Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.8 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹36.5 L+₹2.7 L (7.98%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹37.7 L+₹3.9 L (11.5%)Rejected-Finance | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹40.4 L+₹6.5 L (19.3%)Rejected-Finance D NO 29 2 43 SING HOTEL JUNCTION CMR ROAD VISAKHAPATNAM 530 020 | VISAKHAPATANAM | ANDHRA PRADESH | 530020 | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹40.9 L+₹7.1 L (20.8%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | BAPATLA | ANDHRA PRADESH | 504214 | L5 | Rejected-Finance Not Being L1 |
Tender Value
Refer Docs
EMD Value
₹1.3 L
Closing Date
27 Mar 2021, 6:00 pmClosed
GE I DM
NAVAL DOCKYARD VISAKHAPATNAM 530014
REPAIR / MAINTENANCE AND REPLACEMENT OF HIGH MAST LIGHTS, UNDERGROUND CABLE, EARTHING AND ALLIED MISC E/M MAINTENANCE WORK AT VARIOUS LOCATION / SUB STATION OF NAVAL DOCKYARD UNDER GE (I) DM, VISAKHAPATNAM
2021_MES_419221_2
SSGE/8529/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
NAVAL DOCKYARD VISAKHAPATNAM
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹1,000
GE I DM
₹1.3 L
Yes
27 Apr 2021
10 Mar 2021
1 Apr 2021
10 Mar 2021
27 Mar 2021
15 Mar 2021
Amount
M & L for Earthing complete with galvanised steel pipe electrode, 40mm bore, heavy grade, 2.5 mtr long buried directly and vertically in ground with top edge at ground level after making bore hole of size not less than 300 mm dia and 2.65 Mtr long using suitable mechanical drilling rig or mannually (for drilling near the specified location), connected with galvanised steel earthing strip 32 x 6mm all as shown in Plate No-2, connected to the earthing test point, concrete pit in PCC 1:3:6 type C-2 with RCC precast pit cover slab 400mm x 400 mm x 80mm with handle for lifting made out of 8mm dia MS rod, funnel, wiremesh, charcoal and salt in alternate 150mm thick layers around GI earth pipe, including necessary returning filling in & removal all as specified or indicated in SSR Part-I, including testing to achieve earth resistance value as per IS specification on completion complete all as specified and as directed.
M&L for fixing Copper earth strip of size 75mm x 10 mm making drilled hole at both ends and fixing to transformer earth point / earth test point including dismantling taking down old rusted steel earth strip complete all as specified and as directed.
M&L for fixing galvanised earth strip of size 32mm x 6 mm making drilled hole at both ends and fixing to electrical structure/equipment earth point / earth test point including dismantling taking down old rusted steel earth strip complete all as specified and as directed.
M&L for RCC concrete cement cable trench cover of size 1200mm X 600mm X 75mm using 1:2:4 20 mm graded aggregate and 10 mm dia bar set in cement complete all as specified and as directed.
Material and labour for removal of broken earthing cement / concrete pit and reconstruction using type C1 - 1:3:6 ( 20 mm graded aggregate) including precast RCC pit cover square/round of size 400 mm X 400 X 80 mm complete all as specified and directed
Matereal and labour for replacement of broken pit cover square/round shape as per existing complete all as specified and as directed.
Supply and fix aluminium bas bar and taking old one complete all as specified and as directed.
Dismantling taking out LT/HT cable from panel/transformer/floor of sub station for repair or for realingnment of cable and refixing the cables with proper staking with proper alingnment of cable and refixing the cables with proper on duct and making feeder wise bundle of cable using PVC cable tie for sizes of cable 3.00 core 95 sqmm to 185 sqmm 11000 volt grade complete all as specified and as directed.
All as per item No.8.00 above but for cable sizes 240 sqmm
All as per item No.8.00 above but for cable sizes 300 sqmm
All as per item No. 8.00 above but for cable sizes 400 sqmm
Supply and fix rubber insulating mat in front of LT panel board of size 2.0 mm thick, 1.0 Mtr width to 3.3 KV complete all as specified and directed
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth and getting out in soft loose soil complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed.
Removing of excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
Supply and fixing HDPE double wall pipe corugated pipe of size 40 mm dia for cable protection laid in trenches in lieu of sand/brick protection complete all as specified and directed.
Supply and laying in trenches XLPE insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 Volts grade cross section area 6 Sqmm 2 core and connection complete with aluminium cable lugs including dismantling taking down unserviceable one complete all as specified and directed.
All as per ser No.17.00 above but of size 10 sqmm, 4 core
All as per ser No.17.00 above but of Size 16 Sqmm 4 core
All as per ser No. 17.00 above but of Size 25 Sqmm 3.5 core
All as per ser No.17.00 above but of Size 35 Sqmm 3.5 core
All as per ser No.17.00 above but of Size 95 Sqmm 3.5 core
S & F Post top lantern 40 watt including dismantling taking down unsv one complete all as specified and directed. [Make- Bajaj, Model-ARIAN, BGCT W4 LED WW or equivalent of CG/ havells/ Philips/ Wipro]
S & F Post top lantern 40 watt watt including dismantling taking down unsv one complete all as specified and directed. [Make- Bajaj, Model-COSMOS, BGCT W4 LED WW or equivalent of CG/ havells/ Philips/ Wipro]
M&L for steel tubular swaged pole complete with cast iron base plate, finial taper plug bolts nuts and screws confirming to IS : 2713 and made out of structural steel tube confirming to IS: 1161 and painted internally with a coat of bituminous paint and externally one primer coat, one under coat and one finishing coat of aluminium paint as specified type 410, SP-31 (09 mtr long) including dismantling taking down unserviceable one complete all as specified and directed.
S & F MS cross arm, bracings, supports, clamps, nuts, bolts and washers on Pole including painting with one primer coat, one under coat and one finishing coat of aluminium paint including dismantling taking down unserviceable one complete all as specified and directed.
Supply and fixing PVC insulated, PVC round shethed copper flexible electric cable 1.5 sqmm 3 core, 1100 Volts grade and dismantling wornout/defective cables from SL/Flood light fitting at pole/tower top to JB at bottom of pole through pole / tower complete all as specified and directed. [Make : Plaza / Gloster/Havells/Polycab].
M&L for dismantling taking out cables 10 sqmm to 35 sqmm from trench, including making straight through joints at damaged portion and relaying to trench complete all as specified and directed. [Note: Earth work, cable protection pipe shall be measured and paid separately. Heat shrink straight through cable joints inclusive of quoted rate ]
S & F Bollard 10 watt, including dismantling taking down unserviceable one complete all as specified and directed, [Make : Bajaj Model-TULIP, BGBOM 650 9W LED or equivalent of CG/ havells/ Philips/ Wipro]
S & F Bollard 9 watt including dismantling taking down unserviceable one complete all as specified and directed. [Make- Bajaj, Model-MUSHRUMZ, BLBMC 9W WW LED or equivalent of CG/ havells/ Philips/ Wipro]
Attending electrical complaints and call on repair of control panel of street light, security light, garden light, perimeter light, tower light & high mast light provided inside Dockyard, decarbonizing all contact points of contactors, replacement of wornout aluminium cable lugs, wornout screws, nuts, bolts and washers, tightening the loose connections whereever required, adjustment of timer, cleaning and restore the power supply complete all as specified and directed. Note : (i) Replacement of spares viz MCB, MCCB, contactors, timers, cables, shall be measured and paid for separately as supply only and labour element for taking down the replaced spares shall be deemed to included in the unit rate quoted. (ii) If the qty of complaints to be attended in a control panel/LT panel is more than 01 No in a day, altogether the complaints will be considered only 1 (one). (iii) The contractor has to engage qualified electricians and helpers in sufficient Nos to attend and rectify the defects.
Supply only LED driver 58 watt suitable for Philips street light fitting 1 x 60 W / 2 x 60 W, 230V complete all as specified and directed. [Make- Philips only]
Supply only LED driver suitable for street light fitting 1 x 120 W , 230V complete all as specified and directed. [Make- CG/havells/Bajaj/Philips/Wipro]
Supply only LED driver suitable for street light fitting 1x 150 W , 230V complete all as specified and directed. [Make- CG/havells/Bajaj/Philips/Wipro]
Supply only LED driver suitable for flood light fitting 1x 200 W, 230V complete all as specified and directed. [Make- CG/havells/Bajaj/Philips/Wipro]
Supply only LED driver suitable for flood light fitting 1x 250 W, 230 V complete all as specified and directed. [Make- CG/havells/Bajaj/Philips/Wipro]
Supply only power contactor 3 phase, 415V, 32 amps cap utilsed for heavy duty by taking down the old perished / deteriorated contactor complete all as specified and directed. [Make: Schneider, Model-ETVS-LC1E3201 or equivalent of Legrand/L&T/ABB]
Supply only surface mounting Analog time switches heavy duty of 230 V, 50Hz including dismantling taking down unserviceable one and complete all as specified and directed [Make : 6499 15 Maxi Rex 4QT (daily) of Legrand or equivalent of ABB/L&T]
S&F street light bracket made with 40mm bore medium grade MS pipe, bent to shape of total length 1200 mm with 2 pair of MS clamp, nuts bolts washers painted with one coat of red oxide and two coat of aluminium paint including dismatling taking out unsv one complete all as specified and directed.
Supply and fix flood light fitting 60 Watt 230 volts made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 protection all as specified and as directed. [Make CG model no LFL-50-CDL/60-M)
S&F PVC junction box of out door type, weather proof, with provision of hole at bottom for cable entry, hinged door with locking arrangement, of size not less than 200mm (L) x 100mm (B) x 300mm (H) including taking down unserviceable one, fixed to pole with MS clamp, nuts, bolts and washers complete including one 3ph 4 pole connection block complete all as specified and directed. [Make- Syntex / hansel ]
SUPREET CONSTRUCTIONS
CIVILEC ENGINEERING WORKS
KIRON ENGINEERING CORPORATION
M/S SRI VENKATA BHAVANI CONSTRUCTIONS
SANTOSH CONSTRUCTIONS
UNITY PROJEKTZ
UNIVERSAL ENTERPRISES
M/s GOPALA KRISHNA ENGINEERING INDUSTRIE.
Sri Surya Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .