GEMC-511687737583405
Awarded to SPARC INFOTECH PRIVATE LIMITED
₹93,000
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| BPE 5 KVA UPS 60 MINUTE BACKUP 8193 VAH | BPE 5 KVA UPS 60 MINUTE BACKUP 8193 VAH | - | 1 NOS | ₹93,000 | 93,000 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹93,000Qualified Make: BPE
Model: BPE 5 KVA UPS 60 MINUTE BACKUP 8193 VAH DELHI DELHI 110024 | SOUTH EAST DELHI | DELHI | 110024 | Make: BPE
Model: BPE 5 KVA UPS 60 MINUTE BACKUP 8193 VAH | L1 | Qualified | |
| 2 | L2₹1.1 L+₹15,213 (16.4%)Qualified Make: BPE
Model: BPE 5 KVA UPS 60 MINUTE BACKUP 8193 VAH AAREY MILK COLONY MUMBAI MAHARASHTRA 400065 | MUMBAI SUBURBAN | MAHARASHTRA | 400065 | Make: BPE
Model: BPE 5 KVA UPS 60 MINUTE BACKUP 8193 VAH | L2 | Qualified | |
| 3 | L3₹1.1 L+₹16,900 (18.2%)Qualified Make: LUMINOUS
Model: LUMINOUS 5KVA 1ST FLOOR F 05 PARKER SUITES NH 01 SECTOR 62 KUNDLI SONEPAT HARYANA 131028 SONEPAT SONIPAT HARYANA 131001 | SONIPAT | HARYANA | 131028 | Make: LUMINOUS
Model: LUMINOUS 5KVA | L3 | Qualified | |
| 4 | L4₹1.2 L+₹26,000 (28.0%)Qualified Make: ELECTRONICS and CONTROLS.
Model: E&C Make Renata i 5KVA Online UPS Single Phase Input and Single Phase Output with Minimum VAH 8193 29 A 2ND PHASE OPP TO ASIAN PAINTS GODOWN PEENYA INDUSTRIAL AREA BANGALORE KARNATAKA 560058 | BENGALURU URBAN | KARNATAKA | 560058 | Make: ELECTRONICS and CONTROLS.
Model: E&C Make Renata i 5KVA Online UPS Single Phase Input and Single Phase Output with Minimum VAH 8193 | L4 | Qualified | |
| 5 | L5₹1.3 L+₹32,500 (34.9%)Qualified Make: LUMINOUS
Model: LUMINOUS 5KVA RZ R 150 CHANAKYA PLACE PART 2 UTTAM NAGAR WEST DELHI D K MOHAN GARDEN WEST DELHI DELHI 110059 | WEST DELHI | DELHI | 110059 | Make: LUMINOUS
Model: LUMINOUS 5KVA | L5 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
9 Oct 2018, 4:00 pmClosed
Average Turn Over of Last 3 Years 4 Lakh (s) Online UPS ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 5.0 KVA 5.0 KVA Technology IGBT-PWM with inbuilt isolation transformer MOSFET-PWM with inbuilt isolation transformer
IGBT- PWM with inbuilt isolation transformer
IGBT-PWM without inbuilt isolation transformer Input Power single phase 160V - 260V sinewave
50Hz single phase 160V - 260V sinewave
50Hz
Three phase 300 V - 450V sinewave
50Hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz
3 Phase 400V +/-1% with alternative user setable setting of 380V +/-1% 50 Hz Backup time (Minutes) 60 60 1/4 Minimum VAH (VAH) 8193 400-640000 Warranty for UPS (Years) 2 1
2
3
4
5 Movable trolly for Batteries Without trollery but with rack With
Without
Without trollery but with rack Warranty for battery 2 1
2 Degree of Protection IP21 IP21
IP20 Cabling 5 meters for input and out put With With
Without Paralleling kit for synchronising Without With
Without Installation and Commissioning Yes * CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.2 * Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I
II&III) * FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 * Voltage Regulation from no load to full load (%) </= 3% * 20% Overload limit for minimum 10 minutes Yes * Overall Efficiency (%) >/=90% * Total Harmonic Distortion(THD) (%) Maximum 3% * 50% Overload limit for minimum 1 minutes Yes * PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes * Protection of Over voltage
Short Circuit & over load at UPS output terminal Yes * METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage
Output AC Volt age
Current
Frequency
Battery Voltage and Current Yes * Indicators for mains Yes * 2/4 presence
Battery charging and discharging
Output Over Load
Low Battery Voltage REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C
two cycles of (12+12) hours each 2007) Yes * Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes * Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes * Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes * Type Test Certificate No. - * Type Test Certificate date - * Name of Lab - * Address of Lab - * As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Namala Soma Sekhara Rao 515801
O/o Superintendent
RMS AG
Modinabad
Near Telephone Exchange
1 15 3/4 Guntakal
675648
GEM/2018/B/95788
GeM Contract
Online UPS
GeM Contract
Andhra Pradesh; Anantapur
PRODUCT
Awarded to SPARC INFOTECH PRIVATE LIMITED
₹93,000
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| BPE 5 KVA UPS 60 MINUTE BACKUP 8193 VAH | BPE 5 KVA UPS 60 MINUTE BACKUP 8193 VAH | - | 1 NOS | ₹93,000 | 93,000 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Average Turn Over of Last 3 Years 4 Lakh (s) Online UPS ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 5.0 KVA 5.0 KVA Technology IGBT-PWM with inbuilt isolation transformer MOSFET-PWM with inbuilt isolation transformer | - | - | - |
| IGBT- PWM with inbuilt isolation transformer | - | - | - |
| IGBT-PWM without inbuilt isolation transformer Input Power single phase 160V - 260V sinewave | - | - | - |
| 50Hz single phase 160V - 260V sinewave | - | - | - |
| 50Hz | - | - | - |
| Three phase 300 V - 450V sinewave | - | - | - |
| 50Hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz | - | - | - |
| 3 Phase 400V +/-1% with alternative user setable setting of 380V +/-1% 50 Hz Backup time (Minutes) 60 60 1/4 Minimum VAH (VAH) 8193 400-640000 Warranty for UPS (Years) 2 1 | - | - | - |
| 2 | - | - | - |
| 3 | - | - | - |
| 4 | - | - | - |
| 5 Movable trolly for Batteries Without trollery but with rack With | - | - | - |
| Without | - | - | - |
| Without trollery but with rack Warranty for battery 2 1 | - | - | - |
| 2 Degree of Protection IP21 IP21 | - | - | - |
| IP20 Cabling 5 meters for input and out put With With | - | - | - |
| Without Paralleling kit for synchronising Without With | - | - | - |
| Without Installation and Commissioning Yes * CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.2 * Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I | - | - | - |
| II&III) * FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 * Voltage Regulation from no load to full load (%) </= 3% * 20% Overload limit for minimum 10 minutes Yes * Overall Efficiency (%) >/=90% * Total Harmonic Distortion(THD) (%) Maximum 3% * 50% Overload limit for minimum 1 minutes Yes * PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes * Protection of Over voltage | - | - | - |
| Short Circuit & over load at UPS output terminal Yes * METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage | - | - | - |
| Output AC Volt age | - | - | - |
| Current | - | - | - |
| Frequency | - | - | - |
| Battery Voltage and Current Yes * Indicators for mains Yes * 2/4 presence | - | - | - |
| Battery charging and discharging | - | - | - |
| Output Over Load | - | - | - |
| Low Battery Voltage REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C | - | - | - |
| two cycles of (12+12) hours each 2007) Yes * Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes * Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes * Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes * Type Test Certificate No. - * Type Test Certificate date - * Name of Lab - * Address of Lab - * As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Namala Soma Sekhara Rao 515801 | - | - | - |
| O/o Superintendent | - | - | - |
| RMS AG | - | - | - |
| Modinabad | - | - | - |
| Near Telephone Exchange | - | - | - |
| 1 15 3/4 Guntakal | - | - | - |
Exempted
10 Oct 2018
10 Oct 2018
contract_GEMC-511687737583405.pdf
GEM_CONTRACT • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_675648.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .