Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.2 LAccepted-AOC 7 32 1 PRASANTHI NAGAR GOPALAPATNAM VISAKHAPATNAM 530 027 | VISAKHAPATANAM | ANDHRA PRADESH | 530027 | L1 | Accepted-AOC LOWEST TENDER | |
| 2 | L2₹30.6 L+₹1.2 L (3.95%)Rejected-Finance 66 6 410 1 MULAGANDA HOUSING COLONY GAJUWAKA DEPOT VISAKHAPATNAM 530026 | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹30.8 L+₹1.4 L (4.76%)Rejected-Finance DOOR NO 38 I H COLONY MALKAPURAM POST VISAKHAPATNAM 530 011 | VISAKHAPATANAM | ANDHRA PRADESH | 530011 | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹34.0 L+₹4.6 L (15.6%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹34.6 L+₹5.1 L (17.4%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | BAPATLA | ANDHRA PRADESH | 504214 | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
25 Jun 2021, 6:00 pmClosed
Garrison Engineer Utility-II
Garrison Engineer Utility-II 104 Area Industrial Estate Post Visakhapatnam -530 007
MANNING AND OPERATION OF FF PH AT MO V NEW SITE BOOSTER PH AND SEWAGE PH AT M PETA AND OPERATION OF CONTROLLING VALVES AT NEW AND OLD M PETA ASHOKA PARK AND OPERATION OF DG SETS AND CERTAIN MISC REPAIRS TO WS DISTRIBUTION SYSTEM AT M PETA MO V WED NA
2021_MES_435816_1
8772
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Garrison Engineer Utility-II Visakhapatnam
CLASS D
8 documents required · 8 mandatory
₹500
Garrison Engineer Utility-II
₹96,000
Yes
6 Jul 2021
21 May 2021
26 Jun 2021
21 May 2021
25 Jun 2021
12 Jun 2021
Amount
Manning and Operation of booster pump house at M' Peta, operation of DG set, operation of sewage upmp house at 'M' Peta and controlling of distribution valves as per timings at Booster Pump House M' Peta, residential Qtrs M' Peta and Ashoka Park in three shifts per day of 08 hrs each including holidays and Sundays complete all as specified and as directed by Engineer-In-Charge. Man Power: 01 Semi-Skilled operator and 01 Unskilled per shift at Booster Pump House M' Peta Shift timings : Ist Shift 0600 Hrs to 1400 Hrs IInd Shift 1400 Hrs to 2200 Hrs IIIrd Shift 2200 Hrs to 0600 Hrs
Manning and operation of pump house MO(V), Fire Fighting Pump House at MO(V) and controlling of distribution valves as per timings at Pump House MO(V), residential Qtrs MO(V), NSB area, NAMAC area in three shifts per day of 08 hrs each including holidays and Sundays complete all as specified and as directed by Engineer-In-Charge. Man Power: 01 Semi-Skilled operator per shift at Fire fighting Pump House at MO(V) Shift timings : Ist Shift 0600 Hrs to 1400 Hrs IInd Shift 1400 Hrs to 2200 Hrs IIIrd Shift 2200 Hrs to 0600 Hrs
Manning and operation and controlling of distribution valves as per timings at Pump House MO(V), residential Qtrs MO(V), NSB area, NAMAC area, Ahoka Park valves in three shifts per day of 08 hrs each including holidays and Sundays including arresting leakages by replacing gland packing, cleaning and maintaining off all valve chambers, ensure proper locking of valve chambers complete all as specified and as directed by Engineer-In-Charge. Man Power: One Semi-Skilled ( Valve Man) per shift Shift timings : Ist Shift 0600 Hrs to 1400 Hrs IInd Shift 1400 Hrs to 2200 Hrs IIIrd Shift 2200 Hrs to 0600 Hrs
Note for SL item No. 1 to 3: The quoted rate is inclusive of following :- (a) Filling the sump and pumping water to various areas as directed by Engineer-in-Charge. (b) Operation of DG Set for electric supply during power failure of (APEPDCL) electric supply. (c) Attending minor break downs such as replacing of fan belt, gland rope, gland bolts and nuts etc., (d) Supply and filling of distilled water and electrolyte in batteries and coolant in radiators, recharging of batteries as and when required.
(e) After opening the delivery valves the unskilled trades man/helper should ensure that the water is reaching in each bldg. (f) unskilled trades man/helper should control over flow of water in each building during the supply of water. (g) Unskilled trades man/helper shall maintain installations neat and clean. (h) Before commencement of work the contractor shall submit the list of manpower to be employed as per requiste qualifications specified in particular specification for approval of GE duly recomended by Engineer-in- charge.
Supply only chlorine gas supplied in 100 kg cylinders for water treatment. Make: Andhra Sugars or its equivalent make approved by State Jal Board as approved by GE Note: (i) Testing the cylinders, and repair to outlet valves of cylinders and maintain the gas control and regulating system shall be the responsibility of Contractor and the rate is deemed to be included for the same (ii) Chlorine gas will be supplied in 100 Kg cylinder only.
Supply only chlorine test kit with coloured sample complete with all testing fitments and OT solution in rexine finished box complete all as specified and directed by Engineer-in-Charge,
Maintenance of Chloronomeplant including cylinders of 100 kgs and including periodical checking for leakage, rectifying the leakage, removing the empty cylinder from the chloronome plant and connecting the new cylinder as and when required complete all as specified and as directed. The quoted rate includes the following :- (a) Maintain the chlorine content of the treated water as per IS. (b) Maintain the record of water testing. (c) Replacing of damaged copper tubing of required size and length for connecting the cylinder to chloronome plant as and when required. (d) Connect / inject of chlorine gas to gravity feed gaseous chloronome plant.
Supply and replace LED street light fitting of 45 Watt capacity with IP66 protection inlcuding electronic driver and accessories suitable for pole dia upto 40 mm including GI bracket made of 40 mm gia Gi pipe light grade of length not less than 1.2metre bend to shape as reuired including necessary MS clamps, bolts, nuts & washers duly prewired 3 core 1Sqmm weather proof FRLS copper conductor to fittings, duly painted with 2 coats of synthetic enamel paint over a coat of primer complete all as directed by Engineer-in-charge. Make: CAT No. SLE UL 45W IP 66 LXN of Surya Roshini or its equivalent in Philips/ Havells India Ltd/ Wipro/ GE/ Bajaj.
Supply and replacement of MCCB 3 pole, 100 Amps, 415 Volts, with breaking capacity 36 KA (microprocessor release) complete all as directed by Engr-in-charge.
Supply and replacement of MCCB 3 pole, 160 Amps, 415 Volts, with breaking capacity 36 KA (microprocessor release) complete all as directed by Engr-in-charge.
Supply and replacement of MCCB 4 pole, 200 Amps, 415 Volts, with breaking capacity 36 KA (microprocessor release) complete all as directed by Engr-in-charge.
Supply and replacement of MCCB 4 pole, 250 Amps, 415 Volts, with breaking capacity 36 KA (microprocessor release) complete all as directed by Engr-in-charge.
Supply and replacement of MCCB 4 pole, 400 Amps, 415 Volts, with breaking capacity 36 KA (microprocessor release) complete all as directed by Engr-in-charge.
Supply and replace on load change over switch 4 pole, 415 Volts, 50 Hz, 200 Amps, complete all as specified and directed.
Supply, fixing & testing soft starter with contactor, 415 Volts suitable for motor of capacity 30 HP including taking down existing unserviceable complete all as specified and as directed.
Supply and fix 25 mm dia Gun metal gate valve, with iron wheel head, screwed both ends for iron pipe and fixed including cutting the pipe line and taking down old unserviceable valves wherever required complete all as specified and directed.
All as per SL item No.15 above but 40 mm dia
All as per SL item No.15 above but 50 mm dia
All as per SL item No.15 above but 80 mm dia
Excavating in trenches not exc 1.5 m wide and not exc 1.5 m in depth; for foundation, laying cables and getting out in soft/loose soil complete all as specified and directed.
Returning filling in, including spreading levelling watering and well ramming in layers n.exc 25 cm thick complete all as specified and directed.
Removing excavated surplus soil to a distance n.exc. 50m distance and depositing where directed at a level n.exc. 1.5 m above the starting point all as specified and directed.
Supply only 20 mm dia GI tubes medium grade with all fittings fixed to wall and ceilings or laid in floors complete all as specified and directed.
All as per SL item No.22 above but 25 mm dia
All as per SL item No.22 above but 40 mm dia
All as per SL item No.22 above but 50 mm dia
All as per SL item No.22 above but 80 mm dia
Labour for attending GI pipe line complaints (break downs) in buildings upto G+3 floor, terrace and plain area for pipe of size 20 mm to 40 mm dia including cutting and threading of pipes as per site requirement complete all as specified and directed by Engr-in-Charge.
Labour for attending GI pipe line complaints (break downs) in plain area / in trenches for pipe of size 50 mm to 80 mm dia including cutting and threading of pipes as per site requirement complete all as specified and directed by Engr-in-Charge.
Note for Item Nos 27 & 28: (i) Supply only GI Pipe shall be measured and paid separately under relevent items. (ii) The Quoted rate shall be deemed to include GI fittings and fixtures as required at site.
Supply and fixing in replacement of Glow-Sign Board of size 2000 mm x 1500mm x 200mm depth, made out of 1.60 mm thick PGI sheet frame with front cover made of 3 mm thick weather proof poly-carbonate sheet, writing, pasting the subject matter as given by the Engineer-in-Charge with self adhesive rubber coated synthetic vinyl sticker, including supply and fixing one number 20W LED tube lamp (of Make : Phillips/Bajaj) with all accessories prewired (internally to the glow-sign board) including providing all internal wiring and main connection and providing necessary fixing arrangement and testing on completion.
Supply, fix, testing and commissioning new 12 Volts, 180 AH In-built Battery charger including removing existing unserviceable one complete all as directed
Supply, fix, testing and commissioning new 24 Volts, 180 AH In-built Battery charger including removing existing unserviceable one complete all as directed
Supply and replace Contactor MCX - 32 complete all as specified and directed. Make:- Cat No CS97019 of L&T or its equivalent in ABB, BCH, Siemens , C&S Electric Ltd, Schneider
Supply and replace Contactor MCX - 34 complete all as specified and directed. Make:- Cat No CS97022 of L&T or its equivalent in ABB, BCH, Siemens , C&S Electric Ltd, Schneider
Supply and replace 1000 litres capacity Rotational moulded polyethylene three layer water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position as per site requirement as specified in SSR Part I complete all as directed
All as per SL item No.34 above but of capacity 500 litres
S & F in repairs for display board made up of 3mm thick Acrylic/Hard PVC sheet white in colour cut to a required shape and size (sqare/ rectangle ) with printed schematic /any matters/ description in computer aided adhesive applied PVC flex and pasted on the one side of Acrylic sheet and fixed on wall/Metel sheet with fixing arrangements by makeing drill as necessary and fixing screws including necessary board as directed. (Note :- 1. Soft copy of Description /printing matters/Drawings will be issued the Engr- in- charge. 2 .Colour code shall be of as directed by the Engr -in - charge .
Supply and fixing gland packing rope of 8/10/12/12.5/14/16mm sizes to pump sets of different sizes and capacities complete all as specified and directed
GVR CONSTRUCTIONS
Prasad and Suresh Constructions
GS ENGINEERS
M/S SRI VENKATA BHAVANI CONSTRUCTIONS
Sri Surya Enterprises
lakshmi Engineering Works
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .