Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.2 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹13.6 L+₹11.5 L (525.9%)Admitted-Finance 3 18 HIG BAHADURPUR HOUSING COLONY PATNA BIHAR 800026 | PATNA | BIHAR | 800026 | L2 | Admitted-Finance | |
| 3 | L3₹53.3 L+₹51.1 L (2348.5%)Admitted-Finance | L3 | Admitted-Finance | |
| 4 | L4₹54.3 L+₹52.2 L (2395.7%)Admitted-Finance | L4 | Admitted-Finance | |
| 5 | Rejected-Technical B 7 10 SAFDARJUNG ENCLAVE GREEN PARK SAFDARJUNG ENCLAVE SAFDARJUNG ENCLAVE SOUTH WEST DELHI DELHI 110029 | SOUTH DELHI | DELHI | 110029 | - | Rejected-Technical Commercially |
| Sl No | Description | Qty | Unit | Apex India L3 | EL MED IMAGING L4 | INDIRA SURGICALS L1 | ASAP IMPACT PVT LTD L2 |
|---|---|---|---|---|---|---|---|
| 1.00Laying and Jointing PVC Pipe. Heading | |||||||
| 1.10 | Pure Tone Audiometer (Digital)
Test available:
Air Conduction: Frequency Range – 125 - 8000Hz
Intensities - -10 to 120dB
Bone Conduction: Frequency Range – 250 - 8000Hz
Intensities - -10 to 80dB
Special Tests - Stenger test, Free Field ,SISI ABLB.
Tone - Continuous Tone , Pulse Tone , Warble Tone
Maximum
Hearing Level - Air – 10dB to 120 d B HL,(for SPL add 25.5 dB at 250 Hz) , Bone -10dB to + 80 dB HL, Speech -10dB to + 100dB HL , Masking – 10dB to + 100dB HL.
Attenuator - Click free , 5 dB
Masking - Narrow Band Masking.
Presentation - Normal or Inverse mode for all signals
External inputs- Tape recorder, CD Player or Microphone
Accuracy of
Frequency - Better than 1%
Microprocessor controlled ,
SISI (Auto Calculation of Scores),
PC Interface for on line Communication ,
Data storage facilities option Unlimited With PC,
Software for patients with data base ,
Free Field Speakers with inbuilt amplifier,
Audiometer must be European CE/ USFDA accredited. | 1 | Nos | 5,42,000 ₹5,42,000 | 4,98,000 ₹4,98,000 Lowest | - | - |
| 2.00 | Impedance Audiometer (Digital)
with High Frequency Probe Tone
Special key Features:Fast, accurate impedance measurements
Intuitive use Ipsilateral and contralateral reflex tests
Portable Large graphics display Tympanometry measurements:
Probe tone level accuracy: 226Hz +/-2%; 85d BSPL +/-2dB 1000 Hz +/-2%; 79d BSPL +/-2dB
Over ear canal volume range Pressure range and accuracy: +200daPa to -400daPa +/-10daPa or +/-10% (whichever is larger) over range 0.1 to5ml Direction of sweep: Positive to negative pressure Volumetric range and accuracy: 226Hz:0.2ml to 5ml; 1000Hz: 0.1ml to 5ml
+/-0.1ml or +/-5% (whichever is larger) Analysis performed : Admittance peak level in ml (226Hz) Or m Ώ (1000Hz) & pressure at peak; Gradient in daPa (for 226Hz) Ear Canal Volume (ECV) Measurement sweep speeds : Selectable: 100, 200 or 300 daPa/sec.Reflex measurements : Reflex type: Ipsilateral, contralateral or bothReflex frequencies: Ipsilateral, and contralateral: User-configurable. Selectable form: 500Hz, 1kHz & 4kHz (+/-2%) Reflex detection threshold: 0.01ml to 0.5ml +/-0.01ml (configurable in 0.01ml steps). Thermal Printer to be included
Analysis performed: Reflex maximum amplitude an pass/fail at each test level
Power: Mains: 100-240Vac; 50/60Hz
Standards Impedance: IEC 60645-5 Type 2 tympanometer ANSI S3.39 Type 2 tympanometer Complies to Medical Device directive.
Must be European CE/ USFDA accredited. | 1 | Nos | 5,68,000 ₹5,68,000 Lowest | 6,35,000 ₹6,35,000 | - | - |
| 3.00 | BERA
Brainstem Evoked Response Audiometer with ASSR, OAE & CE-Chirp
Special Key Features of BERA:
Fmp – Incorporating multiple points of the recorded waveform, Bayesian weighting
(more significant to responses received with less noise), CE – CHIRP, Early latency tests, pre-loaded protocol, Digital filter : Assist you to identify the clear peak , highly reliable , accurate and fast results.
FEATURES:
2 channels , windows based , stimulus level 0 – 100 dB nHL, wave form storage.
Preamplifier:
Frequency Response 0.5 – 500Hz, Noise 4.0 nV Hz , CMR Ratio > 118 dB,
Stimulus:
Stimulus Rate : 0.1 to 80.1 stimuli per seconds in steps of 0.1, Envelopes / Windows : Bartlett, Blackman , Gaussain, Hanning, Hamming , Rectangle and manual , Masking : White noise.
Filter:
High pass Filter , Low pass Filter.
ASSR:
Stimulus Rate : 40 or 90 Hz , Masking : White noise 0- 100 dB SPL , Display: Stimuli
level and frequency , session status , ASSR and Audiogram , Customer selectable
correction factors available.
DPOAE:
Frequency range : 500 – 8000 Hz , Frequency step : 50Hz, Stimulus Level : 30 – 75 dB SPL, Recording Analysis Time minimum 2 sec to unlimited test time , A/D Resolution : 16 bit , 3.7 Hz resolution , Sampling Frequency : 30 KHz.
TEOAE:
Frequency range : 500 – 5500 Hz , Frequency step : 50Hz, Stimulus Level : 50 – 90 dB SPLSampling Frequency : 30 KHz
Safety Standards:
IEC 60601 – 1 , Class I , Type BF and IEC 60601 – 1-1, class I, Type BF.
Must be European CE/ USFDA accredited.
Compatible Laptop system to be provided to run this machine. | 1 | Nos | 22,48,000 ₹22,48,000 Lowest | 23,15,000 ₹23,15,000 | - | - |
| 4.00 | Speech Trainers And Deaf Mute Equipments | 1 | Nos | 62,500 ₹62,500 | 57,500 ₹57,500 Lowest | - | - |
| 5.00 | Speech Therapy Material | 1 | Nos | 48,000 ₹48,000 | 44,500 ₹44,500 Lowest | - | - |
| 6.00 | OAE (Auto Acoustic Emission )
Type of OAE – TEOAE , DPOAE
Frequency range of TEOAE should be 4000 Hz or above and for DPOAE should be 5000 Hz or above
Thermal Printer with 2 paper rolls
Can be used as PC controlled or stand alone
Self Calibration
Instrument must be European CE/ USFDA accredited. | 1 | Nos | 4,48,000 ₹4,48,000 Lowest | 4,80,000 ₹4,80,000 | - | - |
| 7.00 | Mastoid Drill Machine
Should comprise of-Angled handpiece,Straight handpiece, ENT tungsten carbide cutting point of all sizes, ENT diamond (polishing) burrs of all sizes, complete set. | 1 | Nos | 3,98,000 ₹3,98,000 Lowest | 4,18,000 ₹4,18,000 | - | - |
| 8.00 | Electrical CAUTERY Machine | 1 | Nos | 1,18,000 ₹1,18,000 | 1,22,000 ₹1,22,000 | 92,500 ₹92,500 Lowest | - |
| 9.00 | Temporal Bone Microscope for Temporal Bone Lab | 1 | Nos | 6,85,000 ₹6,85,000 | 6,62,500 ₹6,62,500 Lowest | - | - |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
2 Dec 2020, 5:30 pmClosed
Principal PMC Dhanbad
Patliputra Medical College Koyla Nagar BCCL Township,Dhanbad
Purchase of Machine Equipment for ENT Deptt
2020_PMC_46422_5
1512/SNMMC
Open Tender
Medical Equipments/Waste
Item Rate
30 days
Principal Patliputra Medical College
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹1 L
Yes
24 Dec 2020
16 Nov 2020
4 Dec 2020
16 Nov 2020
2 Dec 2020
19 Nov 2020
17 Nov 2020 - 1 Dec 2020
Amount
Laying and Jointing PVC Pipe. Heading
Pure Tone Audiometer (Digital) Test available: Air Conduction: Frequency Range – 125 - 8000Hz Intensities - -10 to 120dB Bone Conduction: Frequency Range – 250 - 8000Hz Intensities - -10 to 80dB Special Tests - Stenger test, Free Field ,SISI ABLB. Tone - Continuous Tone , Pulse Tone , Warble Tone Maximum Hearing Level - Air – 10dB to 120 d B HL,(for SPL add 25.5 dB at 250 Hz) , Bone -10dB to + 80 dB HL, Speech -10dB to + 100dB HL , Masking – 10dB to + 100dB HL. Attenuator - Click free , 5 dB Masking - Narrow Band Masking. Presentation - Normal or Inverse mode for all signals External inputs- Tape recorder, CD Player or Microphone Accuracy of Frequency - Better than 1% Microprocessor controlled , SISI (Auto Calculation of Scores), PC Interface for on line Communication , Data storage facilities option Unlimited With PC, Software for patients with data base , Free Field Speakers with inbuilt amplifier, Audiometer must be European CE/ USFDA accredited.
Speech Trainers And Deaf Mute Equipments
Speech Therapy Material
OAE (Auto Acoustic Emission ) Type of OAE – TEOAE , DPOAE Frequency range of TEOAE should be 4000 Hz or above and for DPOAE should be 5000 Hz or above Thermal Printer with 2 paper rolls Can be used as PC controlled or stand alone Self Calibration Instrument must be European CE/ USFDA accredited.
Mastoid Drill Machine Should comprise of-Angled handpiece,Straight handpiece, ENT tungsten carbide cutting point of all sizes, ENT diamond (polishing) burrs of all sizes, complete set.
Electrical CAUTERY Machine
Temporal Bone Microscope for Temporal Bone Lab
Revolving Stool
Stich Cutting Scissors
Scissors
OT Table ( for Minor OT )
Top Light (for Minor OT)
Ear Forceps
Syringing Instrument
Steriliser
Tray (Dressing)
Ear Forceps
Dressing Drum
Tuning Fork
Jobson’s Probe
Laryngeal Mirror (Diff. size-4)
Head Light for OPD
Nasal Speculum
Tongue Depressor
Foreign Body Removal Forceps
ASAP IMPACT PVT LTD
Apex India
EL MED IMAGING
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .