Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance SANAT NAGAR SRINAGAR PIN 190005 J K | SRINAGAR | JAMMU AND KASHMIR | 190005 | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
Tender Value
₹88 L
EMD Value
₹1.8 L
Closing Date
28 Oct 2022, 12:00 pmClosed
Executive Engineer MHCHD, Srinagar
Office of the Executive Engineer, MHCHD, Srinagar
Supply, Installation, Testing and Commissioning of Central Heating System to Sub District Hospital, Kangan.
2022_PWDJK_193468_1
MHCHD/TS /2022-23/130/e-tendering Dt22-10-2022
Open Tender
Machineries/ Mechanical Engg Items
Item Wise
90 days
SubDistrict Hospital, Kangan
As Detailed in NIT
6 documents required · 6 mandatory
₹2,000
Executive Engineer MHCHD, Srinagar
₹1.8 L
28 Oct 2022
22 Oct 2022
28 Oct 2022
22 Oct 2022
28 Oct 2022
22 Oct 2022
Amount
Supply Installation Testing and commissioning of Horizontal, HSD fired, coil type Hot Water Generator of capacity 4 lac kcal/hr each complete with , combustion equipments, control panel, control valves & other accessories including the flue gasses duct (chimney) with allied civil works and as per techinical specifications
Supply Installation Testing and commissioning of 7.5 hp, 3 Phase hot water circulation pump with Mechanical Seal coupled with electric motor fitted on a base frame including the civil foundation and as per techinical specifications
Supply Installation Testing and commissioning of 1 hp, 3Phase Soft water Pump complete with electric motor and as per techinical specifications
Supply Installation Testing and commissioning of 1 hp, 3Phase Raw water Pump complete with electric motor and as per techinical specifications
Supply Installation Testing and commissioning of 3 hp Gear type Oil transfer Pump (2" x 2") complete with electric motor and as per techinical specifications
Supply Installation Testing and commissioning of MS Mixing Tank of capacity 3000 lts duly insulated /cladded along with allied items and as per techinical specifications
Supply Installation Testing and commissioning of 20 kl (underground) MS Bulk Oil Storage Tank complete with manhole cover, calibrated dip stick, civil work as per IOC norms and keeping in view water table of area along with necessary connections including vent pipes, decanting pipe etc and as per techinical specifications
Supply Installation Testing and commissioning of 990 lts MS Day Oil Tank complete with man hole cover, gauge glass, necessary connections & structural supports for mounting oil tank as per techinical specifications
Supply Installation Testing and commissioning of 1000 lts HDPE tripple layer soft water Storage tanks complete with piping, fittings, valves, mountings , pedestal and other mountings as per techinical specifications
Supply Installation Testing and commissioning of 500 lts MS Expansion tank complete with piping, fittings, valves, mountings, insulation & cladding as per techinical specifications
Supply Installation Testing and commissioning of Water Softener (FRP body)1500 lts/hr. , with accessories as per techinical specifications
Supply Installation Testing and commissioning of radiators of following capacities as per techinical specifications
4000 kcal/hr - Triple panel
3500 kcal/hr - Triple panel
3000 kcal/hr - Double panel
2500 kcal/hr - Double panel
2000 kcal/hr - Double panel
1500 kcal/hr - Double panel
1000 kcal/hr - Double panel
500 kcal/hr - Double panel
Supply Installation Testing and commissioning of Hydronic Hi wall units Compleye with inlet/outlet valves, Y-strainer and copper piping and fittings etc. Inlet Water Temp. 75˚C Outlet Water Temp. 65˚C Room Temp. 22˚C.
M S C CLASS Hot water Piping (Above ground)
Supply Installation Testing and commissioning of Mild Steel class ‘C’ ERW pipes of following diameters with fittings like tees, elbows, bends, junctions, unions, flanges etc. clamps structural supports, wooden pedestals as per site requirements including application of two coats of red oxide primer followed by two or more coats of butiminous paint and as per techinical specifications
M S C CLASS Hot water Piping (Under ground)
Supply Installation Testing and commissioning of Mild Steel class ‘C’ ERW pipes of following diameters with fittings like tees, elbows, bends, junctions, unions, flanges etc. to be laid underground in trench at a depth upto 3 feet below ground level on cement concrete blocks at a distance of 3 m as per techinical specifications.
M.S Piping (Galvanised)
Supply Installation Testing and commissioning of Mild Steel ERW (Galvanised) water piping of class 'B' complete with fittings as per specifications and drawings.
Support for Hot water piping at variouys locations to be fabricated out of 40x40x5 mm, 50x50x5 mm, 65x65x5mm as per site requirements.
Pipe Insulation
Hot Water Pipe Insulation (Above ground)
Supply Installation Testing and commissioning of Glass wool insulation of following diameters as per Specifications
150mm dia (50mm thick)
125mm dia (50mm thick)
100mm dia (50mm thick)
80mm dia (50mm thick)
65mm dia (50mm thick)
50mm dia (50mm thick)
40mm dia (25mm thick)
32mm dia (25mm thick)
25mm dia (25mm thick)
20mm dia (25mm thick)
Supply Installation Testing and commissioning of aluminum cladding of 24 Gauge over insulation of pipes of following dias as per Specifications
150mm dia
125mm dia
100mm dia
80mm dia
65mm dia
50mm dia
40mm dia
32mm dia
25mm dia
20mm dia
Supply Installation Testing and commissioning of Glass wool insulation of following diameters along with chicken mesh and hysen cloth wrap as per Specifications
50mm dia (50mm thick)
40mm dia (25mm thick)
32mm dia (25mm thick)
25mm dia (25mm thick)
20mm dia (25mm thick)
Supply Installation Testing and commissioning of aluminum cladding of 24 Gauge over insulation of pipes of following dias as per Specifications
50mm dia
40mm dia
32mm dia
25mm dia
20mm dia
Underground Pipe Insulation
Supply Installation Testing and commissioning of puff Insulation/Glass wool/Rock wool insulation of following diameters along with chicken mesh and tar felt as per Specifications
125mm dia (50mm thick)
100mm dia (50mm thick)
50mm dia (50mm thick)
40mm dia (25mm thick)
25mm dia (25mm thick)
20mm dia (25mm thick)
Underground/Above
4mm thick pypekote insulation as per specifications for
50mm dia
40mm dia
25mm dia
20mm dia
Supply Installation Testing and commissioning of valves along with allied items of below mentioned diameters as per techinical specifications
Butterfly Valves
Ball Valves
Y STRAINERS as per techinical specifications
80 mm dia ( CI Flanged)
50 mm dia ( GM Threaded)
Non Return Valves as per techinical specifications
65 mm dia ( CI Flanged)
50 mm dia ( GM Threaded)
Air Release Valves with isolation ball valves (25 mm) as per techinical specifications
Pressure gauge glycerine filled with isolation cock as per techinical specifications (100mm dial)
Thermometer (100mm dial) as per techinical specifications
Electrical Works
Main Panel
Main Control Panel fabricated out of 16 SWG powdered coated having separate cubicals for each equipment viz. Hot Water Generator (3 No's), Hot Water Circulation Pumps (2 No's), Soft Water Pumps (2 No's), Softener pump (1 No), HSD Transfer Pump(2 No's), and three empty with main and individual switch gears for Hot Water Generator / Pumps and starters for pumps On-Load Change Over Switch (200A), MCCB (160A) The control panel shall be provided with the Aluminium bus bars dully insulated of required ratings.
Servo stabilizer panel
Sub Panel for Servo stabilizer with 160 A main MCCB, Outgoing 160 A FP Bye-pass switch (for AVR Bye Pass) etc
Cable Tray
Perforated cable tray of 2 mm thickness and supported from ceiling the wall duly painted as per site condition
300 mm wide
150 mm wide
Conduits
MS Conduit Pipes
Electrical Cable
Providing and fixing PVC insulated unarmoured copper conductor cables from main panel board to various equipments through walls/ceiling with appropriate clamps and fixing arrangements, cable tray etc. as per specifications
4 Core- 4 Sqmm
3 Core- 2.5 Sqmm
3 Core- 4 Sqmm
2 core- 1.5 Sqmm
3.5 core- 150 Sqmm
Supply Installation Testing and commissioning of 100 KVA 3 phase, oil cooled servo stabilizer micro processor controlled with high and low voltage cut off, single phase preventer, short circuit and over load protection having digital display with input of 150-460 volt phase to phase and output of 415 volts±1% phase to phase.
Earthing Pit
Earthing for various equipments inside boiler house using copper electrode of size of 40 mm dia placed in a pit filled earthing chemical by copper strip of size 20x3 mm alongwith perforated G.I pipe
Earthing Strip
Copper strip of size 20x3 mm from earthing electrode to the Panel, Stabilizer, boiler and pumps using proper fastners conceeled under floor.
Testing and commissioning of the already executed work
Hydraulic testing of the pipeline network installed by J&K housing board including the testing and commissioning of the radaitorsalready installed
Supply Installation Testing and commissioning of Carbon dioxide fire extinguishers of capacity 4.5 Kg as per Technical Specifications of Annexure 'B'
Supply Installation Testing and commissioning of ABC type fire extinguishers of capacity 6 Kg as per Technical Specifications of Annexure 'B'
Supply Installation Testing and commissioning of Foam type fire extinguishers of capacity 9 Kg as per Technical Specifications of Annexure 'B'
M/s Bhat Engineering Works
GOOD LUCK TRADERS
FAVOURITE ELECTRICALS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .