Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.1 LAccepted-AOC HOUSE NO 599 D SURYA NAGAR PHASE II SECTOR 91 FARIDABAD 121013 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121013 | L1 | Accepted-AOC AOC | |
| 2 | L2₹17.9 L+₹2.4 L (15.5%)Rejected-Finance 50 SARASWATI VIHAR SINGHAWALA AMBALA CITY | AMBALA CITY | L2 | Rejected-Finance Rejected being | |
| 3 | L3₹21.2 L+₹5.7 L (36.8%)Rejected-Finance 186 GANDHI MARKET AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L3 | Rejected-Finance Rejected being |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
18 Jul 2020, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (NORTH) AMBALA CANTT
GE (NORTH) AMBALA CANTT
CA NO GE(N)/AMB-39(P)/2020-21 REPAIR/ REPLACEMENT OF DISTRIBUTION BOARDS WITH CONNECTED ITEMS AND OTHER MISC WORKS IN AREA - I MD ACCN OF SECTOR A, AGE E AND M (NORTH), AMBALA CANTT
2020_MES_347103_1
GE(N)Amb-39(P)/2020-21
Open Tender
Civil Works
Item Rate
GE (NORTH) AMBALA CANTT
As per Tender Documents
7 documents required · 7 mandatory
₹500
GE (NORTH) AMBALA CANTT
₹60,000
Yes
31 Jul 2020
17 Jun 2020
20 Jul 2020
17 Jun 2020
18 Jul 2020
3 Jul 2020
18 Jun 2020 - 2 Jul 2020
60 days
Amount
Supply and fix sheet metal MCB DBs 8 way with 200 Amps rated bus bar single pole and neutral IP-43, double door fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, including making smooth the disturbed surface after removing old Unserviceable MCB DB complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix sheet metal enclosure Vertical triple pole & neutral (VTPN) with TPN MCCB 125 Amp for 415 volts 4 way with 200 Amp rated bus bar flush /surface mounting double door duly grouted in solid block wall or on wooden board in and including lugs/thimbles duly crimped for connection including making smooth the disturbed after removing old Unserviceable MCB DB surface complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix MCB SP 6-32 Amps, 240 volt, 10 KA 'C' curve including removing old Unserviceable MCBs complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix RCBO 40 Amps 2 Pole, 2 module 100 mA (HI immunity) sensitivity 230 volts 50 Hz, including removing old Unserviceable RCBO complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix over voltage release 230 V, single phase in one module, including removing old Unserviceable complete all as specified and as directed by the Engineer-in-Charge.
S&laying sub main wiring with two run of 6 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volts grade ISI marked with multi stranded copper conductor and one run of 6 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked multi stranded copper conductor as earth continuty conductor connected to common earth dolly including concealed on wall and surface on ceiling in PVC conduit medium grade ISI marked of adequate size for housing the wires complete all as specified including taking out of old U/s sub main wiring of any size . Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. (ii) Three runs of cable and one run of PVC conduit shall be measured and paid as one unit length.
All as per srl item No 1.06 here-in-before but submain wiring with 10 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volts grade ISI marked with multi stranded copper conductor cable.
Supply and laying or fixing or passing through pipe 1100 volts grade heavy duty 2 core, 6 sq mm cable with PVC insulated aluminium conductor multi stranded served with an inner sheathing of PVC tape and overall PVC sheathed in service connection, including disconnecting and taking down old U/S existing cable complete all as specified and as directed by the Engineer-in-Charge.
Supply and laying or fixing or passing through pipe 1100 volts grade heavy duty 2 core, 10 sq mm cable with PVC insulated aluminium conductor multi stranded served with an inner sheathing of PVC tape and overall PVC sheathed in service connection, including disconnecting and taking down old U/S existing cable complete all as specified and as directed by the Engineer-in-Charge.
Supply and laying XLPE insulated, armoured heavy duty electric cable 25 sqmm 3.5 core with multi stranded aluminium conductor, 1100 volts grade, including disconnecting and taking down old U/S existing cable complete all as specified and as directed by the Engineer-in-Charge.
Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter deep and getting out in any type of soil complete all as specified and directed by the Engr-in-Charge
Returning, Filling in excavated soils including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed by the Engineer-in-Charge.
M & L for dry sand as cushioning to cable 8 cm before laying cable in trenches and 15 cm after laying the cable and compacting, complete all as specified and as directed by the Engineer-in-Charge.
Supply and laying well burnt bricks class-B laid flat to cover the cable width equal to the length of cable and abutting each other for protection of cables complete all as specified and as directed by the Engineer-in-Charge.
S&F light grade GI Tubing of size 40 mm dia for cable protection and fixed with clamp to pole and wall with nut bolts, including disconnecting and taking down existing pipe and removing complete all as specified and as directed by the Engineer-in-Charge.
M&L for earthing complete (in repairs) with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth plate not less than 2.25 mtr below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to GI wire 4 mm dia by means of bolts, nuts, check nuts and washers all as shown in electrical plate No 5 connected to earthing test point and testing on completion all as specified and directed. Note :- Cost of excavation and earth work, PCC pit, PCC cover, funnel, watering pipe, wire mesh, charcoal dust, common salt and earth lead up to 7.5 mtr long shall be deemed included in the unit rate for earthing complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix sheet metal MCB DBs 12 way with 200 Amps rated bus bar single pole and neutral IP-43, double door fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, necessary PCC work and making smooth the disturbed surface after removing old Unserviceable MCB DB complete all as specified and as directed by the Engineer-in-Charge.
R N Enterprises
M/S Sonu Traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .