GE (ARMY) CENTRAL JODHPUR
GE (ARMY) CENTRAL MULTAN LINE ARMY AREA JODHPUR
REPAIR AND MAINT OF WATER COOLERS DESERT COOLERS DEEP FREEZERS REFRIGERATORS GEYSERS AND SOLAR WATER HEATERS IN ARMY AREA UNDER GE ARMY CENTRAL JODHPUR (9137/E8)
2022_MES_549614_1
GE/J/A OF 2022-23 (9137/E8)
Open Tender
Civil Works
Item Rate
180 days
GE (ARMY) CENTRAL MULTAN LINE ARMY AREA JODHPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (ARMY) CENTRAL JODHPUR
₹66,000
Yes
17 Oct 2022
2 Sept 2022
3 Oct 2022
2 Sept 2022
30 Sept 2022
16 Sept 2022
Amount
Note:- (i) All items in BOQ are for "Materials and labour / Supply and fix" and to be executed in "Replacement/Renewal" unless otherwise specifically mentioned as "Supply only" or Fixing only" in BOQ Bidders are requested to quote their rates accordingly.
(A) WATER COOLERS:- M & L for disconnecting, loading, unloading and transportation of water coolers from existing location and position in A/A site for repairing of Water coolers of any make/capacity including reinstallation and testing at site after repairs all as directed by Engr-in-Charge NOTE : (i) Material required for defective / U/S parts shall be paid separately under relevent items.
M&L for checking of water cooler of any make / capacity in any location & position at any site in Army Area Jodhpur, including necessary servicing i.e. making good electrical including copper terminal, cleaning, drain water system including replacement of hose clamp etc., complete, cleaning condensor, condenser fan motor, door gasket, cleaning storage water tank cleaning and testing for proper functioning of water cooler all as directed by Engr-in-Charge.( The rates are deemed to be included for maintaining complete and proper record of machine ie: make with srl no ,SM no. capacity, date of servicing , user signature after servicing , concerned JEs signature all as directed by Engineer in-charge )
M&L for replacement of unserviceable hermetically sealed compressor of water cooler 150 Ltr storage having cooling capacity 100 Ltrs / hour Capacity with fresh new uncut sealed unit compressor including suitable relay and over load with new sealed unit as per the company scheme supplied by the manufacturer complete including flushing out system, checking and rectfication of leakage, gas charging, complete NOTE :- (i) The rate quoted by the contractor shall be inclusive of all charges ie: test certificate and necessary guarantee period as per manufacturing company (ii) The new unit will be purchased from authorized dealer only as per existing make and model. Make : Whirlpool/ LG/ Godrej
All as per ser item No 4.00 above but for 60/120 Ltr storage capacity with cooling capacity 60 Ltrs / hour water cooler Make : Whirlpool/ LG/ Godrej
All as per ser item No 4.00 above but for 40/80 Ltr storage capacity with cooling capacity 40 Ltrs / hour water cooler Make : Whirlpool/ LG/ Godrej
M&L for replacement of copper filter and capillary tube of water cooler cooling capacity 40 Ltr/hrs, complete all as specified and as directed.
M&L for replacement of of copper filter and capillary tube of water cooler cooling capacity 60 Ltrs per hour, complete all as specified and as directed.
M&L for replacement of copper filter and capillary tube of water cooler cooling capacity 100 Ltr per hour, complete all as specified and as directed.
M&L for replacement of relay with over load protection for 40/80 Ltr/hrs cooling capacity suitable as per site requirement, complete all as specified and as directed. Make : Ranutrol/ Rockwell/ Annapurna
M&L for replacement of relay with over load protection for 60Ltr/hrs cooling capacity suitable as per site reuqirement, complete all as specified and as directed. Make : Ranutrol/ Rockwell/ Annapurna
M&L for replacement of relay with over load protections for 100 Ltr/hrs cooling capacity suitable as per site requirement, complete all as specified and as directed. Make : Ranutrol/ Rockwell/ Annapurna
M&L for replacement of condensor fan motor HP-1/32, RPM-1300 suitable for water cooler having cooling cap 40 Ltr/hr with clips and motor fixing stand with fan blade ISI marked, complete all as specified and as directed. Make : AUE or Equivalent
M&L for replacement of condensor fan motor HP-1/16, RPM-1300 suitable for water cooler having cooling cap 60 to100 Ltr/hr with clips and motor fixing stand with fan blade ISI marked, complete all as specified and as directed. Make : AUE or Equivalent
M&L for Repalcement of thermostat switch with knob for water cooler, having cooling capacity 40/60/150 Ltrs/hr, complete all as specified and as directed. Make : Rasnutrol no 1051 or Indfoss No 2064/ Annapurna
M&L for patch repair work of worn out MS body of water cooler any capacity made out of 22 gauge mild steel sheet including welding and making good with paint to match with existing all as specified and directed by Engineer-in-Charge.
M&L for replacement of drain PVC pipe, 25 mm bore for cooling cap 40 Ltr /Hrs 90 cms in length with two Nos mild steel clamps and necessary brass screws etc., complete all as specified and as directed. Make : RAJDOOT/ KOHINOOR
All as per item No. 17 above but size 32 mm bore suitable for cooling Cap 60 to 100 Ltrs/Hrs water cooler and not more than 1.00 meter, complete all as specified and as directed.
M&L for replacement of SS drain water tray made out of 24 gauge stainless Steel sheet of size of 30x12x5 cm deep with necessary GI screws and PVC drain water connection arrangement of size not less than 25 mm dia, all as directed (as per sample)
M&L for replacement of water storage tank top lid complete made out of 22 gauge mild steel sheet of existing shape and size for water cooler storage cap 120 to 150 Ltrs , of appropriate thickness on one side with door gaskit including , aluminium hinges 50 mm long 2/3 nos. and making good and painting with approved colour to match the existing colour, complete all as specified and as directed.
M&L for replacement of water storage tank top lid complete made out of 22 gauge mild steel sheet of existing shape and size for water cooler cap 80Ltrs., platic sheet of appropriate thickness on one side with door gaskit including , aluminium hinges 50 mm long 2/3 nos. and making good and painting with approved colour to match the existing colour, complete all as specified and as directed.
M&L for replacement of rubber magnet gasket fixed with top cover of water cooler of 80/120 litres storage capacity, complete all as specified and as directed.
M&L for replacement of rubber magnet gasket fixed with top cover of water cooler of 150 litres storage capacity, complete all as specified and as directed.
M&L for replacement of worn out bottom base of water cooler foundation frame made out of 1.6mm thick MS sheet for water cooler, & frame work made out of angle iron25x25x3 mm, including cutting welding brazing soldering , making holes for sealed unit , condenser with condensor fan motor , including painting black colour (two coats) synthetic enamelled paint over a coat of red oxide primer etc and finishing, complete all as specified and as directed.by Engineer-in-Charge.
M&L for replacement of water cooler body back sheet with 22 gauge mild steel sheet including suitable size( as per existing) and necessary painting, screws etc., complete all as specified and as directed by Engineer-in-Chage
M&L for replacement of water cooler front pannel with 20 gauge mild steel sheet including suitable size( as per existing) and necessary screws/nuts/bolts/washers etc. for 40 ltrs/hour capacity, complete all as specified and as directed by Engineer-in-Charge.
M&L for replacement of condensor fan motor mounting stand made out of mild steel sheet 3 mm thick size 400x150 mm and refixing on the existing base, complete all as specified and as directed by Engineer-in-Charge.
M&L for replacement of foundation stand of water cooler fabricated out of angle iron 25x25x3 mm 1600 mm in length incl. Welding and necessary fitting with patch work to bottom portion of 20 gauge MS sheet size 40x15 cm all as directed.
Supply and fix CP lift cock, 15mm bore made of brass self closing vertical type made of brass nickle chromium plated with CP adaptor and nipple, complete all as specified and as directed. Make : Mayor/ C-Sons/ G-Sons
Supply and fix CP push cock, 15mm bore made of brass self closing horizontal type made of brass nickle chromium plated with CP adaptor and nipple, complete all as specified and as directed. Make : Mayor/ C-Sons/ G-Sons
M&L for permanent type sticker of size 150x300 mm having following details in letters not exceeding 25 mm, complete all as specified and as directed. (i) Machine Srl No._____________ (ii) MES No______________ (iii) Date set to work.____________ (iv) PRB Page No ______________. (v) Location__________________
M&L for painting to water cooler of storage cap. 150/120/80 Ltrs spray painting with two coats of synthetic enamelled paint (first quality) including preparation of surface, complete all as specified and as directed. Make : ASIAN/ BERGER/ NEROLAC .
M&L for replacement of deteriorated glass wool and tar felt of water cooler complete including fixing etc. of any cap / make, complete all as specified and as directed.
M&L for repair to storage water tank of cooler of cooling cap 40 Ltr/hour by soldering / brazing to prevent leakage spots incl. cleaning of water tank and testing complete (NOTE : work is to be carried out in existing position as and where machine in army area)
M&L for repair to water tank cooler of cooling cap 60 Ltr/hour cap. by soldering, brazing to prevent leakage spots incl. cleaning of water tank and testing complete (NOTE : work is to be carried out in existing positio as and where machine lyes in army area )
M&L for repair to water tank of water cooler of cap. 150 ltrs/hrs, by soldering / brazing to prervent leakage spots incl. cleaning of water tank and testing complete (NOTE : Repairing to be done by the contractor at various location of units).
M&L for replacement of starting capacitor 40-60 Mfd oil filled 240 volt AC Supply, complete all as specified and as directed. Make : Asian/ Atlas/ Epcos/ SPAN/ Sharda Texla
M&L for replacement of starting capacitor 60-80 Mfd oil filled 240 volt AC Supply, complete all as specified and as directed. Make : Asian/ Atlas/ Epcos/ SPAN/ Sharda Texla
M&L for replacement of running capacitor of 15 Mfd oil filled, complete all as specified and as directed. Make : Asian/ Atlas/ Epcos/ SPAN/ Sharda Texla
M&L for replacement of running capacitor of 10 Mfd oil filled, complete all as specified and as directed. Make : Asian/ Atlas/ Epcos/ SPAN/ Sharda
M&L for replacement of running capacitor of 2.5 Mfd oil filled, complete all as specified and as directed. Make : Asian/ Atlas/ Epcos/ SPAN
S&F in relacement PVC float valve 15mm bore with PVC float, ball (ISI marked) complete with check nut/socket/GI nipple, complete all as specified and as directed by Engineer-in-Charge. Make : PRAYAG/ POLYTUFF
M&L for replacement of water cooler side panel with 20 gauge MS sheet as per sample incl. necessary screws/nuts/bolts/washers etc for 40/60/150 Ltrs/hour cap, complete all as specified and as directed by Engineer-in-Charge.
M&L for pressurising of system & detecting of leakages in system , flushing , replacement of copper filter and gas (using maffron M- 134 gas ), oil complete incl testing and commissioning of water cooler having cooling Capacity 40 Ltrs per hour of any make, complete all as specified and as directed by Engineer-in-Charge.
M&L for pressurising of system & detecting of leakages in system , flushing , replacement of copper filter and Gas (using maffron gas - M-134 ) charging , oil complete incl testing and commissioning of water cooler having cooling Capacity 60 Ltrs per hour of any make, complete all as specified and as directed by Engineer-in-Charge.
M&L for pressurising of system & detecting of leakages in system , flushing , replacement of copper filter and gas charging of Gas (using maffron gas M-134 ), oil complete incl testing and commissioning of water cooler having cooling Capacity 100 Ltrs per hour of any make, complete all as specified and as directed by Engineer-in-Charge.
M&L for replacement of aluminium fan blade for condenser fan motor (as per sample) suitable for water cooler having cooling capacity 40 Ltr/hr water cooler, complete all as specified and as directed by Engineer-in-Charge.
M&L for replacement of aluminium fan blade for condenser fan motor (as per sample) suitable for water cooler having cooling capacity 60/150 Ltr/hrs water cooler, complete all as specified and as directed by Engineer-in-Charge.
M&L for replacement of condenser unit complete suitable for 40 Ltr/hrs cap. Water cooler including gas charging flushing out the system brazing, welding and jointing the suction reed and discharge reed, complete all as specified and as directed by Engineer-in-Charge.
M&L for replacement of condenser unit complete suitable for 60 to 100 Ltr/hrs cap. Water cooler including gas chargin flushing out the system brazing, welding and jointing the suction reed and discharge reed, complete all as specified and as directed by Engineer-in-Charge.
M&L for replacement of condenser unit complete suitable for 150 Ltr/hrs cap. Water cooler including gas charging flushing out the system brazing, welding and jointing the suction reed and discharge reed, complete all as specified and as directed by Engineer-in-Charge.
M&L for replacement of PVC insulated and PVC sheathed flexible cable , multistranded copper conductor 3 core 48/0.20 cross sectional area superior quality, complete all as specified and as directed by Engineer-in-Charge. Make : Plaza/ Finolex/ Polycab
(B) Refrigerators/ Deep freezer:- M&L for checking of Refrigerators/ Deepfreezer of any make / capacity in location and position at any site in Army Area Jodhpur including necessary servicing ie: electrical connection /wiring, cleaning , door gasket cleaning evaporator cleaning and testing for proper functioning of refrigerators/ deep freezer, complete all as specified and as directed by Engineer-in-Charge. ( The rates are deemed to be included for maintaining complete and proper record of machine ie: make with srl no ,SM no. capacity, date of servicing , user signature after servicing , concerned JEs signature all as directed by engineer incharge )
M&L for replacement of unserviceable hermetically sealed compressor of Deep freezer 605 Ltr Capacity with fresh new uncut sealed unit compressor including suitable relay and over load with new sealed unit as per the company scheme supplied by the manufacturer complete including flushing out system, checking and rectfication of leakage, gas charging, complete all as specified and as directed by Engineer-in-Charge. NOTE : (i) The rate quoted by the contractor shall be inclusive of all charges ie: test certificate and necessary guarantee period as per manufacturer company. (ii) The new unit will be purchased from authorised dealer only as per existing make and model. Make : Whirlpool/ LG/ Godrej
M&L for replacement of unserviceable hermetically sealed compressor of Deep freezer 405 Ltr Capacity with fresh new uncut sealed unit compressor including suitable relay and over load with new sealed unit as per the company scheme supplied by the manufacturer complete including flushing out system, checking and rectfication of leakage, gas charging, complete all as specified and as directed by Engineer-in-Charge. NOTE : (i) The rate quoted by the contractor shall be inclusive of all charges ie: test certificate and necessary guarantee period as per manufacturer company. (ii) The new unit will be purchased from authorised dealer only as per existing make and model. Make : Whirlpool/ LG/ Godrej
M&L for replacement of unserviceable hermetically sealed compressor of Refrigerator / deep freezer 310/280 Ltr Capacity with fresh new uncut sealed unit compressor including suitable relay and over load with new sealed unit as per the company scheme supplied by the manufacturer complete including flushing out system, checking and rectfication of leakage, gas charging, complete all as specified and as directed by Engineer-in-Charge. NOTE : (i) The rate quoted by the contractor shall be inclusive of all charges ie: test certificate and necessary guarantee period as per manufacturer company. (ii) The new unit will be purchased from authorised dealer only as per existing make and model. Make : Whirlpool/ LG/ Godrej
All as per item No. 56 above but for 165/170/180 /220 Ltr capacity refrigerator, complete all as specified and as directed by Engineer-in-Charge. Make : Whirlpool/ LG/ Godrej
M&L for replacement of relay suitable for 286/310/320 Litres cap. Refrigerator, complete all as specified and as directed by Engineer-in-Charge. Make : Renutrol/ Shriram/ Annapurna/ KLIXON
All as per item No 58 but cap 165/220 Ltrs Refrigerator, complete all as specified and as directed.
M&L of replacement of thermostat automatic defrost with knob suitable for 165 to 310 liters cap refrigerator, complete all as specified and as directed by Engineer-in-Charge. Make : Annapurana/ Indofos
M&L for replacement of door gasket of best quality complete suitable for 286/310 litres cap. Refrigerator as per manufacturer's instruction and as directed by Engr-in-Charge.
All as per item No 61.00 above but for 165/220 Ltrs Cap, complete all as specified and as directed.
S&F bulb for pin/screw type, 230 Volts suitable up to310 Ltrs Cap. Refrigerator as in replacement, complete all as specified and as directed by Engineer-in-Charge.
M&L for replacement of freezer door incl. necessary door springs, screws etc for 286/310 Ltrs Cap. Refrigerator, complete all as specified and as directed by Engineer-in-Charge.
All as per ser item No 64 above but for 165/220 Ltrs cap. Refrigerator.
M&L for replacement of door lock with keys-2 nos. for any capacity of refrigerator as per sample approved by Engr-in-Charge.
M&L for replacement of PVC asscessories suitable for 286/310 Ltrs Cap. Refrigerator complete of matching size, complete all as specified and as directed by Engineer-in-Charge.
M&L for replacement of PVC asscessories suitable for 165/170/180 ltrs capacity refrigerator complete of matching colour, complete all as specified and as directed by Engineer-in-Charge.
M&L for patch work/ door repair (in the outer body of water cooler/refrigerator/Deep freezer with 20 gauge PGI sheet upto required length/width &hight incl necessary welding/brazing etc, complete all as specified and as directed by Engineer-in-Charge.
M&L for patch work/ repair of bottom of deep freezer(capacity upto 320/405 ltr ) with 22/24 gauge PGI sheet upto upto required length/width &hight incl necessary welding/brazing etc, complete all as specified and as directed by Engineer-in-Charge.
M&L for replacement of refrigerator door handle of 165 to 320 Ltrs Cap. Of any make and model, complete all as specified and as directed by Engineer-in-Charge.
M&L for repairing to bottom/ foundation of refrigerator any cap. With 20 gauge PGI sheet, angle iron frame made out of 25 X 25 X3 mm angle and incl necessary welding work, complete all as specified and as directed by Engineer-in-Charge.
M&L for replacement of evaporator ( Freezer ) assy with door and fixing brackets complete with screw, jointing of tubes etc and testing of cap220 to 320 Ltrs refrigerator (any make), complete all as specified and as directed by Engineer-in-Charge.
All as per ser item No 74 above but of capacity 165/180 Ltr refrigerator.
M&L for replacement of condensor unit of refrigerator cap.280/ 286/310/320 Ltrs of any make incl jointing of tubes and testing etc, complete (gas charging will be measure and paid under relevant item separately), complete all as specified and as directed by Engineer-in-Charge.
All as per ser item No 75 above but for 165/180/220 ltrs capacity refrigerator.
M&L for leakage detection including flushing out system,pressurising,including gas charging(as per existing) suitable for 286/310 ltrs, complete all as specified and as directed by Engineer-in-Charge.
M&L for leakage detection including flushing out system,pressurising,including gas charging (as per existing ) suitable upto 220 ltrs, complete all as specified and as directed by Engineer-in-Charge.
Supply only refrigerant gas R22/R134/R200 or any other variant as per existing, complete all as specified and as directed. Note : (i) The gas is to be supplied in cylinder duly sealed by manufaturer/ factory sealed with proper PVs and other documents. Make : Maffron/ Floron
M&L for permanent type sticker of size 150x300 mm having following details in letters not exceeding 25 mm, complete all as specified and as directed by Engineer-in-Charge. (i) Machine Srl No._______________ (ii) MES No______________ (iii) Date set to work.___________ (iv) PRB Page No ______________ (v) Location__________________
Supply and replacement of metal clad enclosure complete with plug and socket duly fitted with MCB SP10 Amp, complete all as specified and as directed by Engineer-in-Charge. Make : ABB/ LEGRAND
M&L for sub main /Circuit wiring with 1.5 Sqmm copper conductor cable 1100 volts grade conforming to relevant IS and ISI Marke including same size of earth wire and taking out old unserviceable sub main wiring including Making good to distrubed surface, complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of condensor fan motor complete for deep freezer cap.310 to 405 ltrs. In existing location and position as per sample, complete all as specified and as directed by Engineer-in-Charge.
M&L for replacement of timer frost free refrigerator as per approved sample, complete all as specified and as directed by Engineer-in-Charge.
M&L for replacement of fan motor double door frost free refrigerator as per approved sample, complete all as specified and as directed by Engineer-in-Charge.
Supply and replacement of PCB (including inverter type) as per existing suitable for 220 to 320 Ltrs refrigerator/Deep Freezer, complete all as specified and as directed by Engineer-in-Charge.
Taking down carefully automatic voltage stablilzer electronic type of cap up to 3 KVA of any make including replacement of PCB and transformer complete kit reassembling and testing etc., complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of 3 Pin Plug Top 16 Amps (ISI Marked) 230 Volts, complete all as specified and as directed by Engineer-in-Charge. Make : Anchor/ Havells/ Legrand
S&F in replacement of 3 Pin Plug Top 06Amps (ISI Marked) 230 Volts, complete all as specified and as directed by Engineer-in-Charge. Make : Anchor/ Havells/ Legrand
S&F in replacement of PVC Connection pipe (ISI Marked) 300/450mm long heavy duty, complete all as specified and as directed by Engineer-in-Charge.
M&L for replacement of PVC stop cock (ISI Marked) heavy duty, complete all as specified and as directed by Engineer-in-Charge.
(C) DESERT COOLERS:- M&L for (in existing location and position) taking out and refixing after repairs, including rewinding of Desert Cooler fan motor of any make, 3 speed,1400 RPM of capacity 1/5 HP with super enameled copper winding wire of appropriate size ( as per existing), complete all as specified and as directed by Engineer-in-Charge. Make of winding wire : DEVIDAYAL/ CHETAK.
S&F in replacement of bush for cooler fan motor as per existing sample, complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of shaft for cooler fan motor as per existing sample, complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of oil filled capacitor 4.00 MFD for desert cooler fan motor, complete all as specified and as directed by Engineer-in-Charge. Make : EPCOS/ SHARDA/ KENSTAR
M&L for replacement of bottom tank and top (in existing location and position) of approx size - 750 X 750 X 200 mm ( as per existing ) for Desert Cooler made out of 18 gauge PGI sheet with and including two coats of synthetic enamel painting over one coat of red oxide primer on the new surfaces to match with existing surface outside and inside surface with approved quality paint including leakage testing, complete all as specified and as directed by Engineer-in-Charge.
M&L for ( taking out and refixing in ) replacement of front grill ( as per existing )( horizontal and vertical members moveable) of the Desert Cooler made out of 20 gauge PGI sheet with Name plate, complete all as specified and as directed by Engineer-in-Charge.
M&L for replacement of side supporting columns to be fabricated out of 20 gauge PGI sheet of size 80x80x800 mm with and including necessary nut, bolts etc., complete all as specified and as directed by Engineer-in-Charge.
M&L for replacement of side/rear panel made out of 22 gauge PGI Sheet with suitable handles with and including two coats of synthetic enamel paint over one coat of red oxide primer to match with the existing desert cooler, complete all as specified and as directed by Engineer-in-Charge.
M&L for painting to old steel surfaces of Desert cooler capacity up to 5000 Cft with one coat of synthetic enamel spray paint hammer tone paint of approved colour over one coat of red oxide primer on external surface and one coat of anti corrosive black paint inside the Body tank and side grills over a coat of red oxide primer complete including scraping/rubbing with wire brush on old surface of Desert cooler and writing of MES No etc complete at site or at E/M store yard, complete all as specified and as directed by Engineer-in-Charge.
M&L for replacement of Desert Cooler fan motor of capacity 1/5 HP three speed, 1400 RPM single phase with aluminium fan blade, bracket supporting stand, complete all as specified and as directed by Engineer-in-Charge. Make : Crompton/ Symphony/ Cool Home/ Kenstar
M&L for replacement of submersible pump of discharge head 2.5 Mtr 220-240 Volts AC Supply single phase 40 watt, complete all as specified and as directed by Engineer-in-Charge. MAKE : CG/ Symohony/ Coolhome
M&L for replacement of Wood wool pad for Desert Cooler of size 500 x 550 x30 mm (set of three pads) superior quality including binding properly with GI wire of 16 SWG with grill, complete all as specified and as directed by Engineer-in-Charge.
M&L for replacement of MS weld wire mesh having apparture size 25 mm and fitted in side grills/rear, complete all as specified and as directed by Engineer-in-Charge.
M&L for replacement of Wood wool pad Heavy duty for Desert Cooler of suitable size (set of three pads) superior quality including binding properly with GI wire of 16 SWG with grill, complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of PVC insulated and PVC sheathed cable copper conductor 3 core 1.0 Sqmm cross sectional area superior quality, complete all as specified and as directed by Engineer-in-Charge. Make : Polycab/ Havells
M&L for replacement of PVC water distribution cup of one inlet and 3 outlets fixed with MS nuts and bolts complete (as per sample), complete all as specified and as directed by Engineer-in-Charge.
M&L for replacement of PVC elbow suitable for desert cooler (as per sample, complete all as specified and as directed by Engineer-in-Charge.
M&L for replacement of PVC pipe 15 mm dia heavy duty for Desert Cooler Pump, complete all as specified and as directed by Engineer-in-Charge.
M&L for painting to desert cooler stand with two coats of synthetic enameled paint of approved colour over a coat of red oxide primer including preparation of old surfaces, complete all as specified and as directed by Engineer-in-Charge.
M&L for replacement of 3 pin plug top cap 5 Amp AC 240 Volts 50 Hz, complete all as specified and as directed by Engineer-in-Charge. Make : Anchor/ Havells/ Legrand
M&L for replacement of 3 pin plug top cap 15 Amp single phase AC Supply 240 Volts, complete all as specified and as directed by Engineer-in-Charge. Make : Anchor/ Havells/ Legrand
M&L for replacement of motor fixing ring (not less than 25 mm width ) for desert cooler eight screw / clip type(as per sample), complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of 4mm thick ply (ISI marked) duly making hole for fixing single cooler in window of approximate size 1.5X1.2 mtrs for cooler grill approximate 24"X24" to be replaced in existing location and position in army area, complete all as specified and as directed by Engineer-in-Charge.
M&L for taking down desert cooler installed at ground floor safely , including cleaning inside , outside , motor oilng sevicing and pump servicing including putting up in same location and position, complete all as directed. NOTE: Any replacement of spare shall be measured and paid separately under respective item of schedule 'A'.
M&L for taking down desert cooler installed at first floor safely , including cleaning inside , outside , motor oilng sevicing and pump servicing including putting up in same location and position, complete all as directed. NOTE: Spare parts shall be measured and paid separately under respective item of BOQ.
M&L for taking down desert cooler installed at second floor safely , including cleaning inside , outside , motor oilng sevicing and pump servicing including putting up in same location and position, complete all as directed. NOTE: Spare parts shall be measured and paid separately under respective item of BOQ.
M&L for stand flush to wall for desert cooler fabricated out of MS angle iron 40 x 40 x 6 mm , 1.2 meter long bend to shape as top size 600 x 600 mm duly welded with two members to tie vertical support , including painting two coats of synthetic enamelled paint over a coat of red oxide primer including M&L for steel rack bolt / fastner 100 mm long 12 mm dia - 4 Nos for fixing stand, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in replacement PTMT stop cock 15 mm dia high pressure screwed for iron pipe, complete all as specified and as directed by Engineer-in-Charge. Make : PRAYAG/ POLYTUFF
Supply and fix in replacement PTMT Ball valves 15 mm dia high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe, complete all as specified and as directed by Engineer-in-Charge. Make : PRAYAG/ POLYTUFF
Supply and fix plug and socket for metal clad box of current carrying capacity of 20Amp, complete all as specified and as directed.
M&L for wiring for circuit / sub main wiring alongwith earth wire with the following sizes of FR LSH PVC insulated , multistranded copper conductor cable ,( 2 X 1.5 Sq mm + 1X 1.5 Sqmm ), single core drawn in and including PVC casing capping 25 mm width , to be fixed on surface/ ceiling, complete all as specified and as directed by Engineer-in-Charge.
Supply and replace PVC moulded box of switch socket combination of cap - 15 Amp, complete all as specified and as directed by Engineer-in-Charge. Make : ANCHOR/ LEGRAND
Geyser & Solar water heater:- M&L for attending daily complaints in repairs and maintenance of geysers, Solar water heater of any capacity/ any make lodged by the users complete to make serviceable condition with skilled electrician (Geyser & Solar Water Heater) like Dismantling electric and water connection of the geyser, taking down from its position on ground, dismantling geyser complete such as removing tank from its outer body , removing apparatus plate from the tank, descaling the geyser inner tank and apparatus plate complete, testing its thermostate, element , and tank from leakage, reassembling the geyser, replacement of unserviceable parts such as heating element, thermostat, indication lamp, plug top , three core wire, rubber gasket, inner tank, split plate, outer bottom cover, apparatus plate if required (Spares will be paid under relevant item of the Sch) testing the geyser and installation of the geyser into its original position and connecting all electric and water supply connection, complete all as specified and as directed by Engineer-in-Charge. Note 1 : Complaint attend Day to Day as well as required bases. (a) The minor complaints (non functioning of geyser, replacement of thermostat, indicators, flexible wire, bib cock, stop cock, PVC connections, plug top, MCB, Socket, ) should be competed with in 24 hrs by deploying required manpower. (b) Major complaints like leakage of tank, relocation of geyser, glass wool replacement, and major assembly replacement should be completed with in 48 hrs. (c) The rates quoted for the item shall be deemed to include the cost of labour for replacement of any stores whenever required. The materials will be measured and paid as `Supply only' under relevant items of this schedule.
Taking down of defective geyser of any capacity from site transportation to E/M store yard for repair, strip opening for complete overhauling and ascertaining the repair/replacement (spare part shall be measured and paid seperately under respective items) & re-assembling the geyser after repair/replacement and including connect with existing electric & water connection, testing, complete all as directed.
Disconnecting of electric and water supply connection of geyser for supply and replacement of brass chromium in-door assembly(shyphon assy) 6/9 hole for 50 Ltrs Geyser including connect with existing connections and testing complete.
Disconnecting of electric and water supply connection of geyser for supply and replacement of brass chromium in-door assembly(shyphon assy) 6/9 hole for 25 Ltrs Geyser including connect with existing connections and testing, complete all as specified and as directed by Engineer-in-Charge.
M&L for taking down and S&F15 mm bore GI tubing medium grade with and including all new fittings Make : TATA/JINDAL./PRAKASH SURYA (ISI Marked) ( Note : Rates shall deemed to be included for making holes/nitch, cutting chases for replacement of pipe and making good distrubed surface to match with existing surface and finish, complete all as directed.
S&F in replacement fancy type Bib tap 15mm bore cast copper alloy high pressure,screwed for iron pipe, complete all as specified and as directed by Engineer-in-Charge. Make : JAGUAR/ MARC/ NMC.
S&F in replacement fancy type stop valves 15mm bore cast copper alloy high pressure, both ends screwed, complete all as specified and as directed by Engineer-in-Charge. Make : JAGUAR/ MARC/ NMC.
S&F in replacement of PVC connection heavy duty, nylon braided, suitable for hot water, with brass alloy chromium plated nuts and nylon washers complete of size15mm bore and 450 mm long, complete all as specified and as directed by Engineer-in-Charge.
All as per srl item No 131.00 here-in-above but for 600mm long.
S&F of CP copper pipe, suitable for hot water, with brass alloy chromium plated nuts and nylon washers complete of size15mm bore and x 60 cms long, complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of in repairs SP metal clad plug outlet with sheet metal enclosure complete with plug top and MCB SPN-20 Amp, complete all as specified and as directed by Engineer-in-Charge. Make : LEGRAND/ABB/Schneider
S&F in replacement of heating element (ISI Marked) of suitable type as per existing including rubber ring clamping screws etc complete of 1.5KW, complete all as specified and as directed by Engineer-in-Charge. Make : BAJAJ/ VENUS/ THEETA
All as per srl item No 135.00 here-in-above but 2.00 KW
S&F in replacement of thermostat ISI marked for geyser as per existing of range 15-65 degree temperature, complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of steel vessel (tank)of geyser capacity 25 ltrs as per existing type of, complete all as specified and as directed by Engineer-in-Charge.
ditto- all as per srl item No 138.00 here-in-above but capacity 50 ltrs.
S&F in replacement of vacuum safety valve of suitable size on inlet side of geyser, complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of brass chromium plated horizontal/vertical non return valve of size 15mm bore (ISI Marked) on inlet side of Geyser, complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of pressure release valve of size 15mm bore, complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of brass nut fusible plug suitable for Geysers, complete all as specified and as directed by Engineer-in-Charge.
M&L for drilling hole in wall, grouting fastner nut and bolt not less than 100 mm long for holding geyser upto 50 ltrs in wall including making good and matching existing surface and finish, complete all as specified and as directed by Engineer-in-Charge.
M&L for replacement of indicating lamp of red and green colour, for Geysers including connecting, complete all as specified and as directed by Engineer-in-Charge.
M&L for replacement of bottom split inspection cover for geyser capacity - 25 ltrs. of any make, complete all as specified and as directed by Engineer-in-Charge.
Supply and replacement of bottom split inspection cover for geyser capacity - 50 ltrs. of any make, complete all as specified and as directed by Engineer-in-Charge.
Supply and replacement of outer body made of ms/ss sheet for geyser capacity - 25 ltrs. of any make, complete all as specified and as directed by Engineer-in-Charge.
Supply and replacement of outer body made of ms/ss sheet for geyser capacity - 50 ltrs. of any make, complete all as specified and as directed by Engineer-in-Charge.
Supply & replaced Rubber Gasket as per site requirement for 25/50 ltr geyser, complete all as specified and as directed by Engineer-in-Charge.
M&L for scrapping old paint and applying spray painting one coat of synthetic enamelled paint of approved quality including writing MES No. / building no. in letters of size 40 mm width. For geyser cap. - 25 ltrs of any make/type, complete all as specified and as directed by Engineer-in-Charge. (NOTE : Rates shall deemed to be included for taking down Geyser in location and position , disconnecting and reconnecting electrical / water connection all as directed)
M & L for scrapping old paint and applying spray painting one coat of synthetic enamelled paint of approved quality including writing MES No/ building no. in letters of size 40 mm width. For geyser cap. - 50 ltrs of any make./type, complete all as specified and as directed by Engineer-in-Charge. (NOTE : Rates shall deemed to be included for taking down geyser in location and position , disconnecting and reconnecting electrical / water connection all as directed)
M&L for replacement of GLASS WOOL in repairs for Geysers of any capacity, complete all as specified and as directed by Engineer-in-Charge.
Supply and replacement of MCB SP 20 Amp, 10KA, complete all as specified and as directed by Engineer-in-Charge. Make : Legrand/ ABB/ HPL.
Supply and replacement of three pin top 20 Amp, complete all as specified and as directed by Engineer-in-Charge. MAKE : HAVELLS/ LEGRAND.
Supply and replacement of metal clad plug socket 3 pin 20 Amp, complete all as specified and as directed by Engineer-in-Charge. MAKE : HAVELLS/ LEGRAND.
Supply and replacement of metal clad plug Topt 3 pin 20 Amp, complete all as specified and as directed by Engineer-in-Charge. MAKE : HAVELLS/ LEGRAND.
Supply and replace FT socket three pin 16/15 Amp, complete all as specified and as directed by Engineer-in-Charge. MAKE : ANCHOR/ HAVELLS
Supply and replace FT switch 16/15 Amp, complete all as specified and as directed by Engineer-in-Charge. MAKE : ANCHOR/ HAVELLS
"Supply only" PVC insulated copper conductor 1100 volts grade circular cable of size 2.5 sqmm (50/.025) 3 core, complete all as specified and as directed by Engineer-in-Charge. Make : Polycab/ Havells
"Supply only" Modular socket 03 pin 16 Amps, complete all as specified and as directed by Engineer-in-Charge. Make : Legrand/ ABB
"Supply only" Modular Switch single pole, one way 16 amp polycorbonate body, complete all as specified and as directed by Engineer-in-Charge. Make : Legrand/ ABB
M&L for welding/brazing steel/copper vessel (storage water tank of capacity 25/50 ltrs) including pressure testing and leakage testing, complete all as specified and as directed by Engineer-in-Charge.
M&L for cheking of Solar water heater system of any capacity and make installed at ARMY AREA Jodhpur, complete all as specified and as directed by Engineer-in-Charge.
De-scaling & servicing of Solar Water Heater system of any capacity and any makeincluding re-insulation and making fit for smoth function, complete all as specified and as directed by Engineer-in-Charge.
M&L for heating element of cap 3/5 KW ISI Mark as per existing panel length & width, complete all as specified and as directed by Engineer-in-Charge. Make : Bajaj/ Venus/ Theeta
M&L for thermo stat ISI Mark Suitable for existing panel, complete all as specified and as directed by Engineer-in-Charge.
M&L for Repair to damaged panel tubing with gas welding of Solar Water Heater of any capacity/any make, complete all as specified and as directed by Engineer-in-Charge.
M&L for Providing accessories such as nuts,bolts rubber angle iron piece with welding other clading etc., complete all as specified and as directed by Engineer-in-Charge.
Dismantling and taking down unserviceable pressure pumps and motor of cap not more than 2 HP of any capacity and description and refixing to the position after servicing and minor repairs as refilling of pressure replacement of auto cut switch etc the job include rewinding of motor, complete all as specified and as directed by Engineer-in-Charge.
M&L sub main wiring with 2 Single core PVC insulated unsheathed cable 1100 Volts grade heavy duty FRLSH copper conductor multistaranded of size 6 Sq.mm. (nominal area) drawing in and including 20 mm. dia PVC concealed conduit and conduit accessories and fittings. Including one single core green colour PVC. Insulated unsheathed cable aluminium conductor multistranded of size 6 Sq. mm. as earth wire upto common earth and connected to earth dolly including taking down old one, complete all as specified and as directed by Engineer-in-Charge.
"Supply only" Stop Cock CP brass 15 mm bore screwed down with crutch or butterfly handle , complete all as specified and as directed by Engineer-in-Charge.
"Supply only" bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm- 90gms/20mm- 125gms) of Size 15mm, complete all as specified and as directed by Engineer-in-Charge.
M&L for Laying of GI tubing medium grade laid in floors/walls/roof including all necessory fittings of size 15mm dia, complete all as specified and as directed by Engineer-in-Charge.
M&L for insulation of GI Pipe with PUF slab 30mm thick with and including applying bituminus compound and GI Cladding with GI Sheet complete of Size 20 mm dia, complete all as specified and as directed by Engineer-in-Charge.
M&L for Laying of GI tubing med grade on floors/walls/roof including all necessory fittings of size 20mm dia, complete all as specified and as directed by Engineer-in-Charge.
M&L for Laying of CPVC as per IS:15778 tubing SDR11 on floors/walls/roof including all necessory fittings of size 25mm dia, complete all as specified and as directed by Engineer-in-Charge.
S&F male Brass threaded adopter 20mm dia, complete all as specified and as directed by Engineer-in-Charge.
M&L for replacement of assembly bottom cover (Inspection cover) split type made of iron sheet duly painted with two coats of synthetic enemel paint over one of red oxide primer, complete all as specified and as directed by Engineer-in-Charge.
M&L for replacement of bottom cover for outer body made out of MS sheet of same guage and size duly painted with two coats of synthetic enamel paint of existing geyser colour over one coat of red-oxide primer, complete all as specified and as directed by Engineer-in-Charge.
M&L for Angle Iron 25x25x4mm supporting for Solar panel including cutting, grouting, painting all as specified. Fe 410 -W Gde- E- 250) quality- A, complete all as specified and as directed by Engineer-in-Charge.
M&L for PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) for fixing of stands of solar plates, hot water tank etc., complete all as specified and as directed by Engineer-in-Charge.
Repair, rewinding of submersible pump monoblock type of capacity upto 3 HP, single or three phase, any make incl connection, testing, complete all as specified and as directed by Engineer-in-Charge. Make : Devidayal/ Chetak.
M&L for Repair, rewinding of submersible pump monoblock type of capacity upto 7.5 HP, single or three phase, any make incl connection, testing, complete all as specified and as directed by Engineer-in-Charge. Make : Devidayal/ Chetak.
Replacement of spare parts of submersible pump monoblock type of capacity upto 7.5 HP (i.e Water pump lock, thread cap, motor fan, pump tube pipe, wire assembly cap, pump valve assembly, plastic pump handle and capacitor cover) incl connection, testing, complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of direct on line submersible pump stater of capacity 5 HP, 3 Phase, 415 Volt, with and incl connection, testing complete all as specified and directed make Kirloskar/ crompton
NOTE:- (i)- Quantities are clubbed in BOQ for Two Jobs. For which details of quanitity as following. (a) CPP Srl No. 39 - BOQ Item No. 02 to Item No. 124 (b) CPP Sel No. 41 - BOQ Item No. 125 to Item No. 188. (ii)- The contract sum shall be arrived at after duducting amount of schedule of "Credit" from the Total quoted amount
LOKESH ELECTRICAL WORKS CONTRACTOR
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .