ASISTANT ENGINEER, R.G.KAR ELECTRICAL SUB-DIVISION
1, Khudiram Bose Sarani, Kolkata-700 004
Replacement of non- Functional Earthing of CB Substation by New Copper earth Plate within the R.G.KAR MC and H ES-I
2026_WBPWD_5079296_1
WBPWD/AE/RGKARESD/NIQ-63/26-27
Open Tender
ELECTRICAL WORKS M/R
Item Rate
15 days
R.G.KAR MEDICAL COLLEGE AND HOSPITAL
Please refer Tender documents.
7 documents required · 7 mandatory
₹3,742
12 Oct 2026
12 Oct 2026
23 Oct 2026
13 Oct 2026
21 Oct 2026
13 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having lockingarrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. | 4 | No. | - | - |
| 2 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm
dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required | 4 | No. | - | - |
| 3 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) | 80 | No. | - | - |
| 4 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) | 80 | No. | - | - |
| 5 | Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required | 4 | Mtr. | - | - |
| 6 | Providing and fixing earth bus of 50 mm X 5 mm
copper strip on surface for connections etc. as
required. | 1 | Mtr. | - | - |
| 7 | Charges for damaging the tough thick mortar laid under the floor and disbersing the damaged mortar out of the site. | 1 | Lmp | - | - |
| 8 | SITC of fabricated MS Bars to conceal the laid Copper continuity Barsfrom the transformer to the Copper earth Plate to prevent The stealing of the coper pipe by means of MS Bars and employing skilled welder and fabricator. The rate is inclusve of the charges of welding machine aand other allied tools and tackles. | 100 | Kg | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.76 MB
2911Form.pdf
Tender Documents • 0.50 MB
BOQ_5182020.xls
BOQ • 0.23 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .