Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAdmitted-Finance 47 11 6 19 3RD FLOOR ESWARAPALACE DWARAKANAGAR 1ST LANE DWARAKANAGAR VISAKHAPATNAM ANDHRA PRADESH 530016 UDYAM AP 03 0000458 36AAACL3798F1ZB B 37AAACL3798F1Z9 R MII STATUS AS NOT VERIFIED | VISAKHAPATANAM | ANDHRA PRADESH | 530016 | ₹1.2 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.4 Cr+₹23.5 L (20.2%)Admitted-Finance | ₹1.4 Cr+₹23.5 L (20.2%) | L2 | Admitted-Finance |
| 3 | Rejected-Technical 403 4TH FLOOR WAKEFIELD HOUSE BALLARD ESTATE MUMBAI MUMBAI MAHARASHTRA INDIA 400001 | MUMBAI | MAHARASHTRA | 400001 | - | - | Rejected-Technical NOT MEETING ELIGIBILITY CRITERIA |
| 4 | Rejected-Technical | - | - | Rejected-Technical NOT MEETING ELIGIBILITY CRITERIA |
| Sl No | Description | Qty | Unit | LASER SYSTMS PRIVATE LIMITED L1 | ACS Technologies Limited L2 |
|---|---|---|---|---|---|
| 1.00DESIGN, SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF MOBILE FLOOR MOUNTED DOUBLE SKIN CHILLED AIR SUPPLY SYSTEM [AIR HANDLING UNIT (AHU)] FOR CONSTRUCTION OF JETTY WITH COVERED SHED FOR LOADING/ UNLOADING FACILITY AT ND(V) as specified in Particular Specifications (Para 3 to 21.2 of Part II of RFP) | |||||
| 1.01 | CCTV Camera -16 Nos plus two TIC (Thermal Imaging Camera) with 40” LCD Monitor as specified in Para 3(a) of Part II of RFP. | 1 | Job | 48,50,000 ₹57,23,000 Lowest | 81,44,280 ₹96,10,250.4 |
| 1.02 | Servers (EBI Server PC, EBI Client PC, DVM Data Base server, DVM Camera Server, DVM Client PCs etc as specified in Para 3(b) of Part II of RFP. | 1 | Job | 29,90,000 ₹35,28,200 | 16,20,000 ₹19,11,600 Lowest |
| 1.03 | Tema Keys & Modules (Server for upto 16 temaline readers), TCP/IP connectivity, connection to field device via LAN works and Weigand / Door controller with 2 supervised digital inputs and 2 outputs as specified in Para 3(c) of Part II of RFP. | 1 | Job | 13,50,000 ₹15,93,000 Lowest | 20,95,548 ₹24,72,746.64 |
| 1.04 | Standard Accessories, if any (Refer to Para 6 of Part II) | 1 | Job | 50,000 ₹59,000 Lowest | - |
| 1.05 | Two years Operation & Maintenance spares, if any (Refers to Para 7 of Part II) | 1 | Job | 5,00,000 ₹5,90,000 Lowest | - |
| 1.06 | Special Maintenance Tools and test equipment, if any (Refers to Para 9 of Part II) | 1 | Job | 40,000 ₹47,200 Lowest | - |
| 1.07 | Technical Literature / certificates / documentation, if any (Refers to Para 10 of Part II) | 1 | Job | 29,950 ₹35,341 Lowest | - |
| 1.08 | Acceptance, Testing, Trials and Commissioning charges, if any (Refers to Para 11 of Part II) | 1 | Job | 30,000 ₹35,400 Lowest | - |
| 1.09 | Training, if any (Refers to Para 14 of Part II) | 1 | Job | 30,000 ₹35,400 Lowest | - |
Tender Value
Refer Docs
EMD Value
₹3.6 L
Closing Date
29 Sept 2020, 10:00 amClosed
DIRECTOR GENERAL
DIRECTOR GENERAL NAVAL PROJECTS, NAVAL BASE POST, NAVAL BASE, VISAKHAPATNAM -14
SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF CCTV CAMERA, SERVERS AND TEMA KEYS AND MODULES, TCP IP CONNECTIVITY, CONNECTION TO FIELD DEVICE VIA LAN WORKS AT NAVAL DOCKYARD VISAKHAPATNAM
2020_NAVY_371696_1
DGNP(V)/GP1/TOKEN 08 OF 2020-21
Open Tender
Electronics Equipment
Supply
240 days
CSFO, NAVAL DOCKYARD VISAKHAPATNAM
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
DGNP
₹3.6 L
Yes
PD AND CWE EQPT 2, CONFERENCE HALL, DGNP, VISAKHAP
27 Oct 2020
24 Aug 2020
30 Sept 2020
24 Aug 2020
29 Sept 2020
22 Sept 2020
24 Aug 2020 - 4 Sept 2020
7 Sept 2020
DESIGN, SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF MOBILE FLOOR MOUNTED DOUBLE SKIN CHILLED AIR SUPPLY SYSTEM [AIR HANDLING UNIT (AHU)] FOR CONSTRUCTION OF JETTY WITH COVERED SHED FOR LOADING/ UNLOADING FACILITY AT ND(V) as specified in Particular Specifications (Para 3 to 21.2 of Part II of RFP)
CCTV Camera -16 Nos plus two TIC (Thermal Imaging Camera) with 40” LCD Monitor as specified in Para 3(a) of Part II of RFP.
Servers (EBI Server PC, EBI Client PC, DVM Data Base server, DVM Camera Server, DVM Client PCs etc as specified in Para 3(b) of Part II of RFP.
Tema Keys & Modules (Server for upto 16 temaline readers), TCP/IP connectivity, connection to field device via LAN works and Weigand / Door controller with 2 supervised digital inputs and 2 outputs as specified in Para 3(c) of Part II of RFP.
Standard Accessories, if any (Refer to Para 6 of Part II)
Two years Operation & Maintenance spares, if any (Refers to Para 7 of Part II)
Special Maintenance Tools and test equipment, if any (Refers to Para 9 of Part II)
Technical Literature / certificates / documentation, if any (Refers to Para 10 of Part II)
Acceptance, Testing, Trials and Commissioning charges, if any (Refers to Para 11 of Part II)
Training, if any (Refers to Para 14 of Part II)
Any other item such as transportation, insurance, freight, packing etc
ACS Technologies Limited
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .