Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.7 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹41.6 L+₹2.9 L (7.54%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹41.8 L+₹3.1 L (7.94%)Admitted-Finance 50 1 56 13 SURYA TOWERS ASR NAGAR SEETHAMMADHARA VISAKHAPATNAM 530 013 | VISAKHAPATANAM | ANDHRA PRADESH | 530013 | L3 | Admitted-Finance | |
| 4 | L4₹42.3 L+₹3.6 L (9.19%)Admitted-Finance | L4 | Admitted-Finance | |
| 5 | L5₹42.6 L+₹3.9 L (10.1%)Admitted-Finance | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | SRIVALLI ENGINEERS L6 | HARSHITHA INFRA L1 | SWATHI CONSTRUCTIONS L5 | sri sai ram constructions L2 | SAI KRISHNA ASSOCIATES L3 | M/S CHANDRA ENGINEERS AND CONTRACTORS L7 | LAKSHMI SAI CONSTRUCTIONS L4 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down the defective spare parts screw type compressor/ panel from the central type AC plant. M&L for carrying out complete rectification, servicing, testing and commissioning of compressors, condensors and chiller system of capacity 3x120 TR AC plant and panels, model 30XA, make Carrier in P-168 including panel recommissioning, Re-assembling the compressor in all respect, refixing the same in its original position and re-connecting all disconnected lines including Leak test, pressure, nitrogen test, Vacuuming etc, in serviceable and operational condition complete all as manufacturers instruction and as directed by Engr-in-charge.
Location: Bhramos | 1 | Each Job | 33,900 ₹33,900 | 32,000 ₹32,000 Lowest | 34,500 ₹34,500 | 39,500 ₹39,500 | 33,800 ₹33,800 | 34,200 ₹34,200 | 33,500 ₹33,500 |
| 1.01Note: Note: (i) Necessary T&P, MS Nuts, MS Bolts, MS washers, gaskets, ladders, lubricants, waste cotton, filter drier core, transportaion, etc shall be arranged by the tenderer and the cost deemed to be included the unit rate quoted. (ii) Labour charges for removing unserviceable parts / accessories and replacement with new one shall be deemed to be included in the unit rate. (iii) Any minor spares/parts/accessories not covered in the Schedule "A" Part but required for completion of job shall be provided by the contractor and the rate quoted shall be deemed to have been inclusive of such items. | ||||||||||
| 1.02(iv) Renewal of control wiring in the system/ panel is deemed to be included in the rate. (v) Servicing shall be carried out through OEM or his authorised agency only and test report shall be submitted in duplicate. (vi) The below item should be compatible with Model 30XA at Site existing is given above. | ||||||||||
| 1.03 | Supply only Control panel door hinges (XA left and right), | 2 | Each | 2,700 ₹5,400 | 2,500 ₹5,000 Lowest | 2,560 ₹5,120 | 2,650 ₹5,300 | 2,740 ₹5,480 | 2,750 ₹5,500 | 2,800 ₹5,600 |
| 1.04 | Supply only External oil filter, Carrier part No.2015970 | 1 | Each | 52,100 ₹52,100 | 48,100 ₹48,100 Lowest | 51,200 ₹51,200 | 50,250 ₹50,250 | 50,000 ₹50,000 | 52,450 ₹52,450 | 54,000 ₹54,000 |
| 1.05 | Supply only Temp. Sensor, Carrier part No.2008536 | 2 | Each | 6,850 ₹13,700 | 6,750 ₹13,500 Lowest | 7,000 ₹14,000 | 6,925 ₹13,850 | 7,000 ₹14,000 | 7,050 ₹14,100 | 7,420 ₹14,840 |
| 1.06 | Supply only Flow Switch, Carrier part No.2015971 | 1 | Each | 50,000 ₹50,000 | 48,210 ₹48,210 Lowest | 50,550 ₹50,550 | 49,980 ₹49,980 | 50,500 ₹50,500 | 51,250 ₹51,250 | 54,280 ₹54,280 |
| 1.07 | Supply only Flow Switch cable (30XW), Carrier part No.2025823 | 1 | Each | 31,840 ₹31,840 | 29,480 ₹29,480 Lowest | 30,000 ₹30,000 | 31,250 ₹31,250 | 31,000 ₹31,000 | 32,660 ₹32,660 | 30,800 ₹30,800 |
| 1.08 | supply only electrical card/EXV Board carrier part no 2008539N. | 1 | Each | 1,79,600 ₹1,79,600 | 1,56,400 ₹1,56,400 Lowest | 1,81,000 ₹1,81,000 | 1,74,250 ₹1,74,250 | 1,69,500 ₹1,69,500 | 1,82,420 ₹1,82,420 | 1,79,580 ₹1,79,580 |
| 1.09 | Supply only card display and TCPM Board Carrier part No.2010892 and 2025687 | 1 | Each | 3,11,250 ₹3,11,250 | 2,72,000 ₹2,72,000 Lowest | 3,05,000 ₹3,05,000 | 2,98,610 ₹2,98,610 | 3,00,000 ₹3,00,000 | 3,00,000 ₹3,00,000 | 3,02,580 ₹3,02,580 |
Tender Value
₹39.1 L
EMD Value
₹78,200
Closing Date
14 Nov 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE NO 2 VISAKHAPATNAM
CWE NO 2 VISAKHAPATNAM, HQ CE N COMPLEX, RAILWAY STATION ROAD, VISAKHAPATNAM - 530004
REPAIRS / MAINTENANCE OF VARIOUS CAPACITY OF CHILLER UNITS OF CENTRALISED AC PLANTS OF CARRIER MAKE AT NAVAL STATION, BHEEMUNIPATNAM UNDER CWE NO 2 VISAKHAPATNAM
2025_MES_736732_1
82745
Open Tender
Machineries/ Mechanical Engg Items
Item Rate
180 days
GE P NAVY KALINGA
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE (P) (N) KALINGA
₹78,200
Yes
23 Jun 2026
24 Oct 2025
21 Nov 2025
24 Oct 2025
14 Nov 2025
7 Nov 2025
24 Oct 2025 - 7 Nov 2025
Amount
Taking down the defective spare parts screw type compressor/ panel from the central type AC plant. M&L for carrying out complete rectification, servicing, testing and commissioning of compressors, condensors and chiller system of capacity 3x120 TR AC plant and panels, model 30XA, make Carrier in P-168 including panel recommissioning, Re-assembling the compressor in all respect, refixing the same in its original position and re-connecting all disconnected lines including Leak test, pressure, nitrogen test, Vacuuming etc, in serviceable and operational condition complete all as manufacturers instruction and as directed by Engr-in-charge. Location: Bhramos
Note: Note: (i) Necessary T&P, MS Nuts, MS Bolts, MS washers, gaskets, ladders, lubricants, waste cotton, filter drier core, transportaion, etc shall be arranged by the tenderer and the cost deemed to be included the unit rate quoted. (ii) Labour charges for removing unserviceable parts / accessories and replacement with new one shall be deemed to be included in the unit rate. (iii) Any minor spares/parts/accessories not covered in the Schedule "A" Part but required for completion of job shall be provided by the contractor and the rate quoted shall be deemed to have been inclusive of such items.
(iv) Renewal of control wiring in the system/ panel is deemed to be included in the rate. (v) Servicing shall be carried out through OEM or his authorised agency only and test report shall be submitted in duplicate. (vi) The below item should be compatible with Model 30XA at Site existing is given above.
Supply only Control panel door hinges (XA left and right),
Supply only External oil filter, Carrier part No.2015970
Supply only Temp. Sensor, Carrier part No.2008536
Supply only Flow Switch, Carrier part No.2015971
Supply only Flow Switch cable (30XW), Carrier part No.2025823
supply only electrical card/EXV Board carrier part no 2008539N.
Supply only card display and TCPM Board Carrier part No.2010892 and 2025687
Supply only Pressure Sensor, Carrier part No.2010882
Supply only contactor 25 amps from the existing panel.
Supply only Refrigerants gas R-134a
Supply only Contactor 3TF51,Carrier part No.2018571
Supply loading and unloading solenoid valve (1+1)
Supply only unloader solenoid coil
Supply only SFU 400 Amps
Supply only synthetic oil (5 Gal)
Taking down the defective spare parts screw type compressor/pannel from the central type AC plant M&L for carrying out complete rectification, servicing, testing and commissioning of compressors, condensors and chiller system of capacity 3x180 TR AC plant and panels, model 30XW0652 Make Carrier in Hanger (1 to 6) including panel recommissioning, Re-assembling the compressor in all respect, refixing the same in its original position and re-connecting all disconnected lines including Leak test, pressure, nitrogen test, Vacuuming etc, in serviceable and operational condition complete all as manufactureres instruction and as directed by Engr-in- charge.
Note: (i) Necessary T&P, MS Nuts, MS Bolts, MS washers, gaskets, ladders, lubricants, waste cotton, drier core filter, transportaion, etc shall be arranged by the tenderer and the cost deemed to be included the unit rate quoted. (ii) Labour charges for removing unserviceable parts/ accessories and replacement with new one shall be deemed to be included in the unit rate. (iii) Any minor spares/parts/accessories not covered in the Schedule "A" Part but required for completion of job shall be provided by the contractor and the rate quoted shall be deemed to have been inclusive of such items.
(iv) Renewal of control wiring in the system/panel is deemed to be included in the rate. (v) Servicing shall be carried out through OEM or his authorised agency only and test report shall be submitted in duplicate. (vi) The below item should be compatible with Model 30XW0652 at Site existing is given above.
Supply only MCCB 3 pole 63 amps as per exising pannel.
Supply only Contactor Set for 3 pole TC contactor AC3 ,25 Amps as existing pannel.
Supply of flow switch
Supply only temp sensor as existing .
Mother Board & Display Board 12V SMPS any type including Cable any type make
Taking down the defective spare screw type compressor/ panel from the central type AC plant. M&L for carrying out complete rectification, servicing, testing and commissioning of compressors, condensors and chiller system of capacity 3x60 TR AC plant and panels, model 30XW0262, make Carrier in Hanger 7&8 including panel recommissioning, Re-assembling the compressor in all respect, refixing the same in its original position and re-connecting all disconnected lines including Leak test, pressure, nitrogen test, Vacuuming etc, in serviceable and operational condition complete all as manufacturers instruction and as directed by Engr-in-charge.
Note: (i) Necessary T&P, MS Nuts, MS Bolts, MS washers, gaskets, ladders, lubricants, waste cotton, drier core filter, transportaion, etc shall be arranged by the tenderer and the cost deemed to be included the unit rate quoted. (ii) Labour charges for removing unserviceable parts / accessories and replacement with new one shall be deemed to be included in the unit rate. (iii) Any minor spares / parts /accessories not covered in the Schedule "A" Part but required for completion of job shall be provided by the contractor and the rate quoted shall be deemed to have been inclusive of such items.
(iv) Renewal of control wiring in the system/ panel is deemed to be included in the rate. (v) Servicing shall be carried out through OEM or his authorised agency only and test report shall be submitted in duplicate. (vi) The below item should be compatible with Model 30XW0262 at site existing is given above.
Supply only system manager (4.3" pic 6 control) carrier part no- 2041965
Supply only Refrigerants gas R-134a
Supply only temp sensor as existing .
Taking down the defective spare parts screw type compressor/panel from the central type AC plant. M&L for carrying out complete rectification, servicing, testing and commissioning of compressors, condensors and chiller system of capacity 3x80 TR AC plant and panels, model 30XW0312, make Carrier in hanger 19&20 including pannel recommissioning, Re-assembling the compressor in all respect, refixing the same in its original position and re-connecting all disconnected lines including leak test, pressure, nitrogen test, Vacuuming etc, in serviceable and operational condition all as per manufacturers instruction complete all as specified and directed.
Note: (i) Necessary T&P, MS Nuts, MS Bolts, MS washers, gaskets, ladders, lubricants, waste cotton, transportaion, etc shall be arranged by the tenderer and the cost deemed to be included the unit rate quoted. (ii) Labour charges for removing unserviceable parts / accessories and replacement with new one shall be deemed to be included in the unit rate.
(iii) Any minor spares / parts /accessories not covered in the Schedule "A" Part but required for completion of job shall be provided by the contractor and the rate quoted shall be deemed to have been inclusive of such items. (iv) Renewal of control wiring in the system/ panel is deemed to be included in the rate. (v) Servicing shall be carried out through OEM or his authorised agency only and test report shall be submitted in duplicate. (vi) The below item should be compitable with Model 30XW0312 at Site existing is given above.
Supply contactor 3 pole 3RT5044 as existing panel.
Supply only temp sensor as existing
Supply only flow switch
Supply only flow switch cable
Mother Board & Display Board 12V SMPS any type including Cable any type make
Taking down the defective spare parts screw type compressor/panel from the central type AC plant. M&L for carrying out complete rectification, servicing, testing and commissioning of compressors, condensors and chiller system of capacity 3x65 TR AC plant and panels, model 30XW0312, make Carrier in Magazine P-243 at NAD including panel recommissioning, Re-assembling the compressor in all respect, refixing the same in its original position and re-connecting all disconnected lines including Leak test, pressure, nitrogen test, Vacuuming etc, in serviceable and operational condition all as per manufacturers instruction complete all as specified and directed.
Note: (i) Necessary T&P, MS Nuts, MS Bolts, MS washers, gaskets, ladders, lubricants, waste cotton, transportation, etc shall be arranged by the tenderer and the cost deemed to be included the unit rate quoted. (ii) Labour charges for removing unserviceable parts/ accessories and replacement with new one shall be deemed to be included in the unit rate.
(iii) Any minor spares / parts /accessories not covered in the Schedule "A" Part but required for completion of job shall be provided by the contractor and the rate quoted shall be deemed to have been inclusive of such items. (iv) Renewal of control wiring in the system/ panel is deemed to be included in the rate. (v) Servicing shall be carried out through OEM or his authorised agency only and test report shall be submitted in duplicate. (vi) The below item should be compitable with Model 30XW0312 at Site existing is given above.
Supply only flow switch.
Supply only flow switch cable
Supply of contactor 3 pole 3RT5044 as existing panel
Supply only loading and unloading solenoid valve (1+1)
Supply only unloader solenoid coil
Mother Board & Display Board 12V SMPS any type including Cable any type make
Taking down the defective spare parts screw type compressor/panel from the central type AC plant. M&L for carrying out complete rectification, servicing, testing and commissioning of compressors, condensors and chiller system of capacity 3x65 TR AC plant and panels, model 30XW0312, make Carrier in Magazine P-245 at NAD including panel recommissioning, Re-assembling the compressor in all respect, refixing the same in its original position and re-connecting all disconnected lines including Leak test, pressure, nitrogen test, Vacuuming etc, in serviceable and operational condition complete all as manufacturers instruction and as directed by Engr-in- charge.
Note: (i) Necessary T&P, MS Nuts, MS Bolts, MS washers, gaskets, ladders, lubricants, waste cotton, transportaion,etc shall be arranged by the tenderer and the cost deemed to be included the unit rate quoted. (ii) Labour charges for removing unserviceable parts / accessories and replacement with new one shall be deemed to be included in the unit rate.
(iii) Any minor spares / parts /accessories not covered in the Schedule "A" Part but required for completion of job shall be provided by the contractor and the rate quoted shall be deemed to have been inclusive of such items. (iv) Renewal of control wiring in the system/ panel is deemed to be included in the rate. (v) Servicing shall be carried out through OEM or his authorised agency only and test report shall be submitted in duplicate. (vi) The below item should be compatible with Model 30XW0312 at Site existing is given above.
Supply only Flow switch .
Supply only pressure sensor .
Supply only temp sensor
Mother Board & Display Board 12V SMPS any type including Cable any type make
Taking down the defective spare screw type compressor /panel from the central type AC plant. M&L for carrying out complete rectification, servicing, testing and commissioning of compressors, condensors and chiller system of capacity 3x90 TR AC plant and panels, model 30XW0312, make Carrier in Magazine 244 at NAD including pannel recommissioning, Re-assembling the compressor in all respect, refixing the same in its original position and reconnecting all disconnected lines including Leak test, pressure, nitrogen test, Vacuuming etc, in serviceable and operational condition complete all as manufacturers instruction and as directed by Engr-in- charge.
Note: (i) Necessary T&P, MS Nuts, MS Bolts, MS washers, gaskets, ladders, lubricants, waste cotton, transportation,etc shall be arranged by the tenderer and the cost deemed to be included the unit rate quoted. (ii) Labour charges for removing unserviceable parts/ accessories and replacement with new one shall be deemed to be included in the unit rate. (iii) Any minor spares / parts /accessories not covered in the Schedule "A" Part but required for completion of job shall be provided by the contractor and the rate quoted shall be deemed to have been inclusive of such items.
(iv) Renewal of control wiring in the system/ panel is deemed to be included in the rate. (v) Servicing shall be carried out through OEM or his authorised agency only and test report shall be submitted in duplicate. (vi) The below item should be compitable with Model 30XW0312 at Site existing is given above.
Supply only flow switch cable
Supply only temp sensor
Supply only pressure Sensor
Supply only flow switch
M&L for carrying out the descaling of the shell & tube condensers by isolation of each condenser by providing of dummy plate for inlet & outlet connection and separation of condenser from water circulation without disturbing the operation of the AC plant, carrying out the descaling by circulation of the diluted scale removing agent organic compound type chemical of RA III / chemtex Brand at the appropriate ratio depend upon as recommended by manufacturer and the scale deposit inside copper tube by forced circulation and opening the end covers, mechanical brushing the copper tubes with nylon brushes of various size to remove complete scale, de-greasing with caustic soda solution and flushing out with fresh water, refixing all disconnected pipes lines, end covers with new rubber gasket and opening water line valves and checking of water leakages, apply grease to all M.S. Bolts & Nuts and put the condensers of the following capacities in operational complete all as directed.
65TR Capacity
70 TR Capacity
80 TR Capacity
90 TR Capacity
180 TR Capacity
sri sai ram constructions (BID ID -3474421)
SAI KRISHNA ASSOCIATES (BID ID -3474461)
LAKSHMI SAI CONSTRUCTIONS (BID ID -3474558)
SWATHI CONSTRUCTIONS (BID ID -3474413)
SRIVALLI ENGINEERS (BID ID -3474122)
M/S CHANDRA ENGINEERS AND CONTRACTORS (BID ID -3474497)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
cancelled_1.pdf
pdf • 0.22 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.48 MB
TENDER.pdf
Tender Documents • 0.77 MB
BOQ_824909.xls
BOQ • 0.81 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .