Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.2 CrAccepted-AOC B 116 VIBHUTI KHAND GOMTI NAGAR LUCKNOW UTTAR PRADESH 226010 | LUCKNOW | UTTAR PRADESH | 226010 | ₹14.2 Cr Quoted ₹16.3 Cr | L1 | Accepted-AOC Qualified |
| 2 | L2₹17.7 CrRejected-Finance | ₹17.7 Cr | L2 | Rejected-Finance Disqualified |
Tender Value
Refer Docs
EMD Value
₹29.6 L
Closing Date
11 Nov 2019, 5:00 pmClosed
Superintending Engineer
Superintending Engineer Construction Circle UKPJN Dehradun
Sunehra Pumping water supply Scheme in Roorkee City under AMRUT Programme
2019_MDPEY_20588_1
Letter No. 6848/NIVIDA/661, dated 03.10.2019
Open Tender
Civil Works
365 days
Roorkee
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,900
Executive Engineer PIU AMRUT
₹29.6 L
Dehradun
18 Jan 2020
5 Oct 2019
14 Nov 2019
5 Oct 2019
11 Nov 2019
11 Oct 2019
9 Oct 2019
Amount
TW2 TO OHT 1
200 mm dia 4.80 mm thick
Excavation of pipe line in soil mixed with singal,boulder,bajari etc requring use of T&P if any for pipe line trenches ie lead up to 1.5 m ,lift up to 30m, including refilling of trenches after laying of pipe line including watering ramming etc.
Dismantling of following type of road surfaces for laying of pipe line including sorting out of serviceable materials and disposal of unserviceable materials.
Cement concrete road
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
355 mm HDPE
315 mm HDPE
250 mm HDPE
200 mm HDPE
160 mm HDPE
110 mm HDPE
Providing of all materials, carting from site store to site of work, lowering into trenches with true to alingment, laying and jointing of full length S&S centrifugally cast Ductile Iron pipe K-7 confirming to IS 8329/2000 including supply of EPDM rubber gasket ISI marked confirming to IS 5382-1985 with testing of pipe line complete
350 mm dia
Supply and fixing of R/F compatible water meter type - B
Supply & fixing of following CI D/F sluice / Gate valve for flow regulation & scouring PN-1.6
Air valve 25 mm dia
Fire hydrant 80mm dia
Constructing masonry Chamber with 75 class designation brick work in cement mortar 1:4(1 cement: 4 corase sand ) for Sluice valve/ Gate valve, Air volve/ fire Hydrant etc with C.I. with hinge cover fixedin RCC slab 1:1.5:3 cement sand and 20mm grit necessary excavation foundation concrete 1:5:10 and inside plastering 12 mm thick with cement mortar 1:3 finished with floating coat of neat cement (chambers as per type design) including supply of all materials labour T&P etc complete
(i) Sluice valve/ wheel valve chamber(0.90X0.90X100) cm
(i) Sluice valve/ wheel valve chamber(1.20X1.20X1.00)
Air valve chamber / Fire Hydrant chamber (0.60X0.60X0.75)
Providing household connection including supply of all material, labour T&P etc complete.
Supply of all materials, labour, T&P etc and construction of R.C.C. O.H.T. of following capacities ( in kiloliters ) and 12 m. staging with 1.00 m wide R.C.C. stair case from G.L. to balcony and from balcony to top dome 1m x 1m R.C.C. landing at suitabl locations and railed with 3 rows of 20 mm dia G.I. (M) pipe on 65x65x5 mm angle iron posts fixed with ladder, from top to the floor inside of the tank, M.S. M.H. cover with locking rangement, lightning conductor as per electricity rules, water level indicator, supply and fixiing of outlet, inlet, over flow and wash out pipes with necessary sluice valves, pipe pieces (including cost of materials) flooring 0.60 M wide apron, painting on tank body vertical pipes, ladder, M.S. M.H. cover, ventilator columetc. complete with approved water proofing (apex) / enamal paint, testing, filling water for testing purpose etc. including supply of vertical pipes and specials, assuming bearing capacity as 8MT /M2.
22 m staging (900KL)
23 m staging (850KL)
Supply of all materials and construction of pump house cum chloronome as per type design and drawings.
Supply of all materials and Construction of boundary wall as per type design of Jal Nigam.
Fixing of 3.6m wide M.S. gate with wicket gate including fabrication and supply of steel and construction of Gate complete as per drawing.
Earth / sand filling as direction of Eng-Encharge.
Construction of Tubewell as per IS Code- IS2800 (Part-1) - 2001 & testing of tubewell as per IS Code- IS2800 (Part-2) - 1999. Mathod of Drilling Specified by Bidder
Transportation of heavy duly drilling machine with all T&P & accessories and connected T&P and plant upto the site i.e. for each tubewell.
Drilling of bore upto 150 mtr depth below ground leval in all type of soil/ under ground condition with DC/RC ring machine or suitable method suitable to discharge as desired with desired bore dia as per instruction of Engineer- in- charge
Supply & Lowering of tubewell assembly 300 mm dia & 200mm dia, 7.9mm thick MSERW pipe confirming to to IS code IS code IS 4270 or latest amended with maintaining the verticality of assembly and welding/ jointing properly as per direction of Engineer-in –charge.(pipe make-Jindal, Swastik, TATA)
300 mm dia MSERW plain pipe 7.9mm thick.
300 m dia MSERW slotted pipe 7.9 mm thick. (Solt as per IS Code IS8110:2000 in zigzag pattern)
200 mm dia MSERW plain pipe 7.9 mm thick.
200 m dia MSERW slotted pipe 7.9 mm thick. (Solt as per IS Code IS8110:2000 in zigzag pattern)
Supply of 200x100mm size M.s Girder 4 mtr long for tubewell assembly
S/F of Bail plug to plug the tubewell at bottom with providing hook of suitable dia. (Parameter shall be as per the assembly)
S/F of 300 mm dia MS clamp with nuts & bolts
Supply of pea gravel confirming to IS code IS460-1962 and of 2.00 mm to 4.00 grit size.
Shrouding of pea gravel upto 150 mtr. BGL for each tubewell.
Development of Tubewell by air compressor 1400/1100 CFM, 350/250 psi and eduction line if required to get the sand free discharge as per IS Code- IS1189-1999
Development of tubewell with O.P. unit atlest for 60% over pumping than the required discharge including supply and installation of over pumping unit to get the sand free discharge.
Supply & fixing of 300 mm dia MS tubewell cap as per specification of assembly.
Reducer/enlarger 300mm*200mm of 7.9mm Thickness MS for use of Reducer /Enlarger
Logging with electronic/analog logging machine complete with logging graph in such a manner that clear drilling of required dept available at the time of lowring of assembly.
Chemical and bacteriological testing of water sample as per IS Code IS10500:2012 from NABL approved lab for all parameters.
Supply & Installation of 2000 L.P.M & 75 mtr. Head Pumping Plant & Accessories at sunehra T.W No 1 & 2 (Pumping plant with great efficiency shall be offered to supply). The contractor has to give rate for given head and discharge and submit spacifications as required by the Nigam, However, In case the actual head at site changes within 10%(+ or -) either side, the contractor has to provide pump of required head and discharge at the same rate as already quoted by the firm and no extra payment will be made to the contractor for the above variation. moreover the contractor has to submit the revised spacification and design as required by the Nigam.
Supply of submersible pumping plant capable of delivering 2000 lpm discharge at 75mt. head with 10% shut off head including electric motor to be operated on 415 (+\-)10% volts,3 phase,50 C\s AC at 2900 RPM nominal speed along with submersible cable supplied by the manufacturer with pump.
Supply of spare pumping plant as 27.01
Supply of electrical panel with fully automatic starter suitable to be operated on 415 (+\-)10% volts,3 phase with neutral 50 C/S AC with panel suitable for above pump set along with all safety devices i.e. single phase preventer, earth fault relay, electronic over load relay, over /under voltage relay & Auto phase reversal unit complete in all respect supplied by OEM only with copper strip for power wiring inside panel.
Supply & Installation of 2000 L.P.M Pumping Plant & Accessories at sunehra T.W No 1 & 2 (Pumping plant with great efficiency shall be offered to supply) additional for each head variation from 10% to 25% for each ± 10mtr head variation as detailed below :-
Supply of submersible pumping plant capable of delivering 2000 lpm discharge at 55mt. head with 10% shut off head including electric motor to be operated on 415 (+\-)10% volts,3 phase,50 C\s AC at 2900 RPM nominal speed along with submersible cable supplied by the manufacturer with pump. (considering head variation)
Supply of spare pumping plant as 71.3
Supply of electrical panel with fully automatic starter suitable to be operated on 415 (+\-)10% volts,3 phase with neutral 50 C/S AC with panel suitable for above pump set along with all safety devices i.e. single phase preventer, earth fault relay, electronic over load relay, over /under voltage relay & Auto phase reversal unit complete in all respect supplied by OEM only with copper strip for power wiring inside panel.
Supply of submersible pumping plant capable of delivering 2000 lpm discharge at 65mt. head with 10% shut off head including electric motor to be operated on 415 (+\-)10% volts,3 phase,50 C\s AC at 2900 RPM nominal speed along with submersible cable supplied by the manufacturer with pump. (considering head variation)
Supply of spare pumping plant as 71.5
Supply of electrical panel with fully automatic starter suitable to be operated on 415 (+\-)10% volts,3 phase with neutral 50 C/S AC with panel suitable for above pump set along with all safety devices i.e. single phase preventer, earth fault relay, electronic over load relay, over /under voltage relay & Auto phase reversal unit complete in all respect supplied by OEM only with copper strip for power wiring inside panel.
Supply of submersible pumping plant capable of delivering 2000 lpm discharge at 85mt. head with 10% shut off head including electric motor to be operated on 415 (+\-)10% volts,3 phase,50 C\s AC at 2900 RPM nominal speed along with submersible cable supplied by the manufacturer with pump. (considering head variation)
Supply of spare pumping plant as above
Supply of electrical panel with fully automatic starter suitable to be operated on 415 (+\-)10% volts,3 phase with neutral 50 C/S AC with panel suitable for above pump set along with all safety devices i.e. single phase preventer, earth fault relay, electronic over load relay, over /under voltage relay & Auto phase reversal unit complete in all respect supplied by OEM only with copper strip for power wiring inside panel.
Supply of submersible pumping plant capable of delivering 2000 lpm discharge at 95mt. head with 10% shut off head including electric motor to be operated on 415 (+\-)10% volts,3 phase,50 C\s AC at 2900 RPM nominal speed along with submersible cable supplied by the manufacturer with pump.
Supply of spare pumping plant as above
Supply of electrical panel with fully automatic starter suitable to be operated on 415 (+\-)10% volts,3 phase with neutral 50 C/S AC with panel suitable for above pump set along with all safety devices i.e. single phase preventer, earth fault relay, electronic over load relay, over /under voltage relay & Auto phase reversal unit complete in all respect supplied by OEM only with copper strip for power wiring inside panel.
Supply of 200 amp. 3 phase with neutral FN type main switch with HRC fuses.
Supply of 125 amp. 3 phase with neutral FN type main switch with HRC fuses. (considering head variation)
Supply of 160amp. 3 phase with neutral FN type main switch with HRC fuses. (considering head variation)
Supply of 250 amp. 3 phase with neutral FN type main switch with HRC fuses. (considering head variation)
Supply of 315 amp. 3 phase with neutral FN type main switch with HRC fuses. (considering head variation)
Supply of power wiring and earthing material.
Supply of submersible copper cable 1x3x 25 sq.mm (Finolex/Havell’s make)
Supply of submersible copper cable 1x3x16 sq.mm (Finolex/Havell’s make) (considering head variation)
Supply of submersible copper cable 1x3x 35 sq.mm (Finolex/Havell’s make) (considering head variation)
Complete double loop earthing with copper plate of suitable size with earthing strips, charcoal, salt and Earthing material as per latest IS code along with funnel pipe for arrangement for watering as per IS Code- IS3043-1987.
Supply of main piping and valves of 150mm size having following items.
150 mm dia x 7.1 mm thick column pipe in 3 mt. length with interlocking arrangement 54 Mtrs. (Make: JINDAL/SWASTIK/TATA) as per IS Code- IS4270.
150mm dia CI D\f sluice valve with hand wheel - (Make: IVC/KIRLOSKER)
150mm dia CI D\F reflux valve -1 No (Make: IVC/KIRLOSKER)
150x150x150mm dia Tee-1 No
150mm dia CI D\F bend-2 Nos.
150mm dia MS D\f pipe of 2.0 Mt. length- 2 Nos
Ventury –(150x75mm ) 1 No
150mm MS DI clamp heavy duty - 1 pair
MS TW Cap (150x300 mm)-1 No
Gauges(pressure gauge up to 10kg/cm2) -1 set
150mm dia MS distance piece 1.5 mtr. long.- 1 No.
Necessary nut, bolts and packing-1 Set
Supply of 5 ton capacity and 4.5 mt. lift chain pulley block tested on 150% Load (Make: INDEF)
Supply of necessary tools and spanners. (Make: TAPARIA/EVERST) detailed as per tender document.
Supply of rubber resistance insulated sheets 2M x 1M x 25mm thick confirming to IS:15652:2006
Supply of Chlorinator Dozer pump capacity: with range upto 2 lph, 8 kg/cm2 pressure to achieve desired PPM of chlorine as per norms along with:-
Injector and NRV with PVC pipes etc. (Make: MILTON ROY)
200 Ltr. Capacity PVC tank. (Make: SINTAX)
Starter cum panel for dozing pump.
Single phase automatic stabilizer. (Make: BLUEBIRD)
Chlorine testing kit complete.
Supply of Sodium hypo-chloride (Naocl) solution. (Make: PCPL)
Installation and commissioning of pumping plant and accessories inside the pump house including dozing pump complete in each & every respect .
Testing of pumping plants as following -
At works ( as per sehedule- E & other parametter)
at Site.
Stabilization of Pumping Plant including maintenance for six month with complete O&M
Painting of entire installation with 2 coats of super enamel paint as per direction of Engineer-in- charge .
Supply & Installation of 2000 L.P.M & 70 mtr. Head Pumping Plant & Accessories at sunehra T.W No 3 & 4 (Pumping plant with great efficiency shall be offered to supply). The contractor has to give rate for given head and discharge and submit spacifications as required by the Nigam, However, In case the actual head at site changes within 10%(+ or -) either side, the contractor has to provide pump of required head and discharge at the same rate as already quoted by the firm and no extra payment will be made to the contractor for the above variation. moreover the contractor has to submit the revised spacification and design as required by the Nigam.
Supply of submersible pumping plant capable of delivering 2000 lpm discharge at 70mt. head with 10% shut off head including electric motor to be operated on 415 (+\-)10% volts,3 phase,50 C\s AC at 2900 RPM nominal speed along with submersible cable supplied by the manufacturer with pump.
Supply of spare pumping plant as above
Supply of electrical panel with fully automatic starter suitable to be operated on 415 (+\-)10% volts,3 phase with neutral 50 C/S AC with panel suitable for above pump set along with all safety devices i.e. single phase preventer, earth fault relay, electronic over load relay, over /under voltage relay & Auto phase reversal unit complete in all respect supplied by OEM only with copper strip for power wiring inside panel.
Supply & Installation of 2000 L.P.M Pumping Plant & Accessories at sunehra T.W No 3 & 4 (Pumping plant with great efficiency shall be offered to supply) additional for each head variation from 10% to 25% for each ± 10mtr head variation as detailed below :-
Supply of submersible pumping plant capable of delivering 2000 lpm discharge at 50mt. head with 10% shut off head including electric motor to be operated on 415 (+\-)10% volts,3 phase,50 C\s AC at 2900 RPM nominal speed along with submersible cable supplied by the manufacturer with pump. (considering head variation)
Supply of spare pumping plant as 71.3
Supply of electrical panel with fully automatic starter suitable to be operated on 415 (+\-)10% volts,3 phase with neutral 50 C/S AC with panel suitable for above pump set along with all safety devices i.e. single phase preventer, earth fault relay, electronic over load relay, over /under voltage relay & Auto phase reversal unit complete in all respect supplied by OEM only with copper strip for power wiring inside panel.
Supply of submersible pumping plant capable of delivering 2000 lpm discharge at 60mt. head with 10% shut off head including electric motor to be operated on 415 (+\-)10% volts,3 phase,50 C\s AC at 2900 RPM nominal speed along with submersible cable supplied by the manufacturer with pump. (considering head variation)
Supply of spare pumping plant as above
Supply of electrical panel with fully automatic starter suitable to be operated on 415 (+\-)10% volts,3 phase with neutral 50 C/S AC with panel suitable for above pump set along with all safety devices i.e. single phase preventer, earth fault relay, electronic over load relay, over /under voltage relay & Auto phase reversal unit complete in all respect supplied by OEM only with copper strip for power wiring inside panel.
Supply of submersible pumping plant capable of delivering 2000 lpm discharge at 80mt. head with 10% shut off head including electric motor to be operated on 415 (+\-)10% volts,3 phase,50 C\s AC at 2900 RPM nominal speed along with submersible cable supplied by the manufacturer with pump. (considering head variation)
Supply of spare pumping plant as above
Supply of electrical panel with fully automatic starter suitable to be operated on 415 (+\-)10% volts,3 phase with neutral 50 C/S AC with panel suitable for above pump set along with all safety devices i.e. single phase preventer, earth fault relay, electronic over load relay, over /under voltage relay & Auto phase reversal unit complete in all respect supplied by OEM only with copper strip for power wiring inside panel.
Supply of submersible pumping plant capable of delivering 2000 lpm discharge at 90mt. head with 10% shut off head including electric motor to be operated on 415 (+\-)10% volts,3 phase,50 C\s AC at 2900 RPM nominal speed along with submersible cable supplied by the manufacturer with pump.
Supply of spare pumping plant as 71.9
Supply of electrical panel with fully automatic starter suitable to be operated on 415 (+\-)10% volts,3 phase with neutral 50 C/S AC with panel suitable for above pump set along with all safety devices i.e. single phase preventer, earth fault relay, electronic over load relay, over /under voltage relay & Auto phase reversal unit complete in all respect supplied by OEM only with copper strip for power wiring inside panel. (considering head variation)
Supply of 160 amp. 3 phase with neutral FN type main switch with HRC fuses.
Supply of 100 amp. 3 phase with neutral FN type main switch with HRC fuses. (considering head variation)
Supply of 125 amp. 3 phase with neutral FN type main switch with HRC fuses. (considering head variation)
Supply of 200 amp. 3 phase with neutral FN type main switch with HRC fuses. (considering head variation)
Supply of 250 amp. 3 phase with neutral FN type main switch with HRC fuses. (considering head variation)
Supply of power wiring and earthing material.
Supply of submersible copper cable 1x3x 25 sq.mm (Finolex/Havell’s make)
Supply of submersible copper cable 1x3x16 sq.mm (Finolex/Havell’s make) (considering head variation)
Supply of submersible copper cable 1x3x 35 sq.mm (Finolex/Havell’s make) (considering head variation)
Complete double loop earthing with copper plate of suitable size with earthing strips, charcoal, salt and Earthing material as per latest IS code along with funnel pipe for arrangement for watering as per IS Code- IS3043-1987.
Supply of main piping and valves of 150mm size having following items.
150 mm dia x 7.1 mm thick column pipe in 3 mt. length with interlocking arrangement 54 Mtrs. (Make: JINDAL/SWASTIK/TATA) as per IS Code- IS4270.
150mm dia CI D\f sluice valve with hand wheel -. (Make: IVC/KIRLOSKER)
150mm dia CI D\F reflux valve (Make: IVC/KIRLOSKER)
150x150x150mm dia Tee
150mm dia CI D\F bend
150mm dia MS D\f pipe of 2.0 Mt. length
Ventury –(150x75mm )
150mm MS DI clamp heavy duty
MS TW Cap (150x300 mm)
Gauges(pressure gauge up to 10kg/cm2)
150mm dia MS distance piece 1.5 mtr. long.
Necessary nut, bolts and packing-
Supply of 5 ton capacity and 4.5 mt. lift chain pulley block tested on 150% Load (Make: INDEF)
Supply of necessary tools and spanners. (Make: TAPARIA/EVERST) detailed as per tender document.
Supply of rubber resistance insulated sheets 2M x 1M x 25mm thick confirming to IS:15652:2006
Supply of Chlorinator Dozer pump capacity: with range upto 2 lph, 8 kg/cm2 pressure to achieve desired PPM of chlorine as per norms along with:-
Injector and NRV with PVC pipes etc. (Make: MILTON ROY)
200 Ltr. Capacity PVC tank. (Make: SINTAX)
Starter cum panel for dozing pump.
Single phase automatic stabilizer. (Make: BLUEBIRD)
Chlorine testing kit complete.
Supply of Sodium hypo-chloride (Naocl) solution. (Make: PCPL)
Installation and commissioning of pumping plant and accessories inside the pump house including dozing pump complete in each & every respect .
Testing of pumping plants as following -
At works ( as per sehedule- E & other parametter)
at Site.
Stabilization of Pumping Plant including maintenance for six month with complete O&M
Painting of entire installation with 2 coats of super enamel paint as per direction of Engineer-in- charge .
Electrification of pump house at Roorkee Seven numbers tubewell under Amrut Programme.
Wiring of Light Point/fan point/exhaust fan point/call bell point with 1.5sq.mm FRLS PVC insulatied copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Group-C)
Wiring for light/power plug with 2x2.5sq.mm FRLS PVC insulated copper coductor single core cable in surface/recessed medium class PVC conduit along with1 No. 2.5 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Supplying & fixing metal suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections, etc as required.
Supplying & fixing 3 pin 5 A ceiling rose on the existing junction box/wooden block including connections etc. as required.
Supplying & fixing brass batten/angle holder including connections etc. as required.
Installation, Testing & Commissioning of pre wired florescent tube light fitting with all accessories.
S/F of 5A-32A rating Circuit Breaker
Wiring for light/power plug with 2x4 sq.mm FRLS PVC insulated copper coductor single core cable in surface/recessed medium class PVC conduit along with1 No. 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Supply of Box type 1x18 w LED tube
Supply of 8 Watt Led Bulb
S/F of 8 watt LED Bulkhead fitting
S/F Pf 45 W LED Street Light fitting complete.
SITC of Automation at Roorkee Four numbers tubewell under Amrut Programme.
GSM based Intelligent Remote Terminal Units (IRTU) with Analog and Digital parameters and features as specified to store and transmit data on GSM backbone to LMS. And also compatible to communication.
GSM Based wireless communication system capable to transfer data from remote sites control station with antenna.
Intelligent Energy Meter.
Valve actuator size 150mm.
Actuator panel
Isolation transformer
Electronic flow meter
HMI with Enabling & Development of mimics of process parameters for monitoring & control from site through HMI.
Hard wired timer
Over Voltage under Voltage
Cabling & conduiting (PVC) between Integrated RTU panel and field instruments as required for site (per tubewell)
Accessories -PVC Bend, AC & DC Relays with flexible Pipe Lugs, etc
Installation, Testing and commissioning.
Monthly Operation & maintenance of complete automation system along with all accessories of six month for each tubewell.
SITC of Servo Voltage Stabilizer at Roorkee Four numbers tubewell under Amrut Programme.
Supply, Installation, testing and commissioning of 75 KVA oil cooled copper wounded auto operated outdoor Servo Voltage Stabilizer with (carbon bush system ) with the first fill of oil at Old officers colony, Race Course, Dehradun Tubewell Under Amrut Programme with following Specifications. (i) Capacity-75 KVA (ii) Input Voltage-300-480 Volt. 3 Phase & neutral (iii) Output Voltage-415±1% volt- 3 Phase & neutral. (iv) Frequency-50 Hz including all protection devices i.e. as following. (v) Protection:- High Voltage & Low Voltage cut off & overload short circuit . (vi) Using flat carbon brushes and dimmer state unit separate control panel, Plug and play Socket connected with flexible cable up to 20 ft. for increase of fixing at accessible place suitable for unbalance input voltage and unbalance current load efficiency should be good.
Supply, Installation, testing and commissioning of 60 KVA oil cooled copper wounded auto operated outdoor Servo Voltage Stabilizer with (carbon bush system ) with the first fill of oil at Old officers colony, Race Course, Dehradun Tubewell Under Amrut Programme with following Specifications. (Considering head variation) (i) Capacity-60 KVA (ii) Input Voltage-300-480 Volt. 3 Phase & neutral (iii) Output Voltage-415±1% volt- 3 Phase & neutral. (iv) Frequency-50 Hz including all protection devices i.e. as following. (v) Protection:- High Voltage & Low Voltage cut off & overload short circuit . (vi) Using flat carbon brushes and dimmer state unit separate control panel, Plug and play Socket connected with flexible cable up to 20 ft. for increase of fixing at accessible place suitable for unbalance input voltage and unbalance current load efficiency should be good.
Supply, Installation, testing and commissioning of 100 KVA oil cooled copper wounded auto operated outdoor Servo Voltage Stabilizer with (carbon bush system ) with the first fill of oil at Old officers colony, Race Course, Dehradun Tubewell Under Amrut Programme with following Specifications. (Considering head variation) (i) Capacity-100 KVA (ii) Input Voltage-300-480 Volt. 3 Phase & neutral (iii) Output Voltage-415±1% volt- 3 Phase & neutral. (iv) Frequency-50 Hz including all protection devices i.e. as following. (v) Protection:- High Voltage & Low Voltage cut off & overload short circuit . (vi) Using flat carbon brushes and dimmer state unit separate control panel, Plug and play Socket connected with flexible cable up to 20 ft. for increase of fixing at accessible place suitable for unbalance input voltage and unbalance current load efficiency should be good.
Testing of Servo Voltage Stabilizer at work with all parameter.
Double loop earthing of above equipment including supply of 25mmx5mm thick GI earth strips, 600mmx600mmx5mm thick GI earth plates, GI Boxes, funnels, pipes, earthing chamber etc. as required as latest IE rules including digging of pits, filling of charcoal and salt in pits complete in all respect.
HARJEET SINGH CONT
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid