Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹42.1 CrAccepted-AOC 114 115 FIRST FLOOR AURORA TOWER EAST WING MG ROAD PUNE 411001 | PUNE | PUNE | MAHARASHTRA | 411001 | ₹42.1 Cr Quoted ₹420.7 Cr | 1 | Accepted-AOC PO Placed |
| 2 | 2₹495.3 CrRejected-AOC D 90 OKHLA INDUSTRIAL AREA PHASE 1 NEW DELHI NEW DELHI DELHI 110020 | SOUTH EAST DELHI | DELHI | 110020 | ₹495.3 Cr | 2 | Rejected-AOC Offer Not Considered |
| 3 | 3₹707.1 CrRejected-AOC S 2 TECHNOCRAT INDUSTRIAL ESTATE BALANAGAR HYDERABAD 500 037 TELANGANA INDIA | HYDERABAD | HYDERABAD | TELANGANA | 500037 | ₹707.1 Cr | 3 | Rejected-AOC Offer Not Considered |
Tender Value
Refer Docs
EMD Value
₹5 Cr
Closing Date
6 May 2023, 4:00 pmClosed
DMM(SB)III
MM Dept. Bijlee Bhavan, 2nd Floor, Kussara Bunder Road, Mazgaon, Mumbai-400010
Infrastructure work releated with Distribution Sub-Station Network in Mumbai at BEST Under RDSS
2023_BEST_888965_2
DMM(SB)/06/TCU-76350/2022-23/A
Open Tender
Supply, Erection and Commissioning
1460 days
Mumbai
Please refer Tender documents.
7 documents required · 7 mandatory
₹12,000
₹5 Cr
Yes
13 Jun 2023
14 Apr 2023
8 May 2023
14 Apr 2023
6 May 2023
14 Apr 2023
SUPPLY OF EQUIPMENTS
Supply of Normal VCB TYPE A:- 11kV, 250 MVA, Indoor, fault making, load breaking, Non-trip, Vacuum circuit breaker (Horizontal isolation and horizontal draw out type) with voltage transformer suitable for distribution automation along with spares and accessories.
Supply of Normal VCB Type B:- 11kV, 250 MVA, Indoor, fault making, fault breaking, Vacuum circuit breaker (Horizontal isolation and horizontal draw out type) suitable for distribution automation along with spares and accessories.
Supply of Normal VCB TYPE C: -11kV, 250 MVA, Indoor, fault making, load breaking, Bus coupler VCB (Horizontal isolation and horizontal draw out type) suitable for distribution automation along with spares and accessories.
Supply of Normal VCB TYPE D:-11kV, 250 MVA, Indoor, fault making, fault breaking, Metering vacuum circuit breaker (Horizontal isolation and horizontal draw out type) with Metering Voltage Transformer suitable for distribution automation along with spares and accessories.
Supply of Compact VCB TYPE A:- 11kV, 250 MVA, Indoor, fault making, load breaking, Non-trip, Vacuum circuit breaker (Horizontal or vertical isolation and horizontal draw out type) with voltage transformer suitable for distribution automation along with spares and accessories.
Supply of Compact VCB Type B:- 11kV, 250 MVA, Indoor, fault making, fault breaking, Vacuum circuit breaker (Horizontal or vertical isolation and horizontal draw out type) suitable for distribution automation along with spares and accessories.
Supply of Compact VCB TYPE C: -11kV, 250 MVA, Indoor, fault making, load breaking, Bus coupler VCB (Horizontal or vertical isolation and horizontal draw out type) suitable for distribution automation along with spares and accessories.
Supply of Compact VCB TYPE D:-11kV, 250 MVA, Indoor, fault making, fault breaking, Metering vacuum circuit breaker (Horizontal or vertical isolation and horizontal draw out type) with Metering Voltage Transformer suitable for distribution automation along with spares and accessories.
2 NOS OF SWITCHGEAR EARTHING G. I. WIRE 55 SQ.MM.(7/11 SWG) WITH 120SQMM AL LUGS AT BOTH ENDS WITH AVERAGE EARTHING WIRE OF 25 METERS (INCLUDING BOTH EARTHINGS) AT EACH DSS
RMU 3-WAY ( 1 ISO + 1 T-OFF+ 1 FDR.)
RMU 4-WAY ( 1 ISO + 1 T-OFF+ 2 FDR.)
RMU 4-WAY ( 1 ISO + 2 T-OFF+ 1 FDR.)
11KV/415V 630KVA DRY TYPE DISTRIBUTION TRANSFORMER
11KV/415V 630KVA (MINERAL OIL) DISTRIBUTION TRANSFORMER
11KV/415V 1000KVA DRY DISTRIBUTION TRANSFORMER
11KV/415V 1000KVA OIL DISTRIBUTION TRANSFORMER
11KV/415V 1600KVA DRY DISTRIBUTION SUBSTATION
11KV/415V 1600KVA OIL DISTRIBUTION SUBSTATION
11KV/6.6KV 3000KVA (MINERAL OIL) AUTO TRANSFORMER TYPE DISTRIBUTION SUBSTATION
CT’S HT 100/60-5 FOR 1600KVA TRFS ALONG WITH INSTALLATION
DWC HDPE PIPES 150 MM DIA.
SUPPLY OF CABLES & RELATED MATERIAL
FRLS CABLE SUPPLY 4C*2.5SQMM
LV 1C X 400 SQ. MM.XLPE CU.
11KV CABLES 3C*240 SQMM, XLPE, AL
11KV CABLE 3C*50SQMM, CU, XLPE
1.1KV 4C X 300 SQ. MM.XLPE AL
R.C.C. TILES FOR 11KV CABLES
SUPPLY OF 600 MM (+5%) CASING HDPE PIPE INCLUDING TRANSPORTATION, JOINTING, HANDLING, ETC. AT SITE
SUPPLY OF 160 MM HDPE PIPE INCLUDING TRANSPORTATION, JOINTING, HANDLING, ETC. AT SITE
SUPPLY AND INSTALLATION OF CABLE MARKERS AT BOTH THE ENDS OF RAILWAY BOUNDARIES AT 8 LOCATION, (2 NOS AT EACH LOCATION)
R.C.C. TILES FOR LT 1.1KV, 4C×300 SQ.MM. AL, XLPE CABLE
JOINTING & TERMINATION MATERIAL SUPPLY
1.1 KV LV 1C X 400 TERMINATION
11 KV 240/ 300 SQMM/3C, XLPE/PILC, AL HEAT SHRINKABLE TERMINATION KITS.
11 KV 50/70 SQMM/3C, CU/AL, XLPE HEAT SHRINKABLE TERMINATION KITS
1.1 KV, 4C×300 SQ.MM, HEAT SHRINKABLE TERMINATION KIT SUITABLE FOR ALUMINUM CONDUCTOR, DRY CURED, WATER SWELLABLE XLPE CABLE
1.1KV, 4C×300 SQ.MM. AL, XLPE CABLE HEAT SHRINKABLE STRAIGHT JOINTING KIT WITH MECHANICAL CONNECTOR SUITABLE FOR 1LT
11KV 240/ 300 SQMM/3C, XLPE/PILC, AL HEAT SHRINKABLE/EPOXY JOINTING KITS.
11KV, 3C×240 SQ.MM, HEAT SHRINKABLE STRAIGHT JOINTING KIT WITH MECHANICAL CONNECTOR SUITABLE FOR ALUMINUM CONDUCTOR, DRY CURED, WATER SWELLABLE XLPE CABLE
11KV, 3C×240 SQ.MM, HEAT SHRINKABLE TERMINATION KIT SUITABLE FOR ALUMINUM CONDUCTOR, DRY CURED, WATER SWELLABLE XLPE CABLE
Replacement of HV Weak/Old cable to improve the quality of supply (Rs 0.80 Cr per Km RI considered)
DISMANTLING OF EXISTING SWITCHGEARS, BACK TO BACK HT CABLE ARRANGEMENT INCLUDING MATERIAL COST, TRANSPORT OF OLD SWITCHGEARS TO BEST STORES IN MUMBAI
INSTALLATION, TESTING & COMMISSIONING OF SWITCHGEAR INCLUDING EARTHING, TRANSPORTATION TO SITE & MISC MATERIAL USED FOR INSTALLATION OF SWITCHGEARS
DISMANTLING OF EXISTING RMU, BACK TO BACK HT CABLE ARRANGEMENT INCLUDING MATERIAL COST, TRANSPORT OF OLD RMU TO BEST STORES IN MUMBAI
INSTALLATION, TESTING & COMMISSIONING OF RMU INCLUDING EARTHING, TRANSPORTATION TO SITE & MISC MATERIAL USED FOR INSTALLATION OF RMUS
DISMANTLING OF EXISTING TRANSFORMER INCLUDING TRANSPORT OF OLD TRANSFORMER TO BEST STORES IN MUMBAI
INSTALLATION, TESTING & COMMISSIONING OF NEW TRANSFORMER INCLUDING EARTHING CONNECTION, TRANSPORTATION TO SITE & MISC MATERIAL USED FOR INSTALLATION OF TRANSFORMERS
CABLE LAYING SERVICES
FRLS CABLE LAYING FOR COMMISSIONING OF DSS AND DSS EQUIPMENTS
EXCAVATION AND MAKING TRENCHES INCLUDING BREAKING EXISTING ASPHALT WITH PROPER BARRICADING, BACKFILLING & REMOVAL OF DEBRIS AFTER BACKFILLING
EXCAVATION AND MAKING TRENCHES INCLUDING BREAKING EXISTING PAVER BLOCKS/CHEQUERED TILES/BLACK STONE OR SIMILAR SURFACE WITH PROPER BARRICADING, BACKFILLING & REMOVAL OF DEBRIS AFTER BACKFILLING
LAYING OF HV CABLE PER RUNNING METER IN TRENCHES WHICH INCLUDES LAYING OF PIPES WHEREVER REQUIRED, PULLING OF CABLE (THROUGH EXCAVATED TRENCHES OR PIPES), BEDDING (BY SAND OR SIEVED EARTH) & TILING
RATE FOR LAYING OF HV CABLE BY HDD/TRENCHLESS TECHNOLOGY FOR CROSSING MAIN ROADS/JUNCTIONS WHICH INCLUDES DRILLING, LAYING OF PIPE WHEREVER REQUIRED, PULLING OF CABLE, BEDDING & TILING
DRILLING BORE BELOW THE RAILWAY TRACK BY HORIZONTAL DIRECTIONAL DRILLING (HDD) TRENCHLESS TECHNOLOGY OR BY OTHER EQUIVALENT METHOD AND LAYING OF HDPE 600 MM (+5%) PIPES THEREIN.
LAYING OF HDPE PIPE OF 160 MM INSIDE 600 MM (+5%) CASING HDPE PIPE.
PULLING LV/HV/EHV CABLES THROUGH 160 MM HDPE PIPES LAID UNDER THE RAILWAY TRACK IN A 600 MM (+5%) CASING HDPE PIPE.
EXCAVATION & MAKING OPEN TRENCHES FOR HDPE PIPE & CABLE LAYING BY OPEN TRENCHING METHOD WHICH INCLUDES BREAKING OF EXISTING FOOTPATH OR CEMENT CONCRETE RCC/ASPHALT AT THE JUNCTION/NEARBY RAILWAY & MCGM BOUNDARIES OR BENEATH PRIVATE PREMISES WITH PROPER BARRICADING, LAYING OF PIPES WHEREVER REQUIRED, PULLING OF CABLE, BEDDINGS, TILING, BACKFILLING, REMOVAL & DISPOSAL OF DEBRIS FROM THE SITE IN THE AREA OF ELECTRIC SUPPLY DISTRIBUTION OF THE BEST UNDERTAKING, MUMBAI AT VARIOUS LOCATIONS
LAYING OF LV CABLE PER RUNNING METER IN TRENCHES WHICH INCLUDES LAYING OF PIPES WHEREVER REQUIRED, PULLING OF CABLE (THROUGH EXCAVATED TRENCHES OR PIPES), BEDDING (BY SAND OR SIEVED EARTH) & TILING
RATE FOR LAYING OF LV CABLE BY HDD/TRENCHLESS TECHNOLOGY FOR CROSSING MAIN ROADS/JUNCTIONS WHICH INCLUDES DRILLING, LAYING OF PIPE WHEREVER REQUIRED, PULLING OF CABLE, BEDDING & TILING
MAKING OF JOINTS & TERMINATIONS
SERVICE FOR MAKING OF LV 1C X 400 TERMINATION
SERVICE FOR MAKING OF 11 KV 240/ 300 SQMM/3C, XLPE/PILC, AL HEAT SHRINKABLE TERMINATION
SERVICE FOR MAKING OF 11 KV 50/70 SQMM/3C, CU/AL, XLPE HEAT SHRINKABLE TERMINATION KITS
SERVICE FOR MAKING OF 11KV 240/ 300 SQMM/3C, XLPE/PILC, AL HEAT SHRINKABLE/EPOXY JOINTING KITS.
1.1KV, 4C×300 SQ.MM. AL, XLPE CABLE HEAT SHRINKABLE STRAIGHT JOINTING KIT WITH MECHANICAL CONNECTOR SUITABLE FOR 1
1.1 KV, 4C×300 SQ.MM. ALUMINUM CONDUCTOR, HEAT SHRINKABLE TERMINATION KIT SUITABLE FORDRY CURED, WATER SWELLABLE XLPE CABLE
SERVICES FOR MAKING OF 11KV, 3C×240 SQ.MM, HEAT SHRINKABLE STRAIGHT JOINTING KIT WITH MECHANICAL CONNECTOR SUITABLE FOR ALUMINUM CONDUCTOR, DRY CURED, WATER SWELLABLE XLPE CABLE
KEI industries Limited
MEGHA ENGINEERING AND INFRASTRUCTURES LIMITED
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid