Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.7 LAccepted-AOC 00 BEHIND COURT PHALODI NAI SARAK PHALODI JODHPUR RAJASTHAN 342301 UDYAM RJ 22 0048153 | JODHPUR | RAJASTHAN | 342301 | L1 | Accepted-AOC Lowest Bidder, Hence accepted | |
| 2 | L2₹3.0 L+₹12,000 (4.21%)Rejected-Finance 102 VYAS COLONY NEAR AIR FORCE JODHPUR 342011 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342011 | L2 | Rejected-Finance Not Lowest Bidder, Hence Rejected | |
| 3 | L3₹4.1 L+₹1.3 L (45.3%)Rejected-Finance 00 LALPUR KICHHA ROAD RUDRAPUR KICHHA RUDRAPUR UDHAM SINGH NAGAR UTTARAKHAND 263148 | UDAM SINGH NAGAR | UTTARAKHAND | 263148 | L3 | Rejected-Finance Not Lowest Bidder, Hence Rejected | |
| 4 | L4₹4.7 L+₹1.9 L (65.3%)Rejected-Finance | L4 | Rejected-Finance Not Lowest Bidder, Hence Rejected | |
| 5 | Rejected-Technical 77 KAILASH PURI BIKANER RAJASTHAN PIN 334001 | BIKANER | BIKANER | RAJASTHAN | 334001 | - | Rejected-Technical Remarks in WLR for the QE Jun 2020 is NO. Hence, rejected |
Tender Value
Refer Docs
EMD Value
₹9,980
Closing Date
16 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) PHALODI
Military Engineer Services Garrison Engineer (AF) Near Kundal Village, Phalodi (Rajasthan)-342 301
REPAIRS TO GEYSERS AND CONNECTED WORKS AT AF STN PHALODI
2020_MES_377897_1
8287/A/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
PHALODI
All contractors enlisted with MES in Class E and above and category b(i) subject to the remarks wrt performance in respect of Wks in hand reflected in Workload return (WLR) Circulated by competent engineer authority. - Refer Note
7 documents required · 7 mandatory
₹300
GE (AF) PHALODI
₹9,980
Yes
13 Nov 2020
15 Sept 2020
19 Oct 2020
15 Sept 2020
16 Oct 2020
3 Oct 2020
15 Sept 2020 - 27 Sept 2020
60 days
Amount
Disconnecting water and electric connection in existing position of geyser of capacity 25/50 Ltrs & taking down geysers fixed to wall at any height, transporting to deposit in MES store yard for inspection of Engr-in-charge to ascertain the serviceability/ unserviceability, and quatam of repairs involved & including transportation of serviceable geyser of capacity 25/50 Ltrs from workshop to building site as directed for fixing in existing position with making water and electric connection and testing complete all as specified and directed. Note:- (i) The spare parts will be measured and paid separateley against appropriate items of BOQ. (ii) Contractor will depute one electrician and one helper on daily basis for collecting of complaints from AGE E/M office and same will repair/replace on same working day and no extra payment is given to contractor. (iii) The contractor should provide vehicle for attending of daily basis complaint and carry unservicable /serviceable geysers to the work site & AGE E/M office or vice versa. (iv) All above provisions included in quoted rate.
Supply only for renewal under item No 01.00 (here-in-before) of the following spare for geysers 25/50 Ltrs capacity complete all as specified and directed :-
Heating element with rubber washer ('O' ring) cap 1.5/2 KW (round) any type complete all as specified and directed.
Heating element with rubber washer ('O' ring) cap 1.5/2 KW (triangular) any type complete all as specified and directed.
Indicator bulb neon round/square type, single phase, 230 Volt, complete all as specified and directed.
Safety plug 15mm (brass) for geyser of capacity 25 Ltrs complete all as specified and directed.
Thermostat 30°C to 70°C rated current 10-15 Amp, 230 Volts, complete all as specified and directed.
Glass wool complete all as specified and directed.
Inner tank of steel sheeting for geyser of capacity 25 Ltrs complete all as specified and directed.
Inner tank of steel sheeting for geyser of capacity 50 Ltrs complete all as specified and directed.
Inlet/outlet water assembly brass for geyser of capacity 25/50 Ltrs complete all as specified and directed.
Bottom cover for geyser of capacity 25/50 Ltrs, of any type in two halves as per existing of geyser Make complete all as specified and directed.
Safety valve for suitable cap of 25/50Ltr of geyser complete all as specified and directed.
S & F in renewal of PVC flexible inlet outlet connection 15 mm dia, 45 cm long with brass, nuts, bolts and washers etc, heavy duty, ISI marked complete all as specified and directed.
S & F in renewal of PVC connection 15 mm dia, 60cm long, with brass nuts, bolts and washers etc, heavy duty, ISI marked complete all as specified and directed.
M & L for stopping the leakage by brazing of inner copper/steel tank not exc 2.5 cm in length and making the tank leak proof & including testing etc complete all as specified and directed.
S & F in renewal of outer body/cover suitable for 25 Ltrs cap geyser made out of mild steel pre-treated and stove enamelled sheet of 18 SWG with top and bottom cover, rubber gasket, stead screw for fixing the top and bottom cover to outer body easing and including two coat of white synthetic enameled paint over and including one coat of red oxide primer complete all as specified and directed.
M & L in renewal of grouting the bolt of size 6"x1/2" with nut in wall for fixing the geysers of capacity 25/50 Ltrs complete all as specified and directed.
M & L in renewal of MS bracket for mounting of Geyser of capacity 25/50 Ltrs complete all as specified and directed.
M & L for spray painting to geysers of capacity 25/50 Ltrs with two coat of synthetic enamel white paint over and including one coat of red oxide (primer) & including scratching of old paint and making surface smooth by using filler etc complete all as specified and directed.
M & L for writing letters or figures (Block. Roman, Italic or Indian) height of serially painting numbers n exc. 30 cm on the Geysers with yellow background and black letters of synthetic enamel paint 1st grade complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete including teak wood battens or from existing conduits with all fittings, such as switches, ceiling rose, pendants, sockets, lamp holder, fan regulators, sketch/brackets light fittings (except tube light fitting) etc but excluding ceiling fan and removal of old material from site and making good disturbed surfaces of walls, floors, ceiling etc to match with existing surfaces complete all as specified and directed.
M & L for point wiring complete with 1.5 Sqmm (nominal cross section area) FR-LSH PVC insulated multistranded unsheathed copper conductor cable drawn in and including UPVC casing capping of size not less than 25x12mm, hooks, elbows, junction covers and junction boxes including suitable size of PVC electrical gang boxes fixing for switches / regulators/ sockets on the wall & including 1.5 Sqmm PVC insulated unsheathed multistranded, FR-LSH copper conductor wire as earth continuity to common earth and connecting to earth dolly for one light point controlled by one switch, bell push or one fan point controlled by one switch complete all as specified and directed.
S & F switch piano flush type, single pole, one way, 5/6 Amps, 240 volts, ISI marked complete all as specified & directed.
S & F for circuit/submain wiring longwith earth wire in PVC Casing Caping with sizes 2x2.5 Sqmm (Main) +1x1.5 Sqmm (Earth wire) of FRLS PVC insulated copper conductor, single core cable in surface/recessed as required and including taking down carefully old U/S copper /aluminium sub main wiring alongwith earth wire of size as per existing complete all as specified and directed. Note :- Submain wiring two run & including one run earth wire shall be measured as one run for the purpose of measurement and payment.
S & F in renewal of sheet metal enclosure with two pin plug and earth plug and socket complete with and including one MCB SP 20 Amps, 240 volts, 'C' curve type, heavy duty, complete all as specified and directed.
S & F in renewal of MCB single pole 6 to 32 Amp, 'C' curve having rupturing capacity 10 KA conforming to IS-8828-1996, IEC-60898, complete all as specified & directed.
S & F in renewal of plug top 3 pin 15 Amp for geyser conncetion, ISI marked complete all as specified and directed.
S & F in renewal of metal clad plug top and socket 3 pin 15 Amp for geyser conncetion, ISI marked complete all as specified and directed.
S & F in renewal of one switch and one socket semi flush type 5 pin 15 Amp, 230 volts, AC, ISI marked complete all as specified and directed.
M/s Shiv Builder and Suppliers
S R ENTERPRISES
M/S RAKESH CHOUDHARY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .