Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.7 LAdmitted-Finance 1 2 VELLAPPARA PALLISSERY HOUSE PUNNAYURKULAM POST MARPADI MALAPPURAM | MARPADI | MALAPPURAM | KERALA | L1 | Admitted-Finance | |
| 2 | L2₹19.3 L+₹65,211.48 (3.49%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹20.0 L+₹1.4 L (7.24%)Admitted-Finance | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | RAFEEQUE V.P. L1 | SP BUISINESS ASSOCIATES L2 | EC ENGINEERING L3 |
|---|---|---|---|---|---|---|
| 1.00CIVIL WORKS | ||||||
| 1.01 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil | 25.14 | cum | 236.63 ₹5,948.88 Lowest | 236.63 ₹5,948.88 Lowest | 236.63 ₹5,948.88 Lowest |
| 1.02 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) | 1.81 | cum | 7,286.51 ₹13,188.58 Lowest | 7,286.51 ₹13,188.58 Lowest | 7,286.51 ₹13,188.58 Lowest |
| 1.03 | Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete | 63.58 | sqm | 354.69 ₹22,551.19 Lowest | 354.69 ₹22,551.19 Lowest | 354.69 ₹22,551.19 Lowest |
| 1.04 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing
in position and binding all complete upto plinth levelThermo - Mechanically Treated
bars of grade Fe-500D or more | 543.01 | Kg | 103.26 ₹56,070.8 Lowest | 103.26 ₹56,070.8 Lowest | 103.26 ₹56,070.8 Lowest |
| 1.05 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources) nominal size derived from natural sources) | 9.58 | cum | 9,634.13 ₹92,333.5 Lowest | 9,634.13 ₹92,333.5 Lowest | 9,634.13 ₹92,333.5 Lowest |
| 1.06 | 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) | 21.6 | cum | 339.63 ₹7,336.01 Lowest | 339.63 ₹7,336.01 Lowest | 339.63 ₹7,336.01 Lowest |
| 1.07 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. | 15.39 | cum | 292.52 ₹4,501.3 Lowest | 292.52 ₹4,501.3 Lowest | 292.52 ₹4,501.3 Lowest |
| 1.08 | Supply and fixing of name board with angles, flats, square pipe, ACP sheet including nut and bolts. 2 nos per mast, 1Sqm in area. | 17 | each | 2,425.58 ₹41,234.86 Lowest | 2,425.58 ₹41,234.86 Lowest | 2,425.58 ₹41,234.86 Lowest |
| 1.09 | Fabrication supply, conveyance & installation of Granite name board indicating the cost involved, the commencement, completion and inauguration date etc | 17 | each | 3,553.59 ₹60,411.03 Lowest | 3,553.59 ₹60,411.03 Lowest | 3,553.59 ₹60,411.03 Lowest |
Tender Value
Refer Docs
EMD Value
₹47,131
Closing Date
21 Jan 2026, 4:00 pmClosed
Manager (Electrical Projects)
KEL MAMALA KOCHI
MLA ADS-TANUR LAC-SITC OF 8 METER MINIMAST WITH 150 WX4 LED FLOOD LIGHT AND 12 METER HIGHMAST WITH 200 WX6 LED FLOOD LIGHT AT VARIOUS LOCATION IN TANUR LAC
2026_KEL_827608_2
KEL/KMEP/EPROC/071/2025-26
Open Tender
Electrical Works
Item Rate
KEL MAMALA KOCHI
Please refer Tender documents.
6 documents required · 6 mandatory
₹2,500
₹47,131
Yes
28 Jan 2026
14 Jan 2026
22 Jan 2026
14 Jan 2026
21 Jan 2026
14 Jan 2026
14 Jan 2026 - 21 Jan 2026
CIVIL WORKS
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources) nominal size derived from natural sources)
12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
Supply and fixing of name board with angles, flats, square pipe, ACP sheet including nut and bolts. 2 nos per mast, 1Sqm in area.
Fabrication supply, conveyance & installation of Granite name board indicating the cost involved, the commencement, completion and inauguration date etc
ELECTRICAL WORKS
Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter. 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x16mm suitable for windspeed as per IS 875 Part III fixed head frame including round arm luminary carriage suitable to install 4/6 nos luminaries in symmetrical arrangement including connector foundation bolt 4 nos existing RCC foundation and junction box etc, complete 8 Meters
Installation, testing and commissioning of 150W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding suitable for 1.60/ 2.00 mm sheet
Supply and installation of a Digital timer, operating at 220-250 VAC, 50Hz, with a 25A/1.5HP capacity. It features 5 On/Off program settings for daily and weekly schedules, along with manual start, ON delay, and OFF delay settings. Equipped witha high-precision, industrial-grade chip and strong anti-interference capabilities, the timer can automatically turn on and off the power supply of various electrical equipment according to the time set by the user. The controlled objects can include street lights, light boxes, neon lights, and high/mini mast systems. It also includes a sufficient battery backup for time memory in case of power failure, and comes with suitable fittings for use in a distribution box or MV panel with FRLS PVC insulated 5 mm single core cable suitable for control wiring towards contactor
Supply and installation of a double pole 25A Contactor, rated for 220-250 VAC.50Hz operation. It can control street lights, light boxes, neon lights, high/mini mast systems, and induction loads
Supply and installation of an IP20 Surge Protective Device (SPD) with suitable fittings for a distribution box or MY panel. Specifications include: Voltage Protection Level (Up), Nominal Voltage: 230V. UOC, LOKV. L-N: 7kV, L-PE: 7KV, N-PE: 7KV Nominal Discharge Current (8/20&micros): 10kA. Total Discharge Current (8/20&micros): 60kA. Response Time: &lt.35 ns. Ambient Temperature (Ta): -10 to 55&deg C
Supply and fixing HRC fuse base of 32 A using suitable nut and bolt. 32 A 2-way neutral links mounted on DMC/SMC base
Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).25 x 3 mm GI strip
Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3 core 6 sq mm
Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size
Supplying and making end termination with brass compression gland and aluminium lugs forfollowing size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required. 3 X 6 sq. mm (19mm)
Supply and installation of 5A, 220V voltage protector (1100W) with auto cut-off at 280V/140V, LED indicator, fast response time (2s), and compact design (73×44×30mm). Includes testing and commissioning.
Supply and panel board wiring - 4 sq.mm ring type leg, 2.5 sq.mm wire, 0.5 sq.mm wire, 1.5 sq.mm non insulated CP-1 pin terminal with suitable size heat shrink, 2.5 sq.mm non insulated CP-1 pin terminal with suitable size heat shrink including wire cutting, leg crimping, sleeving, component fixing and wiring testing and packing
Supply installation testing and commissioning of High Mast using Octogaonal Pole made single/two sections of hot dip galvanised GI sheet 100mm top diameter, 360mm bottom diameter thickness 3mm mm suitable for wind speed as per IS 875 Part III with head frame assembly two point suspension system with steel wire rope 5mm dia double drum winching system w and including round arm galvanized luminary carriage suitable to install 6/8 nos luminaries in symmetrical arrangement control gear box and lighting spikes with single phase operation power tool installed inside the base compartment including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc, complete 12 Meters
Installation, testing and commissioning of 200W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
Supply and fixing of 25A 2 Pole AC 1 rated power contactor, 25A Connector, Digital timer, Suitable Copper socket, 2.5 sq. mm ISI marked FRLS PVC insulated single core copper conductor cable, 1.5 sq. mm ISI marked FRLS PVC insulated single core copper conductor cable
Supply Conveyance and Installation of Surge protector device of IP 20,Mounting type: Screw,Voltage protection level(UP),Nominal voltage:230V ,UOC:10KV,L-N:7 KV,L-PE:7 KV,NPE: 7 KV,Nominal discharge current (8/20):10 KA,Total discharge current (8/20):60 KA, Response time:<35 ns, Ta: -10-55
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Four pole and neutral.
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.4 core 2.50 sq mm
EXCLUSIVE OF GST
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.41 MB
BOQ_1388948.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .