Loading…
Loading…
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
20 Mar 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
W5
14 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where: V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case the balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB of Part I of GCC, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or One similar work costing not less than the amount equal to 60% of advertised value of the tender.
Definition of Similar work means:- "Any work in connection with Signaling Installation. The work shall have Indoor wiring component also if tendered work involves Indoor wiring alteration in the existing system."
15 conditions · 5 needing a document upload
As per "CHECK LIST" document attached.
Following documents dully flled & signed to be uploaded. Standard formats are provided in (Annexure provided with tender document. Tenders are required for furnish details in thhese format).
"Tender Form" As per 'TENDER FORM" (Ref Standard format provided in Annexures).
Deviation Statement:- The tender shall submit a statement indicating any deviations against any clause of this tender including all the technical specification concerned to this work, duly signed and stamped on each page. If there are no deviation whatsoever, a Nil deviation statement should be submitted. (Ref Standard format provided in Annexures). In case firm has not submitted deviation or blank deviation statement it will be treated as NIL deviation.
List of works completed: list of works completed in the last seven financial years giving description of work, organization for whom executed, approximate value of contract at the time of award, date of award and date of schedule completion of work. Date of actual start, actual start, actual completion and final value of contract should also be given. (Ref Standard format provided in Annexures).
List of works on hand:- List of works on hand indicating description of work, contract value, and approximate value of balance, work yet to be done and date of award (Ref Standard format provided in Annexures).
Details of payment through NEFT/RTGS. (Ref Standard format provided in Annexures).
List of Personnel, organization:- List of Personnel, organization/technical staff available on hand and proposed to be engaged for the subject work, with their designation and experience.
Document for technical skill:- Documentary evidence necessary to establish that they possess the requisite skill, technical expertise, technical and skilled manpower and necessary equipment's to execute complete work covered in the schedule with stipulated specification/details.
Special instruction regarding payment of Bid Security: Excerpt of GCC April -2022 read as ii)Any firm recognized by the Department of Industrial Policy and Promotion (DIPP) as 'Startups' shall be exempted from payment of Bid Security detailed above. iii) Labour Cooperative Societies shall submit only 50% of above Bid Security detailed. (Refer para 7.0 of Chapter II of Tender document) for clarification see GCC April2022
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Part supply of signaling material, installation, testing & commissioning in connection with Interlocking of LC No. 4 at Km. 5/8-9 between Kalol-Adraj Moti section in Ahmedabad Division.
DRM-SnT-ADI-Sig16of25-26
DRM-SnT-ADI-Sig16of25-26
Open
Works - General
12 Months
Ahmadabad, Gujarat
₹0
₹2.2 L
20 Mar 2026
26 Feb 2026
6 Mar 2026
157 items across 4 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 26,50,665.91 | ||
| — | 1.00 | — | — | ||
| Electrically Operated Lifting Barrier complete set suitable for 110VDC/24V DC supply with hand generator back up & motorized boom locking arrangements as per RDSO Spec. SPN/208/2012 with the latest amendment. One set consisting of 02 No.s of Barriers of length 09.76 Mtr. along with Spares & tool kit mentioned in RDSO Spec. SPN/208/2012 clause 10.1 & 10.2. | — | — | — | 4,69,571.95 | |
| — | 1.00 | — | — | ||
| Relay fail safe electronic time delay device mounted on Q series relay base and cover with fixed timing of 60/120 second confirming to IRS:S:61/2000(ver.1.0) (Amdt. 3) or Latest,IRS:S:34 and IRS:S:23 (as applicable). The Interlocking code for this unit shall be AFGKY. | — | — | — | 5,242 | |
| — | 1.00 | — | — | ||
| Relay racks assembly complete with scaffolding bus bars, fuse strips, fuses, resistors, capacitors, insulators, grouting bolts, tripods etc. as per Drg. No. CSTE /6028 .[Scaffolding should include 20% extra (with minimum of 2 relay rack positions) as spare for future expansion]. Relay rack shall be Powder Coated. (Quantity of Resistance, capacitor & Other items as Annexure.) | — | — | — | 26,249.42 | |
| — | 1.00 | — | — | ||
| Cable termination racks as per Drg. no. CSTE 5004, 5005, 5006 complete along with fitting arrangements and also with arrangement for fixing four 8-way terminal strips/ Screw less terminals on each row having 16 such rows. Supply of 8 way terminal strips/ Screw less terminals not covered under this item. Cable termination rack shall be Powder Coated. | — | — | — | 24,008.12 | |
| — | 18.00 | — | — | ||
| Universal AC ECR of Q series, type "QECX61" suitable for AC LED all signal aspect, Front & back contact Metal to Carbon type complete with plug board retaining clip & connectors conforming to Spec STS/E/Relays/AC Lit LED Signal/09/2002, BRS: 941A, IRS: S34 and IRS: S23 (as applicable). | — | — | — | 1,01,035.8 | |
| — | 20.00 | — | — | ||
| Miniature, Plug-in Type, DC Neutral Line AC Immunized Relay, Style QNA1, 24 V DC, 8F-8B/12F-4BContact, Code ABDGH/ABDFH Spec: BRS: 931A; IRS S 34; IRS S 23; IRS S 60-78. | — | — | — | 1,11,520.8 | |
| — | 10.00 | — | — | ||
| DC neutral line relay QNA1K (QSA3), AC immune, DC neutral line 24V, 12F/4B contacts, complete with plug board, retaining clip and connectors. Conforming to BRS930A, (as applicable) IRS: S34& IRS: S23 or latest | — | — | — | 58,594.1 | |
| — | 1.00 | — | — | ||
| Time Element Relay (Clockwork type) AG timer Siemens Make (No RSSK 30/0052). | — | — | — | 6,625.96 | |
| — | 1.00 | — | — | ||
| Earth Leakage Detector as per RDSO/SPN/256/2002 or latest with latest amendments. The basic detector unit shall comprise of 8 channels, for use on signaling circuits of 110V AC/DC and/or 60V/24V/12V DC as ordered by purchaser. If the detector is required for less number of channels, dummy plates shall be provided. For additional requirement add on /expendable cabinet may be used. The voltage specified shall be provided with + 25% and - 10% tolerance. | — | — | — | 1,51,574.89 | |
| — | 1.00 | — | — | ||
| Single core multi-strand wire 0.5 sq.mm. (16 conductor each dia. 0.2mm), as per IRS 76/89 (Amd3) or latest. | — | — | — | 5,548.54 | |
| — | 1.00 | — | — | ||
| Flexible cable (Power wire), multi-strand copper conductors cross section 1x6 Sq.mm. ( 85 conductor each diameter 0.30 +/- 0.01) as per IS 694/1990 with insulation thickness of 0.80 mm nominal conductor resistance 3.30 ohms/km and test parameters are as per IRS(S)76/89 or latest. | — | — | — | 33,366.21 | |
| — | 1.00 | — | — | ||
| PVC insulated Railway Signaling multi-core Indoor Cable 1 mm x 40 mm x 0.6mm Dia conforming toIRS:76/89(Amd3) or latest. | — | — | — | 92,180.73 | |
| — | 50.00 | — | — | ||
| Indicative type Fuse suitable to G type fuse base/holder of capacity 0.63 A - 3.0 A. (System, Rapid, Malnad or RBCO make or similar). | — | — | — | 930 | |
| — | 20.00 | — | — | ||
| D type fuse block non indicating type low voltage non deteriorating fuse base suitable for fuse link of capacity 2A/6A/10A as per specification IRS:S-80/92 or latest Quantity break up of each type of fuse block will be specified by Engineer in-charge. | — | — | — | 638.6 | |
| — | 2.00 | — | — | ||
| Fuse auto changeover system for use in Railway Signaling System as per RDSO/SPN/209/2012 rev.1 with latest amendments. One Automatic changeover Unit comprises 32 nos. of external Non-Deteriorating Type or 'G' type fuses from 0.6 Amp to 4 Amp capacities which are in signaling circuits. The system shall have 8 cards with a monitoring arrangement of 4 fuses in one card. | — | — | — | 59,487.26 | |
| — | 5.00 | — | — | ||
| Miniature 'E' type lock complete with keys as per RDSO Drg. No. SA 3473, 3373 & spec. IRS(S) 30/64. Ward to be specified by Engineer - in - charge. | — | — | — | 10,407.6 | |
| — | 5.00 | — | — | ||
| Key Lock Relay working on 24V DC, AC immunize with different ward combinations (Three ward plates to be supplied with each relay). Key ward shall be specified by engineer incharge as per requirement. | — | — | — | 48,719.85 | |
| — | 6.00 | — | — | ||
| Supply Color Light Signal Accessories. 1. CI Base (As per IRS S-10 & RDSO Drg. No. 2011/M With latest assembly). 2. Pinnacle. 3. Ladder Assembly, as per RDSO Drg. No. SA-23156, with Base, Ladder Guards, Platform, Front Maintenance Platform, MS Supporting bracket to Support Ladder. 4. Signal Front Staging Complete Assembly for CLS Unit. 5. Signal back staging as per extent WR Practice. | — | — | — | 19,507.98 | |
| — | 2.00 | — | — | ||
| Non Metallic (FRP) color light signal housing multi-unit type for railway signaling suitable for RE area TWO Aspects. Complete without lenses, lamps and signal transformer as per RDSO DRG. No. SA 23001/A/M Adv. Alt- S and as per SPEC. No. RDSO/SPN/194/2006 (Vol. 1.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest. | — | — | — | 57,155.44 | |
| — | 2.00 | — | — | ||
| Non Metallic (FRP) color light signal housing multi-unit type for railway signaling suitable for RE area THREE Aspects. Complete without lenses, lamps and signal transformer as per RDSO DRG. No. SA 23001/A/M Adv. Alt- S and as per SPEC. No. RDSO/SPN/194/2006 (Vol.1.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest. | — | — | — | 59,647.82 | |
| — | 2.00 | — | — | ||
| Non Metallic (FRP) color light signal housing multi-unit type for railway signalling suitable for RE area FOUR Aspects. Complete without lenses, lamps and signal transformer as per RDSO Drg.No. SA 23001/A/M Adv. Alt- Sand as per SPEC. No. RDSO/SPN/194/2006 (Vol. 1.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest. | — | — | — | 66,607.72 | |
| — | 15.00 | — | — | ||
| Double Walled Corrugated (DWC) HDPE Pipe with associated collars etc. as per RDSO Specification No. RDSO/SPN/204/2011 or latest anti-rodent & anti-oxidant and non-flame propagating type in 6 meters straight length and of size 120 mm outer die,& 103.5 mm inner dia. . One of the following coupling arrangements should also be supplied with each pipe as per the site requirement. 1) Suitable snap fit coupler with rubber 'O-Ring 2) Spacers 3) Tees 4) Bend, 5) End-cap (The total quantity of above items is equal to no. of pipes supplied.) DWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vender name and year of manufacture can be easily identified. Color -Bright Orange; Min Weight = 4kg. Test Check by Consignee & Sample check by JAG officer. | — | — | — | 28,683 | |
| — | 30.00 | — | — | ||
| Medium Class G.I. Pipes to IS: 1239 (Pt.)-2004 or latest; 100mm dia. (int. Dia) 3.65 mm thick or above with coupling. G.I. pipes shall have ISI mark on it and contractor should submit manufacturer's test certificate of G.I. pipes. | — | — | — | 35,108.4 | |
| — | 6.00 | — | — | ||
| SS Location box made of Spl Grade SS 304 of size as per Drg. No. DRM/SG/948 dt. 26.04.2011 (Single app. Case) or latest. Manufacturer's certificate in regard to grade of stainless steel and its protection level shall be submitted at the time of supply. | — | — | — | 3,59,135.88 | |
| — | 6.00 | — | — | ||
| SS Location box made of Spl Grade SS 304 of size as per Drg. No. DRM/SG/945 dtd 03.03.2011 (Half app. Case) or latest. Manufacturer's certificate in regard to grade of stainless steel and its protection level shall be submitted at the time of supply. | — | — | — | 3,11,988.36 | |
| — | 12.00 | — | — | ||
| IS 13410: Glass Reinforced Polyester Sheet Moulding Compounds (SMC) Size of Sheet : 1000x1000x8 | — | — | — | 64,664.04 | |
| — | 2700.00 | — | — | ||
| ARA Terminal blocks with links made of PBT Spec No.s/75/2006 (Rev - 2) with latest amendments and RDSO Drg.No.SA-23741A Alt.4. | — | — | — | 2,02,500 | |
| — | 5.00 | — | — | ||
| Maintenance Free Earth Electrode of length 3m, including supply of 3 bags of Earth enhancement material for earthling (10KGs /bag) for each electrode & other accessories as per Drg. No. SDO / RDSO/ E&B/001 and RDSO Spec No. RDSO / SPN/197/2008. | — | — | — | 52,015.4 | |
| — | 20.00 | — | — | ||
| Earth Electrode as per Drg. No. CSTE / 6091. | — | — | — | 55,979.8 | |
| — | 1.00 | — | — | ||
| Remote Terminal Unit (RTU) with 64 digital input & 16analog input as per technical specification IRS: S-99 2006(Amdt-3) or latest. In addition RTU should have dual leased line modem. It should possible to connect RTU up to 12 Kms from main data logger. This includes rack for installation & Battery backup for 06 hrs. | — | — | — | 1,31,970.24 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
2RevisedTNo16of2025-26.pdf
ATTACHMENT
3RevisedTNo16of2025-26Annexure.pdf
ATTACHMENT
4SIPOFAJMLC4INTFORTENDERPROPOSEDSIP.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .