Vadodara Division: Provision of electrical protection devices in Low Voltage installations at various locations/stations over Vadodara division.
BRC-EL-P-09-2564-26-27
BRC-EL-P-09-2564-26-27
Open
6 Months
Vadodara, Gujarat
₹0
₹2.7 L
15 Jun 2026
15 Jun 2026
25 Jun 2026
A- Electrical works
Providing M.S. enclosure for MCCBs/RCBOs up to 40 Amp capacity - The price shall cover for providing M.S. enclosure fabricated from 18 1 SWG CRCA sheet steel, powder coated with grey enamel, dust and vermin proof, water resistant, outdoor type confirming to relevant IS for housing of MCCBs/ RCBOs up to 40 Amp capacity. The board shall fabricated for three-phase, four-wire, 440 Volt AC, 50 Hz supply system. The M.S. enclosure shall be provided with two earth terminals of 12.0 mm diameter and required quantity and size of cable glands.
Supply, installation, testing and commissioning of RCBO, two-pole, 20/25 Amp with outdoor type MS enclosure - The price shall cover for 3 supply, fixing, testing and commissioning of RCBO, two-pole, 20/25 Amp, 30 mA sensitivity conforming to IS 12640 (Part 1) / IEC 61008-1 in sheet steel modular enclosure or pre-fabricated double-door enclosure of same make as the RCBO as far as possible. The enclosure should be suitable for outdoor installation conforming to IP: 65 protection. The RCBO shall be of ABB/L&T/HPL/GE/MDS/Siemens/BCH/C&S/Schneider/CGL/Havells make.
Supply, installation, testing and commissioning of RCBO, two-pole, 32 Amp with outdoor type MS enclosure - The price shall cover for 4 supply, fixing, testing and commissioning of RCBO, two-pole, 32 Amp, 30 mA sensitivity conforming to IS 12640 (Part 1) / IEC 61008-1 in sheet steel modular enclosure or pre-fabricated double-door enclosure of same make as the RCBO as far as possible. The enclosure should be suitable for outdoor installation conforming to IP: 65 protection. The RCBO shall be of ABB/L&T/HPL/GE/ MDS/Siemens/BCH/C&S/Schneider/CGL/Havells make.
Supply, installation, testing and commissioning of RCBO, two-pole, 40 Amp with outdoor type MS enclosure - The price shall cover for 5 supply, fixing, testing and commissioning of RCBO, two-pole, 40 Amp, 30 mA sensitivity conforming to IS 12640 (Part 1) / IEC 61008-1 in sheet steel modular enclosure or pre-fabricated double-door enclosure of same make as the RCBO as far as possible. The enclosure should be suitable for outdoor installation conforming to IP: 65 protection. The RCBO shall be of ABB/L&T/HPL/GE/ MDS/Siemens/BCH/C&S/Schneider/CGL/Havells make.
Supply, installation, testing and commissioning of RCBO, four-pole, 40 Amp with outdoor type MS enclosure - The price shall cover for 6 supply, fixing, testing and commissioning of RCBO, four-pole, 40 Amp, 30 mA sensitivity conforming to IS 12640 (Part 1) / IEC 61008-1 in sheet steel modular enclosure or pre-fabricated double-door enclosure of same make as the RCBO as far as possible. The enclosure should be suitable for outdoor installation conforming to IP: 65 protection. The RCBO shall be of ABB/L&T/HPL/GE/ MDS/Siemens/BCH/C&S/Schneider/CGL/Havells make.
Supply, installation, testing and commissioning of RCBO, four-pole, 32 Amp with outdoor type MS enclosure - The price shall cover for 7 supply, fixing, testing and commissioning of RCBO, four-pole, 32 Amp, 30 mA sensitivity conforming to IS 12640 (Part 1) / IEC 61008-1 in sheet steel modular enclosure or pre-fabricated double-door enclosure of same make as the RCBO as far as possible. The enclosure should be suitable for outdoor installation conforming to IP: 65 protection. The RCBO shall be of ABB/L&T/HPL/GE/ MDS/Siemens/BCH/C&S/Schneider/CGL/Havells make.
Supply, installation, testing and commissioning of RCBO, four-pole, 63 Amp with outdoor type MS enclosure - The price shall cover for 8 supply, fixing, testing and commissioning of RCBO, four-pole, 63 Amp, 30 mA sensitivity conforming to IS 12640 (Part 1) / IEC 61008-1 in sheet steel modular enclosure or pre-fabricated double-door enclosure of same make as the RCBO as far as possible. The enclosure should be suitable for outdoor installation conforming to IP: 65 protection. The RCBO shall be of ABB/L&T/HPL/GE/ MDS/Siemens/BCH/C&S/Schneider/CGL/Havells make.
Supply, installation, testing and commissioning of RCBO, two-pole, 25/32 Amp in existing panel - The price shall cover for supply, fixing, 9 testing and commissioning of RCBO, two-pole, 25/32 Amp, 30 mA sensitivity conforming to IS 12640 (Part 1) / IEC 61008-1. The RCBO shall be installed in the existing panel and shall be compatible with the existing panel. The RCBO shall be of ABB/L&T/HPL/GE/ MDS/Siemens/BCH/C&S/Schneider/CGL/Havells make.
Supply, installation, testing and commissioning of RCBO, "B" series, two-pole, 25/32 Amp in existing panel - The price shall cover for 10 supply, fixing, testing and commissioning of RCBO, "B" series, two-pole, 25/32 Amp, 30 mA sensitivity conforming to IS 12640 (Part 1) / IEC 61008-1. The RCBO shall be installed in the existing panel and shall be compatible with the existing panel. The RCBO shall be of ABB/L&T/HPL/GE/ MDS/Siemens/BCH/C&S/Schneider/CGL/Havells make.
Supply, installation, testing and commissioning of RCBO, four-pole, 32 Amp in existing panel - The price shall cover for supply, fixing, 11 testing and commissioning of RCBO, four-pole, 32 Amp, 30 mA sensitivity conforming to IS 12640 (Part 1) / IEC 61008-1. The RCBO shall be installed in the existing panel and shall be compatible with the existing panel. The RCBO shall be of ABB/L&T/HPL/GE/MDS/ Siemens/BCH/C&S/Schneider/CGL/Havells make.
Supply, installation, testing and commissioning of RCBO, four-pole, 40 Amp in existing panel - The price shall cover for supply, fixing, 12 testing and commissioning of RCBO, four-pole, 40 Amp, 30 mA sensitivity conforming to IS 12640 (Part 1) / IEC 61008-1. The RCBO shall be installed in the existing panel and shall be compatible with the existing panel. The RCBO shall be of ABB/L&T/HPL/GE/MDS/ Siemens/BCH/C&S/Schneider/CGL/Havells make.
Supply, installation, testing and commissioning of RCBO, "B" series, four-pole, 32/40 Amp in existing panel - The price shall cover for 13 supply, fixing, testing and commissioning of RCBO, "B" series, four-pole, 32/40 Amp, 30 mA sensitivity conforming to IS 12640 (Part 1) / IEC 61008-1. The RCBO shall be installed in the existing panel and shall be compatible with the existing panel. The RCBO shall be of ABB/L&T/HPL/GE/ MDS/Siemens/BCH/C&S/Schneider/CGL/Havells make.
Supply, installation, testing and commissioning of RCCB, four-pole, 100 Amp with outdoor type MS enclosure - The price shall cover for 14 supply, fixing, testing and commissioning of RCCB, four-pole, 100 Amp, 30 mA sensitivity conforming to IS 12640 (Part 1) / IEC 61008-1 in sheet steel modular enclosure or pre-fabricated double-door enclosure of same make as the RCCB as far as possible. The enclosure should be suitable for outdoor installation conforming to IP: 65 protection. The RCCB shall be of ABB/L&T/HPL/GE/ MDS/Siemens/BCH/C&S/Schneider/CGL/Havells make.
Supply, installation, testing and commissioning of RCBO, four-pole, 63 Amp in existing panel - The price shall cover for supply, fixing, testing and commissioning of RCBO, four-pole, 63 Amp, 30 mA sensitivity conforming to IS 12640 (Part 1) / IEC 61008-1. The RCBO shall be installed in the existing panel and shall be compatible with the existing panel. The RCBO shall be of ABB/L&T/HPL/GE/MDS/ Siemens/BCH/C&S/Schneider/CGL/Havells make.
Supply, installation, testing and commissioning of MCCB, four-pole, 40 Amp in existing panel - The price shall cover for supply, fixing, 16 testing and commissioning of MCCB, four-pole, 40 Amp, with thermal-magnetic release range 32 - 40 Amp, Ics = 100% Icu having 35 KA breaking capacity and conforming to IS/IEC 60947-2 with adjustable overload and short circuit settings and inbuilt instantaneous protection of ABB/L&T/HPL/GE/MDS/ Siemens/BCH/C&S/Schneider/CGL/Havells make. The MCCB shall be supplied with spreader terminals and rotary handle and shall be installed in the existing panel. The MCCB should be compatible with the existing panel.
Supply, installation, testing and commissioning of RCBO, "B" series, four-pole, 63 Amp in existing panel - The price shall cover for supply, 17 fixing, testing and commissioning of RCBO, "B" series, four-pole, 63 Amp, 30 mA sensitivity conforming to IS 12640 (Part 1) / IEC 61008-1. The RCBO shall be installed in the existing panel and shall be compatible with the existing panel. The RCBO shall be of ABB/ L&T/HPL/GE/ MDS/Siemens/BCH/C&S/Schneider/CGL/Havells make.
Supply, installation, testing and commissioning of MCCB, four-pole, 125 Amp in existing panel - The price shall cover for supply, fixing, 18 testing and commissioning of MCCB, four-pole, 125 Amp, with thermal-magnetic release range 100 - 125 Amp, Ics = 100% Icu having 35 KA breaking capacity and conforming to IS/IEC 60947-2 with adjustable overload and short circuit settings and inbuilt instantaneous protection of ABB/L&T/HPL/GE/MDS/Siemens/BCH/C&S/Schneider/CGL/Havells make. The MCCB shall be supplied with spreader terminals and rotary handle and shall be installed in the existing panel. The MCCB should be compatible with the existing panel.
Supply, installation, testing and commissioning of MCCB, four-pole, 63 Amp with outdoor type MS enclosure - The price shall cover for supply, fixing, testing and commissioning of MCCB, four-pole, 63 Amp, with thermal-magnetic release range 50 - 63 Amp, Ics = 100% Icu having 35 KA 19 breaking capacity and conforming to IS/IEC 60947-2 with adjustable overload and short circuit settings and inbuilt instantaneous protection of ABB/L&T/HPL/GE/MDS/Siemens/BCH/C&S/Schneider/CGL/Havells make. The MCCB shall be supplied with spreader terminals and rotary handle in sheet steel modular enclosure or pre-fabricated double-door enclosure of same make as the MCCB as far as possible. The enclosure should be suitable for outdoor installation conforming to IP: 65 protection.
Supply, installation, testing and commissioning of MCCB, four-pole, 100 Amp with outdoor type MS enclosure - The price shall cover for supply, fixing, testing and commissioning of MCCB, four-pole, 100 Amp, with thermal-magnetic release range 80 - 100 Amp, Ics = 100% Icu having 35 KA 20 breaking capacity and conforming to IS/IEC 60947-2 with adjustable overload and short circuit settings and inbuilt instantaneous protection of ABB/L&T/HPL/GE/MDS/Siemens/BCH/C&S/Schneider/CGL/Havells make. The MCCB shall be supplied with spreader terminals and rotary handle in sheet steel modular enclosure or pre-fabricated double-door enclosure of same make as the MCCB as far as possible. The enclosure should be suitable for outdoor installation conforming to IP: 65 protection.
Supply, installation, testing and commissioning of MCCB, four-pole, 250 Amp in existing panel - The price shall cover for supply, fixing, 21 testing and commissioning of MCCB, four-pole, 250 Amp, with thermal-magnetic release range 200 - 250 Amp, Ics = 100% Icu having 35 KA breaking capacity and conforming to IS/IEC 60947-2 with adjustable overload and short circuit settings and inbuilt instantaneous protection of ABB/L&T/HPL/GE/MDS/Siemens/BCH/C&S/Schneider/CGL/Havells make. The MCCB shall be supplied with spreader terminals and rotary handle and shall be installed in the existing panel. The MCCB should be compatible with the existing panel.
Supply, installation, testing and commissioning of MCCB, four-pole, 400 Amp in existing panel - The price shall cover for supply, fixing, 22 testing and commissioning of MCCB, four-pole, 400 Amp, with thermal-magnetic release range 320 - 400 Amp, Ics = 100% Icu having 35 KA breaking capacity and conforming to IS/IEC 60947-2 with adjustable overload and short circuit settings and inbuilt instantaneous protection of ABB/L&T/HPL/GE/MDS/Siemens/BCH/C&S/Schneider/CGL/Havells make. The MCCB shall be supplied with spreader terminals and rotary handle and shall be installed in the existing panel. The MCCB should be compatible with the existing panel.
Supply, installation, testing and commissioning of MCCB, four-pole, 630 Amp in existing panel - The price shall cover for supply, fixing, 23 testing and commissioning of MCCB, four-pole, 630 Amp, with thermal-magnetic release range 500 - 630 Amp, Ics = 100% Icu having 35 KA breaking capacity and conforming to IS/IEC 60947-2 with adjustable overload and short circuit settings and inbuilt instantaneous protection of ABB/L&T/HPL/GE/MDS/Siemens/BCH/C&S/Schneider/CGL/Havells make. The MCCB shall be supplied with spreader terminals and rotary handle and shall be installed in the existing panel. The MCCB should be compatible with the existing panel.
Providing Measuring and Monitoring Relay (MMR) in existing Distribution Boards - The price shall cover for providing Measuring and 24 Monitoring Relay (MMR) in existing Distribution Boards. The MMR shall provide the following functions and protections - Voltage Protection - Protect against under voltage, overvoltage, and voltage drops. Current Protection - Monitor circuits for sudden over current or undercurrent faults to safeguard motors. Phase Protection - Monitor three-phase networks for phase loss, phase sequence (reverse phase), or phase asymmetry. The MMR shall be of L&T/BCH/C&S/CGL/Schneider/Siemens make.
Providing Power Contactor, two-pole, 32 Amp rating in existing Distribution Boards - The price shall cover for providing single-phase, two- pole, Power Contactor of 32 Amp rating, operating voltage up to 250 Volt (AC), Coil Voltage - 220/240 Volt (AC), DIN mounting. The Power Contactor shall be mounted in the existing Distribution Boards. The Power Contactor shall be of L&T/BCH/C&S/CGL/Schneider /Siemens make.
Providing Power Contactor, four-pole, 32 Amp rating in existing Distribution Boards - The price shall cover for providing three-phase, four- pole, Power Contactor of 32 Amp rating, operating voltage up to 440 Volt (AC), Coil Voltage - 415 Volt (AC), DIN mounting. The Power Contactor shall be mounted in the existing Distribution Boards. The Power Contactor shall be of L&T/BCH/C&S/CGL/Schneider /Siemens make.
Supply and laying three-core, multi-stranded, flexible copper cable, 2.5 sq. mm - The price shall cover for supply, fixing, testing and 27 commissioning of PVC insulated, multi-stranded, three-core, copper conductor cable, 2.5 sq. mm, 1100 Volt grade, ISI marked, conforming to IS: 694 or latest of Johnson /Neo-cab/Nicco/Finolex/R.R. Kabel/Asian/Ecotek/L&T/Havells/Polycab/Avocab make. The copper cable shall be laid in properly fixed PVC conduit of suitable size.
Laying of cable on wall/cover shed/existing tray with MS clamp - The price shall cover for laying, testing and commissioning of LTUG 28 armoured cable on wall/cover shed/in existing tray and its connection at both ends. The cable shall be tested with 500 Volt Megger before laying it in the tray. The cable cores shall be tested for continuity, absence of cross phasing, Insulation Resistance between conductors to earth/armour and between conductors. The results should be recorded in presence of railways' representative. A composite cable layout plan on ferro-print or computerized print duly laminated in A-4 size should be submitted by the contractor to site engineer and Divisional Office after laying of cable.
Providing M.S. enclosure for MCCBs/RCBOs above 63 Amp capacity - The price shall cover for providing M.S. enclosure fabricated from 18 29 SWG CRCA sheet steel, powder coated with grey enamel, dust and vermin proof, water resistant, outdoor type confirming to relevant IS for housing of MCCBs/ RCBOs above 63 Amp capacity. The board shall fabricated for three-phase, four-wire, 440 Volt AC, 50 Hz supply system. The M.S. enclosure shall be provided with two earth terminals of 12.0 mm diameter and required quantity and size of cable glands.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
RailwayBoardsletterNo.2018_CE-I_CT_9dated04.06.18.pdf
ATTACHMENT
WesternRailwaysSpecificationsforACBLTPanelsMCCBandMCB.pdf
ATTACHMENT
2024_06_03InstructionforincorporatingtheJPOCircularetc_ProvisionsintheTenderDocumentforallworksrequiringdiggingworksclosetoRly1.pdf for cable
ATTACHMENT
BankGuaranteeverification.pdf
ATTACHMENT
TenderDocument-BRC-EL-P-09-2564-26-27NEWGCC-Corr_1.pdf
ATTACHMENT
2024_06_03InstructionforincorporatingtheJPOCircularetc_ProvisionsintheTenderDocumentforallworksrequiringdiggingworksclosetoRly1.pdf
ATTACHMENT
Download all tender documents and submit your bid