Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.6 LAccepted-AOC FLAT NO A 402 SHANKAR HEIGHTS NEAR CHETANA SCHOOL HAJI MALANG ROAD KALYAN EAST THANE MUMBAI 421 306 | THANE | MAHARASHTRA | 421306 | L1 | Accepted-AOC ACCEPTED L1 | |
| 2 | L2₹22.9 L+₹1.3 L (5.88%)Rejected-Finance SHOP NO 5 OPP SHANI MANDIR PROFESSOR COLONY DISTT YAMUNA NAGAR HARYANA 135001 | YAMUNANAGAR | HARYANA | 135001 | L2 | Rejected-Finance Being rejected L2 | |
| 3 | L3₹28.0 L+₹6.5 L (29.9%)Rejected-Finance | L3 | Rejected-Finance Being rejected L3 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
13 Aug 2022, 6:00 pmClosed
SHRI N N LANGHE EE
GE SOUTH AMBALA CANTT
REPAIR MAINT OF INTERNAL ELECTRIFICATION SYSTEM AND ALLIED ESSENTIAL SERVICES INCLUDING CEILING FANS EXHAUST FANS AND GEYSERS MD ACCN OF OFFICERS JCOs ORs IN THE AREA OF ICC LINES ROAD AND CERTAIN MISC UNITS QTRS OF SECTOR C UNDER GE SOUTH AMBALA
2022_MES_528205_2
GE(SOUTH)/AMB-25/2022-2023
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE SOUTH AMBALA CANTT
AS PER NIT
9 documents required · 9 mandatory
₹500
GE SOUTH AMBALA CANTT
₹60,000
Yes
13 Sept 2022
23 Jul 2022
20 Aug 2022
23 Jul 2022
13 Aug 2022
30 Jul 2022
23 Jul 2022 - 29 Jul 2022
Amount
Dismantling/taking down carefully aluminium/ copper point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators , sockets, light fittings etc., removing materials to stores for keeping in safe custody for taking credit and making good the disturbed surfaces of wall, floors, ceiling etc to match with the existing surfaces with matching OBD/White wash/Distemper complete all as specified and as directed.
Material and labour for point wiring in existing conduit using approved colour coding as per IS, with multi stranded copper conductor 1.5 sqmm (Nominal area), single core, FRLSH PVC insulated and unsheathed stranded cable drawn through and including existing non metallic/mettalic heavy duty concealed/Surface conduit and including replacement of its fittings including all tees, bell mouth pieces and fixing accessories such as couplers, saddlers, pipe hooks etc, PVC junction boxes ISI marked with GI flush boxes / sunken boxes made out of 1.2mm thick of any module from 2 to 18 module confirming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly including modular cover plates with frame i.e. inner and outer plate extended upto 25 mm over flush boxes /sunken boxes for housing the modular switches, socket outlets, fan regulators etc with brass screws and washers and making good the disturbed surfaces as per existing for one light / fan / Bell point contorlled by one switch including 1.5 sqmm single core PVC insulated and unsheathed FRLSH copper cable, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor upto common earth and connecting to common earth dolly with suitable size of lugs for one light point/ fan point/Bell Point controlled by one switch complete all as specified and as directed. NOTES : - (i) Point wiring & earth wire shall be connected to each & every flush/sunken box. (ii) All screws, fasteners, bolts, nuts & washer shall be cadmium plated & the cost of which is deemed to be included in the quoted unit rates.
Description all as per item No 2.00 above but for socket out let point 5 Amps on same board complete all as specified and directed.
Description all as per item No 2.00 above but for socket out let point 5 Amps on independent board complete all as specified and directed.
Description all as per srl item No 2.00 above but point wiring for onesocket out let 15 & 5 Amps (independent) controlled by one switch with using 2.5 Sq mm (nominal area) stranded copper conductor complete all as specified and directed.
Material and labour for concealed point wiring using approved colour coding as per IS, with multi stranded copper conductor 1.5 sqmm (Nominal area), single core, FRLSH (FIRE Retardant Low Smoke and low Halogen), PVC insulated and unsheathed stranded cable drawn through and including non metallic, heavy duty PVC concealed conduit not less than 20mm dia and its fittings including all tees, bell mouth pieces and fixing accessories such as couplers, saddlers, pipe hooks etc, PVC junction boxes ISI marked with GI flush boxes / sunken boxes made out of 1.2mm thick of any module from 2 to 18 module confirming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly including modular cover plates with frame i.e. inner and outer plate extended upto 25 mm over sunken box for housing the modular switches, socket outlets, fan regulators etc with brass screws and brass washers and making good the disturbed surfaces as per existing for one light / fan / bell point contorlled by one switch including 1.5 sqmm single core PVC insulated and unsheathed FRLSH (FIRE Retardant Low Smoke and low Halogen) copper cable, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor upto common earth and connecting to common earth dolly with suitable size of lugs for one light point/ fan point/bell point controlled by one switch complete all as specified and as directed. NOTES : - (i) The quoted rates shall be deemed to be inclusive for cutting chases by chase cutter in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of point wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using necessary accessories/fittings. (ii) Point wiring & earth wire shall be connected to each & every flush/sunken box. (iii) All screws, fasteners, bolts, nuts & washer shall be cadmium plated & the cost of which is deemed to be included in the quoted unit rates.
Description all as per item No 6.00 above but for socket out let point 5 Amps on same board complete all as specified and directed.
Description all as per item No 6.00 above but for socket out let point 5 Amps on independent board complete all as specified and directed.
Description all as per srl item No 6.00 above but point wiring for one socket out let 15 & 5 Amps (independent) controlled by one switch with using 2.5 Sq mm (nominal area) stranded copper conductor complete all as specified and directed.
Supply and fixing of modular switches, bell push, 6 amps one module, 230V, 50 Hz supply, complete all as specified and directed.
Supply and fixing of modular switches, one way, 6 amps one module, 230V, 50 Hz supply, complete all as specified and directed.
Supply and fixing of modular switches, one way, 16 Amps, one module, 230 volt, AC supply, complete all as specified and directed.
Supply and fixing of modular socket outlet 6 amps 5 pin combined 2 module, 230 volt, complete all as specified and directed.
Supply and fixing of modular socket outlet 2 in 1, 6/16 amps, combined 2 module, complete all as specified and directed.
Supply and fixing of fan regulator step type one module / 2 module, 120w 230 Volts, 50 Hz, AC complete all as specified and directed.
Supply and fixing of modular blanking plate 1 module complete all as specified and directed.
Material and labour for concealed point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductor drawn through and including medium grade, ISI marked, PVC conduit not less than 25 mm dia with FRLSH accessories, concealed and including provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLSH 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including provision of new 3 mm thick plastic laminated sheet top cover extended up to 25 mm over sunken box for housing the switches , socket outlets, fan regulators etc. with brass screws and washers and making good the disturbed surfaces as per existing for one light/fan point/bell point controlled by one switch. NOTES : - (i) The quoted rates shall be deemed to be inclusive for cutting chases by chase cutter in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of point wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using necessary accessories/fittings. (ii) Point wiring & earth wire shall be connected to each & every flush/sunken box. (iii) All screws, fasteners, bolts, nuts & washer shall be cadmium plated & the cost of which is deemed to be included in the quoted unit rates.
Description all as per item No 17.00 above but for socket out let point 5 Amps on same board,complete all as specified and directed.
Description all as per item No 17.00 above but for socket out let point 5 Amps on independent board,complete all as specified and directed.
Description all as per item No 17.00 above but with 2.5 Sqmm cable for 3pin 15 Amps switch socket outlet (Power Point),complete all as specified and directed.
Supply and fixing of bell push 5 Amps, flush type, single pole, one way, 230 volt, AC supply, ISI Marked, complete all as specified and directed.
Supply and fixing of switch piano 5/6 Amps, flush type, single pole, one way, 230 volt , AC supply, ISI Marked, complete all as specified and directed.
Supply and fixing of switch piano 15 Amps flush type one way 230 Volts, 50 Hz , AC supply, ISI Marked, complete all as specified and directed.
Supply and fixing of socket outlet 5 pin 6 amps, 230 volt. flush type, ISI Marked, complete all as speciied and directed.
Supply and fixing of socket outlet 2 in 1, 5 /15 amps and multi pin flush type, complete all as specified.
Supply and fixing of ceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified.
Supply and fixing of fan regulator electronic step type ,230 Volts, AC supply, suitable for ceiling fan any type/make/sweep, complete all as specified and directed.
Supply and fixing of door bell electric ,ding dong /musical type, single phase 230 volts, ISI marked complete all as specified.
Supply and fixing of lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings,complete all as specified.
Material and labour for taking down existing light fitting any type / size/make / capacity and refix the same after minor repair/ cleaning including replacement of connection wire with suitable size copper wire twin core flexible wire for connection from ceiling rose to light fitting all as specified and directed.
Supply and fixing of channel for fixing of LED tube rod, in CRCA body suitable for 18/20 watt LED tube, high efficient, AC 220-240 volts, 50 Hz and connecting with copper conductor flexible cable of size 0.50 Sqmm from ceiling rose to connector of the light including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed. Note : - (i) Tube rod shall be measured and paid for separately. (ii) Fittings must be get approved from Engr in charge to check fesibilty i.e. one end contact or two end contact for fixing in existing LED fittings.
Supply and fixing of 18 W/ 20W LED tube light two end contact, environment friendly, high efficient, T8 with aluminium extrusion heat sink for optimum performance with high luminous efficiency and easy and taking down existing tube light and removal complete all as specified and directed. Note: - Tube rod must be get approved from Engr in charge to check fesibilty i.e. one end contact or two end contact for fixing in existing LED fittings.
Supply and fixing of Inverter LED tube light 20 watt with minimum four hours battery backup fitting integrated aluminium batten with diffuser and including 20 watt LED tube high efficient, AC 220-240 volts, 50 Hz and connecting with copper conductor flexible cable of size 0.50 Sqmm from ceiling rose to connector of the light including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and as directed.
Supply and fixing of decorative surface mounted LED mirror light fitting, aluminium housing with including 10 watt LED tube, AC 220-240 volts, 50 Hz and connecting with copper conductor flexible cable of size 0.50 Sqmm from ceiling rose to connector of the light including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed.
Supply and fixing of bulk head light fitting, 10 watt, energy efficient with lamp 10 watt with provision of 2/3 core PVC copper conductor cable 0.5 Sqmm size from ceiling rose to light fitting complete including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed.
Supply and fixing in repair bracket for security light made up of 25mm dia, 0.9 metre long GI pipe, light grade, bent to required length, fixed to wall with two clamps made of 20 x 3 mm mild steel flat minimum 15cm long, 4 nos 8mm dia bolts with nuts complete all as specified and directed.
Supply and fixing in repair bracket for security light made up of 32/40mm dia, 0.9 metre long GI pipe, light grade, bent to required length, fixed to wall with two clamps made of 20 x 3 mm mild steel flat minimum 15cm long, 4 nos 8mm dia bolts with nuts complete all as specified and directed.
Supply and fixing of post top lantern LED 30W , cast aluminium spigot, with high effieient LED light, with poly carbonate diffuser, complete with high efficient LED lamp 30 W and accessories internally pre wired and including connecting up with three core 1.5 sqmm flexible copper conductor cable including disconnecting and taking down existing light fitting and removal complete all as specified and directed.
Supply and fixing of LED security light luminaire 30 watt , pressure die cast aluminum housing, toughened heat resistant glass, IP65 protection, better optics for uniform distribution with multiplte LEDs not less than 2 W each hand having optical grade polycarbonate lens with minimum 4 hours battery back up all accessories internally pre wired and including connecting up with suitable size copper conductor cable from connector to ceiling rose to connection of light including disconnecting and taking down old unserviceable security light fitting of any description and in any position complete all as specified and directed.
Supply and fixing of LED security light luminaire 45 watt , pressure die cast aluminum housing, toughened heat resistant glass, IP65 protection, better optics for uniform distribution with multiplte LEDs not less than 2 W each and having optical grade polycarbonate lens with all accessories internally pre wired and including connecting up with two core 1.5 sq mm copper conductor cable from connector to ceiling rose to connection of light including disconnecting and taking down old unserviceable security light fitting of any description and in any position complete all as specified and directed.
Disconnecting and taking down old existing wall fitting of any description and in any position and supply and fixing wall mounting bracket typr wooden base with finished and disgnied cover of V/opal/spherical shape with and including 9 to 12 watt LED lamp of B22 base including connecting up with three core 1.5 sqmm flexible copper conductor cablecomplete all as specified and as directed.
Disconnecting and taking down old existing wall fitting of any description and in any position and Supply and fixing surface mounted type metal base with finished and disgnied diffuser of round/ square/ oval shape slim down lighter 12 watt LED including suitable capacity driver complete connecting up with three core 1.5 sqmm flexible copper conductor cable complete all as specified and as directed.
Supply and fixing of sheet metal enclosures vertical distribution board VTPN, (MCCB DB) 4 ways, double door, 415 volts with 200 amps rated bus bar IP 54 protection, with shrouded neutral bar and insulated bus bar and earth link, with and including MCCB 4 pole thermal release type, 125 Amps, 25 KA as incomer and MCBs as out going complete with making suitable size of MS cabinet 2 mm thick dully grouted on the wall (flush) with opening arrangement including making connections with suitable size of lugs/thimbles/glands and making good the disturbed surface matching with existing surface including taking down existing unserviciable MCCB/DBs including MCBs complete all as specified and directed.
Supply and fixing of sheet metal enclosures distribution board for TPN, (MCB DB) 4 ways, double door , 415 volts with 200 amps rated bus bar IP 54 protection, with shrouded neutral bar and insulated bus bar and earth link, suitable for MCB 4 pole as incomer and MCB s as out going complete with making suitable size of MS cabinet 2 mm thick dully grouted on the wall (flush) with opening arrangement including making connections with suitable size of lugs/thimbles/glands and making good the disturbed surface matching with existing surface including taking down existing unserviciable MCB/DBs including MCBs complete all as specified and directed.
Supply, installation, testing of SPN distibution board 12 way,double door, IP-54, as per IS 8623 including 200 Amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles/glands including taking down existing unserviciable MCB/DBs including MCBs complete all as specified and directed.
Supply, installation, testing of SPN distibution board 8 way,double door , IP 43, as per IS 8623 including 200 Amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, gasket, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles/glands including taking down existing unserviciable MCB/DBs including MCBs complete all as specified and directed.
Supply, installation, testing of SPN distibution board 4 way,double door , IP 43, as per IS 8623 including 200 Amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, gasket, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles/glands including taking down existing unserviciable MCB/DBs including MCBs complete all as specified and directed.
Supply and fixing of MCB single pole, 240 volts, 50Hz , breaking capacity 10KA, 'B' curve 6 to 32 Amps, including connection with suitable size copper lugs complete all as specified and directed.
Supply and fixing of MCB single pole, 240 volts, 50Hz , breaking capacity 10KA, 'B' curve 40 to 63 Amps, including connection with suitable size copper lugs complete all as specified and directed.
Supply and fixing of MCB single pole and neutral, 240 volts, 50Hz , breaking capacity 10KA, 'B' curve 16 to 32 Amps, including connection with suitable size copper lugs complete all as specified and directed.
Supply and fixing of MCB single pole and neutral, 240 volts, 50Hz , breaking capacity 10KA, 'B' curve 40 to 63 Amps, including connection with suitable size copper lugs complete all as specified and directed.
Supply and fixing in repair MCB four pole, 240 volts, 50Hz , breaking capacity 10KA, 100 AMP including connection with suitable size copper lugs complete all as specified and directed.
Supply and fixing in repair MCB four pole, 240 volts, 50Hz , breaking capacity 10KA, 40A to 63 Amps including connection with suitable size copper lugs complete all as specified and directed.
Supply and fixing in repair house service bracket (hook type complete with 3.0m long G.I. pipe 40mm dia medium grade, two nos 90º bends M.S. hook and stay or guy complete all as specified and directed.
Material and labour for concealed sub main wiring with two single core FRLSH PVC insulated unsheathed copper conductor cable 2.5 sqmm drawn in and including rigid non metallic PVC medium grade 25 mm dia concealed conduit with accessories on wall or ceiling with one additional PVC insulated , stranded copper conductor FRLSH of 2.5 sqmm, green colour for earth continuity conductor including taking down old unserviceable sub main wiring and making good the disturbed surface complete all as specified and directed. NOTE : - 3 run of cable and 1 run of conduit shall be measured as 1 unit. (ii) The quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of sub main wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using necessary aceessories/fittings.
Material and labour for concealed sub main wiring with two single core FRLSH PVC insulated unsheathed copper conductor cable 4.00 sqmm drawn in and including rigid non metallic PVC medium grade 25 mm dia concealed conduit with accessories on wall or ceiling with one additional PVC insulated , stranded copper conductor FRLSH of 4.00 sqmm, green colour for earth continuity conductor including taking down old unserviceable sub main wiring and making good the disturbed surface complete all as specified and directed. NOTE : - 3 run of cable and 1 run of conduit shall be measured as 1 unit. (ii) The quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of sub main wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using necessary aceessories/fittings.
Material and labour for concealed sub main wiring with two single core FRLSH PVC insulated unsheathed copper conductor cable 6.00 sqmm drawn in and including rigid non metallic PVC medium grade 25 mm dia concealed conduit with accessories on wall or ceiling with one additional PVC insulated , stranded copper conductor FRLSH of 6.00 sqmm, green colour for earth continuity conductor including taking down old unserviceable sub main wiring and making good the disturbed surface complete all as specified and directed. NOTE : - 3 run of cable and 1 run of conduit shall be measured as 1 unit. (ii) The quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of sub main wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using necessary aceessories/fittings.
Material and labour for concealed sub main wiring with four single core FRLSH PVC insulated unsheathed copper conductor cable 10.00 sqmm drawn in and including rigid non metallic PVC medium grade 40 mm dia concealed conduit with accessories on wall or ceiling with one additional PVC insulated , stranded copper conductor FRLSH of 10.00 sqmm, green colour for earth continuity conductor including taking down old unserviceable sub main wiring and making good the disturbed surface complete all as specified and directed. NOTE : - 5 run of cable and 1 run of conduit shall be measured as 1 unit. (ii) The quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of sub main wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using necessary aceessories/fittings.
Supply and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of size 10 Sqmm including all incoming and outgoing connection with proper size of thimble including disconnecting and taking down existing cables etc. complete all as directed and specified.
Supply and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of size 16 Sqmm including all incoming and outgoing connection with proper size of thimble including disconnecting and taking down existing cables etc. complete all as directed and specified.
Material and labour for taking down ceiling fan of any size/ sweep after disconnecting the wire from existing ceiling rose dismentaling of blades and deposited to store for repair all as specified and directed.
Supply and fixing of fan condencer 2.5/ 4 MFD, 240 volts suitable capacity for ceiling/ exhaust Fan all as specified and directed.
Supply and fixing of ball bearing of suitable size and capacity for ceiling/ Exhaust fan all as specified and directed.
Supply and fixing of hanging assymbly set comprising with rubber reel, MS clamps, nuts, bolts with one lock hole and lock pins suitable for any type of fans & down rods complete all as specified and directed.
Material and labour for painting of ceiling fan using synthetic enamel paint in two coats over one coat of primer of any make/sweep/model etc after cleaning/washing and fill up cavities using filler including writing MES NO Black Colour complete all as specified and directed.
Material and labour for hanging only ceiling fan any type/ sweep after repair and connecting up including provision of cable from ceiling rose to connector to fan including refixing of blades all as specified and directed.
Material and labour for rewinding of ceiling fan of any size with super enameled copper wire of existing gauge incuding varnishing and drying complete reassembling & testing complete of size 1200/ 1400 mm sweep complete all as specified and directed. NOTE for item Nos 61.00 to 67.00 : - (i) Fans to be repaired/ rewinded will be handed over to contractor at MES store yard after cutting the burnt winding in presence of Engr-in-charge and cost of cutting of winding shall be included in the quoted rate. (ii) The cost of shifting the fan from MES store yard to contractors workshop and back shall be included in the item. (iii) Fans will be issued to the contractor in lots of 10 Nos and more for which, contractor shall ensure that minimum lot of 10 number each be returned to the department on every fifth day from the issue of fans after carried out rewinding and other repair, in failing so, the amount @ Rs. 20/- per fan per day shall be deducted from the contractor due till the returning of fan duly tested.
Material and labour for taking down Exhaust fan of any size/ sweep after disconnecting the wire from existing ceiling rose dismentaling of blades and deposited to store for repair all as specified and directed.
Material and labour for rewinding of exhaust fan of any size with super enameled copper wire of existing gauge incuding varnishing and drying complete reassembling & testing complete of size 230 to 450 mm sweep complete all as specified and directed. NOTE for item No 62.00, 68.00 to 72.00 : -(i) Fans to be repaired/ rewinded will be handed over to contractor at MES store yard after cutting the burnt winding in presence of Engr-in-charge and cost of cutting of winding shall be included in the quoted rate. (ii) The cost of shifting the fan from MES store yard to contractors workshop and back shall be included in the item. (iii) Fans will be issued to the contractor in lots of 10 Nos and more for which, contractor shall ensure that minimum lot of 10 number each be returned to the department on every fifth day from the issue of fans after carried out rewinding and other repair, in failing so, the amount @ Rs. 20/- per fan per day shall be deducted from the contractor due till the returning of fan duly tested.
Supply and fixing of metal fan blade including fixing mountings and accessories of exhaust fan of 230 to 450 mm sweep complete all as specified and directed.
Supply and fixing of plastic body exhaust fan, AC singal phase, 240 volts of size 230 mm sweep with heavy duty, plastic body with louvers connecting up including provision of fixing clamp, nut bolts and cable from ceiling rose or connector to fan,including taking down old unserviceable pastic body exhaust fan complete all as specified and directed.
Material and labour for fixing only exhaust fan any type/ sweep after repair and connecting up including provision of cable from ceiling rose to connector to fan including refixing of blades, louvers etc all as specified and directed.
Taking down old unserviceable geyser of cap 25 ltrs including all necessary electrical/water connection and keeping in safe custody for reuse inciuding all necessary minor repairs /servicing etc and checking serviceability of parts, necessary cleaning & reassembling the geyser, making necessary adjustment and refixing the repaired geyser in position, connecting to existing electric & water connections and testing at site complete all as specified and directed. Note : The cost of minor repair including following works deemed to be included in quoted rates. (a) Inspection of geyser after opening bottom cover plate. (b) Examine any water leakage from geyser/storage tank. (c) Carry out operation of all stop cocks, pressure reducing valves, etc. to ensure free movement of the working parts. (d) Replace washers and glands to ensure smooth functioning. (e) Inspect vent pipes and remove blockage obstruction if any. (f) Check and correct earth continuity of electrical items. (g) Check and correct temperature setting of thermostats. (h) Items reqd for replacement will measured under respective item 74 to 84 of BOQ' as "Supply only".
Supply and fixing of copper cable PVC insulated and PVC sheathed flexible size 2.5Sqmm 3 core complete all as specified and directed. (Cable shall be in suitable length as per site requirement).
Supply only heating element of capacity 2 KW of geyser of any approved make ISI marked complete all as specified and directed.
Supply only apparatus plate assembly with rubber gasket including nuts, bolts, washers for geysers of 35/25 ltrs capacity complete all as specified and directed.
Supply only thermostat ISI marked suitable for the Geysers 25 ltrs capacity, 20 Amps, 240 Volts AC, adjustable type, 210 mm long or nearest size as per sample complete all as specified and directed.
Supply only PVC connections pipe with brass hexagonal adapters both side suitable for 15mm dia pipe 60cm long for cold water as per requirement complete all as specified and directed.
Supply only temperature resistent SS braided pipe suitable to sustaine pressure up to 8 bar not less than 60 Cm long suitable for out going / Hot water connections of Geyser with washer etc. complete as an directed.
Supply only Non-return valve 15mm / 20mm dia of brass ISI marked as per requirement complete all as specified and directed.
Supply only Indicators of Geysers of any capacity/type (Red & Green) as per requirement complete all as specified and directed.
Supply only 3 pin plug top, 16 amp capacity, 240 VAC, heavy duty, ISI marked complete all as specified and directed.
Supply only Geyser storage inner tank made out copper sheet suitable for 25 ltrs capacity complete all as specified and directed.
Supply only safety valve plug made out brass metal with fusible lead, inner thread type suitable for geyser of any type/capacity complete all as specified and directed.
Supply and fixing in repair of sheet metal enclosure SP with two pin and earth plug and socket with one single pole, MCB 20 Amps, 'B' curve, 240 volts complete all as specified and directed.
Material and labour only for repair/replacement of unserviceable electrical fitting and fixture and emergent fault rectification in electrical circuit including no light, earth leakage, short circuit, neutral break mains /sub mains/internal circuits of existing system of main building / block ,making continious electric supply including carrying out minor repairs etc as required to make system in order / functional by replacing, copper cable, copper thimbles, glands, earthing wire complete all as specified and directed.as reqd at site by Engineer-in-Charge. NOTE: - (a) Items reqd for replacemen such as switchs, sockets for power/light/ fan/ bell/geyser points including security lights complete will be measured and paid under respective items No 87 to 103 of BOQ' as "Supply only". (b) Contractor rep/supervisor will report to MES Service Centre alongwith reqd sufficient skilled/unskilled manpower between 930 Hrs to 1030 Hrs on all working days. for carrying out necessary execution. (c) Contractor will attend emergent nature of work i.e. no light, short circuit after working hours/holiday. The rate of the is deemed to be included in above quoted rates.
Supply only switch piano 5 Amps, flush type, single pole, one way, 230 volt, AC supply, ISI Marked, complete all as specified and directed.
Supply only switch piano 15 Amps flush type one way 230 Volts, 50 Hz , AC supply, ISI Marked, complete all as specified and directed.
Supply only bell push 5 Amps, flush type, single pole, one way, 230 volt , AC supply, ISI Marked, complete all as specified and directed.
Supply only socket outlet 3 pin 6 amps, 230 volt. flush type, ISI Marked, complete all as speciied and directed.
Supply only socket outlet 2 in 1, 6 pin 5 /16 Amp and multi pin flush type, complete all as specified and directed.
Supply only ceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified and directed.
Supply only fan regulator/ Dimmer electronic step type ,230 Volts, AC supply, suitable for ceiling fan any type/make/sweep, complete all as specified and directed.
Supply only door bell electric ,ding dong /musical| type, single phase 230 volts, ISI marked complete all as specified and directed.
Supply only lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings, complete all as specified and directed.
Supply only Fan condenser 2.5 mfd complete all as specified and directed.
Supply only modular switches, 6 amps, one way single module, 230V, 50 Hz supply sutaible for replacement of existing make and type complete all as specified and directed.
Supply only modular switches, 16 amps, one way single module, 230V, 50 Hz supply sutaible for replacement of existing make and type complete all as specified and directed.
Supply only modular socket, 6 amps, one way single module, 230V, 50 Hz supply sutaible for replacement of existing make and type complete all as specified and directed.
Supply only modular socket, 16 amps, one way single module, 230V, 50 Hz supply sutaible for replacement of existing make and type complete all as specified and directed.
Supply only modular plate alon with base plate and accessories ranging from two to eighteen modile, AC supply for replacement of existing make and type complete all as specified and directed.
Supply only PVC insulated, unsheathed cable 2.5Sqmm 3 core 1100 volt gradewith multistarended copper conductor complete all as specified and directed.
Supply only PVC copper consuctor flexible twin core 0.75qmm complete all as specified and directed.
Supply and fixing in repair of sheet metal enclosure SP with two pin and earth plug and socket with one single pole, MCB 32 Amps, 'C' curve, 240 volts complete all as specified and directed.
Taking out old unserviceable earthing and material & labour for earthing with Galvanised Steel earth plate electrode 60cm x 60cm x 6.0 mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanised Iron wire 4 mm as earthing lead (upto terminal point) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 15 mm dia GI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel , wire mesh, 50 mm thick precast RCC 1:2:4 type B1using 20 mm graded stone aggregate , reinforced with 8 mm dia dedormed /TMT bars 3 nos both way 12 mm dia round bar handle and PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type of soil , returning , filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 3 of SSR 2009(Part-I) complete all as specified and as directed. Note :- (i) Earth lead wire and its protection pipe upto and including 7.50 mtr only from top of earth electrode are included under this item. (ii) On testing if the earth resistance is not obtained within permissible limit, earthing will be re-done at NO extra cost ,till the desired earth resistance is obtained. (iii) Any joint in earth lead from earth electrode to test point shall not be allowed/permitted.
NOTE:- Amount of credit of Rs. 97,211.00 for retrieved materials is mentioned in Schedule of Credit Page No 19 of tender documents in pdf form which will be deducted offline while acceptance of tender.
JS CONSTRUCTION COMPANY
Phoenix Engineers and Erectors
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .