Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1st₹6.9 LAccepted-AOC 67 NIRANJANPUR SAHARANPUR ROAD PO MAJRA DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | 1st | Accepted-AOC L1 | |
| 2 | 2nd₹7.3 L+₹5,471 (0.76%)Rejected-AOC 0 AJAY KUMAR 85 HASTAM HASTAM BANDA UTTAR PRADESH 210001 HASTAM BANDA UTTAR PRADESH 210001 UDYAM UP 13 0007628 | BANDA | UTTAR PRADESH | 210001 | 2nd | Rejected-AOC L2 | |
| 3 | 3rd₹9.2 L+₹2.0 L (27.8%)Rejected-AOC | 3rd | Rejected-AOC L3 |
| Sl No | Description | Qty | Unit | Bedi Refrigeration Works L1 | AJAY KUMAR CONTRACTOR L2 | PANTECH INSTRUMENTS AND SERVICES L3 |
|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches, not exceeding 1.5 m wide and n.exc 1.5 m in depth for foundation etc and getting out in Hard/Dense Soil complete all as speified and directed. | 60.59 | Cum | 150 ₹9,088.5 Lowest | 150 ₹9,088.5 Lowest | 400 ₹24,236 |
| 2.00 | Add to item 03006 for each additional 1.5m or part thereof in depth beyond the first 1.5m but not exc 3.00 mtr complete all as speified and directed. | 0.14 | Cum | 400 ₹56 | 100 ₹14 Lowest | 500 ₹70 |
| 3.00 | Returning filling in including spreading, leveling,watering and well ramming in layers not exc 25 cm in Hard/Dense Soil complete all as speified and directed. | 29.2 | Cum | 50 ₹1,460 Lowest | 90 ₹2,628 | 100 ₹2,920 |
| 4.00 | Removing excavated material n.exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point complete all as speified and directed. | 31.4 | Cum | 60 ₹1,884 Lowest | 100 ₹3,140 | 150 ₹4,710 |
| 5.00 | M&L for spread fine river sand in trenches complete all as specified ans as directed. Note: For measurement purpose, punned down thickness shall only be taken complete all as speified and directed. | 22.68 | Cum | 650 ₹14,742 | 450 ₹10,206 Lowest | 1,400 ₹31,752 |
| 6.00 | M&L for laying brick sub class 'B' old size burnt bricks for cable protection of size 230mmx115mmx75mm complete all as specified and as directed. | 2,435 | Each | 8 ₹19,480 | 5 ₹12,175 Lowest | 10 ₹24,350 |
| 7.00 | M&L for cement concrete 1:4:8 type D2 ( using 40mm graded stone aggregate) for foundation of pole / stay including form work etc complete all as speified and directed. | 3.88 | Cum | 6,000 ₹23,280 | 2,500 ₹9,700 Lowest | 5,000 ₹19,400 |
| 8.00 | M&L for cement concrete 1:3:6 type C1 ( using 20mm graded stone aggregate ) in coping of poles studs including form work etc complete all as speified and directed. | 0.5 | Cum | 5,500 ₹2,750 | 3,000 ₹1,500 Lowest | 6,000 ₹3,000 |
| 9.00 | Dismantling and taking out old unserviceable Tubular poles and struts of any size complete all as speified and directed. | 4 | Each | 1,000 ₹4,000 | 400 ₹1,600 Lowest | 1,000 ₹4,000 |
| 10.00 | Dismantling and taking down bend/damaged mild steel work such as cross arms, bracing, supported, clamps & back plates etc complete all as specified and directed. | 1 | Qtl | 500 ₹500 | 200 ₹200 Lowest | 2,000 ₹2,000 |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
1 Jul 2025, 6:00 pmClosed
AGE I Lansdowne
Asst Garrison Engineer (I) Lansdowne, Disst- Pauri Garhwal Pin-246155
REPAIR AND MAINTENANCE OF STREET LIGHTS AND CONNECTED WORKS AT KOTDWARA AND LANSDOWNE UNDER AGE (I) LANSDOWNE.
2025_MES_712256_1
9044/E8
Open Tender
Electrical and Maintenance Works
Item Rate
150 days
AGE I Lansdowne
All as per NIT and Tender Documents
6 documents required · 6 mandatory
₹500
AGE I Lansdowne
₹20,000
Yes
20 Aug 2025
3 Jun 2025
3 Jul 2025
4 Jun 2025
1 Jul 2025
18 Jun 2025
Amount
Excavation in trenches, not exceeding 1.5 m wide and n.exc 1.5 m in depth for foundation etc and getting out in Hard/Dense Soil complete all as speified and directed.
Add to item 03006 for each additional 1.5m or part thereof in depth beyond the first 1.5m but not exc 3.00 mtr complete all as speified and directed.
Returning filling in including spreading, leveling,watering and well ramming in layers not exc 25 cm in Hard/Dense Soil complete all as speified and directed.
Removing excavated material n.exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point complete all as speified and directed.
M&L for spread fine river sand in trenches complete all as specified ans as directed. Note: For measurement purpose, punned down thickness shall only be taken complete all as speified and directed.
M&L for laying brick sub class 'B' old size burnt bricks for cable protection of size 230mmx115mmx75mm complete all as specified and as directed.
M&L for cement concrete 1:4:8 type D2 ( using 40mm graded stone aggregate) for foundation of pole / stay including form work etc complete all as speified and directed.
M&L for cement concrete 1:3:6 type C1 ( using 20mm graded stone aggregate ) in coping of poles studs including form work etc complete all as speified and directed.
Dismantling and taking out old unserviceable Tubular poles and struts of any size complete all as speified and directed.
Dismantling and taking down bend/damaged mild steel work such as cross arms, bracing, supported, clamps & back plates etc complete all as specified and directed.
Dismantling insulators any type, any size complete all as speified and directed.
Dismantling stay assembly complete (demolition of concrete, etc. and excavation measured separately) complete all as speified and directed.
Dismantling of ACSR conductors, any size complete all as speified and directed.
Supply, laying & testing XLPE insulated screened PVC bedded galvanised steel strip or wire armoured, electric power cable (Heavy duty) with stranded aluminium conductor 1100 volts grade of size 10 Sqmm 2 core incl taking out old unsv cable from trenches all as specified and as directed. Note :- The earth work, GI pipe & Clamp for suitable size to hold the cable on wall shall be measured and paid separately under appropriate item of Sch A
All as item No 14 above but 16 Sqmm 4 core complete all as specified and directed.
Disconnecting and taking out old unserviceable GI Pipe and Supply, laying & jointing GI water tubing 40mm bore, light grade as in sleeving etc laid in trenches/pole post/under culvert/under road etc complete all as specified and directed.
Disconnecting and taking out old unserviceable GI Pipe and Supply, laying & jointing GI water tubing 50mm bore, light grade as in sleeving etc laid in trenches/pole post/under culvert/under road etc complete all as specified and directed.
S&F of steel tubular swaged poles complete as per IS-2713 MS base plate of size 300mmx300mmx6mm, final taper plug, bolts, nuts and screws as specified type 410 SP-31(9 mtr long) including painting two coats of aluminium paint over one coat of red oxide primer including 4 Nos band/straps with yellow and black colour in alternate way (250mm wide each) aluminium paint two coat at a distance 300mm from plinth block and marking pole nos with black paint including tarring one coat on steel surface embedded in concrete complete all as specified and directed. Note :- Necessary earth work and excavation, PCC in foundation 1:4:8 type D-2, using 40mm graded stone aggregate and PCC 1:3:6 type C-1, using 20mm graded stone aggregate as in plinth block, disposal of surplus soil to a distance not exceeding 50mmeasured and paid sepearately
M&L for cross arms, bracings, supports, clamps and back plates fabricated from steel section including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of synthetic aluminium paint complete all as speified and directed.
M&L for Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade complete all as specified.
M&L for shackle type insulators of 100mm high, 115mm dia porcelain, vitreous, white, brown or green insulators for working pressure 1100 volts including mild steel straps of size 31x5mm including 14mm dia bolts complete all as speified and directed.
Supply & Fixing stay assembly complete with all accessories, such as stay plate 300x300x6mm, stay rod 215cm long and 16mm dia with nuts including GI Bow turn buckle etc, all as per Electrical Plate No 1 SSR-2009 Part-I complete all as specified and directed. Note- Necessary excavation and PCC and one set of stay clamps at top of pole & loop insulator of size 90x140mm porcelain, vitreous, white, brown or green shall be measured and paid seperately.
S&F Galvanised stay wire of size 7/4mm complete all as speified and directed.
M&Lfor loop type insulator porcelain vitirious porcelain white, brown or green large size with overall dimensions 90 x 140 mm clearence of hole 25.5mm complete all as specified and directed.
Supply, streching and fixing of over head ACSR conductor of any size drawn straight horizontal on over head lines on poles including binding with insulators, jointing jumpers etc including connections of incoming and out going cables complete all as specified and directed.
Trimming up of tree branches upto 3 mtr all around LT overhead lines, removing cut branches from site complete all as speified and directed. Note :- (i) The overhead lines will be kept clear from all trees by trimming of tree branches with 3 mtr all around the line. Necessary permission will be obtained from department by contractor one day prior to trimming in particular area and shut down of that area will be arranged by department. (ii) Total length of line from supply point to load end will be measured for the purpose of payment, irrespective of the No of trees required to be trimed. (iii) Fortnightly inspection of lines will be made jointly by contractor or his authorised rep and rep of Engr-in-Charge and out come whether lines are free from tree branches or not kept on record for payment. No payment is made for whole length if even single tree is within reach of OH line. (iv) The OH line will be maintained for whole period of contract and the payment will be made with final bill only. The payment for the period for which line not maintained will be deducted proportionately based on fortnightly inspection carried out as detailed above. (vii) Quoted rates shall deemed to be included use of T&P. One span comprises of distance between one pole to another including all trees in its vicinity including switch off/on, electric cable connection or disconnection. Necessary permission will be obtained from department by contractor one day prior to trimming in particular area and shut down of that area will be arranged by department.
S&F in repair of MCCB 4 pole, 415 volt, adjustable thermal and magnetic release type 160 Amp breaking capacity 36 KA complete, including terminal links of suitable amp rating and size all as specified and directed.
S&F in repair of MCCB 4 pole, 415 volt, adjustable thermal and magnetic release type 100 Amp breaking capacity 16 KA complete, including terminal links of suitable amp rating and size all as specified and directed.
S&F in repair of MCCB 4 pole, 415 volt, adjustable thermal and magnetic release type 63 Amp breaking capacity 16 KA complete, including terminal links of suitable amp rating and size all as specified and directed.
S&F MCB, SP, AC, 240 volts of 06 to 32 Amps capacity 10 KA, 'C' Series and making connections with suitable size of copper lugs complete all as specified & directed.
S&F MCB, SPN, AC, 240 volts of 40 Amps capacity 10 KA, 'C' Series and making connections with suitable size of copper lugs complete all as specified & directed
Taking down of old U/S service cable and Supply, laying and fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium stranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 sq. mm 2 core all as specified and as directed.
M&L for replacement of heat shrinkable end termination cable jointing kit for PVC/XLPE insulated ,armoured electric cable of size upto 16 sqmm 4 core 1100 Volts garde for indoor/outdoor use complete with jointing materials and accessories complete all as speified and directed.
M& L for replacement of Cable lugs with aluminium alloy tubular bimetallic terminals of size 10 Sqmm incl crimping with help of crimping tools all as specified and directed .
All as per item No 34 above but of size 16 sqmm complete all as speified and directed.
All as per item No 34 above but of size 25 sqmm complete all as speified and directed.
All as per item No 34 above but of size 35 sqmm complete all as speified and directed.
Scraping of old paint from the steel tublar pole 9 mtr hight without removing accessories and Preparation surfaces for repainting. Repainting the pole with one coat of alternate black and yellow strips of 30 cm upto height of 1.5 mtr using synthetic enamel. Marking the pole number with black enamel paint. Repainting the remaining pole and iron parts steel cross arms i.e 'U' clamps etc above 1.5 Mtr height by applying two coat of synthetic enamel aluminium paint all as required at site and as directed.
Supply and fixing in repairs new LED street/security light fitting 60 Watt 230 V AC outdoor type, housing made out of high pressure die cast aluminum alloy with toughned glass, IP-66 protection, working on 240 volts, 50 Hz, consisting of reflective lens wired with appropriate driver PF>0.98 having over voltage protection upto 440 volts, surge protection level greater than equals to 10 KV, thermalk short circuit protection THD< 10% made up of long life LED chips (SMD) in modular with Ra>70, and LED lumen efficiency >140 lumen per watt, beam angle along the drive way, 120 degree, beam angle across the drive way, 80 degree luminior efficiancy > 110 Lumens/watt power LED should be of more than 01 watt CCT should be between 5700 degree K - 6500 degree K including connecting with 1.5 sqmm, 3 core, PVC insulated copper conductor cable 1100 Volts grade from pole box to light or from overhead conductor to light complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in repairs LED Flood Light 100 watt 230 V AC outdoor type, housing made out of high pressure die cast aluminum alloy with toughned glass, IP-66 protection, working on 240 volts, 50 Hz, consisting of reflective lens wired with appropriate driver PF>0.98 having over voltage protection upto 440 volts, surge protection level greater than equals to 10 KV, thermalk short circuit protection THD< 10% made up of long life LED chips (SMD) in modular with Ra>70, and LED lumen efficiency >140 lumen per watt, beam angle along the drive way, 120 degree, beam angle across the drive way, 80 degree luminior efficiancy > 110 Lumens/watt power LED should be of more than 01 watt CCT should be between 5700 degree K - 6500 degree K including fixed on pole of any type on existing angle iron with help of nuts bolts washer including connecting with 1.5 sqmm, 3 core, PVC insulated copper conductor cable 1100 Volts grade from pole box to light or from overhead conductor to light complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in repair bracket made out of 32mm bore, steel tubings, galvanised, light grade not less than 1.2 mtr long bend to shape with all fitting including fixed on pole with 02 Nos MS Clamp made out of F1 32x6mm complete all as specified and as directed
S&F in repair thermoplastic cable junction boxes/enclosure (Distribution Box) for outdoor installation with knockouts for cable entry suitable for cable size 16 to 25 Sqmm of dimension 200mmx140mmx95mm with cable terminals complete fitted on pole with suitable size of MS Clamps F1, nuts, bolts and washers, 01 No MCB SP 6 Amp and painting with two coats of synthetic enamelled paint over one coat of red oxide zinc chrome primer on clamps complete all as specified and directed.
S&F in repair thermoplastic service connection boxes/enclosure (Distribution Box) having busbar with screw bolt connection through fly nut for outdoor installation with knockouts for cable entry suitable for cable size 16 to 25 Sqmm of dimension 450x375x200mm with cable terminals complete fitted on pole with suitable size of MS Clamps F1, nuts, bolts and washers and painting with two coats of synthetic enamelled paint over one coat of red oxide zinc chrome primer on clamps incl connections of existing service cables with suitable size of thimbles complete all as specified and directed.
Supply and fix in repairs new LED Post Top Lantern Light fitting 15W housing made out of pressure die-cast aluminium alloy with toughned glass, IP-66 protection, working on 240 volts, 50 Hz, including connecting with 1.5 sqmm, 3 core, PVC insulated Copper conductor cable 1100 volts grade from pole box to light or from overhead conductor to light and suitable size & length of GI pipe complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in repair LED driver with PF>0.95, input voltage 240V AC, 50 Hz, input current 0.25 Amp AC, output voltage 42V-72V DC, output current 0.7A DC THD<10%, line voltage 140 to 277V, IP 20 protection as per IS:15885 (part-II section 13) suitable for LED street light of 25-45 watt outdoor dry and damp application after taking down the street light from pole/wall and refixing the street light on pole/wall (Size of driver should be as per sample given by Engr -in-charge complete all as specified and directed.
Supply and fixing in repair LED driver with PF>0.95, input voltage 240V AC, 50 Hz, input current 0.25 Amp AC, output voltage 42V-72V DC, output current 0.7A DC THD<10%, line voltage 140 to 277V, IP 20 protection as per IS:15885 (part-II section 13) suitable for LED street light of 50-90 watt outdoor dry and damp application after taking down the street light from pole/wall and refixing the street light on pole/wall (Size of driver should be as per sample given by Engr -in-charge complete all as specified and directed.
Supply, install and testing in repair LT Feeder pillar panel cubical outdoor type made out of CRCA sheet 3.00mm front hinged openable door including locking arrangement, platform mounted with angle iron 40mmx40mmx5mm frame work suitable for 240 volts grade three phase 4 wire 50 Hz AC Supply system, having bus bar chamber with suitable aluminium bus bar 100 Amp rating and accomodated with 63 Amp MCB TPN, with digital 24 Hr timer, contactors of suitable rating and making all necessary electrical connection complete, the box shall be dust and vermin proof IP-54 class protection alongwith in built short circuit protection conforms to IS/IEC 60947-4-1 complete all as specified and directed.
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. ( earth pit not less than 2.25 mtr depth below ground level at any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate. connected by 32x6mm GI strip as earth strip as earth lead by means of brass nuts and bolt, thimbles check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320x320x80mm size (1:2:4) Type B1 using 20mm graded stone aggregate rainforced with XPM all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI strip upto 7.5 mtrs long with 40 mm dia light grade GI pipe protection and watering pipe of GI 20 mm bore, medium grade, including all exavation and earth work and connecting the earthing strip to panel, including testing on completion complete all as specified and directed by Engr-in-charge. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick rainforced with XPM weighing not less than 4kg/sqm in lieu of CI cover. (ii) Cost of additional GI strip more than 7.5 mtrs will be measured and paid seperately under relevant items.
AJAY KUMAR CONTRACTOR (BID ID -3332828)
PANTECH INSTRUMENTS AND SERVICES (BID ID -3343312)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .