Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance 20 21 ETA HOUSE RAZAK GARDEN MAIN ROAD RAZAK GARDEN MAIN ROAD CHENNAI TAMIL NADU 600106 | CHENNAI | TAMIL NADU | 600106 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance 107 2 AMPA MANOR IST FLOOR NELSON MANICKAM ROAD AMINJIKARAI CHENNAI 0 600 029 NO 107 2 AMPA MANOR 1ST FLOOR NELSON MANICKAM ROAD AMINIJIKARAI AMINJIKARAI | Admitted-Fee/PreQual/Technical/Finance |
| 5 | Not Admitted-Fee/PreQual/Technical/Finance | Not Admitted-Fee/PreQual/Technical/Finance Others-EMD as per NIT clause12.2a Not submitted |
Tender Value
₹40.6 L
EMD Value
₹81,200
Closing Date
24 Jul 2023, 2:00 pmClosed
Dy Chief Engineer
Electrical projects 2 nd floor Dy Chief Engineer (PD EP V AC)Sarathi Building Nuclear Fuel Complex Hyderabad
Providing of AC Rooftop Type Package AC along with GI ducting thermal acoustic insulation supporting structural steel work power control cabling supply return air grills earthing etc for Central Control Room Control Panel Room CFFP
2023_NFC_760988_1
E/650
Open Tender
Electrical Works
Works
270 days
Hyderabad
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹81,200
Yes
25 Jul 2023
10 Jul 2023
25 Jul 2023
10 Jul 2023
24 Jul 2023
10 Jul 2023
10 Jul 2023 - 15 Jul 2023
Amount
8 TR Capacity Rooftop Package AC with 2800CFM capacity . Power Supply : 3 phase,415 volts, 50 Hz ; Number of compressors : 01 (one); Condenser : Air Cooled ; Weather proof electro galvanised mild steel casing is coated with an epoxy polyster powder coating for protection against corrosion. Rooftop AC design DX cooling coil with Static pressure : 100 Pa. Complete details in detailed tender speicficaitons.
Supply
Erection
16 TR Capacity Rooftop Package AC with 7000CFM capacity . Power Supply : 3 phase,415 volts, 50 Hz ; Number of compressors : 02 (Two); Condenser : Air Cooled ; Weather proof electro galvanised mild steel casing is coated with an epoxy polyster powder coating for protection against corrosion. Rooftop AC design DX cooling coil with Static pressure : 150 Pa. Complete details in detailed tender speicficaitons.
Supply
Erection
GI ducting along with suitable supporting MS angle structure based on the approved drawings as per site conditions
Supply: GI ducting 22 Gauge
Erection: GI ducting 22 Gauge
Supply: GI ducting 24 Gauge
Erection: GI ducting 24 Gauge
THERMAL INSULATION OF DUCTS ( EXPOSED ): Supply and Application of External Thermal Insulation of Supply Air and return air ducting coming out side. Material of construction shall be cross linked polyolefin/polyethylene foam material with closed cell structure and with factory applied reinforced aluminium foil. The density of the same shall be within 25 Kg/m3.The material should have a thermal conductivity not exceeding 0.032 W/mK. The insulation material shall be shall be stuck to the cleaned duct surface by factory pre-fixed cold adhesive. The finishing will be carried out with fixing 200 gsm glass cloth with the help of adhesive Fevicol lag coating (AF 5590) . Finally it will be painted with synthetic enamel paint. The material and installation methodology should be in accordance with the specifications. Insulation shall be of 25 mm thick with 200 GSM glass cloth finishing.
Supply
Erection
THERMAL INSULATION OF DUCTS (UN EXPOSED) : Supply and Application of External Thermal Insulation of Supply Air ducting. Material of construction shall be cross linked polyolefin/ polyethelene foam material with closed cell structure and with factory applied reinforced aluminium foil. The density of the same shall be within 25 Kg/m3. The material should have a thermal conductivity not exceeding 0.032 W/mK. The insulation material shall be shall be stuck to the cleaned duct surface by factory pre-fixed cold adhesive. The material and installation methodology should be in accordance with the specifications. Thickness of insulation:25mm.
Supply
Erection
ACOUSTIC INSULATION OF DUCTS : Supply and Application of Acoustic insulation for the initial portion of supply air ducting. Material of construction shall be fibre-free elastomeric nitrile rubber foam with open cell structure . The density of the same shall be within 140-180 Kg/m3. The material should have a thermal conductivity not exceeding 0.050 W/mK. The maximum surface temperature the material should withstand is 105° C and minimum temperature should be -20°C. The material should conform to Class 1 rating for surface spread of Flame as per BS 476 Part 7. The insulation material shall be shall be stuck to the cleaned duct surface by factory pre-fixed cold adhesive. The material and installation methodology should be in accordance with the specifications. Thickness of insulation:25mm.
Supply
Erection
Under deck insulation of exposed roof with 50mm thick EPS, 18 kg density TF quality.
Supply
Erection
POWER CABLING : Power supply cable ( Armoured , FRLS- Cable & Four Core -Copper ) from MCBDB to Rooftop Package AC with GI wire for double earthing.
Supply : 10 Sq.mm for 8 TR Capacity Rooftop Package AC
Erection : 10 Sq.mm for 8 TR Capacity Rooftop Package AC
Supply : 16 Sq.mm for 8 TR Capacity Rooftop Package AC
Erection : 16 Sq.mm for 8 TR Capacity Rooftop Package AC
Communication cable from 8 TR & 16 TR Rooftop Package AC to Remote control unit locations (in the control rooms). Cable shall be run in suitable PVC pipe with necessary fittings,etc. Remotes shall be fixed in a suitable CPVC box with required materials
Supply
Erection
GI Earth strip of 3mm thick one inch flat
Supply
Erection
Aluminum SA grills : Supply & Installation of Aluminium powder coated ( of minimum thickness of 0.8mm )grill with Valume Control dampers for Supply Air.
Supply
Erection
Aluminum RA grills : Supply & Installation of Aluminium powder coated ( of minimum thickness of 0.8mm ) grill without Volume Control dampers for Return Air.
Supply
Erection
DAMPERS: Supply, installation, testing and commissioning of Factory fabricated low leakage volume control/duct dampers of Aerofoil-blade Aluminium dampers.
Supply
Erection
STRUCTURAL FABRICATED STEEL WORK: Supply, Fabrication , Cutting, Welding , Erection at site and painting of M. S. Angle structural steel work for required truss, AC /Supporting structurer/etc. & as per site requirements, etc. based on the approved drawings. The work should be carried out as per good manufacturing and installation practices in concurrence with approved drawings. The structural steel materials should confirm to IS : 2062 (latest version) as per drawings. All welding electrodes to confirm to relevant IS codes. Fabrication and erection of the structural steel works shall be as per IS: 800 and welding work as per IS:816 and IS: 822. Finally all steel work to be painted with one coat of zinc chromate primer and two coats of metal primer paint.
Supply
Erection
GI Cable Tray perforated ladder type of required sizes as per the site conditions
Supply
Erection
Condensate water drain piping : CPVC drain piping with insulated out of class O closed cell elastomeric nitrile rubber material with U trap., bends, clamping, etc.
Supply
Erection
Electrical power supply panel (MCBDB) board for 8 TR Rooftop Package AC Unit - One suitable size incommer- isolator and 3 outgoing (02W+01SB) MCB's.(as recommended by OEM). Indication lamps for Power supply, AC - ON & OFF and Voltage & Current measuring meter (mutli function meter) as per IS code. Complete details in detailed tender speicficaitons.
Supply
Erection
Electrical power supply panel (MCBDB) board for 16 TR Rooftop Package AC Unit - One suitable size incommer- isolator and 3 outgoing (02W+01SB) MCB's. Indication lamps for Power supply, AC - ON & OFF and Voltage & Current measuring meter (mutli function meter) as per IS code.Complete details in detailed tender speicficaitons.
Supply
Erection
Removal of existing GI ducting & closing the openings with suitable GI duct with necessary fittings, etc. and safe disposal at Stores with necessary transporatation.
Supply
Erection
ETA Engineering Pvt Ltd
Fresh Air Tecnologies
INTEGREATED COOLTECH PVT LTD
stage.html
html • 0.02 MB
finance_800039.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .