Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.5 LAccepted-AOC THOTTAPALLY HOUSE EMILY P O KALPETTA WAYANAD DT | KALPETTA | WAYANAD | KERALA | 673121 | L1 | Accepted-AOC being lowest | |
| 2 | L2₹26.8 L+₹1.6 L (6.24%)Rejected-Finance BLDG NO XXVIII 378A NORTH CHAMPANOOR ANGAMALI SOUTH P O PIN 683 573 | ANGAMALI | ERNAKULAM | KERALA | 683573 | L2 | Rejected-Finance Other than lowest bidder |
Tender Value
₹22.9 L
EMD Value
₹45,860
Closing Date
3 Jun 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Fort kochi
GARRISON ENGINEER MILITARY ENGINEER SERVICES GE FORT KOCHI -682 001
AS PER BOQ AND TENDER DOCUMENTS
2021_MES_439595_1
8715/E8/GE Fort Kochi
Open Tender
Civil Works
Item Rate
180 days
Fort Kochi
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE Fort Kochi
₹45,860
Yes
16 Aug 2021
30 Apr 2021
5 Jun 2021
1 May 2021
3 Jun 2021
14 May 2021
60 days
Amount
Demolition of cement concrete unreinforced in ground floor or any floor level, terrazo flooring, kota stone, granite flooring, tiles flooring and pavings not exceeding 15cm thickness (below or above ground level) and removal unserviceable materials, debris and rubbish to a distance not exceeding 100m all as specified & directed by Engineer-in-charge.
M&L formwork to sides and soffits of floor or roof beam, beam haunchings, girders, bressumers,lintels cantilevers, shelves including supports,overhangs etc also splays between floors and beams etc & rough finished concrete surface all as specified & directed by Engineer-in-charge.
M&L mild steel TMT bars of dia 10mm and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, all as specified & directed by Engineer-in-charge.
All are as per item Ser No 3 above, but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders.
M & L RCC 1:1½ :3 using 20mm graded aggregate as in foundations , including rafts , footings , foundation beams, bases for columns etc , basement slabs , under reamed piles and mass concrete.
M&L Pre-cast cement concrete block masonry with solid blocks, exc 10 cm in width and setting in CM 1:6 type C1 1:3:6 (20 mm graded aggregate)all as specified & directed by Engineer-in-charge.
S&F Anodised aluminium powder coated frame for doors, windows, partitions, ventilators, with one or more rebates including joining cleat for fixing, all acessories complete all as specified
M&L for medium density fibre board 12mm thick, exterior grade, fixed to timber framework with screws, all as specified
M&L for double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed, all as specified
S&F Door closer hydraulically regulated(Aluminium extruded section body), designation No. 1 universal type, suitable for door shutters up to 700 mm in width and of weight not more than 35 kg and fixed,all as specified.
M&L rendering 10 mm thick on fair faces of brick work or concrete surfaces in CM 1:6, finished even and smooth w/o using extra cement, all as specified
M&L preparation of new plastered surface of wall including priming plastered and other surfaces with alkali resistant priming paint and applying two coats of oil bound distemper over a coat of wall primer,all as specified
M&L preparation of old plastered surface of wall including priming plastered and other surfaces with alkali resistant priming paint and applying two coats of oil bound distemper over a coat of wall primer,all as specified
M&L for preparation of old ceiling including priming plastered and other surfaces with alkali resistant priming paint and applying two coats of oil bound distemper over a coat of wall primer,all as specified
Dismantling wrought iron or mid steel work of any description not otherwise provided for ,all as specified.
S&F mild steel framed work as in door, gates of angle and other sections with gusset plates, rails, braces etc for covering doors etc, to be prepared for hanging or sliding inlcluding hooks and hinges and hanging complete (exclusive of steel sheeting) (Fe 410-W, Gde E-250, quality A) ,all as specified.
S&F plain or chequered plates square cut or notched (ordinary or counter sunk), forming holes with riveted, bolted or welded attachments (Fe 410-W, Gde E-250, quality A) ,all as specified.
S&F stainless steel grills/railings fixed to walls/concrete roof slab of Grade-316 including all pieces, drilling holes, sweling, buffing, complete all as specified and as directed.
Taking down cement plaster of any description on walls including raking out joints, hacking for key scrubbing down with water etc.,all as specified.
M&L for rendering 15 mm thick in two coats (10 mm thick in cement mortar 1:4 and 5 mm thick in cement mortar 1:4) mixed with water proofing compound) on other than fair faces of brick work or concrete surfaces finished even and smooth without using extra cement.(Note- water proofing compound shall be measured and paid separately) .
Supply only liquid water proofing admixture,all as specified.
M&L for two coats of Antifungal paint (Apex ultima Protek of Asian paint or Equivalent in approved Makes) over a coat of Exterior primer (Proffesional pack of Asian paints) over a coat of external wall care piutty n.exc 2 mm thick on new or old prepared plastered external surfaces and including scafoldings and cradles including hoisting and lowering as required with bracing , support complete all as specified.
M&L prepration of surfaces of ceiling by complete removal of existing treatement including priming plastered and other surfaces with alkali resistant priming paint and applying two coats of distemper oil emulsion on ceiling over a coat of primer ,,all as specified.
Complete removal of existing treatment of wall complete all as specified and directed.
M&L for 2 mm thick wall care putty on walls,all as specified.
M&L for preparation of new plastered surface of wall and applying two coats of oil bound distemper over a coat of primer,,all as specified.
M&L for preparation of old treated wooden surfaces over 10 cm width or girth and applying one coat of synthetic enamel paint all as specified and directed.
M&L for chip and remove all damaged and debonded concrete and plaster from the RCC slabs by manually or mechanically so as to expose the corroded reinforcement bars including the rent of tools ,labour charges for dumping the debris with in a lido of 100 meters as directed by Engineer-in-charge.
M&L for supply and application of Nitobond EP (Manufactured by M/s Fosroc chemicals India Ltd) epoxy bonding agent over the old concrete surface including the cost of all materials rent of tools , cost of painting brush and labour charges complete all as specified and all as directed by Engineer-in-charge.
M&L for plastering with Nitobond SBR (Styrene butadin polymer bonding agent cum cement mortar/concrete modifier Manufactured by M/s Fosroc Chemicals India Ltd) modified cement mortar (1:4) under the slab to an average thickness of 40 mm , including the cost of all materials rent of tools and labour charges etc complete all as directed by Engr-in-charge.
M&L providing cement concrete 1:2:4, type B-0, usisng 12.50 mm graded stone aggregate in roof kerbs, or mud stops, rounded or chamfered on edges all as specified and as directed.
Material and labour for point wiring with 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including PVC casing & caping of 20mm or higher complete with all accessories fixed to wall / ceiling and provision of modular metal flush box, modular white cover plate with frame, blanking plate etc and making good to the disturbed surfaces to match the existing complete all as specified and directed for one light / fan point controlled by one, one way switch 06 Amps.
All as per Serial Item No 32 here-in-before but one 3 pin socket outlet, 15 Amps, independent with cable 2.5 Sq mm size.
Supply and fix modular switch with indicator, 06 Amps, single pole, one way, 250 volts, one module and IP 20 protection complete all as specified & directed.
Supply and fixing modular switch with indicator, 16 Amps, single pole, one way, 250 volts, one module and IP 20 protection complete all as specified & directed.
Supply and fixing modular socket outlet 02 in 01, 03 pin, 06 Amps and 16 Amps, 02 module with shutter complete all as specified & directed.
Supply and fix ceiling rose, 6 Amp, 250 volt, AC, ISI marked with three equal size terminals and PVC / Polycarbonate insulated body of 50 x 25 mm size complete all as specified & directed.
Supply and fixing LED flame poof, weather proof fixture suitable for single T8 tube of 16w / 20w IP 65 protected ,all as specified. Make :Crompton EXTNILT8-16/20 or equivalent in Philips / Bajaj
Material and labour for wiring for circuit / sub main wiring with 2 x 6.0 Sq mm alongwith 1 x 6.0 Sq mm earth wire of FRLS PVC insulated copper conductor, single core cable drawning into and including rigid non-metallic PVC conduit of 25mm dia or higher complete with all accessories fixed to wall / ceiling,all as specified.
Supply and fixing single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB, 240 volt, 20 Amps complete all as specified & directed.
Supply and fix sheet metal enclosure distribution board, single pole and neutral, AC, 240 volts, 04 way with 200 Amps rated bus bar and double door complete all as specified directed.
Supply and fix sheet metal enclosure distribution board, single pole and neutral, AC, 240 volts, 02 way with 200 Amps rated bus bar and single door complete all as specified directed.
Supply and fixing of MCB, SP, AC, 240 volts of 06 to 32 Amps capacity complete all as specified & directed.
Supply and fixing of MCB, DP, AC, 240 volts of 63 Amps capacity complete all as specified & directed.
Supply, laying and testing cable XLPE Insulated, armoured heavy duty LT 1100 Volts grade with stranded aluminium condutor of c/s area 50 Sqmm 3.5 core in trenches / road crossing / on wall / panel all as specified & directed.
M & L excavation in trenches nexc 1.5 m wide nexc 1.5 m in depth getting out in soft and loose soil all as specified & directed.
M&L removing excavated soil to a distance nexc 50 Mtr and n.exc 1.5 Mtr above the starting point and depositing where as directed.
M&L sand cushioning in trenches using dry sand for cable cushioning all as specified & directed. Note: Thickness of sand cushioning after pumping down will be measured and paid.
M&L sub class B burnt bricks for protection of cable laid length of brick perpendicular to the lenth of cable complete all as specified & directed.
M&L returning and filling soil including spreading leveling watering and ramming in layers n.exc 25 cms complete in trenches all as specified & directed.
M&L for road cutting 0.45 m width and 0.6m depth including removing excavated material nexc 50 Mtr & depositing where directed,after laying of LT cable in trench, filling with of mass concrete PCC 1:4:8 D2(63 mm or 40 mm graded aggregate in road cutting portion (trenches), 0.45m wide and 0.50 m depth, further filling upto top 0.45m width and 10 cm depth with PCC 1:2:4 BI(20mm graded aggregate) and bitumen coating black paint over the surface complete all as specified / directed by Engr-in-Charge.
M&L GI tubing light grade 50mm bore for encasing of cable for mechanical protection laid under road crossing / floor/ path culvert / wall including its accessories
Supply and fix ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 125 Amps. Make : Havells / Standard / Seimens
Supply and fix 4 Pole MCCB 125 to 160 Amp, 50 Hz, 415 V with rupturing capacity 25 KA.(A frame) Make: Havells / Standard / Seimens
Supply and fix sheet metal enclosure suitable for 4 Pole MCCB 125 to 160 Amp.(A frame) Make: Havells / Standard / seimens
Supply and fix busbar chamber made out from sheet metal enclosure with 200 Amps rated bus bar 4 way, AC, 415 V. Make: Havells / Standard / Seimens
M&L for earthing complete with copper earth plate electrode 300 mm x 300 mm x 3.00 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to copper strip 20 x 3 mm by means of bolts nuts, check nuts & washers of copper, GI tubing 32 mm bore light grade, PCC (1:3:6) type C1, pre cost RCC(1:2:4) type B1 cover slab 545 x 545 x 5 cm with one handle for lifting, made out of 8mm dia ms bar, wiremesh, 20 mm bore GI tubing for watering, charcoal or coal and salt in alternate layers including excavation earth work complete, all as specified and directed.
Supply and fix copper strip 20 x 3 mm with saddles and fixing screws etc for roof conductors and down conductors above ground.
Supply, install, testing and commisioning of Inverter Split Air conditioner 1.5 TR capacity with copper condensor coil, cordless remote control, 5 Star rated, R32 refrigerant, AC,230 Volts, 50 Hz including all fixing, hoisting arrangements. Make :- Voltas/Blue star/Carrier/Mitsubishi.
Supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 170 volt to 270 volt with output voltage stabilized at 230 volt with accuracy of ± 2.5% and of capacity 4 KVA.
K R JOSEPH AND SONS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .