| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹16.3 LAccepted-AOC | ₹16.3 L | L-1 | Accepted-AOC Successful L-1 bidder |
| 2 | Rejected-Technical | - | - | Rejected-Technical Unsuccessful L-1 bidder |
| 3 | Rejected-Technical 1105 TOWER 6 PARK VIEW RESIDENCY PALAM VIHAR SECTOR 3 GURGAON HARYANA 122017 | GURUGRAM | HARYANA | 122017 | - | - | Rejected-Technical Unsuccessful L-1 bidder |
| 4 | Rejected-Technical | - | - | Rejected-Technical Unsuccessful L-1 bidder |
| 5 | Rejected-Technical | - | - | Rejected-Technical Unsuccessful L-1 bidder |
| Sl No | Description | Qty | Unit | M/s SATYASHILA L5 | Sunita Singh L2 | URMILA DEVI L3 | RAVIKANT KUMAR SINGH L1 | PUJA KUMARI L4 | Nirgandh Private Ltd L6 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Providing and fixing one no of prefabricated Indian Bio toilet unit consisting of 01 no of Bio toilet (1000*1000*2080mm), along with over head tank (Capacity 200 ltr) and Biodigester tank (350 ltr) with provision of suitable door with fittings, Ventiliator, Indian WC, Cistern, Angular cock (ABS) with health faucet, Connector pipe (PVC),Pillar cock (ABS), 2 in 1 Bib cock (ABS) along with 1/2 inch pipe line (Upvc) connection to be provided inside the toilet and required connectuion from over head tank (The make material is preferably FRP (3 to 5 mm thick) with MS supporting structure in the floor, walls and roof.) along with provision of one time adding Bio culture solution as per diretion of Engineer -in-charge. | 14 | EA | 75,000 ₹10,50,000 | 54,000 ₹7,56,000 | 49,000 ₹6,86,000 Lowest | 49,950 ₹6,99,300 | 55,000 ₹7,70,000 | 55,000 ₹7,70,000 |
| 2.00 | Periodic maintenance of Bio digester with addition of Bio culture chemical as per requirement all complete as per specification and direction of E/I. | 84 | EA | 2,200 ₹1,84,800 Lowest | 3,000 ₹2,52,000 | 3,000 ₹2,52,000 | 3,000 ₹2,52,000 | 3,500 ₹2,94,000 | 3,437 ₹2,88,708 |
| 3.00 | 19.32.1 (Ref. CCL SOR 2025) Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. | 14 | EA | 18,000 ₹2,52,000 Lowest | 20,000 ₹2,80,000 | 20,000 ₹2,80,000 | 18,500 ₹2,59,000 | 25,000 ₹3,50,000 | 30,000 ₹4,20,000 |
| 4.00 | 2.8.1 (Ref. CCL SOR 2025) Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.2.8.1 All kinds of soil. | 30.23 | M3 | 210 ₹6,348.3 | 200 ₹6,046 | 250 ₹7,557.5 | 130 ₹3,929.9 Lowest | 180 ₹5,441.4 | 205 ₹6,197.15 |
| 5.00 | 2.27 (Ref. CCL SOR 2025) Supplying and filling in plinth with Jamuna sand under floors, including watering, ramming, consolidating and dressing complete. | 2.39 | M3 | 1,850 ₹4,421.5 | 200 ₹478 Lowest | 200 ₹478 Lowest | 1,234 ₹2,949.26 | 800 ₹1,912 | 1,440 ₹3,441.6 |
| 6.00 | 4.1.5 (Ref. CCL SOR 2025) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) | 3.58 | M3 | 6,770 ₹24,236.6 | 1,000 ₹3,580 Lowest | 5,500 ₹19,690 | 4,500 ₹16,110 | 6,000 ₹21,480 | 6,775 ₹24,254.5 |
| 7.00 | 6.1.2 (Ref. CCL SOR 2025) Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) | 25.52 | M3 | 5,300 ₹1,35,256 | 6,500 ₹1,65,880 | 6,000 ₹1,53,120 | 5,200 ₹1,32,704 Lowest | 6,000 ₹1,53,120 | 6,770 ₹1,72,770.4 |
| 8.00 | 4.1.3 (Ref. CCL SOR 2025) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size | 3.15 | M3 | 7,424 ₹23,385.6 | 2,000 ₹6,300 Lowest | 6,500 ₹20,475 | 6,500 ₹20,475 | 6,800 ₹21,420 | 7,425 ₹23,388.75 |
| 9.00 | 5.22.6 (Ref. CCL SOR 2025) Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. | 200.4 | KG | 110 ₹22,044 | 200 ₹40,080 | 90 ₹18,036 Lowest | 95 ₹19,038 | 90 ₹18,036 Lowest | 105 ₹21,042 |
| 10.00 | 5.9.1 (Ref. CCL SOR 2025) Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete | 8.4 | M2 | 300 ₹2,520 | 100 ₹840 Lowest | 150 ₹1,260 | 350 ₹2,940 | 211 ₹1,772.4 | - |
Tender Value
₹22.6 L
EMD Value
₹28,300
Closing Date
7 Nov 2025, 11:00 amClosed
Staff Officer (Civil), Argada Area
Civil Office, GM Unit, Argada Area GM Unit, Argada area, CCL, Sirka-829101.
Provision of Bio Toilets (Indian) with periodic maintenance of one year at different locations under GM Unit, Argada Area.
2025_CCL_346013_1
SO(C)(A)/e-Tender18/25-26/2101
Open Tender
Civil Works - Others
Item Rate
45 days
GM Unit
Please refer Tender documents.
3 documents required · 3 mandatory
₹28,300
29 Nov 2025
22 Oct 2025
8 Nov 2025
23 Oct 2025
7 Nov 2025
23 Oct 2025
23 Oct 2025 - 31 Oct 2025
Amount
Providing and fixing one no of prefabricated Indian Bio toilet unit consisting of 01 no of Bio toilet (1000*1000*2080mm), along with over head tank (Capacity 200 ltr) and Biodigester tank (350 ltr) with provision of suitable door with fittings, Ventiliator, Indian WC, Cistern, Angular cock (ABS) with health faucet, Connector pipe (PVC),Pillar cock (ABS), 2 in 1 Bib cock (ABS) along with 1/2 inch pipe line (Upvc) connection to be provided inside the toilet and required connectuion from over head tank (The make material is preferably FRP (3 to 5 mm thick) with MS supporting structure in the floor, walls and roof.) along with provision of one time adding Bio culture solution as per diretion of Engineer -in-charge.
Periodic maintenance of Bio digester with addition of Bio culture chemical as per requirement all complete as per specification and direction of E/I.
19.32.1 (Ref. CCL SOR 2025) Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.
2.8.1 (Ref. CCL SOR 2025) Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.2.8.1 All kinds of soil.
2.27 (Ref. CCL SOR 2025) Supplying and filling in plinth with Jamuna sand under floors, including watering, ramming, consolidating and dressing complete.
4.1.5 (Ref. CCL SOR 2025) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
6.1.2 (Ref. CCL SOR 2025) Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
4.1.3 (Ref. CCL SOR 2025) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size
5.22.6 (Ref. CCL SOR 2025) Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
5.9.1 (Ref. CCL SOR 2025) Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
18.9.3 (Ref. CCL SOR 2025) Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement ,trenching ,refilling & testing of joints complete as per direction of Engineer in Charge.External work 25 mm nominal dia Pipes
12.41.2 (Ref. CCL SOR 2025) Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter
12.42.5.2 (Ref. CCL SOR 2025) Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Bend 110 mm bend
Total impact of GST for the purpose of CTC
Sunita Singh (BID ID -1196238)
URMILA DEVI (BID ID -1195832)
PUJA KUMARI (BID ID -1194708)
M/s SATYASHILA (BID ID -1195436)
Nirgandh Private Ltd (BID ID -1195486)
stage.html
html • 0.05 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_358687.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 2.48 MB
BOQ_358687.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .