM, any insulated, complete all as specified and directed by Engineer-in-Charge. Note- Gas charging if required deemed to be included in unit rate. Make Voltas/Carrier/Hitachi or equivalent make mentioned in Appendix 'B'.
Taking down of split type AC 2.0 Ton Inverter type from site for replacement of indoor unit and re installing split type AC at site and including re-fixing of indoor unit on wall and outdoor unit an wall mounted including bracket of MS and replacement of refrigerant tubing as per site std requirement upto 6 RM, any insulated, complete all as specified and directed by Engineer-in-Charge. Note- Gas charging if required deemed to be included in unit rate. Make Voltas/Carrier/Hitachi or equivalent make mentioned in Appendix 'B'.
Material & Labour for taking out desert cooler of any size and capacity from existing site for repair and dismantling of all components from evaporative cooler (desert cooler) metal body very carefully i.e. exhaust fan, motor, tulu pump, PVC spare parts i.e distributor, PVC pipe, tee, bend, elbow, holding clamp and any number of nut, bolt, washer, grass paid etc, including preparation of exterior and interior portion on cooler to a smooth finish and applying one coats of bituminous paint and re-assembling the same in existing position in cooler for smooth running, complete all as specified and directed by Engineer-in-Charge. Note:- If any worn out items/ parts found during the assembling the same shall be measured and paid separately under the relevant items of schedule.
Supply & Fixing in replacement PVC connection set of three suitable for existing desert cooler, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repairs front grill suitable for existing desert cooler, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing grass pad set of three superior quality, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement motor 1.0 Ph, 50 HZ 230 V, AC max Amp 1.5, suitable for existing desert cooler, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repairs tullu pump/ water pump for desert cooler 240 V, AC 50 HZ, 10 Watt, 5 LPM, 2.0 mtr head, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repairs gas filter and NRV suitable for existing refrigerator and water cooler of cap 40-120 ltr, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of 60 watt LED street light, compact and aesthetic aluminium powder coated housing with precise street optics lense, IP66 fix on existing bracket and connection to existing electric network, complete all as specified and directed by Engineer-in-Charge. Make:- Wipro Cat No lr-13-671-XXX-57-XX or Bajaj/HPL/Philips/GE or equivalent make mentioned in Appendix 'B'.
Supply & Fixing in replacement of Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium housing, IP66, 70 Watt LED flood light, suitable for high lighting architectural facade and general purpose lighting, 50 Hz. Including IP 65 as per existing at site, complete all as specified and directed by Engineer-in-Charge. Make :- Havells Cat part No. JETAADORNFLS70WLED757SSYMTOTG or CG/Philips/HPL./Syska or equivalent make mentioned in Appendix 'B'.
Material & Labour for preparing old rusted surface of steel tubular pole by means of sand paper/scrubbing of dust etc. and apply one coat of red oxide on surface of Metallic poles and applying two coats of silver paint on Pole and numbering of poles with synthetic enamel paint white in 100mm high letters over 150x150mm blue base, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement thermoplastic cable junction box for street lights of size 205mm x 255mm x 112mm including bus bar/terminal for cable connection with IP-66 protection, complete all as specified and directed by Engineer-in-Charge. Make : Hensel Cat No.DK 2525 G / Legrand/Sintex or equivalent make mentioned in Appendix 'B'.
Supply & Fixing in replacement cable three core flexible twisted copper conductor of size 1.5 Sqmm, complete all as specified and directed by Engineer-in-Charge.
Supply & Laying in replacement of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of cross-sectional area, complete all as specified and directed by Engineer-in-Charge. for following size of cable:- Note : (i) Removing of interlocking/Paver blocks, tiles and re-fixing with the same location and making good the disturbed surface is deemed to be included in quoted rate. (ii) Fixing accessories for cable laying such as clamps and nut bolts are to be included in quoted rate.
16 Sqmm 4 Core
35 Sqmm 3.5 Core
95 Sqmm 3.5 Core
Supply and Laying in replacement of OD Double Wall Corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall for protection of underground Cable with all fittings laid in trenches / road / nallah or fixed along wall poles or laid under floor, complete all as specified and directed by Engineer-in-Charge. for the following dia:- Make: Rex/Poly/Gemini Note :-(i) Fixing accessories for pipe laying such as couplers, clamps and nut bolts are to be included in quoted rate. (ii) Excavation and earthwork shall be measured and paid separately)
50mm Outer dia
63mm Outer dia
Material & Labour for Cutting & removing existing joint and supply, jointing and testing straight through Hot shrinkable cable joint including all materials and accessories suitable for 3.5 core XLPE cable of 1100 volts’ grade, complete all as specified and directed by Engineer-in-Charge. Make: 3M/Denson/Raychem RPG Note : Excavation and Earthwork shall be measured &paid seperately.
16 Sqmm to 50 Sqmm
70 Sqmm to 150 Sqmm
Material & Labour for Site Clearance, cleaning away all grass, vegetation, saplings, Scrubs, brush wood, under growth roots…etc in soft/loose soil, complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches not exceeding 1.5 Metre wide and not exceeding 1.5 Metre in depth for laying of electric cables for fixing of poles and stay or for laying pipes (where provided for protection of cables) and getting out trimming the sides forming bottom surface to required level in soft/loose soil, complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil, complete all as specified and directed by Engineer-in-Charge.
Removal of surplus soil to a distance not exceeding 50 Metre and depositing where directed at a level not exceeding 1.5 Metre above the starting point, complete all as specified and directed by Engineer-in-Charge.
Comprehensive maintenance/ servicing and testing of RO plant including washing, cleaning of sedimentation filter, disinfection process, servicing of pressure pumping set and dosing unit complete at so as to supply qualitative water at permissible level of TDS, complete all as specified and directed by Engineer-in-Charge. Note:- (a) Spares required for replacement will measured and paid separately under respective items here-in-this schedule. (b) The rate quoted by the tenderer includes cost of maint/ servicing of above said plant once in a period of 90 days till the date of completion of work. (c) Servicing should be done by OEM/ authorized agency and not by any local mechanic. (d) Contractor shall be produce all purchase voucher and test certificate before submitted RAR. Note:- (i) Servicing should be done by OEM/ authorized agency and not by any local mechanics. (ii) Spare parts required will be measured and paid separately in relevant items of this schedule (iii) Replacement of sedimentation filter in each visit is deemed to be included in the unit rate.
Supply & Fixing in replacement RO membrane as existing for 50/60 Ltrs RO plant, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement RO membrane Housing as existing 50/60 ltrs RO plant, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement carbon filter for 50/60 LPH Ltrs RO plant, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement spun/cartridge filter for 50/60 Ltrs RO plant, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement 1/2 Pipe for 50/60 Ltrs RO plant, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement booster pump 48 VDC/raw water pump/dosing pump suitable for 50/ 60 Ltrs RO plant, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of water controller sensor/control panel for 50/60 Ltrs RO plant, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement solenoid valve for 50/60 Ltrs RO plant, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in anti scalent chemical, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement low/ high pressure AC/DC switch of 50/60 Ltrs RO plant, complete all as specified and directed by Engineer-in-Charge.
Dismantling, cleaning and overhauling of 0.25/0.5 HP centrifugal mono block pump set/ pressure booster pump set of the following capacities including rewinding of motor with appropriate super enamelled copper wire of existing gauge, replacement of bearing - 02 Nos, including all connection and testing complete for following unserviceable replacement of parts:- (i) Replacement of bush (gland). (ii) Replacement of pump shaft. (iii) Replacement of impeller. (iv) Replacement of shaft sleeve. Note: Except winding material, all unserviceable components of Pump-Motor will be replaced by the contractor and are inclusive rate in job)
Dismantling, cleaning and overhauling of 01 HP submersible pump set of the following capacities including rewinding of motor with appropriate super enamelled copper wire of existing gauge, replacement of bearing - 02 Nos, including all connection and testing complete for following unserviceable replacement of parts:- (i) Replacement of bush (gland). (ii) Replacement of pump shaft. (iii) Replacement of impeller. (iv) Replacement of shaft sleeve. Note: Except winding material, all unserviceable components of Pump-Motor will be replaced by the contractor and are inclusive rate in job)
Removal of lowering & lowering pump Motor, Dismantling, cleaning and overhauling of 25 HP bore well submersible pump set of the following capacities including rewinding of motor with appropriate super enamelled copper wire of existing gauge, replacement of bearing - 02 Nos, including all connection and testing complete for following unserviceable replacement of parts:- (i) Replacement of bush (gland) and clamps of bore well. (ii) Replacement of pump shaft and bore well cover. (iii) Replacement of impeller. (iv) Replacement of shaft sleeve. Note: Except winding material, all unserviceable components of Pump-Motor will be replaced by the contractor and are inclusive rate in job)
Material and labour for copper rewinding of damaged/burnt motor/submersible of capacity 0.25HP to 1 HP any type by using enamelled copper wire of superior quality of existing grade and same Nos. of turns including varnishing ‘F’ class insulation and drying in heat chamber / oven or through insulated winding copper wire including all other material / fittings and testing on completion, complete all as specified and directed by Engineer-in-Charge.
Taking up or down steel tubing and connections, including cleaning for refixing or removal to store of following sizes
25mm bore
40mm bore
Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified as per site requirement complete of sizes of nominal dia:-
Supply & Fixing in replacement of CPVC Gate /ball valves as per requirement of the site of the following
Supply & Fixing in replacement of Stop valves, cast copper alloy, 25mm inner dia, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of Stop valves, cast copper alloy, 50mm inner dia, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, complete all as specified and directed by Engineer-in-Charge.
Servicing of DG set ('C' Check) of Cap 25 KVA by Rep of authorised service centre as per manufacturer manual and checking of fuel supply system, Lubrication system, cooling system, battery ignition system and rectification of defect if any and including replacement of following, complete all as specified (a) Lub oil filter. (b) Lubrication oil. (c) Fuel filter. (d) Coolant top up. Make of DG set: TATA Power lux
Supply only following parts/ Items & Including taking down old unserviceable parts. for DG set 25 KVA:-
Engine oil 20W40
Coolant
Radiator servicing complete
controller panel of DG set
Water Pump Assembly
HWT Switch
AVR of DG for 20/25 KVA capacity including with connection, complete all as specified and as directed
Fuel Return/Supply Pipe
Pipe EGR & EGR valve
V Belt
VDO Oil Pressure sensor cum Switch 0-7 BA
Hose pipe set
ARTI CONSTRUCTION (BID ID -3230540)
FAIZA ENTERPRISE (BID ID -3232931)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .