Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance HOUSE NO 43 SILCHAR HOUSE NO 43 VIVEKANANDA ROAD LANE NO 28 VILLAGE TOWN SILCHAR CITY SILCHAR CACHAR ASSAM 788007 INDIA | CACHAR | ASSAM | 788007 | Admitted-Finance |
| 2 | Rejected-Technical S M C ROAD GHUNGOOR SILCHAR DIST CACHAR ASSAM PIN 788014 | SILCHAR | CACHAR | ASSAM | 788014 | Rejected-Technical Technically disqualified |
Tender Value
₹28.0 L
EMD Value
₹56,035
Closing Date
18 Dec 2024, 11:00 amClosed
EXECUTIVE ENGINEER
ENGINEERING SECTION, ASSAM UNIVERSITY SILCHAR
SITC of 11/0.4KV 500 KVA DTR Copper Wound - BIS Level - 2 at SOT Complex, AUS.
2024_AUS_839307_1
Au/Engg/maint/Elect-121/2024
Open Tender
Electrical Works
Works
60 days
ASSAM UNIVERSITY SILCHAR
Please refer Tender documents.
3 documents required · 3 mandatory
₹2,500
Assam University Silchar
₹56,035
24 Dec 2024
12 Dec 2024
19 Dec 2024
12 Dec 2024
18 Dec 2024
12 Dec 2024
Amount
1C X120sqmm unarmoured 1.1 KV grade Al cable
DTR cubical for 500 kVA DTRs comprising of requisite one no µP based MCCB/ACB for incomming and three TM relaese MCCB/FN for outgoing , Static TVM , CT Vmeter, Ameter, LED pilot lamp indicator complete with busbar etc.
GI earthing pipe 50mm dia 3m length ,3.15 mm thickness with perforated holes of 15 mm dia at 30 cm interval along the pipe
Supply, installation & testing of G.I. Plate earth station with 600 mmx600 mmx6 mm heavy duty G.I. earth plate with necessary 40 mm dia. G.I. watering pipe with G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement with 300 mmx300 mmx6 mm hinged cover C.I. cover plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt .
GI trip 25X3mm for DRT earthing
GI trip 50X6 mm for DRT neutral earthing
11/0.4KV 500 KVA DTR
Supply and installation 11/0.4KV 500 KVA DTR Copper Wound - BIS Level - 2
Testing and commissioning of 11/0.4KV 500 KVA DTR Copper Wound - BIS Level – 2 with necessary statutory approval and inspection complete as directed.
GI Steel Tubular Pole SP-60 (12.00)
ll KV DO Fuse Set 200A Assembly
11 KV 400A GOAB switch cum horn type fuse set
Disc insulator (Poly) 70 KN (T&C)
Pin insulator poly 5 KN
LT pin insulator
LT Guy insulator
LT shackel insulator
GI 11 KV T Cross arm with angle size 50X50X6 mm
GI channel cross arm (100X50X6X2200)mm
GI channel cross arm (100X50X6X2800)mm
GI channel cross arm (100X50X6X3200)mm
LT angle cross arm (40X40X6X500)mm
11Kv 5KA LA (Line type Distribution class)
Transformer oil EHV grade insulating oil
H/W fitting for disc insulator T&C 70kN tension type
LT GI Shackel strap with bolts
DTR fencing as per REC standards specification complete with labour and meterials.
Earth filling with river sand including watering leveling compacting grading etc including payment for forest royalty and other duties as per site condition and technical specification.
Grouting and muflerring of steel tubular pole as per specification and drawing with minimum planting deapth of 2.15 mtr
Grouting and muflerring of 8.5 mtr pole as per specification and drawing with minimum planting deapth of 1.5 mtr
Grouting of stay set with PCC and boulder
DTR fencing including all meterial complete with RCC footing beam ,brick wall etc as per specification Rates include all meterial and labour.
Transformer pad for 500 KVA distribution transformer complete
Testing of transformer
Supplying and erection of L.T. stay set complete (Galvanize with 19mm dia x1.8m long stay rod anchor plate of size 30cm x 30cm x 6.4 mm thimble stay clamps tube buckle (19mmx 60c 7/14 SWG dia G.I stay and strain insulation etc. in cement concrete 1:3:6:(1Cement:3Course sand:6graded stone aggregate 40mm nominal size foundation including excavation and refilling etc. as required and as directed by the department.
Supplying and erection of H.T. stay set complete (Galvanize with 19mm dia x1.8m long stay rod anchor plate of size 30cm x 30cm x6.4 mm thimble stay clamps tube buckle (19mmx 60c 7/3.15 mm dia G.I stay and strain insulation etc. in cement concrete 1:3:6:(1Cement:3Course sand:6graded stone aggregate 40mm nominal size foundation including excavation and refilling etc. as required and as directed by the department.
Supplying and string up of 3 Ph , 3 Wire AAAC Racoon conductor in the existing P.S.C./ M.S/ Galvanized pole with binding etc. as required and as directed by the department. Directed by the department.
Testing and commissioning of 3 Ph , 3 Wire AAAC Racoon conductor HV power line with necessary statutory approval and inspection as directed by the department.
Any other SOR item based on APDCL / CPWD SOR
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .