GENERAL
15 conditions · 4 needing a document upload
(As per advance correction slip No.1 of GCC April 2022) The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB of GCC-April-2022 along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Annexure V :- As per Clause 6.1 Part-1 of GCC- The tenderer shall submit a copy of certificate (Enclosed as Annexure-V) stating that all their statements/documents submitted alongwith bid are true and factual. Non submission of above certificate by the bidder shall result in summarily rejection of his/their bid.
The minimum Eligibility Criteria: for costing more than 50 lakhs :- Applicable. 10. Eligibility Criteria: 10.1 Technical Eligibility Criteria: (a) The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii) One similar work costing not less than the amount equal to 60% of advertised value of the tender. (b)(1) In case of tenders for composite works (e.g. works involving more than one distinct component, such as Civil Engineering works, S&T works, Electrical works, OHE works etc. and in the case of major bridges - substructure, superstructure etc.), tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of each component of tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of each component of tender, or (iii) One similar work each costing not less than the amount equal to 60% of advertised value of each component of tender. Note for b (1): Separate completed works of minimum required values shall also be considered for fulfillment of technical eligibility criteria for different components. (b)(2)In such cases, what constitutes a component in a composite work shall be clearly pre-defined with estimated tender cost of it, as part of the tender documents without any ambiguity. (b) (3) To evaluate the technical eligibility of tenderer, only components of work as stipulated in tender documents for evaluation of technical eligibility, shall be considered. The scope of work covered in other remaining components shall be either executed by tenderer himself if he has work experience as mentioned in clause 7 of the Standard General Conditions of Contractor through subcontractor fulfilling the requirements as per clause 7 of the Standard General Conditions of Contract or jointly i.e., partly himself and remaining through subcontractor, with prior approval of Chief Engineer in writing. However, if required in tender documents by way of Special Conditions, a formal agreement duly notarised, legally enforceable in the court of law, shall be executed by the main contractor with the subcontractor for the component(s) of work proposed to be executed by the subcontractor(s), and shall be submitted along with the offer for considering subletting of that scope of work towards fulfilment of technical eligibility. Such subcontractor must fulfill technical eligibility criteria as follows: The subcontractor shall have successfully completed at least one work similar to work proposed for subcontract, costing not less than 35% value of work to be subletted, in last 5 years, ending last day of month previous to the one in which tender is invited through a works contract. Note: for subletting of work costing up to Rs 50 lakh, no previous work experience of subcontractor shall be asked for by the Railway. In case after award of contract or during execution
Note for Item 10.1: Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organisation, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate. 10.1Definition of similar works : The criteria for similar nature of work for said tender is given below as CEE/JBP's L. No. WCR/L/10/Similar Nature/3689, dtd. 11.04.2012. similar nature of work criterion for Electrical General Service (GS) for Electrification work in Electrical department of WCR shall include works executed with Central Government, Semi Government/PSUs of Central Government and/or State Governments have been defined as under :- (A)The level of skills required in following work of electrification is almost same. (a) Electrification of service buildings. (b) Electrification of staff quarters, offices. (c) Electrification of offices. (d) Electrification of road & colony lighting. (e) Electrification of circulating area lighting. (f) Erection & commissioning of LT, HT upto 33 kV overhead mains. (g) Sub-station installations & commissioning. (h) Electrification of washing pits, Sheds & Workshops etc. (i) Any above work or combination of (a) to (h) above.
32 conditions · 3 needing a document upload
Labour Cooperative Societies shall submit only 50% of bid security for which the tenderers are required to upload Registration certificate issued by appropriate authority without which their offer will not be considered. Such firms should also declare that -" We are a Labour Cooperative Society and our Registration No. is .................... with .......................and hence required to deposit only 50% of Bid Security
Any firm recognized by Department of Industrial Policy and Promotion (DIPP) as 'Startups' shall be exempted from payment of Bid Security on submission of Registration Certificate issued by appropriate authority. For such firms it is required to upload a copy of Registration Certificate issued by appropriate authority without which their offer will not be considered. Such firms should also declare that - I/We am/are a Startup firm registered by ........................ Department of Industrial Policy and Promotion (DIPP) and my registration number is ................ valid up to ...................... (Copy enclosed) and hence exempted from submission of Bid Security.
THE OFFERS WITHOUT EARNEST MONEY EXCEPT IN CASE OF EXEMPTION CLAIMED AS PER COMMERCIAL COMPLIANCE OF NIT WILL BE SUMMARILY REJECTED.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Performance Guarantee: - Additional 5% PG to besubmitted if tender awarded more than 5% below(Ref : para-4 of Rly. Bd. L.No.2022|CE-UCTIGCC2022[POLICY/Pt.I (E-3320424), Dated13.03.2026.
Kota Division- Provision and improvement of lighting, charging points, pre-cooling facility and related electrical works and Interlocking of non- interlocked LC gate having TUV more than 20000 on Kota division" (LC-06, LC-55 & LC-66 of KOTA-COR section.) and KOTA-COR SECTION - Provision of Pump & related Electrical work for Water Supply Arrangement
EL-50-313-2026-27~WCR
EL-50-313-2026-27
Open
Works - General
6 Months
Kota, Rajasthan
₹0
₹1.6 L
20 Jul 2026
25 Jun 2026
6 Jul 2026
133 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 80,49,558.5 | ||
| — | 28.00 | — | — | ||
| Supply of material and manufacturing of pre-cooling cum battery charging switch board cabinet with accessories as per Drg. No. DRM/EL/G/2051 of Sr.DEE/G-Kota and technical specification as per explanatory notes. | — | — | — | 7,13,123.04 | |
| — | 28.00 | — | — | ||
| Erection, testing & commissioning of pre-cooling cum battery charging switch board cabinet with accessories as per Drg. No. DRM/EL/G/2051 of Sr.DEE/G-Kota and technical specification as per explanatory notes. | — | — | — | 79,240 | |
| — | 1222.00 | — | — | ||
| Supply of LED pit light as per explanatory notes. | — | — | — | 26,63,862.24 | |
| — | 1222.00 | — | — | ||
| Installation, testing and commissioning of LED pit light as per explanatory notes. | — | — | — | 3,67,699.8 | |
| — | 26.00 | — | — | ||
| Supply and fabrication of Octagonal pole of 3.5 meter (approx.) height Double ArmeType capable of fixing of LED light fitting and should have in built junction box. The material should be of relevant IS and design as per site conditions (Note:- Design should be approved by railways before supply by competent authority.). The Pole should becomplete in all respect as per explanatory notes. | — | — | — | 1,82,024.18 | |
| — | 26.00 | — | — | ||
| Erection, testing and commissioning of Octagonal pole of 3.5 meter (approx.) height Double ArmeType capable of fixing of LED light fitting and should have in built junction box. The material should be of relevant IS and design as per site conditions (Note:- Design should be approved by railways before supply by competent authority.). The Pole should becomplete in all respect as per explanatory notes. | — | — | — | 20,280 | |
| — | 172.00 | — | — | ||
| Supply of LED FLOOD Light Fitting 150 watt complete suitable for 230 V AC 50 HZ. | — | — | — | 2,23,600 | |
| — | 172.00 | — | — | ||
| Installation, testing and commissioning of LED FLOOD Light Fitting 150 watt complete suitable for 230 V AC 50 HZ. | — | — | — | 51,754.8 | |
| — | 11250.00 | — | — | ||
| Laying of circular armoured XLPE LT cable aluminum conductor 1100 volt with connection etc. (Note : Cable will be supplied by Railway.) | — | — | — | 2,86,425 | |
| — | 120.00 | — | — | ||
| Digging of trench in pucca trench in yard /platform 50cm. deep and 35cm. wide including replaster on surface by cement oncrete after laying of cable. | — | — | — | 27,226.8 | |
| — | 1200.00 | — | — | ||
| Digging of trench in all type of soils/road cutting 100 cm. deep and 50cm. wide including supply and laying of "B" class bricks on both side & top of the cable and refilling the trench after laying of cable. | — | — | — | 1,70,808 | |
| — | 120.00 | — | — | ||
| Supply of material of RCC hume pipe 6" dia (150mm) as per IS: 456-1978 or latest in existing trench under Railway track including jointing and all required accessories etc. | — | — | — | 53,264.4 | |
| — | 120.00 | — | — | ||
| Laying of RCC hume pipe 6" dia (150mm) as per IS: 456-1978 or latest in existing trench under Railway track including jointing and all required accessories etc. | — | — | — | 6,480 | |
| — | 50.00 | — | — | ||
| Supply of heavy-duty ISI marked B class GI pipe of 3.65 mm wall thickness & 50 mm diameter to be laid along the wall or floor with proper galvanized clamp through the wall or underneath the floor in cement concrete. | — | — | — | 16,569 | |
| — | 50.00 | — | — | ||
| Laying & fixing of heavy-duty ISI marked B class GI pipe of 3.65 mm wall thickness & 50 mm diameter to be laid along the wall or floor with proper galvanized clamp through the wall or underneath the floor in cement concrete. | — | — | — | 4,100 | |
| — | 20.00 | — | — | ||
| Supply of heavy duty ISI marked B class GI pipe of 80 mm diameter with suitable clamps on rail/pole/joists with nut/bolts and GI socket as per site requirement. | — | — | — | 9,733 | |
| — | 20.00 | — | — | ||
| Laying & fixing of heavy-duty ISI marked B class GI pipe of 80 mm diameter with suitable clamps on rail/pole/joists with nut/bolts and GI socket as per site requirement. | — | — | — | 2,400 | |
| — | 32.00 | — | — | ||
| Supply of material & providing GI. pipe earthing arrangement by digging the pit as per DRM/KTT's Drg. No. 01913EL/R1 or latest complete in all type of soils including rocky area. Earth value will be taken by the contractor in the presence of Railway representative and written on the earth pit by the contractor. | — | — | — | 90,453.12 | |
| — | 600.00 | — | — | ||
| Supply of material and wiring, testing and commissioning of sub main phase and neutral in PVC rigid conduit pipe size 25 mm dia. medium class mark with 4 sq.mm. PVC insulated single core multistransd copper cable with 2.5 sq.mm. PVC insulated copper wire green coloured for earthing and connection etc. Separate PVC pipe to be provided for this item. | — | — | — | 47,112 | |
| — | 1000.00 | — | — | ||
| Supply of Cable tray made out from MS angle 50X50X6mm and MS flat 50X6mm as mentioned technical specifications. The work also includes the fixing of cable tray at specified location on RCC column with appropriate clamps, nut, bolts etc. This involves supply of cable trays(cradle) by fabricating 50x50x6 mm MS angles (on both side and MS flats of size 50x6mm of width 400mm shall be on cable tray the cable tray shall be straight, painted with 2 coats of each primer and synthetic paint (preferably black). The MS flat of 400 mm length shall be welded in such fashion so that 15 cms gap is maintained so that about 6 nos such flats are welded per meter. Erection involves its fabrication of the tray on the already provided channels RCC pillar. The cable tray is to be firmly fixed on the RCC pillars to cater all the weight of the different types of cable which are laid on the cable tray. For fixing of the cable tray suitable clamps/brackets of adequate dimensions are to be used at proper interval and to be fixed on the RCC pillar and with the cable tray up to the satisfaction of the Railway Engineer. (Note: - Before starting the work, the sample should be got approved by the Railways) | — | — | — | 7,87,740 | |
| — | 1000.00 | — | — | ||
| Fixing of Cable tray made out from MS angle 50X50X6mm and MS flat 50X6mm as mentioned technical specifications. The work also includes the fixing of cable tray at specified location on RCC column with appropriate clamps, nut, bolts etc. This involves supply of cable trays(cradle) by fabricating 50x50x6 mm MS angles (on both side and MS flats of size 50x6mm of width 400mm shall be on cable tray the cable tray shall be straight, painted with 2 coats of each primer and synthetic paint (preferably black). The MS flat of 400 mm length shall be welded in such fashion so that 15 cms gap is maintained so that about 6 nos such flats are welded per meter. Erection involves its fabrication of the tray on the already provided channels RCC pillar. The cable tray is to be firmly fixed on the RCC pillars to cater all the weight of the different types of cable which are laid on the cable tray. For fixing of the cable tray suitable clamps/brackets of adequate dimensions are to be used at proper interval and to be fixed on the RCC pillar and with the cable tray up to the satisfaction of the Railway Engineer. (Note: - Before starting the work, the sample should be got approved by the Railways) | — | — | — | 89,860 | |
| — | 500.00 | — | — | ||
| Supply of Junction box of polycarbonate with IP-66/67 protection halogen free and weather proof having minimum dimensions 205X255X112 mm, fire retardant, antacid & anticorrosive suitable for multiple connection of 4 core cable as mentioned below- The work includes the supply & erection of thermoplastic polycarbonate junction box having specified minimum dimensions with multilevel knockouts for cable glands. The junction box shall have IP66 degree of protection, polyurethane gasket and weather proof, UV resistant, temperature resistance, fire retardant and anticorrosive suitable for multiple connection of 4 core cable. The junction box is to be fixed at the location identified by the Railway Engineer with suitable clamps, fixtures, nut & bolts etc, so as to firmly fixed on the wall/RCC pillar. | — | — | — | 11,90,590 | |
| — | 500.00 | — | — | ||
| Fixing of Junction box of polycarbonate with IP-66/67 protection halogen free and weather proof having minimum dimensions 205X255X112 mm, fire retardant, antacid & anticorrosive suitable for multiple connection of 4 core cable as mentioned below- The work includes the supply & erection of thermoplastic polycarbonate junction box having specified minimum dimensions with multilevel knockouts for cable glands. The junction box shall have IP66 degree of protection, polyurethane gasket and weather proof, UV resistant, temperature resistance, fire retardant and anticorrosive suitable for multiple connection of 4 core cable. The junction box is to be fixed at the location identified by the Railway Engineer with suitable clamps, fixtures, nut & bolts etc, so as to firmly fixed on the wall/RCC pillar. | — | — | — | 59,900 | |
| — | 200.00 | — | — | ||
| Dismantling of old junction box, charging box and deposit in store. | — | — | — | 11,980 | |
| — | 1200.00 | — | — | ||
| Dismantling of old cable & cable tray and deposit in store. | — | — | — | 30,768 | |
| — | 90.00 | — | — | ||
| Digging of the trench and refilling after laying of pipe under track at the depth of 1 meter from the formation level etc. | — | — | — | 14,211 | |
| — | 87.00 | — | — | ||
| Supply of LED tube light Box type Luminaire 20 watt complete with tube suitable for 230 V AC. | — | — | — | 30,418.68 | |
| — | 87.00 | — | — | ||
| Fixing, testing & commissioning of LED tube light Box type Luminaire 20 watt complete with tube suitable for 230 V AC. | — | — | — | 4,350 | |
| — | 21.00 | — | — | ||
| Supply of BEE 5 star rated energy efficient BLDC ceiling fan, sweep size: 1200mm, complete with wiring connection etc. as per detailed specification attached. | — | — | — | 56,634.48 | |
| — | 21.00 | — | — | ||
| Erection and fixing of BEE 5 star rated energy efficient BLDC ceiling fan, sweep size: 1200mm, complete with wiring connection etc. as per detailed specification attached. | — | — | — | 4,200 | |
| — | 3.00 | — | — | ||
| Supply of wall mounted bracket fan sweep 400 mm suitable for 230 volts, 50 hz moving type with regulator and control switch on & off with accessories. | — | — | — | 5,148.87 | |
| — | 3.00 | — | — | ||
| Fixing of wall mounted bracket fan sweep 400 mm suitable for 230 volts, 50 hz moving type with regulator and control switch on & off with accessories. | — | — | — | 300 | |
| — | 9.00 | — | — | ||
| Supply of exhaust fan sweep size 300 mm suitable for 230-volt AC 50 Hz complete with accessories. | — | — | — | 10,400.67 | |
| — | 9.00 | — | — | ||
| Fixing, testing & commissioning of exhaust fan sweep size 300 mm suitable for 230- volt AC 50 Hz complete with accessories. | — | — | — | 867.96 | |
| — | 6.00 | — | — | ||
| Supply of materials of main distribution box 10 way suitable for housing MCB and ELCB with copper busbar and neutral link. Distribution box should be fixed on wooden taper plug or steel fasteners etc. with providing and fixing of 01 no. MCB DP 32 Amp. breaking capacity 6 KA and 06 Nos. MCB SP 6-32 Amp. breaking capacity 6 KA with 01 No. ELCB 40 Amp. DP, sensitivity 100 m. Amp. and connections etc. The distribution board is to be fixed on wall with the help of rag bolt /fastener or on board and connecting the same with suitable size of wire duly crimped lugs. | — | — | — | 29,743.08 | |
| — | 6.00 | — | — | ||
| Erection and fixing of main distribution box 10 way suitable for housing MCB and ELCB with copper busbar and neutral link. Distribution box should be fixed on wooden taper plug or steel fasteners etc. with providing and fixing of 01 no. MCB DP 32 Amp. breaking capacity 6 KA and 06 Nos. MCB SP 6-32 Amp. breaking capacity 6 KA with 01 No. ELCB 40 Amp. DP, sensitivity 100 m. Amp. and connections etc. The distribution board is to be fixed on wall with the help of rag bolt /fastener or on board and connecting the same with suitable size of wire duly crimped lugs. | — | — | — | 3,310.2 | |
| — | 9.00 | — | — | ||
| Supply of materials of main distribution box 4+2 way suitable for housing MCB and ELCB with neutral link. Distribution box should be fixed on wooden taper plug or steel fasteners etc. with supply and fixing of 01 no. MCB SPN 16 Amp. breaking capacity 10 KA and 02 Nos. MCB SP 6-32 Amp. breaking capacity 10 KA with 01 No. ELCB 25 Amp. DP, sensitivity 30 m. Amp. and connections etc. The distribution board is to be fixed on wall with the help of rag bolt /fastener or on board and connecting the same with suitable size of wire duly crimped lugs. | — | — | — | 35,087.04 | |
| — | 9.00 | — | — | ||
| Erection and fixing of main distribution box 4+2 way suitable for housing MCB and ELCB with neutral link. Distribution box should be fixed on wooden taper plug or steel fasteners etc. with supply and fixing of 01 no. MCB SPN 16 Amp. breaking capacity 10 KA and 02 Nos. MCB SP 6-32 Amp. breaking capacity 10 KA with 01 No. ELCB 25 Amp. DP, sensitivity 30 m. Amp. and connections etc. The distribution board is to be fixed on wall with the help of rag bolt /fastener or on board and connecting the same with suitable size of wire duly crimped lugs. | — | — | — | 3,902.85 | |
| — | 117.00 | — | — | ||
| Supply, installation, testing & commissioning of concealed wiring of light/Fan/Bell points in PVC rigid conduit pipe size 25mm dia medium class minimum thickness approx. 1.6mm to 1.8mm of ISI mark with 1.5 sq.mm. multistrand PVC insulated copper conductor cable confirming to IS:694-1990 or latest with one holder/ceiling rose on junction box with round plate with 2.5 sq.mm. PVC insulated copper wire green coloured for earthing along with connection etc. including stone wall cutting, replaster, painting and other civil work | — | — | — | 45,398.34 | |
| — | 1500.00 | — | — | ||
| Supply of material for concealed wiring of sub main phase & neutral in PVC rigid conduit pipe size 25mm dia medium class minimum thickness approx. 1.6mm to 1.8mm of ISI mark with 4 sq.mm. PVC insulated single core multistrand copper cable with 2.5 sq.mm. PVC insulated copper wire green coloured for earthing & connection etc. Separate PVC pipe to be provided for this item. including stone wall cutting, replaster, painting and other civil work | — | — | — | 1,89,090 | |
| — | 1500.00 | — | — | ||
| Erection, testing & commissioning of concealed wiring of sub main phase & neutral in PVC rigid conduit pipe size 25mm dia medium class minimum thickness approx. 1.6mm to 1.8mm of ISI mark with 4 sq.mm. PVC insulated single core multistrand copper cable with 2.5 sq.mm. PVC insulated copper wire green coloured for earthing & connection etc. Separate PVC pipe to be provided for this item. including stone wall cutting, replaster, painting and other civil work | — | — | — | 1,43,925 | |
| — | 12.00 | — | — | ||
| Supply of flush metal box of 2-Module with connection used for concealed modular flush metal box wiring. | — | — | — | 842.4 | |
| — | 12.00 | — | — | ||
| Erection & fixing of flush metal box of 2-Module with connection used for concealed modular flush metal box wiring. | — | — | — | 137.16 | |
| — | 12.00 | — | — | ||
| Supply of plate Inner & Outer 2-Module used for concealed modular wiring. | — | — | — | 1,756.08 | |
| — | 12.00 | — | — | ||
| Erection & fixing of plate Inner & Outer 2-Module used for concealed modular wiring. | — | — | — | 216.96 | |
| — | 6.00 | — | — | ||
| Supply of flush metal box of 4-Module with connection used for concealed modular flush metal box wiring. | — | — | — | 778.08 | |
| — | 6.00 | — | — | ||
| Erection & fixing of flush metal box of 4-Module with connection used for concealed modular flush metal box wiring. | — | — | — | 126.66 | |
| — | 6.00 | — | — | ||
| Supply of plate Inner & Outer 4-Module used for concealed modular wiring. | — | — | — | 1,631.82 | |
| — | 6.00 | — | — | ||
| Erection & fixing of plate Inner & Outer 4-Module used for concealed modular wiring. | — | — | — | 201.66 | |
| — | 9.00 | — | — | ||
| Supply of flush metal box of 8-Module with connection used for concealed modular flush metal box wiring. | — | — | — | 1,587.78 | |
| — | 9.00 | — | — | ||
| Erection & fixing of flush metal box of 8-Module with connection used for concealed modular flush metal box wiring. | — | — | — | 258.39 | |
| — | 9.00 | — | — | ||
| Supply of material & fixing of plate Inner & Outer 8-Module used for concealed modular wiring. | — | — | — | 2,702.34 | |
| — | 9.00 | — | — | ||
| Erection & fixing of plate Inner & Outer 8-Module used for concealed modular wiring. | — | — | — | 315 | |
| — | 126.00 | — | — | ||
| Supply of S.P. switch 6 / 10 Amp. one way (1-Module). | — | — | — | 15,479.1 | |
| — | 126.00 | — | — | ||
| Erection & fixing of S.P. switch 6 / 10 Amp. one way (1-Module). | — | — | — | 2,109.24 | |
| — | 30.00 | — | — | ||
| Supply of blank plates (1-Module) used for concealed modular wiring. | — | — | — | 927.9 | |
| — | 30.00 | — | — | ||
| Erection & fixing of blank plates (1-Module) used for concealed modular wiring. | — | — | — | 102.6 | |
| — | 9.00 | — | — | ||
| Supply of 6 Amp. 5-pin socket (2-Module). | — | — | — | 1,686.6 | |
| — | 9.00 | — | — | ||
| Erection & fixing of 6 Amp. 5-pin socket (2-Module). | — | — | — | 208.44 | |
| — | 9.00 | — | — | ||
| Supply of fan regulator 5-step (2-Module) used for concealed modular wiring. | — | — | — | 6,271.11 | |
| — | 9.00 | — | — | ||
| Erection & fixing of fan regulator 5-step (2-Module) used for concealed modular wiring. | — | — | — | 330.03 | |
| — | 3.00 | — | — | ||
| Supply, installation, testing & commissioning of Energy efficient ISI mark submersible pump motor set 3 HP/23 stage, 220 Volts, H/range 71-136 mtr, discharge - 100 - 33 LPM, Del. 38/40 mm suitable for 100 mm dia bore well, water lubricated type as per explanatory notes. | — | — | — | 66,493.44 | |
| — | 3.00 | — | — | ||
| Supply & fixing of control starter panel with voltmeter 0-300 V, Ammeter 0-30 Amp., indicators, On-Off push button, motor protection overload relay 17-24 Amp., contactor 25 Amp. & suitable for 03 HP single phase submersible motor pump set with starting and running capacitor. | — | — | — | 17,474.16 | |
| — | 700.00 | — | — | ||
| Supply, erection, testing and commissioning of PVC insulated flat three core flexible copper industrial cable for submersible pump motor set 1.1 K.V. grade nominal area of conductor 4.0 sqmm as per latest relevant IS: 694 or latest. | — | — | — | 58,485 | |
| — | 700.00 | — | — | ||
| Supply & fixing of HDPE Pipe outer diameter 40 mm, material grade PE-63, Pressure- 10 PN, ISI Mark, IS: 4984-2016 or latest complete with SS hose nipple and nut bolts etc. | — | — | — | 83,685 | |
| — | 700.00 | — | — | ||
| Supply & fixing of Poly Propylene rope 3 strand hawser laid and 8 stand plited size 16 mm dia Conf. to IS: 14929-2001 along with 42 nos. hardware to secure the complete pump motor to prevent it from falling down in the borewell breaking capacity 3770 Kgf plus minus 6 percent. | — | — | — | 21,770 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .