Loading…
Loading…
Tender Value
₹4.0 L
EMD Value
₹8,000
Closing Date
24 Jun 2026, 10:00 amDue tomorrow
Similar tender results from the same govt authority in the past 3 years.
Executive Engineer (C)
O/o the Estate Organization
Construction of 06 Nos. Type III of COHF Thunag at ATal Adarsh Vidalya Gudehari, Gohar, Mandi-remaining item thereof (SH-Providing Electrical Installation)
2026_YSPU_136824_1
No.UHF/Const-1/Part1/2026/-655 dated 16.06.2026
Open Tender
Electrical Works
180 days
Gudehari, Gohar
Please refer Tender documents.
4 documents required · 4 mandatory
₹700
Executive Engineer Design
₹8,000
16 Jun 2026
16 Jun 2026
24 Jun 2026
16 Jun 2026
24 Jun 2026
16 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLSPVC insulated copper conductor single core cable etc. as required compelete in all respect as persatisfaction of Engineer-in-charge. a) Group –A | 6 | Each | 516 | ₹3,096 |
| 2Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required compelete in all respect as per Satisfactionof Engineer-in-charge. | |||||
| 2.1 | a). 2 X 1.5 sq. mm | 930 | Running metre | 47 | ₹43,710 |
| 2.2 | b). 4 X 1.5 sq. mm | 524 | Running metre | 60 | ₹31,440 |
| 2.3 | c). 6 X 1.5 sq. mm | 304 | Running metre | 90 | ₹27,360 |
| 2.4 | d). 3 X 4 sq. mm | 475 | Running metre | 106 | ₹50,350 |
| 2.5 | e). 6 X 4 sq. mm | 100 | Running metre | 206 | ₹20,600 |
| 2.6 | f). 2 X 6 sq. mm | 24 | Running metre | 108 | ₹2,592 |
| 2.7 | g). 3 X 6 sq. mm | 12 | Running metre | 153 | ₹1,836 |
| 3 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required compelete in all respect as per Satisfactionof Engineer-in-charge. | 72 | Running Metre | 26 | ₹1,872 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.15 MB
tenderdoct.pdf
Tender Documents • 4.67 MB
BOQ_202497.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid