Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.6 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹22.5 L+₹2.7 L (13.8%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹23.7 L+₹4.0 L (20.0%)Rejected-Finance RAM SHIV COLONY GALI NO 2 NAIKA CHATNAG ROAD JHUNSI PRAYAGRAJ UP 211019 | PRAYAGRAJ | UTTAR PRADESH | 211019 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹25.6 L+₹5.9 L (29.6%)Rejected-Finance 68 BANK COLONY SUNDER NAGAR PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹25.9 L+₹6.1 L (31.1%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
| Sl No | Description | Qty | Unit | JAI DURGA CONSTRUCTION CO L6 | M/S MALHI CONSTRUCTIONS L2 | M/s Sheetal Associates L7 | malghotra construction co L4 | TARA ENTERPRISES L3 | M/S PUSHPINDER ENGINEERS L1 | Mahashakti Enterprises L5 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil complete all as specified and directed. | 303.21 | Cum | 250 ₹75,802.5 | 170 ₹51,545.7 | 130 ₹39,417.3 | 125 ₹37,901.25 | 100 ₹30,321 Lowest | 100 ₹30,321 Lowest | 160 ₹48,513.6 |
| 2.00 | All as per Srl No 1 here-in-before but depth exceeding 1.5 metre but not exceeding 3.0 metre complete all as apecified and directed. | 1.21 | Cum | 250 ₹302.5 | 300 ₹363 | 150 ₹181.5 Lowest | 175 ₹211.75 | 150 ₹181.5 Lowest | 200 ₹242 | 160 ₹193.6 |
| 3.00 | Returning, filling in, including spreading, leveling, watering and well ramming in layers n.exc 25 cm complete all as specified and directed. | 168.63 | Cum | 65 ₹10,960.95 | 50 ₹8,431.5 | 60 ₹10,117.8 | 60 ₹10,117.8 | 30 ₹5,058.9 | 25 ₹4,215.75 Lowest | 45 ₹7,588.35 |
| 4.00 | Removal of excavated material to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 m high from the starting point complete all as specified and directed. | 135.78 | Cum | 65 ₹8,825.7 | 60 ₹8,146.8 | 60 ₹8,146.8 | 60 ₹8,146.8 | 50 ₹6,789 | 20 ₹2,715.6 Lowest | 45 ₹6,110.1 |
| 5.00 | Sand cushioning to underground cables complete all as specified in clause 19.75 of SSR Part laid before and after laying and testing of cables complete all as specified and directed. | 87.89 | Cum | 750 ₹65,917.5 | 500 ₹43,945 | 800 ₹70,312 | 1,000 ₹87,890 | 450 ₹39,550.5 | 400 ₹35,156 Lowest | 800 ₹70,312 |
| 6.00 | Material and labour for sub class (B* brick, old size, brick covering laid dry, flat transversally along the length of cable on sand cushioning, with width equal to the length of the brick complete all as specified and directed. | 8,680 | Each | 6 ₹52,080 | 6 ₹52,080 | 9 ₹78,120 | 6 ₹52,080 | 6 ₹52,080 | 5 ₹43,400 Lowest | 8 ₹69,440 |
| 7.00 | Supply & replacement of existing unserviceable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volt grade of crosssectional area 25 Sqmm 3.5/4 Core complete all as specified and directed. | 150 | RM | 250 ₹37,500 | 250 ₹37,500 | 250 ₹37,500 | 230 ₹34,500 | 220 ₹33,000 Lowest | 230 ₹34,500 | 245 ₹36,750 |
| 8.00 | All as per Srl No 7 here-in-before but of size 16 Sqmm 4 core | 400 | RM | 230 ₹92,000 | 200 ₹80,000 | 198 ₹79,200 | 190 ₹76,000 | 175 ₹70,000 Lowest | 195 ₹78,000 | 195 ₹78,000 |
| 9.00 | All as per Srl No 7 here-in-before but of size 16 Sqmm 2 core | 500 | RM | 150 ₹75,000 | 175 ₹87,500 | 130 ₹65,000 Lowest | 150 ₹75,000 | 145 ₹72,500 | 145 ₹72,500 | 145 ₹72,500 |
| 10.00 | All as per Srl No 7 here-in-before but of size 10 Sqmm 2 core | 500 | RM | 120 ₹60,000 | 150 ₹75,000 | 120 ₹60,000 | 125 ₹62,500 | 90 ₹45,000 Lowest | 120 ₹60,000 | 135 ₹67,500 |
Tender Value
Refer Docs
EMD Value
₹74,000
Closing Date
11 Jul 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Major S N Gaikwad
Holta Cantt Palampur
REPAIR REPLACEMENT OF UNSV STREET SECURITY LIGHT PTL LIGHTS FLOOD LIGHT TIMERS CENTRALIZED SWITCHING OF STREET AND SECURITY LIGHTS ALONGWITH OTHER ALLIED WORKS AT MIL STN DHARAMSHALA
2025_MES_714132_1
GEP-41/2025-26
Open Tender
Civil Works
Item Rate
180 days
Dharamshala Mil Stn
As per tender documents
8 documents required · 8 mandatory
₹500
GE Palampur
₹74,000
4 Sept 2025
13 Jun 2025
17 Jul 2025
13 Jun 2025
11 Jul 2025
27 Jun 2025
Amount
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil complete all as specified and directed.
All as per Srl No 1 here-in-before but depth exceeding 1.5 metre but not exceeding 3.0 metre complete all as apecified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n.exc 25 cm complete all as specified and directed.
Removal of excavated material to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 m high from the starting point complete all as specified and directed.
Sand cushioning to underground cables complete all as specified in clause 19.75 of SSR Part laid before and after laying and testing of cables complete all as specified and directed.
Material and labour for sub class (B* brick, old size, brick covering laid dry, flat transversally along the length of cable on sand cushioning, with width equal to the length of the brick complete all as specified and directed.
Supply & replacement of existing unserviceable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volt grade of crosssectional area 25 Sqmm 3.5/4 Core complete all as specified and directed.
All as per Srl No 7 here-in-before but of size 16 Sqmm 4 core
All as per Srl No 7 here-in-before but of size 16 Sqmm 2 core
All as per Srl No 7 here-in-before but of size 10 Sqmm 2 core
Supply and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor of size 16 sqmm, 2 core served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4mm suspension wire, one twin core cable flat or circular complete all as specified and directed.
Supply and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor of size 10 sqmm, 2 core served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4mm suspension wire, one twin core cable flat or circular complete all as specified and directed.
Supply and fix in replacement of existing unserviceable driver for LED fitting of capacity 25 Watt all as per sample and as directed by Engr-in-Charge.
Supply and fix in replacement of existing unserviceable driver for LED fitting of capacity 40/45 Watt all as per sample and as directed by Engr-in-Charge.
Supply and fix in replacement of existing unserviceable driver for LED fitting of capacity 60 to 75 Watt all as per sample and as directed by Engr-in-Charge.
Supply and fix in replacement of existing unserviceable driver for LED fitting of capacity 100 to 120 Watt all as per sample and as directed by Engr-in-Charge.
Painting to existing steel tubular poles 11/09 mtr long including cross arms, clamps etc. with two coats of aluminum paint on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with white and black paint alternatively on external surface above PCC copping including preparation of old painted surfaces by scraping complete all as specified and directed.
M & L for cutting of existing road/ floor/ plinth/drain for taking out/laying of UG cable through GI pipe including necessary earth work excavation and making good to match with existing surface complete all as specified with PCC 1:3:6 type C1 by (using 20mm graded stone aggregate) complete all as specified.
Supply and fixing in repairs post top lantern LED type 25 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
Supply and fixing in repairs post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
Supply and fixing in repair GI bracket as per site requirement for LED Street light complete with lamps, nuts , bolts and washers to fix the pole complete all as specified and directed by Engr-in-Charge
Supply and fixing in repair LED street light fitting 35 Watt, 230 V AC outdoor type with high pressure die, cast aluminum hosing and heat resistant, complete with driver with impact, and corrosion resistant including thermal, management in multiple optics complete with IP 66 protection complete all as specified and directed.
All as per Srl No 22 here-in-before Ditto but 60 watt.
All as per Srl No 22 here-in-before Ditto but 90 watt.
Supply and fixing in repair LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
Supply and fixing in repair LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP65/66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
Supply and fixing in replacement SMC cable junction box of size 140x140x95mm suitable for street light/PTL, square type , weather proof , IP-66 including fixing of 6 Amp MCB SP and clamps , nuts , bolts , washers suitable for fixing to pole/GI pipes including suitable arrangement for cable entry and exit with 2 run of 1.5 sqmm FRLS flexible cable laying through 15 mm light grade GI tubing from junction box to street light fitting complete all as specified and directed by Engr-in-Charge
Cutting/trimming tree branches along the over head LT lines up to 2.0 mtr from electric line on both sides of the span and disposing of the cut tree/branches at places as directed by Engr-in-charge.
M&L in repair for Structural steel work of existing unserviceable Cross arms bracing, supports, clamps and back plates fabricated from steel sections including nuts,bolts ,washers,welding ,bending cold or hot drilling holes for bolts in any shape or size as indicated or directed inclusive one coat of primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and directed.
Material and labour for replacement of existing unserviceable GI tubing light grade 50 mm bore for passing through cables under the floor ,along the wall or along the pole complete all as specified and directed .
Material and labour for replacement of existing unserviceable GI tubing light grade 40 mm bore for fixing of post top lantern & laying of UG LT Cable complete all as specified and directed .
M&L for replacement of old and weathered ACSR alluminium conductor of size 6/2.11 or 6/2.59 squirrel or weasel and with aluminium binding wire on poles etc traightening / tightening with mechanical devices, complete all as specified and directed.
Supply and fixed in replacement of galvanised steel wire 4mm dia to earth wire on LT poles for fabrication of cradles hexagonal/rectangular guards out of galvanised steel wire 4mm dia etc complete all as specified and directed.
Supply & replacement of existing unserviceable Wood/ PCC/steel tubular pole with new Steel tubular pole complete with cast iron base plate, finial taper plug, bolt, nuts & screws as specified type 410 SP-31 (9 mtr long ) Note: Excavation and PCC shall be measured and paid separately .
Supply & replacement of existing unserviceable Wood/ PCC/steel tubular pole with new Steel tubular pole complete with cast iron base plate, finial taper plug, bolt, nuts & screws as specified type 410 SP-31 (11 mtr long) complete all as specified and directed. Note: Excavation and PCC shall be measured and paid separately .
Supply and fixing (in replacement of existing UNSV PTL lights) Circular LED Post Top lantern of 45 Watt offering excellent uniform illumination and aesthetics in one go. Made up of pressure Die Cast aluminium body and opal PC cover with IP 66 and IK 07 with suitable size of GI Pipe light grade, PCC work and necessary excavation as per site required and as directed.
Supply and fixing (in replacement) of aesthetically disigned decorative hot dipped galvanised mild steel step pole for Post Top Light, circular base plate height upto 3 Mtrs with bottom dia 130 mm and Top dia 76 mm including foundation nuts, bolts and washers as required at site, necessary excavation and PCC 1:3:6 works as required at site and as directed.
Supply and fixing (in replacement) Cone NXG series LED light 8Watts acts as an imposing street furniture with touch of aesthietic, innovative design with uniformly lit diffuser at the upper portion acts a beacon op path guidance in a landscape environment with robust IP 65 rating complete with nut, bolts and washers as required at site, necessary excavation and PCC 1:3:6 works as required at site and as directed.
Supply and fixing (in replacement) solar street light 40 Watts is made with High efficiency Mono Crystalline Solar PV Moudle, Lithium Ferro Phosphate battery with in-built BMS technology, High efficacy LED, MPPT solar charge controller and aluminium extruded body & is specially programmed to automatically control the dimming and birghtness of light, which increeases the backup time complete with clamp, nut, and bolts as required at site and as directed.
Stay Assembly using stay rod of 20 mm dia complete with accessories as shown in EP No.1 of SSR 1991 Part I including galvanized steel stranded wire of size 7/4 mm complete all as specified and directed. Note: loop type insulator, earth work and PCC shall be measured and paid for separately.
M&L in replacement of existing unserviceable Shackle type porcelain vitreous white, brown or green insulator working pressure 1100 Volts of 90mm dia 75mm height including galvanized mild steel strip of size 31x3mm ,size 12mm dia insulator bolt,washers and nuts complete all as apecified.
Material & Labour PCC 1:4:8 type D2 ( using 40mm graded stone aggregate) as in bottom of pit in bed concrete of poles complete all as specified.
Material & Labour PCC 1:3:6 type C2 ( using 40mm graded stone aggregate) as in foundation of poles and stay etc complete all as specified.
Material & Labour PCC 1:2:4 type B1 ( using 20mm graded stone aggregate) as in coping for Poles etc complete all as specified.
Supply & replacement of diglital/auto/manual time switch with all fitting and as directed.
Comprehensive maintenance of DG Set including Alternator for routine check up of the engine for the smooth functioning and carrying out the checks complete as per the manufactures instructions all as specified and directed by the Engineer-in-Charge for 62.5 / 63 KVA DG Sets installed complete all as specified and directed. Make: As per held at site (A) Every 50 Hours/One month whichever is earlier (a) Repeat the daily checks (b) Check oil level in the oil bath type air cleaner (c) Check the fan belt tension. The deflection should be within 8 to 10mm at the Centre (for details please refer to the maintenance manual) (d) Check the electrical connection
Comprehensive maintenance of DG Set for routine checkup of the engine for the smooth functioning and carrying out the checks complete as per the manufactures instructions all as specified and directed by the Engineer-in-Charge for 62.5 / 63 KVA DG Sets installed complete all as specified and directed. Make : Make: As per held at site (a) Every 200 hours/Six month whichever is earlier (b) Repeat the 'A' Checks (c) Service the oil bath type air cleaner (d) Replace the engine main lub oil filter element & sealing ring (e) Grease the water pump bearing (f) Clean the button filter. Note for Srl Items No 1 & 2 : Servicing shall be carried out by authorized service Engineer of Make: As per held at site
Supply and fix (in replacement) old unserviceable Air filter suitable for 63 KVA DG Set complete all as specified and directed by Engr-in-Charge
Supply and fix (in replacement) old unserviceable oil filter element suitable for 63 KVA DG set complete all as specified and directed by Engr-in-Charge
Supply and fix (in replacement) old unserviceable fuel filter element suitable for 63 KVA DG set complete all as specified and directed by Engr-in-Charge
Supply and replacement of Automatic voltage regulator (AVR) suitable for DG Set 62.5 / 63 KVA complete all as specified.
Supply and fix (in replacement) ignition switch suitable for 63 KVA DG Set complete all as specified and directed
Supply and fix (in replacement) fuel level sensor suitable for 63 KVA DG Set complete all as specified and directed
Supply and fix (in replacement) oil level sensor suitable for 63 KVA DG Set complete all as specified and directed
Supply and fix (in replacement) fuel level gauge suitable for 63 KVA DG Set complete all as specified and directed
Supply and fix (in replacement) oil level gauge suitable for 63 KVA DG Set complete all as specified and directed
Supply and fix (in replacement) fan belt suitable for 63 KVA DG Set complete all as specified and directed
Renewal of belt tension unit for 62.5/63 KVA DG Set door hinges of suitable size for DG Sets complete all as specified and directed.
Supply and fix (in replacement) old unserviceable primmimg pump suitable for 63 KVA DG set complete all as specified and directed by Engr-in-Charge
Repair and servicing of 62.5 / 63 KVA Engine Kirlosker type RB 66 / Cummins turbocharger assembly and replacing the service kit and reassembling testing complete, all as specified.
Comprehensive maintenance of DG Set including Alternator AMF Panel for routine checkup of the engine for the smooth functioning and carrying out the checks complete as per the manufactures instructions all as specified and directed by the Engineer-in-Charge for 40 KVA DG Sets installed complete all as specified and directed. Make : Make: As per held at site (A) Every 50 Hours/One month whichever is earlier (a) Repeat the daily checks (b) Check oil level in the oil bath type air cleaner (c) Check the fan belt tension. The deflection should be within 8 to 10mm at the Centre (for details please refer to the maintenance manual) (d) Check the electrical connection
Comprehensive maintenance of DG Set for routine checkup of the engine for the smooth functioning and carrying out the checks complete as per the manufactures instructions all as specified and directed by the Engineer-in-Charge for 40 KVA DG Sets installed complete all as specified and directed. Make : Make: As per held at site (a) Every 200 hours/Six month whichever is earlier (b) Repeat the 'A' Checks (c) Service the oil bath type air cleaner (d) Replace the engine main lube oil filter element & sealing ring (e) Grease the water pump bearing (f) Clean the button filter. Note for Srl Items No 16 & 17 : Servicing shall be carried out by authorized service Engineer of Kirloskar
Supply and fix (in replacement) old unserviceable Air filter suitable for 40 KVA DG Set complete all as specified and directed by Engr-in-Charge
Supply and fix (in replacement) old unserviceable oil filter element suitable for 40 KVA DG set complete all as specified and directed by Engr-in-Charge
Supply and fix (in replacement) old unserviceable fuel filter element suitable for 40 KVA DG set complete all as specified and directed by Engr-in-Charge
Supply and replacement of Automatic voltage regulator (AVR) suitable for DG Set 40 KVA , complete all as specified.
Supply and fix (in replacement) ignition switch suitable for 40 KVA DG Set complete all as specified and directed
Supply and fix (in replacement) fuel level sensor suitable for 40 KVA DG Set complete all as specified and directed
Supply and fix (in replacement) oil level sensor suitable for 40 KVA DG Set complete all as specified and directed
Supply and fix (in replacement) fuel level gauge suitable for 40 KVA DG Set complete all as specified and directed
Supply and fix (in replacement) oil level gauge suitable for 40 KVA DG Set complete all as specified and directed
Suply and fix (in replacement) fan belt suitable for 40 KVA DG Set complete all as specified and directed
Supply and replace the lubricant oil (IC engine for Gen set application). Old oil should be drained out after warming the engine. (Use MIL-L 2104C mono-grade oils only/15W40 overlain cummins/equivalent) complete all as specified and directed by Engr-in-Charge
Supply only coolent suitable for above mention DG Set.
Suppy only distilled water.
Supply and replacement of battery 150 Ah suitable for DG Set, complete all as specified.
Servicing of radiator assembly complete for cleaning after draining out cooling water/coolant, spaces cleaning the inter coller and replace unserviceable rubber hose pipes, circlip clamps, cleaning of raditor mix with appropriate cleaning agent, de-scaling by means of scale solvent as well as neutralising agent to arrest leakages by means of brazing etc including replacement of coolant for the capacity of DG Set 62.5 KVA / 63 KVA all as directed by Engr-in-charge.
M & L complete dismantling, servicing and repairs to FIP (Fuel Injection Pump) by Supply & Fix of oil seals, 'O' rings, bearings, gaskets; reassembling the FIP, caryying out calibration by setting required pressure and testing of 62.5 KVA DG Set all as specified and directed.
Opening the coupling and dismantling the alternator carefully by removing the flywheel and dismantling the unservicable starting gear wheel , supply and fixing new starting gear for 62.5 KVA DG set ,complete all as specified.
Supply and replacement of LT Electro mat insulating mat conforming to IS 15652-2006 CPRI tested and certified pastable type, permanently fixed smooth trolley moment, moisture proof, fire retardant 2mm thick all as specified and directed Make : Electromat / Sentex / Jyoti
M & L taking down starter assembly, removing the wornout brushes and renewing the brushes as per manufacturer's specifications, checking commutatore surface, cleaning any dust, dirt, oil & foreign particles with dry clothesand compressed air; checking; repairing and greasing the drive assembly for the movement over soft spiness to enable drive assembly to move freely all as specified and directed.
Supply & Fix of exhaust silencer for 62.5 KVA DG Sets complete all as specified and directed.
Supply & Fix of solenoid switch for 62.5 KVA DG Sets complete all as specified and directed.62.5
Replacement of battery terminals of heavy duty brass with copper leads not less than 3 RM long - 02 No of suilable/existing size.
Supply only battery charger of capacity voltage 6 Volt to 24 volts, ampere rage 1 Amp to 12 Amps complete all as specfied and dircted.
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level, connecting to galvanised iron strip 32mm X 6mm (as earth lead strip), by means of bolt, nuts, check nuts and washer of GI and GI strip protected by provision of GI pipe light grade, 40mm bore upto test point including provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 25 x 25 x 3 mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at bottom 1.75 meters long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 mtr, all as per electrical plate No 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion. NOTE :- Item of earthing includes the cost of 7.5 meter long galvanised iron strip 32mm X 6mm size and protection pipe of 40 mm bore galvanised iron light grade.
M&L for earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground(earth plate not less than 2.25 mtr deep below the normal ground level ) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized earth wire 4mm dia by means of nuts bolts, washers, check nuts of iron or steel including test point PCC pits and RCC cover in PCC 1:2:4 (type B-1) including iron angle frame 40*40*6mm. and medium grade GI watering pipe 20mm dia with funnel and wire mesh and 15 mm bore GI pipe light grade protection pipe including excavation and charcoal ,common salt surrounded with 15cm all around the plate all as specified and shown in EP-3 of SSR Part-I and connection to earth test point all as specified and testing on completion.
Supply and replacement of galvanised iron strip 32x 6 mm and fixing screws buried in ground or above ground for test point complete all as specified.
Disconnecting the inlet and outlet connections from the electric circuit, taking out and strip opening and repair/replacement of defected parts in the 50 KVA voltage stabilizer. (i) Disconnecting the moving arm, servo motor, control circuit and provide minor items reqd in voltage stabilizer (ii) Complete servicing of the voltage stabilizer, setting the output voltage 440 volt accuracy + 1% variation, input voltage changes upto + 50% complete servicing and testing all as specified and directed by Engr-in-Charge. Note:-Make: As per held at site
Supply and fixing (In replacement) moving arm of 50 KVA voltage stabilizer 3 phase naturally oil cooled type complete all as specified and directed by Engr-in-Charge.
Supply and fixing (In replacement) servo motor of 50 KVA voltage stabilizer 3 phase naturally oil cooled type complete all as specified and directed by Engr-in-Charge.
Supply and fixing (In replacement) motor driver of 50 KVA voltage stabilizer 3 phase naturally oil cooled type complete all as specified and directed by Engr-in-Charge.
Supply and fixing (In replacement) control circuit of 50 KVA voltage stabilizer 3 phase naturally oil cooled type complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 125 Amps all as specified and as directed.
Taking down chowkhats or frames including shutters (without taking off shutters from the frame) not exc. 1.5 sqm each and removing from site, all as specified.
Taking down chowkhats or frames including shutters (without taking off shutters from the frame) exc. 1.5 but not exc. 4 Sqm each and removing from site, all as specified.
Taking down shutters not exc. 1.0 Sqm and removing from site, all as specified.
Taking down shutters exc. 1.0 Sqm but not exc. 2.0 Sqm each and removing from site, all as specified.
Demolition of brick/stone masonry built in cement mortar including all quions, arches, pillars etc but excluding ashlar facings dressed stonework and precast concrete articles
Hacking out old broken glass (any thickness, size, quality or description) form wooden frames or steel, concrete or brick surrounds, glazed with oil putty or fixed with beads, all as specified.
Taking down cement plaster on brick or stone surfaces etc. including raking out joints, hacking for key, scrubbing down with water etc. all as specified.
Demolition of cement concrete in ground floors and paving, not exceeding 15cm thickness (below or above ground level), un-reinforced, complete, all as specified.
Dismantling floor, hearth or wall tiling incl cement mortar bedding
Dismantling wrought iron or mild steel work of any description not otherwise provided for as specified and directed.
2nd class hard wood (Sal/Hollock) plain, solid, straight chowkhats or frames, wrought, framed, rebated on solid, rounded or chamfered, put together with glue, pinned at joints with one or more rebates, complete all as specified.
PCC (1:3:6) type C-1 using 20mm graded crushed stone aggregate as in back filling of chowkhat
Factory made 2nd class hard wood (Sal/Hollock) plain, framed, panelled 35mm thick shutters (two panels ) with lock rail and panels of 9mm BWP commercial plywood or 12mm veneered particle with commercial face veneers on both sides. The size of rail and style as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated, all as specified.
30 mm thick 2nd class hard wood (Sal/Hollock) glazed & skeleton factory made shutters, open rebated and prepared to receive glass, gauze etc (without sash bars), edges of framing plain, chamfered or rounded fitted with cut and mitered beads for securing glass, etc, for windows, ventilators, etc. are provided with stiles and rails as specified in SSR Part I, Section 8 clause 8.24(b) complete all as specified and directed.
Supply and fixing steel windows with side hung shutters inclduing projecting type hinges with steel handle and steel peg stay complete with glazings bards devetailed or welded all as specified and directed by Engr in Charge.
Aluminium, anodised, barrel tower bolts of extruded section and fixed with 150mm long bolt.
Aluminium, anodised, barrel tower bolts of extruded section and fixed with 100mm long bolt.
Butt hinges, medium weight, cold rolled, mild steel 100 mm long, all as specified.
Butt hinges, medium weight, cold rolled, mild steel 75 mm long, all as specified.
Anodized aluminium alloy handles, fabricated type, anodised or size 150mm, complete all as specified.
Anodized aluminium alloy handles, fabricated type, anodised or size 100mm, complete all as specified.
300mm long anodized aluminium alloy sliding door bolt, bolt type, stove enamelled black, with bright bolt not less 16mm dia, with and including a minimum of 6 bolts and nots, 4 on bolt plate and 2 on stapple plate, 300mm long, all as specified.
Mild steel galvanized wire cloth 0.56mm nominal dia of wire and average width of aperature 1.18 mm fixed with tinned tacks or wire staples or wooden beads, all as specified, fixed in repair complete all as specified and directed.
Sheet glass 3mm thick ordinary quality and glazing with oil putty/wooden beads in squares, not exc. 0.5 Sqm in each pane, all as specified.
M&L for 15mm thick plastering in cement mortar 1:4 on stone masonry surfaces or other than fair faces of brick surfaces, finished even and smooth without using extra cement, complete all as specified.
Rendering 10mm thick cement plaster on fair faces of brick work or concrete surfaces in cement mortar (1:6) finished even and fair without using extra cement all as specified and directed.
M&L for raised pointing to random or polygonal rubble, un?coursed or brought upto courses in CM 1:4 complete as specified.
Preparation of newly plastered wall surfaces and applying two coats of oil bound distemper over a coat of chalk whitening preparatory to distempering including preparation of surfaces, complete all as specified.
M&L for preparation of old decorated plastered or unplastered wall surfaces including cleaning by brooming down or with steel wire brushing, scrapping down smoke spot, moulds, moss and efflorescent salts and treating oil and greasy spots etc and applying one coat of distemper oil emulsion on wall all as directed by Engineer-in-Charge
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed.
Material and Labour for exterior painting work including complete removal of existing treatment till top surface of existing plaster and crack filling with crack seal upto 3mm where required and making good/smooth the surface with wall putty with silicon additives and sanding these surface for removal of loose particles and applying one coat of SmartCare waterproof primer (Damp Prime Suprema) on walls and chajjas with 10% of dilution of water and applying two coats of 100% acrylic smooth emulsion exterior grade with silicon additives and anti-algal properties (Apex Ultima Suprema).
M&L for PCC 1:3:6 type C2 using 40mm graded aggregate for subbase complete all as specified and as directed by Engr-in-Charge.
M&L for PCC 1:3:6 type C2 (using 40mm graded aggregate) in foundation, filling and mass concrete etc complete all as per specified and as directed by Engineer-in-charge.
M&L for PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in coping/benching etc including necessary formwork/ moulds complete all as specified and directed.
Mat finish (non skid), Premium class I grade, coloured ceramic tiles, 7 to 8mm thick (Square/rectangular) area of each tile exc. 0.06 Sqm but not exc. 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 15mm thick screed bedding layer in cement mortar 1:6 complete, all as specified.
Glazed ceramic tiles, Premium class I grade, coloured of size 450x300mm, thickness not less than 7mm as in vertical surfaces such as skirting/dado etc. set and jointed in neat cement slurry and pointed with white or coloured cement, laid over and including 10mm thick bedding layer in cement mortar 1:4 on surfaces of walls complete, all as specified.
M&L for Machine cut kota stone slab flooring 18-20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified & directed.
M&L for Kota stone slab 18-20mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified & directed.
M&L for chequered cement concrete tiles with grey cement and pigments 30 cm x 30 cm x 25mm thick over 20mm thk screed bed in cement mortar 1:4 set jointed and pointed in neat cement slurry in floors complete all as spd and directed.
S&F Bib taps for 15 mm bore pipe, cast copper alloy chromium plated fixed in repairs complete all as spd and directed.
Supply only pillar tap 15 mm bore chromium plated screwed down, high pressure screwed for iron pipe complete all as specified and directed.
S&F in repair 15mm bore CP angle valve cast copper screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe complete all as specified.
S&F Vitreous China wash basin, angle back, size 600x480mm white, including cutting for and pinning in ends of brackets or erecting stand including 15mm pillar taps, with 32mm chromium plated waste coupling, waste pipe of bore 32mm, PVC connection pipe 450mm long with brass nuts on both side, fixed in repairs, including bracket,s completed all as specified.
S & F mild steel angle iron in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified
M&L for rolled mild steel Fe 410-W (Gde E- 250) quality A in Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) all as spd.
Two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel or steel based surfaces of any description, exc. 10cm width or girth including preparation of surfaces, all as specified.
M & L appying two coats Synthetic enamel paint over a coat of pink primer on wooden surface any description over 10 cm in width or girth not otherwise described including preparation complete all as specified and as directed.
Welded steel wire fabric exc 4 kg per sqm supplied and fixed complete to wood or steel members as specified by Engr-In-Charge.
M&L for walling of random rubble stone masonry brought upto course well bonded bedded and solidly hearted built in CM 1:4 complete as specified
All as per srl item no 15 above but except stones.
M&L for brickwork with subclass 'B' Bricks straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as spd
All as per srl item no 15 above but except bricks.
Providing precast cement concrete type B-0 lourves and jallies 25mm thick (measured solid) set in CM 1:4 including all mouldings complete all as spd
M/S MALHI CONSTRUCTIONS (BID ID -3345827)
TARA ENTERPRISES (BID ID -3355408)
malghotra construction co (BID ID -3355134)
Mahashakti Enterprises (BID ID -3344332)
JAI DURGA CONSTRUCTION CO (BID ID -3345410)
M/s Sheetal Associates (BID ID -3347464)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .