Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance HARDOI VAIT GANJ HARDOI HARDOI HARDOI HARDOI UTTAR PRADESH 241001 | HARDOI | UTTAR PRADESH | 241001 | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹24,120
Closing Date
18 Jul 2024, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
ASHA NAGAR HARDOI
ASHA NAGAR HARDOI
27/EDC(H)/2024-25
2024_MVVNL_936191_1
27/EDC(H)/2024-25
Open Tender
Miscellaneous Services
Item Rate
180 days
EDC HARDOI
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
A/C No. 066505005389, IFSC Code ICIC0000665, ICIC
₹24,120
2 Aug 2024
6 Jul 2024
19 Jul 2024
6 Jul 2024
18 Jul 2024
6 Jul 2024
Amount
Safe carriage, loading-unloading with proper stacking of following material from store centre Hardoi to pit site/JE dump store.
PCC Pole of size 8.5 mtr long
ST pole 11 mtr. Long.
Stay Set Complete
11 & 33 KV Pin with Net
Disc insulator With fitting (B&S) 70KN
MS Earthing Rod (2540x20 mm) With Fitting
ACSR Weasel Conductor
GI Wire
11 KV XLPE cable of size 3x70 sq mm.
11 KV XLPE cable of size (3X120, 3x185, 3X300 sq mm)
LT XLPE Cable Aluminium 3.5×240mm²
LT XLPE Cable Aluminium 3.5×400mm²
LT XLPE Cable Aluminium 1x240mm²
LT XLPE Cable Aluminium 1×400mm²
Dog/Rabbit conductor
ABC (1X16+1X25)Sq mm
ABC (3X50+1X35+1X16)Sq mm
ABC (3X95+1X70+1X16 Sq mm)
ABC (3X120+1X95+1X16 Sq mm)
Cable box (3X70/3X120/3X185/3X300) Indoor & Outdoor
Replacement of Broken PCC single Pole and Erection of PCC Pole 8.5 mtr long with Grouting & with all accessories.
Replacement of Broken PCC double Pole and Erection of PCC Pole 8.5 mtr long with Grouting & with all accessories
Replacement of Broken ST single Pole & Erection of ST Pole 11 mtr long with Grouting & with all accessories.
Replacement of Broken ST double Pole & Erection of ST Pole 11 mtr long with Grouting & with all accessories.
Re-Stringing of three phase ACSR Weasel Conductor for 11 KV line
Tilted of PCC/ST Pole
Rebinding of Stay Set
Laying of 11KV 3x70 sqmm single XLPE cable by digging of trench size 500 mm wide 900 mm after laying of brick, sand and stone slab. (Brick, sand and stone shall be provided by contractor)
Laying of 11KV (3X120, 3X185, 3X300 sq mm) single XLPE cable by digging of trench size 500 mm wide 900 mm after laying of brick, sand and stone slab. (Brick, sand and stone shall be provided by contractor)
Cable hoisting of 11 XLPE Cable on double pole (3X70, 3X120, 3X185, sq mm) including jumping etc. complete with help of GI Pipe as per RESPO Norms. (All the Material arrange by the contractor at his own cost)
Installation of Cable box11 KV Indoor & Outdoor
Installation of 33 KV Cable box Indoor & Outdoor
Stringing & Sagging of LT XLPE Cable Aluminium 1 * 400m * m ^ 2
Stringing & Sagging of LT XLPE Cable Aluminium 3.5 * 400m * m ^ 2
Stringing & Sagging of LT XLPE cable (1 * 240) sq.mm.
Stringing & Sagging of LT XLPE cable (3.5*240) sq.mm.
Stringing & Sagging ABC (1X16+1X25)Sq mm
Stringing & Sagging ABC (3 * 50 + 1 * 35 + 1 * 16) Sq mm
Stringing & Sagging ABC ( 3 * 95 + 1 * 70 + 1 * 16
Stringing & Sagging ABC ( 3 * 120 + 1 * 95 + 1 * 16
Placement of 11/0.4 KV T/Fs with the help of crane sleepers and man power etc, from dump place to newly constructed T/Fs plinth & erection & commissioning of 250/400/630 KVA T/Fs of T/F Plinth and including jumping with the system (All the required martial for above work shall be provided by 9500 contractor except T/Fs)
Fabrication erection and commissioning of 25/16/10 KVA T/F on double/single pole with all accessories All material except 25/16/10 KVA T/F shall be supplied by the contractor
Construction of retaining wall, fabrication & erection of Wire mesh fencing of size 3+38 20 M height around Transformer and Distribution Pillar Box with retaining wall & 1 no gate with locking arrangement made of MS Angle iron of size 50x50x6 mm jointed with nuts and bolts The panel must be supported with MS Flat of size 50x6 mm. Wire mesh of size 10 SWG rectangle type as per norms of RESSPO (All the material will be arranged by the contractor at his own. cost)
Construction of T/F plinth of size 2x2x1.5 m on a padding 0.25M deep in ground 1.5.10 cement sand and brick ballast on the top of padding brick work Ist class brick of 0.95 mtr high & 0.35 mir wall will be constructed ratio wall should be 0.23 mtr thick brick work in ratio 1.4 cement & cores Sand in the hollow portion the sand should be filled from the ground level up to 15 centimetre below from the top of wall. Cement, sand & brick Ballasts should be filled up to 15 centimetre Two no of channel 100x50 in length 1500mm will be grounded 0.35 CM.RCC will be done with cores sand, cement and stone ballast in the ratio of 1:2:4 The T/Fs plinth should be plastered on all sides 12mm thick in ratio 1:6 by cement and cores sand. (All the material will be arranged by the contractor at his own cost)
Erection of Stay Set Complete.
Fixing of Ordinary Earthing by 11 KV MS earth Rod 2500 mm long as per RESPO schedule.
Stringing of ACSR Weasel Conductor for 11 KV line
Stringing of Dog/Rabbit conductor for 33 KV line
Guarding of 33 KV Line
Looping & chopping of tree branches for clearance of H'T/LT line after clearance of line throughout pieces of tree branches of site (Approx 3
Neeraj Electricals
M/S RAJIV KUMAR SINGH
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .