Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.9 LAccepted-AOC | L1 | Accepted-AOC ok | |
| 2 | L2₹32.1 L+₹23,151.20 (0.73%)Rejected-AOC WARD NO 11 THIRIYA NIZAWAT KHAN BAREILLY | BAREILLY | BAREILLY | L2 | Rejected-AOC ok | |
| 3 | L3₹32.6 L+₹67,212.60 (2.11%)Rejected-AOC 110B CIVIL LINES BAREILLY 243001 UP | BAREILLY | UTTAR PRADESH | 243001 | L3 | Rejected-AOC ok | |
| 4 | L4₹32.6 L+₹76,992 (2.42%)Rejected-AOC | L4 | Rejected-AOC ok | |
| 5 | L5₹37.8 L+₹5.9 L (18.5%)Rejected-AOC BUNGALOW NO 21 CANTONMENT BAREILLY 243001 | BAREILLY | UTTAR PRADESH | 243001 | L5 | Rejected-AOC ok |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
2 May 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE WEST BAREILLY
GE WEST BAREILLY
REPAIR/MAINT OF U/S SECURITY LIGHTS, LT EXTERNAL ELECTRIFICATIONS AND ALLIED WORKS INCL DAILY MAINT OF SECURITY LIGHTS AT 06 MTN DIV AOR AND 23 (I) R AND O FLIGHT UNDER GE (W) BAREILLY
2022_MES_516644_1
8045/C/E8
Open Tender
Civil Works
Item Rate
270 days
GE WEST BAREILLY
SCANNED COPY OF ENLISTMENT LETTER IN MES IN RELEVANT CLASS CATEGORY SCANNED COPY OF APPLICATION ON LETTER HEAD OF FIRMSCAN COPY OF DD OF RS 500.00 IN FAVOUR OF GE WEST BAREILLY FROM ANY NATIONALISED OR SCHEDULED BANK SCANNED COPY OF REGISTRATION
6 documents required · 6 mandatory
₹500
Yes
GE WEST BAREILLY
₹94,000
Yes
13 May 2022
5 Apr 2022
4 May 2022
5 Apr 2022
2 May 2022
20 Apr 2022
5 Apr 2022 - 19 Apr 2022
60 days
Amount
Dismantling of SVL /LED /Flood light fittings of any capacity from existing poles / buildings of any height/type including re-fixing after repair/replacment of unserviceable parts and making the fitting functional by replacing minor parts as required at site complete all as specified and directed. Notes:- (a) Spares shall be measured & paid separately as given here-in-after. (b) Contractor shall provide minimum 1 Electrician and 1 helper to carry out the repair / Maint work of security lights in day shift (9000 Hrs-1700 Hrs) and they have to report AGE E/M-I yard for daily assingment/task (c) Contractor shall provide all tools and plants and minor spares such as Ladder minor nuts bolts, jumper wire, insulation tape etc required for doing the job related with electric supply and will be fully responsible for safety and security of their man. ( d) In case non reporting of required staff in AGE E/M yard the recovery shall be made @ Rs 500/= per day will be leived .
Supply and fix in replacement new generation energy saving & environmental friendly long life versatile pressure die- cast aluminium IP 66 roadway luminaire with high power LED as light source and electronic driver of following capacity including necessary connections with 2.5 sqmm aluminum wire complete all as specified and as directed (a) 48/50 Watt Make:- Havells, Bajaj, C&S or equivalent
(b) 60 Watt
(c) 70/72 Watt
(d) 90 Watt
S&F in replacement light fitting JETAIRIS Energy saving environmental friendly, exclusive innovative designed, long life versatile pressure die cast aluminium IP-66 flood light luminaire with high power LED 150 W. Make : Havells, Bajaj, Surya, C&S.
S&F in replacement light fitting JETAIRIS Energy saving environmental friendly, exclusive innovative designed, long life versatile pressure die cast aluminium IP-66 flood light luminaire with high power LED 120 W. Make : Havells, Bajaj, Surya, C&S.
Supply only of Integral LED street light driver, enclosed with glass cover frame suitable for following sizes LED light for existing complete all as specified and directed. (a) 30 Watt to 50 Watt Make:- Havells, Bajaj, C&S, Surya or equivalent
(b) 60 Watt to 72 Watt
Supply only of Integral LED street light module with complete PCB and LED suitable for following sizes of LED street light for existing complete all as specified and directed. (a) 30 Watt to 50 Watt
(b) 60 Watt to 72 Watt
Supply only cable two core PVC insulated and unsheathed multistranded aluminium conductor of size 2.50 Sqmm complete all as specified and directed.
S&F in replacement MCBs TPN 63 Amps,415 Volts 16 KA all as specified and directed.
S&F in replacement MCBs SPN 32/40 Amps,220 Volts 10 KA all as specified and directed.
S&F in replacement MCBs Single Pole 6-32 Amps 10 KA ,220 Volts all as specified and directed.
S&F in repair loop-in-loop out box of size 30x20x20cm made out from 1.6mm thick PVC sheet weather proof, dust and vermin proof with hinged door and locking arrangements with slanting cover on top and provision of 4 Nos aluminium bus bar of size 25mm x 2mm-4 Nos fixed on insulator and one MCB of capacity 6 Amps complete fixed on pole with and including suitable size MS flat iron clamps, nuts,bolts & washers etc complete all as specified and directed
S& F in replacement new generation post top energy saving environment friendly, long aesthetically designed with symmetrical light distribution spun aluminium landscap luminaire with power LED of 35 Watt as light source of 35 Watt of Make Havells, C&S or equivalent to Bajaj/Philips
S& F in replacement sturdy LED Bollard with excellent light out through its sleek PMMA window ensuring maximum iluumination aspect in surrounding of 10 Watt complete all as specified and directed. Make Havells, C&S or equivalent
Supply and fixing street light bracket made out of GI pipe light grade 32 mm dia of length upto 1.2 mtr bent to shape required with and including 2 Nos, 50 x 6 mm MS flat iron clamps with nuts, bolts, washer etc and applying one coat of aluminium paint to clamps including dismantling of old brackets complete all as specified and directed.
Supply ,fixing ,commisioning and testing of Nature timer switch control Street Lights complete with MCB, Power and Panel duly complete with wiring Model : SWADEEP-02EC 05KW IP, single phase, max load 05 KW complete all as specified and directed. Note :- CA No & date of installations shall be painted/marked on all timer switch provided by the contractor
Supply ,fixing ,commisioning and testing of Nature timer switch control Street Lights complete with MCB, Power and Panel duly complete with wiring Model : SWADEEP-02EC 12KW3P, three phase, max load 12KW complete all as specified and directed. Note :- CA No & date of installations shall be painted/marked on all timer switch provided by the contractor
S&F 1100 Volts grade heavy duty cable one twin core, flat or circular PVC insulated aluminium stranded conductor of following sizes served with inner sheathing of PVC tapes and overall PVC sheathed in service connection from pole to Main Switch complete all as specified and directed. Make : Havells/ Polycab/Richa. (a) 6 sqmm
(b) 10 sqmm
Periodical maintenance of complete runway lighting system and repair by dismantling of air field/taxi track light fitting, AFL Cable & Connection of any description and segregatting to servicable and unserviceable parts and make it in serviceable condition by deploying person who have knowledge about Air field light system, Constant current regulator and Beacon light compelte all as specified and directed. Note (i) Replacement of spare parts will be measure and paid separately under respective item of schedule. (ii) T&P and HT insulation tape required for repair will be arrange by the contractor with his own cost. (iii) Day of maintanence/ repairs intimate by the dept prior to flying twice in a month. (iv) Failed to maintaining Runway light system for flying will be penalty of Rs 2000/- borne per job by the contractor.
S&F bipin halogen lamp 200 watt 6.6 Amp 50 HZ all as directed by Engr-in-Charge.
S&F bipin halogen lamp 45 watt 6.6 Amp 50 HZ all as directed by Engr-in-Charge.
S&F Bipin halogen holder for 200/45 watt lamps complete with chord complete all as specified and directed
S&F isolating transformer 200W, 6.6 Amp, 50 Hz all as directed by Engr In Charge. Make- Bildal/ AMA
S&F isolating transformer 45W, 6.6 Amp, 50 HZ all as directed by Engr In Charge.
S&F Protection Glass cover with washer for 200 watt runway light (Clear white) complete all as specified and directed.
S & F Protection Glass cover with washer for 45 watt Taxi track light (Blue) complete all as specified and directed.
S&F 6 Sqmm AFL cable connector (male female joint kit) complete all as specified and directed.
S&F in repair Run way light fitting 200 watt including lamp, 6.6Amp, Complete with outer lens, inner lens/filters, base plate rubber gasket, lamp, lamp holder isolating transformer etc complete all as specified and directed Make AMA ALN/Metro or equivalent
S&F in repair Taxi way light fittings 45 watt including lamp, 6.6Amp, Complete with outer lens, inner lens/filters, base plate rubber gasket, lamp, lamp holder isolating transformer etc complete all as specified and directed Make AMA ALN/Metro or equivalent
M&L for servicing, Oiling, greasing and testing of Beacon lights including replacement of unsv spares as required complete all as specified and directed.
S&F in repiar LED aviation obstruction light 12 Watt with fitting complete and making electric connections.Note :- Obstruction lights are to be replaced/fixed at Hangers/ATC
S&F in repair Approach light fittings 200 watt including lamp, 6.6Amp, Complete with outer lens, inner lens/filters, base plate rubber gasket, lamp, lamp holder isolating transformer etc complete all as specified and directed Make AMA ALN/Metro or equivalent
Excavation in trenches n. exc. 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of underground cable and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removing of excavated soil to a distance not exceeding 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L for sand cushioning with layer of sand 8cm thick before laying of cable and 15cm after laying of cable in trenches, punning complete all as specified and directed Note:- Punning thickness of 18 cm will be considered for payment.
M&L for providing of new sub class 'B' Bricks, well burnt laid flat dry for protection of under ground cable complete all as specified and directed.
Laying only old bricks obtained from item ser No 38 complete all as specified and directed.
Taking out old unserviceable Old LT cable any type and size from trenches or fixed on poles or through pipes/walls/laid under roads/paths/ drains/culverts including Old Bricks complete all as specified and directed.
Supply and laying in replacement of OH ACSR Conductor / XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor 1100 volt grade, laid in trenches/ducts, fixed on wall/inside panel, drawn through pipe of cross sectional area 185 Sq mm 3.5 core all as specified and directed. Note :- Rate deemed to be inclusive of connection including cable glands and lugs.
All as per Ser item Ser No 39 here-in-before but 120 Sq mm 3.5 core
All as per Ser item Ser No 39 here-in-before but 95 Sq mm 3.5 core
All as per Ser item Ser No 39 here-in-before but 25 Sq mm 4 core
All as per Ser item Ser No 39 here-in-before but 16 Sq mm 4 core
All as per Ser item Ser No 39 here-in-before but 10 Sq mm 4 core
All as per Ser item Ser No 39 here-in-before but 10 Sq mm 2 core
S&F in replacement HT tropodome PVC insulated sheathed, AFL cable 6.6 Amps 5000 volts, with copper conductor 6 sqmm single core mltistranded including taking out of old cables complete all as specified and directed.
M&L in repair for boring of holes under road /pavement/hard standing or any other situation by mannual means for 80/50mm bore for crossing the cable and making good both the ends all as specified and directed at site. Note :- GI pipe shall be measure and paid separately under respective item.
S & F in replacement GI pipe light grade of following dia for cable protection, fixed to pole/ alongwall/ floor/ under road/ across the drain or nallaha etc complete all as specified & directed. (a) 50 mm dia
(b) 80 mm dia
M&L in repair for MS Cage for protection for Run way light and Taxi light, made out from steel framed bracket, nosing to steps including embeding in concrete and screwing etc. posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire,wire mesh etc, flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc.and similar work conforming to Fe-290 Gde E-165, as per sample complete all as specified and directed.
S&F in repair bulk head fittings for landing T with 100W warm white lamp, holder with glass top cover and including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230 volt 50 Hz complete all as specified and directed.
Lopping / prooning of tree branches upto the extend to obtain clearance all around the LT over head lines / street light poles upto 3 mtr from furthest conductor / pole including removing of cut branches and cleaning of site complete all as specified and directed. Note:- (a) Tools & plants including safety measures equipments like belt, ladder & ropes etc shall be arranged by the contractor at own cost. (b) Contractor supervisor will take proper shut down before starting the work and clear it before resuming power supply, however full assistance will be provided by MES Staff.
Opening the binding wire from pin /shackle insulator on steel pole of any height for re-stretching the ACSR conductor , after re-stretching without kinks & bends, binding the pin /shackle insulator with appropriate size of aluminium binding wire complete all specified & directed by Engineer-in- charge. Note: 1. Cost of binding wire deemed to be included in the quoted rate, No extra amount will be paid. 2. One RM length will be measured for 03 phase and one neutral one street light and one earth wire.
S&F in replacement stay assembly complete comprising of 20mm dia 40cm long stay bow rod 16mm dia x 1.8 Mtr long stay rod threaded and with nuts including 300mmx300mmx6mm thick plate necessary clamps etc as specified and directed. ( Note : Loop type insulator, stay clamp, stay wire, excavation and concrete measured separately).
S&F in replacement shackle type porcelain vitreous white, brown or green insulator including one galvanised mild steel straps, washers and nut 75 mm height, 90 mm dia for 1100 volts grade, complete all as specified and as directed.
S&F in replacement pin type porcelain vitreous white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut 100 mm height, 65 mm dia for 1100 volts grade, complete all as specified and as directed.
S&F in replacement, fabricating and fixing in replacement of cross arms (any type) supports, bracting, stiffness etc made out of MS channel, angle iron, flat iron of any size including drilling of holes, making clamps, eye hooks, nuts, bolts and washers etc, welding if required including painting with two coats of aluminium paint over a coat of red oxide paint complete all as specified and directed.
M&L for cleaning and preparation of old painted surface of LT steel tubular pole complete and painting with one coat of aluminium paint including channels/brackets, street light brackets, cross arms and making Black/Red/Yellow & white strips with synthetic enamelled paint of 30cm height, each alternative strip upto 1.5 mtr height and writing pole numbers with yellow synthetic enamelled paint after making circular base with black synthetic enamelled paint and applying two coat of white wash on PCC coping complete all as specified.
M&L for earthing complete with galvanised or steel earth plate electrode of size 60cm x60cmx6mm thick burried directly in ground vertically ( to a depth not less than 2.25mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to GI wire 4mm dia with nuts, bolts , check nuts , washers, earth plate surrounded by packed layers of charcoal dust and common salt 15cm thick all around, top & bottom watering pipe 20mm bore of GI medium grade with funnel and wiremesh all as shown in electrical plate No. 5 of SSR -1991 Part I and connecting to arthing test point,main switch board and testing on completion including PCC chamber concrete 1:3:6 type C-2 and RCC cover 75mm thick with MS TMT bar 8mm dia @ 150mm c/c both ways in cement concrete(1:2:4) type B-1 all asshown in electrical plate in No 5 of SSR (Pt-I)1991 complete all as specified and dirfected by Engineer-in-charge.
Supply & fixing in replacement ACSR conductor of any size including binding on existing LT poles or new poles with 02 mm dia aluminium binding wire all as specified & directed.
S&F in repair MCCB 415 Volts 4 pole 400 Amps 50 Hz 36 KA alongwith spreader terminal with adjustable thermal setting including lugs/thimbles of suitable size in existing panels complete all as specified and directed. Make : L&T/Legrand /Havels/C&S. Note :- Necessary addition /altration required to adjust MCCB in the panel shall be done by the contractor and no extra payment will be made to the contractor.
All as per Item Ser No 55 here-in-before but of MCCB 250 Amps 4 pole 50 Hz 415 V, 25 KA
All as per Item Ser No 55 here-in-before but of MCCB 200 Amps 4 pole 50 Hz 415 V, 25 KA
All as per Item Ser No 55 here-in-before but of MCCB 125 Amps 4 pole 50 Hz 415 V, 16 KA
All as per Item Ser No 55 here-in-before but of MCCB 100 Amps 4 pole 50 Hz 415 V, 16 KA
S&F in replacement Isolator 4 pole 100 Amps, 415 Volts complete all as specified and directed.
Dismantling of LT PCC/Steel tubular pole of any size and discription incl coping, foundation etc complete all as specified and as directed.
Supply and erection, in truly vertical position, LT Steel tublar swaged pole complete with cast iron base plate finial taper plug, bolt , nut and screwed type 410 SP 31 09 mtrs long Class -10 including painting of poles with two coats of synthatic enamel paint in black and white strips upto 1.5 mtr height from coping over a coat of red oxide primer including numbering of poles as directed by Engineer in charge. Note : PCC, Earth work and MS work as cross arms clamps etc will be measured and paid separately.
M&L for PCC type B1 (1:2:4) using 20 mm graded aggregate as in coping to the poles complete all as specified and directed.
M&L for PCC (1:3:6) type C2 using (40 mm graded aggregate in foundation, filing and mass concrete complete all as specified and directed.
M & L fabrication of MS Busbar chamber of nominal dimension 900 mm x 600 mm x 400 mm duly provided with aluminimum busbar of size 50 mm x 6mm fixed on porcelain insulators TPN type out door weather/vermin proof with both way opening duly provided with neoprene rubber gasket along the doors openings pedestal type duly painted powder coated on CRCA steel sheet encloser with one No incommer MCCB 250 Amp 36 KA incl making connection /thimbles complete all as sepcified and directed
Repair of Constant current regulator of capacity 20KW, 6.6 AMP static type complete and incl taking down /transporatation complete all as specificed and directed.
Repair of Constant current regulator of capacity 4 KW, 6.6 AMP static type complete and incl taking down /transporatation complete all as specificed and directed.
Note : (i) Day to Day Complaints pertaining to Street Light/LT External Electric Supply shall be resolved by the contractor immediatelly after getting complaints. In case of failure on the part of contractor to resolve to the complaints within stipulated time, a penalty of Rs 500/- per day per complaint shall be imposed from the contractor. (ii) The contractor or his authorised representative shall report to the concerned JE E/M at 09:00 hours dailly on all working days to receive order/instructions of the work. A register shall be maintained to record all orders & instructions and their complaints and is to be signed by the contractor/his representative and the Engineer-in-charge/JE E/M concerned. (iii) Work done register to be maintained by the contrator. A separate Docket complaints slip book shall maintained by the contractor to note the complaints/jobs and get it signed by the user after completion of work and submits to the JE-in-Charge.
N S ELECTRICALS
M/S Rajeev Sharma and Co.
LEEJA ENTERPRISES
prabhave traders
NOORI ENTERPRISSES
Ishtiaq and Sons
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .