Loading…
Loading…
Tender Value
₹52.3 L
EMD Value
₹1.0 L
Closing Date
2 Jul 2026, 3:00 pm
S&T work in connection with 1) Construction of 2 Lane ROB in lieu of LC-6 at Km 12/2-3 on JHL-HSR section near Jamalpur Shaikhain. 2) Provision of one hook placement of half Goods rake at Goods siding at Bassi Pathana (BSPN) station of Ambala division. 3) Construction of 2 Nos LHS(5mx5m) by pushing in lieu of C-18 at Km 29/1-2 &LC -59 at Km 77/15-78/0 on JHL-HSR section. 4) Replacement of Girder with PSC slab & strengthening of substructure of Br.No.190, 197A-1, 220A, 232 DUI-JHL, Br.No.49, JHL-HSR, 30,82,135 LDH-DUI, Br.No 60-A, 100 RPJ-DUI, 221,292 DUI-BTI & 143 BTI-SGNR Section. 5) Provision of 3m FOB at Barwala (BXC)
OT-11-2026-27
OT-11-2026-27
Open
180 Days
Ambala, Haryana
₹0
₹1.0 L
5 Jun 2026
5 Jun 2026
18 Jun 2026
"Modification/Alteration/augmentation of existing Ansaldo electronic interlocking (EI) system at JPS Station as per RDSO specn No. RDSO/SPN/192/2005 or latest as per approved 01 Signaling Plans and Selection Table/Locking Table of stations (for phased doubling. LC removal etc.), technical specifications & special conditions of contract.This includes supplies necessary for alteration/modification in VDU's software. Item includes preparation of Selection Table, Locking Table Control Panel and Route Section Plan, Wiring Diagram and other diagrams (other technical documents if any) based on Signalling Plan supplied by Railways.Submission of final completion as made documents.Insp-RDSO For supply portion and consignee for execution portion" Above/
Supply of single app. Case steel RE with 'E' type lock and key ward no. 42 and handle as per Drg. No. sketch no. RE/S&T/ALD/SK/219/82 and 221/82 with Alt. A & 221/82 with Alt. B.Inspection: By Consignee
Supply of Digital insulation Tester (Megger) 500 V, Motwani, Philips make or similar or better. Inspection: By Consignee
Supply of apparatus Case steel RE half with 'E' type locks and key ward no. 42 and handle as per Drg. No. sketch no. RE/S&T/ALD/SK/220/82 and 221/82 with Alt. A & 221/82 with Alt. B.Inspection: By Consignee
Supply of Digital AC/DC low current Clampmeter model KOICO 3540 or similar or better. Inspection by Consignee.
Supply of Multi meter fluke 179 TRUE RMS Multimeter or Similar or better suitable for measuring various parameter.Inspection: By Consignee
Supply & testing of digital earth resistance tester modelno. MOTWANE DET20, .1/01ohm resolution range 0-20 ohms or similar. Inspection by Consignee.
Supply of FRP type TLJB as per drg. No. SA-20101/M made of FRP material (FRP materail conforming to RDSO/SPN/151/97 or latest) complete with 450 mm long 25 mm dia pipe.Inspection: By Consignee
Supply of Electric fuse complete with fuse block (Base) for Railway signalling Non- 08 deteriorating type low voltage fuse assembly 2Amp/4Amp/16 Amp. To suit RDSO spec no.IRS:S- 78/2006 or latest and fuse block made of PBT/Polycarbonate as per IRS:S-75/2006 Revision 2 or latest and Drawing No.23748(Alt-4) or latest. Fuse block shall be suitable for rounded head type fuses.Insp-RDSO
Supply of KLCR type TMA 24 V DC with 2F/2B contacts configuration with different wards combination (TMA 1122/116 OLO), as per spec. IRS:S-23, IRS:S-34 &IRS:S-46. Details of wards combination will be provided during execution of work.-Insp-RDSO
Supply of terminal block 25mm center M-6 (ARA terminals) as per IRS spec. No.IRS-S- 75/2006 (Rev.2) & IRS drawing No. SA-23741A(Alt.4), SA-23745(Alt.5), SA-23746 & SA-23756(Alt.3). Inspection By:RDSO Above/
Supply, testing and laying of 2nd class well burnt 'B' class bricks in trench breadthwise over the top of cable throught i.e. 8 bricks in one meter over whole of the cables. Bricks shall be got staked and got inspected by Rly. Representative before laying. Inspection: By Consignee
Supply and installation of earth electrodes as per std. practice. The item includes digging of pit in earth, 3 Mtrs. deep and fixing earth electrode pipe. Casting of cement concrete enclosures as per drg. No. (NR/S&T/CON/6.4/97). The soil treatement shall be done as per std. pratice. The item includes provn. of mild steel flat of size 35mm x 6mm (as per IRSEM) and nut 02 bolted connection of MS flat with earth electrode. The other end of mild steel flat to be connected to block instrument, cable sheath of power equipment, signal base, apparatus case, CT rack / relay racks, other equipments as per the instruction of Engr. at site & IRSEM. Earhting connection location to location shall be done through cable which shall be provided by Railway. Complete materials such as earth electrodes as per drg. No. (NR/S&T/CON/6.3/97), cement, wiring material, nut bolt for connection & mild steel flat of size 35mm x 6mm or 210 sqm as per SEM etc. to be supplied by the contractor.Inspection: By Consignee
Supply and fixing of GI pipe 75mm dia, 3 mm thick ,as per specn No.IS-1239, Medium grade, perforated of required length at culverts/bridges/along the cutting, suitably concreted at both ends.G.I clamps of M.S flats bolts & nuts to be supplied by the contractor.Inspection: By Consignee
Supply and installation of optical fiber cable joint enclosure as per TEC spec 04 No.GR/OJC-02/01/March 99 with latest amendment and splicing of optical fiber cables(24 Fibers and testing), . This includes provision of joint pit (RCC/Prefabricated) as per instructions of Railway Engineer's Representative at site. Inspection by-Consignee
Supply and fixing of cable route marker as per RST/C/203 of FRP.Insp-Consignee
Supply & provison of straight through joints thermo shrink jointing kit with the help of 06 thermo shrink jointing kit as per specifications, drawings and stipulations of tender documents and as per approved cable route plan at various locations for 06Quad/04 Quad cable. Jointing kits to be supplied as per RDSO specification IRS:TC 77-2012 (Rev.-3) or latest amendments. Inspection by Consignee for supply portion.Inspection: By Consignee Above/
Excavating and refilling of trench in Normal Soil to the level of ground with rammed 01 earth as per drg. No.(NR/S&T/CON/1.1/97-A) so as not to form a drain 0.3 Mtrs. Wide & 1Mtr. Deep on both side of the station alongside the track. It shall conform to the safe distance as per signalling and cable route plan in all type of soil, It also includes clearance of routes of trees & bushes. Lesser depth due to site condition shall be paid proportionately.Inspection: By Consignee
Boring & Trenchless cabling along with supply and insertion of HDPE pipe of PE 80 PN 02 8 grade of 90mm dia with min. 6.7mm and max. 7.6mm wall thickness as per IS 4984:2016 in the bore for the laying of signalling/ Telecom/ Power cables under the track/ road.( cable lying is covered separately). HDPE pipe is to be supplied by the contractor. Inspection by Consignee.
All work of horizontal boring and trenchless cabling along with supply, transpotation and insertion of double wall corrugated pipe -(ISI marked) conforming to RDSO Spec no. 03 RDSO/SPN/204/2011 or latest, and the laying of cable in the boring under the track / road etc as per instruction of site engg. by using pipe of size 120mm outer dia, 103.5 mm inner dia in which required number of cables to be crossed. The depth of horizontal boring should be minimum 1.0 mtr. from rail flange/road level.Insp-Consignee
Laying of signalling/Telecom/power cables of different sizes as per approved Drg. No. NR/S&T/CON/1-1/97C and as per cable route plan approved by Railways and meggering of cable before and after its laying of all type of outdoor cables.Inspection: By Consignee
Casting, concreting and curing of foundation and erection of single apparatus cases of size (1160mmX760mm at surface and 650 mm deep as per approved drawing no. 05 NR/S&T/Con./2.7/97. A layer of 3mm of Bitumin compound has to be provided between foundation and location box to prevent ingress of water in the base of location box. All material such as cement, coarse, sand, aggregate & anchor bolts shall be supplied by the contractor. Appartus case single will be supplied by railway. Contractor is required to execute all type of repair works of foundation if required during inserting the cable for termination.Inspection: By Consignee
Preparation of App. Case single not involving wiring of relays: Preparation & fixing of bakelite hylum sheet 910x800x6mm and Backelite shelf 900x450x25mm duly fixed by angle iron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location boxes secured by nuts and bolts.This includes fixing of fuses, ARA terminal, fixing and jamming of cables with 2 inch thick salwood plank provided at the bottom. This will include opening, pasting and jamming armour of each cable in the 06 hole drilled separately for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering.Wiring description for terminal drawing of circuits, inside app. Case. Painting from out side as well inside with red oxide and aluminum paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials including Backelite shelf, hylum board, salwood plank, wire and wiring material, non deteriorating type HRC fuses with bases, catenary wires, nuts and bolts and other items shall be supplied by the contractor and shall be as per the RDSO specn.(as applicable). ARA terminals only shall be supplied by the Railways.Inspection: By Consignee
Preparation of App. Case single involving wiring of relays: Preparation & fixing of bakelite hylum sheet 910x800x6mm and bakelite shelf 900x450x25mm duly fixed by angle iron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location boxes secured by nuts and bolts. This includes fixing of fuses, ARA terminal, Q series relays and other type relays on square bars fixing and jamming of cables with 2 inch thick salwood plank provided at the bottom. This will include opening, pasting and jamming armour of each cable in the hole drilled separately for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering. Wiring description for terminal drawing of circuits, inside app. Case. Painting from out side as well inside with red oxide and aluminum paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials including Bakelite shelf, hylum board, salwood plank, wire and wiring material, non deteriorating type HRC fuses with bases, catenary wires, nuts and bolts and other items shall be supplied by the contractor and shall be as per the RDSO specn.(as applicable). Relays, ARA terminals only shall be supplied by the Railways.
Casting, concreting and curing of foundation and erection of half app.cases of size (670mmx760mm) and 650mm deep as per Drg.No.NR/S&T/CON/2.8/97. A layer of 3 mm of bitumen 08 compound has to be provided between foundation and location box to prevent ingress of water in the base of location box. All material such as cement,coarse,sand, aggregate and anchor bolt shall be supplied by contractor. App. Case half will be supplied by Railway. Contractor is required to execute all type of repair Works of foundations if required during inserting the cable for termination.Inspection: By Consignee
Transportation of signaling /Telecom materials by road from various stores of SSE/Sig 09 & SSE/tele of UMB division or GZB depot, SSB depot, JUDW depo etc. as per the instructions of the railway representative at the site. The work also includes loading, unloading and stacking of the materials.Inspection: By Consignee
Concreting unscheduled items in concrete of 1:3:6 ratio in cement, coarse sand and aggregate 25mm at different places in the yard and plastering top in fine plaster of 1:4 cement sand 10 ratio. It also includes the excavation of earth as required at site and as per instruction of site in charge. The volume in cubic meters shall include the volume occupied by any CI foundation, trestle, MS angle or flat or GI pipe required to be embedded in the casting. Cement coarse sand and aggregate 25mm are to be supplied by the contractor..Inspection: By Consignee
Earth work for excavation and refilling around location boxes and signals etc. where 11 necessary including 50M lead and 1.5M lift. The lead is to be measured from centre of gravity of location to the centre of filling and lift from main ground level. The earth work should be well rammed including breaking of clods, leveling and dressing etc. as per instruction of Engineer at site.Inspection: By Consignee
Testing & meggering of all types of outdoor cables after its laying and termination on 12 both ends under supervision of Railway representative. This also includes preparation of test report for core to core and core to earth on prescribed proforma for each core of the cable separately after termination of cable. This also includes dressing & lacing of cable on both ends. Performa for testing & material for lacing to be supplied by the contractor..Inspection: By Consignee
Installation of KLCR & its box in location boxes, supply & installtion heavy duty push 13 button, LED indicator on MS sheet of 4.5 mm thick inside location box for crank handle locking. The work includes fixing & wiring of magneto telephones, wiring of relays, push buttons and termination of tail cable as per instruction of site engineer. All material except KLCR & its box and magneto telephone to be supplied by the contractor..Inspection: By Consignee
"Dismantling of lifting barrier/ gate leaves complete set along with winch, wire rope, 14 boom locking arrangements. All dismantled material to be transported and stacked in the store of Dy CMM/JUDW store depot or SSE/Sig/Store or any other store of northern railway as per consignee. Note :- Before dismantling joint survey is to be done with the site engr. and report to be submitted to the site engr.(1 Job= 1 LC)..Inspection: By Consignee"
Dismantling and releasing of location boxes which includes all S&T fittings of electrical and mechanical, releasing of termination boards, relays, terminals, batteriies, track feed chargers and other associated fittings installed therein complete with fittings. All dismantelled matterial to be transported and stack in the store of SSE/Sig or DY.CMM/JUDW store depot at JUDW/site supervisor or any other store of northern railway. As per consignee Note :- Before dismantling joint survey is to be done with the site engineer and report to be submitted to the site engr. (1 Job= 1 Location Box)..Inspection: By Consignee
Supply of HDPE duct 40/33 mm as per RDSO/SPN/TC/45/2013 Rev.2.0 with latest 16 amendments as available. For each KM of HDPE DUCT following items are to be supplied a) End plugs-2no b) Cable sealing plugs-2 no. © Plastic couples slip fit/push fit b type-2 no d) End plugs to be provided along with drum-2 nos.Inspection By consignee
Laying of HDPE duct as per approved cable route plan in the exavated trenches/other protected work/RCC channel etc. including all accessories like end caps, collars, bends, couplers etc. 17 The ends of the duct to be sealed with end plugs till OFC blowing is done. Important: The layingof OFC cable indepedently or along with Quad cable/PIJF cable in same trench shall be governed by the RDSO drawings No.RDSO/TCDO/ COP-6 (a) and RDSO/TCDO/COP-8 (a) respectively issued vide Chapter XIII of The Telecom Manual. Inspection By-Consignee
Blowing of OFC Cable in HDPE duct by mechanical system as per instruction of Railway engineer's representative at site. Inspection by-Consignee
Wiring of relays in relay room/relay huts as per approved wiring diagrams. All material such as relay fitting strips, screws, nut bolts for fixing of relays angle iron for support, small 19 piece of ladder for wire supporting, good quality solder wire, lacing matetrial etc. except cables/wires to be supplied by contractor. (Supply of cables & wires covered sepately). It also includes soldering, dressing, bunching, lacing, fixing of relay basis etc. and provision of LED indication , vital relays in relay room as per instruction of site Engineer..Inspection: By Consignee
"Installation of Berthing and straight DC track circuits to suit RE area as per std. Practice. This will include following as per site requirement :- (a) Drilling of holes 7.2 mm dia or size as required provision of continuous G.I. wire bonding on switch portion and crossing of pointwith two bonds wires and two clipsduly fastended with fish plates and bolts at each joints including transverse bonding with rope wire. 8SWG G.I. soft bond wire, Channel bond pins and all other material required will be supplied by contractor. (b) Jumpering from rail to rail or to track lead junction box including polarity jumpers/cables as per track jumpering/ insulation diagram. This includes continuity of joint on rail web for TLJB/BOOT LEG bonding method, terminating the jumpers in the TL JB and fixing the jumper on the sleeper as per instructions of Engr. at site. (c) Fixing of insulated block joints complete with provision of skimmed fish plate. Fish plates shall be supplied by the Railways but skimming to 20 be done by contractor. Supply of insulation materials for insulated block joints is not included. (d) Fixing of TL JBs asper drg. No.(NR/S&T/CON/3.2/97A) along with concrete foundation and plastering on both ends i.e. T.F. and TR end and for polarity changers as per the track jumpering/ insulation diagram. All material for fixing including angle iron shall be suppliedby the contractor. This also includes supply and fixing of TLJBs with provision of M-6 terminals. TLJB to be written with track circuit number. (e) Prov. and wiring in the app.Cases/relay huts of T.F. batterycharger, TF resistance 15/30 Ohms, track relays, choke B type (at Feed End & Relay End) & batteries as per the standard practice using fuses and terminals. This includes supply of all material by contractor as per RDSO specifications (as applicable) except supply of TF battery charger, batteries, relays which are covered separately. (f) Commissioning of track circuits as per provisions of Paras of IRS spec. S- 36/87,Amd.2. This includes adjustment of track feed resistance, testing with train shunt resistance. This also includes preparation of track history cards. Track history card should be supplied by the contractor..Inspection: By Consignee"
"Installation of Point track circuit having single point(excluding traps) DC track circuits to suit RE area asper std. Practice. This will include following as persite requirement:- (a) Drilling of holes 7.2 mm diaor size as required provision of continuous G.I. wire bonding on switch portion and crossing of point with two bonds wires and two clips duly fastended withfish plates and bolts at each joints including transverse bonding with rope wire. 8 SWG G.I. soft bond wire, Channel bond pins and all other material required will be supplied by contractor. (b) Jumpering from rail to rail or to track lead junction box including polarity jumpers/cables as per trackjumpering/ insulation diagram. This includes continuity of joint on rail web for TLJB/BOOT LEG bonding method, terminating the jumpers in the TLJB and fixing the jumper on the sleeper as per instructions of Engr. at site. (c) Fixing of insulated block joints complete with provision of skimmed fishplate. Fish plates shall be supplied by the Railways but skimming to be done by contractor. Supply of insulation materials for insulated block joints is not included. (d) Fixing of TL JBs as per drg. No. (NR/S&T/CON/3.2/97A) along with concrete foundation and plastering on both ends i.e. T.F. and TR end and for polarity changers as per the track jumpering/ insulation diagram. All material for fixing including angle iron shall be supplied by the contractor. This also includes supply and fixing of TLJBs with provision of M-6 terminals. TLJB to be written with track circuit number. (e) Prov. and wiring in the app. Cases/relay huts of T.F. battery charger, TF resistance 15/30 Ohms, track relays, choke B type (at Feed End & Relay End) & batteries as per the standard practice using fuses and terminals.This all include supply of all material by contractor except supply of TF battery charger, batteries, relays which are covered separately. (f) Commissioning of track circuits as per prov.of para of IRS specn. S-36/87 Amd 2. This includes adjustment of track feed resistance, testing with train shunt resistance. This also includes preparation of track history cards.Track history card should be supplied by the contractor. Inspection : B type Choke and Resistance by RDSO.Execution- Consignee"
Cleaning, Scrapping, Painting and lettering of all newly installed and existing gears such as signals, point equipment, track circuit equipment with T.C. no. on rail app. Cases JB. TL JBs point rodding cranks, compensators etc. including gate equipment if existing in station section as 22 per the provision of IRSEM. All paints (ISI marked) shall be approved by Railway Engr. and painting material to be supplied by the contractor. This item also includes writing and painting requirement of all indoor and outdoor gears along with making of all circuit nos. near terminal and terminal boards/track in app. Cases, junction boxes, relay room, SMs room, writing of relay nomenclature fuse nos. and equipment nomenclature as the approved plans and as per provision of IRSEM. Inspection: By Consignee
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
SIPJAMALPURSHAIKHANANSALDOEI.pdf
ATTACHMENT
SIPBASSIPATHANA.pdf
ATTACHMENT
Generalcondition5Estimatebassipathana1.pdf
ATTACHMENT
JPOforProtectionofcablesduringexecutionofvariousworks_2023.pdf JPO 2023
ATTACHMENT
STD-2022withAmndt1-11.pdf
ATTACHMENT
JPOforProtectionofcablesduringexecutionofvariousworks_2023.pdf
ATTACHMENT
Download all tender documents and submit your bid