| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.3 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹25.9 L+₹63,970 (2.53%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹26.2 L+₹95,350 (3.77%)Rejected-Finance D NO 32 1 211 2 BOWDARA ROAD VISAKHAPATNAM 530004 | VISAKHAPATANAM | ANDHRA PRADESH | 530004 | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹26.5 L+₹1.2 L (4.76%)Rejected-Finance | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹26.7 L+₹1.4 L (5.38%)Rejected-Finance H NO 8 9 29 ASOKE NAGAR OLD GAJUWAKA VIZAG 530028 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530028 | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹25.5 L
EMD Value
₹51,000
Closing Date
14 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I DM
NAVAL DOCKYARD VISAKHAPATNAM 530014
REPAIR, MAINTENANCE AND PERIODICAL CLEANING OF WATER SUPPLY INSTALLATIONS, UG/SEMI UG/OVERGROUND FRESH WATER RESERVOIRS AND CERTAIN MISC WORKS AT NAVAL DOCKYARD VISAKHAPATNAM
2020_MES_380284_1
SSGE/8305/E8
Open Tender
Civil Works - Water Works
Item Rate
270 days
NAVAL DOCKYARD VISAKHAPATNAM
As per tender documents
7 documents required · 7 mandatory
₹500
GE I DM
₹51,000
Yes
3 May 2021
23 Sept 2020
19 Oct 2020
23 Sept 2020
14 Oct 2020
7 Oct 2020
60 days
Amount
Material & labour for cleaning of clarifier cum sedimentation tank after every three month including dewatering by pump set to drain out chamber and removing upto 5 feet dirt, sediments etc., by using wire brush and other means from clarifier / inner / outer side walls inside / out-side chamber of clarifier including applying one coat of white wash on inner walls of clarifier complete all as specified and as directed Note:- clarifier -01 No
Material & labour for cleaning of semi underground sump of 2.5 lakhs gallon capacity at Main pump house after every six month and removing all scales, dirt and sediments etc., by using wire brush or other means from the floor and side walls of semi under-ground sump including washing the entire sump with bleaching powder complete all as specified and as directed (Sump 2.5 GLN-04 Nos)
All as per item No 2.00 above, but for under ground water sump capacity up to 0.8 lakhs ltrs (Bldg No SSS,DSC Block,DAS,20 MOUT,). (04 Nos)
All as per item No 2.00 above, but for under ground water sump capacity up to 2.27 lakhs ltrs (west wall sump,10 berth sump,old dock sump). (03 Nos )
All as per item No 2.00 above, but for under ground water sump capacity up to 1.5 lakhs ltrs (Low lift sump ). (01 No)
All as per item No 2.00 above, but for under ground water sump capacity up to 1.25 lakhs ltrs (DMC sump ).(01 No)
All as per item No 2.00 above, but for over head reservoir of capacity 1.25 lakhs gallons.(hill top) (06 Nos)
All as per item No 2.00 above, but for over head tank capacity 1.25 lakhs ltrs (DMC, 15 Bldg) (02 Nos)
All as per item No 2.00 above, but of 1.25 lakhs ltrs capacity O/H tank. (Recycle Tank) (01 No)
All as per item No 2.00 above, but for over head tank capacity 2.27 lakhs ltrs (West wall O/H,10 berth O/H, Old Dock ) (03 Nos).
All as per item No 2.00 above, but of 2.5 lakhs ltrs capacity collection chamber with channel (01 N0)
All as per item No 2.00 above, but of .5 lakhs ltrs capacity of back wash tank above filter bed bldg (01 N0)
All as per item No 2.00 above, but of water chanel 1.2 lakh ltr cap from filter bed to low lift sump.
All as per item No 2.00 above, but weekly cleaning, removing of all muds of filter back wash chanel including recycle tank at Filter plant. ( Note : Cleaning in each week shall be measured as one unit)
Chemical and biological testing of raw water from NABL accredited laboratory and submit the test report to the Engineer-in-Charge complete all as specified and as directed Note:- Sample to be collected from inlet source at FWPH
Chemical and biological test of treated water from NABL accredited laboratory and submit the test report to the Engineer-in-Charge complete all as specified and as directed. Note:- Sample to be collected from low lift pump house at FWPH
Cleaning monthly entire pumping installation of SSS Fire pumphouse bldg inside & outside walls, ceiling, floor, cable trench, pathway, doors, windows, drains by brooming, removing webs, cleaning of floors with wiper, Cutting /cleaning of wild vegitation etc., in and around water supply installation premises and location including disposal of spoil to a distance not excluding 50 mtr outside the installation complete all as specified and as directed. ( Note : Cleaning in each month shall be measured as one unit)
All as per item No 17.00 above but for DSC fire pump house
All as per item No 17.00 above but for 20 Mout fire pump house
All as per item No 17.00 above but for DMC pump house
All as per item No 17.00 above but for Old dockyard
All as per item No 17.00 above but for West wall pump house
All as per item No 17.00 above but for 10 bearth pump house
Cleaning of entire Fresh water pump house complex daily comprising Pump house office, SCADA Room, Main Pump House, Filter House, Low lift Pump House, Chlorine room, 5 LG Sump-2 Nos, Clerifier, Recycle tank, Recycle pump house, including removing of wild vegitaion around buildings, building internal cleaning of wall, roof, floor, maintenance and dressing of entire garden around buildings, watering of plants, cleaning of all outside walls of valve chambers, retaing wall, 5LG sump outside walls, trimming of grass/wild vagitation inside entire pump house complex, cleaning of filter bed wall, bed wash channel, washout channel, inner and outer wall of clarifier channel, Alumn mixing chamber, Chlorine mixing chamber, Raw water channel including removing fungus on wall/ full of all channel every day basis complete all as specified and as directed
Taking down unserviceable foot valve of size 200 mm bore from the suction line and supply, fix, testing and commissioning of CI foot valve 200 mm bore flanged type including replacing of bolts, nuts, washers and rubber gasket with new ones all as specified and directed
Taking down unserviceable foot valve of size 150 mm bore from the suction line and supply, fix, testing and commissioning of CI foot valve 150 mm bore flanged type including replacing of bolts, nuts, washers and rubber gasket with new ones complete all as specified and as directed.
Taking down unserviceable foot valve of size 100 mm bore from the suction line and supply, fix, testing and commissioning of CI foot valve 100 mm bore flanged type including replacing of bolts, nuts, washers and rubber gasket with new ones all as specified and directed.
Taking down unserviceable foot valve of size 80 mm bore from the suction line and supply, fix, testing and commissioning of CI foot valve 80 mm bore flanged type including replacing of bolts, nuts, washers and rubber gasket with new ones all as specified and directed.
Attending electrical complaints of electrical pump set/ starters / LT panels provided inside Dockyard , decarbonizing the , replacing lugs, wornout screws, nuts, bolts and washers, tightening the loose connections, replacement of contactors, timers whereever required and restore the power supply complete all as specified and as directed. Note : (i) Replacement of spares viz /CTs, MCCB, contracts, breakers, ACBs, starters will be measured and paid for separately as supply only and labour element for taking down the replaced spares shall be deemed to include in the unit rate quoted. (ii) If the No of complaints to be attended in a starter panel/LT panel is more than 01 No in a day, altogether the complaints is considered only 1 (one). (iii) The contractor has to engage qualified electricians and helpers in sufficient Nos to attend and rectify the defects.
Supply only MCCB, 3 pole, 250 amp, 36 KA braking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release complete all as specified and as directed Make- Schneider cat Part No- LV432893 or equivelent of Legrand/ABB
Supply only MCCB, 3 pole, 100 amp, 25 KA braking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release. Make- Schneider cat Part No- LV432693 or equivelent of Legrand/ABB
Supply only power contactor 3 pole, 110A, AC-3 rating complete all as specified and as directed Make- L&T, Model- ML-6 or equivelent of Legrand / Schneider
Supply only power contactor 3 pole, 300A, AC-3 rating complete all as specified and as directed Make- L&T, Model- ML-12 or equivelent of Legrand / Schneider
Supply only control relay, AC-15, 4A, 415V, with standard coil voltage 415V complete all as specified and as directed. Make- L&T, Model-MXO 22E or equivelent of Legrand / Schneider
Supply only timer for stater complete all as specified and as directed. Make- L&T, ET-100 or equivelent of Legrand / Schneider
Supply only thermal overload relay complete all as specified and as directed Make- L&T, MN-12 or equivelent of Legrand / Schneider
Supply only thermal overload relay complete all as specified and as directed Make- L&T, MN-2 or equivelent of Legrand / Schneider
Painting after preparation of old painted external wall surface of valve pits located along the main road with one coat of white wash complete all as specified and as directed
Painting after preparation of old painted external wall surface of pole copings located along main road with one coat of white wash complete all as specified and as directed
Painting of old painted steel surface of valve pits located along main road with one coat of synthetic enamel paint of existing tint complete all as specified and as directed
Painting of old painted steel surface incl necessary preparation of 20 HP / 150 HP pump set with one coat of synthetic enamel paint complete all as specified and as directed
Painting of old painted steel surface incl necessary preparation of 1 HP to 10 HP pump set with one coat of synthetic enamel paint complete all as specified and as directed
BHASKARA RAO CONSTRUCTIONS
S.M.Electricals
M/s Jai Ganesh Engineering Solutions
lakshmi Engineering Works
Jessica Engineering Works
B.Veerabhadra Rao
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .