Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
26 Apr 2021, 4:00 pmClosed
Executive Engineer ED Kargil
Baroo Kargil
Annual Maintenance repair of HT LT lines and Sub Stations labor component only in Shargole Section of district Kargil.
2021_PDNRE_2759_1
E- NIT NO 06 OF 2021-22
Open Tender
Electrical Works
Item Wise
365 days
KARGIL
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
Executive Engineer Electric Division Kargil
₹50,000
29 Apr 2021
8 Apr 2021
27 Apr 2021
9 Apr 2021
26 Apr 2021
15 Apr 2021
Loading of Poles
ST Pole 8.0m Long
ST Pole 9.0m Long
ST Pole above 10Mtr.
Unloading of pole at road side and its carriage upto 25 Mtr.
ST Pole 8.0m Long
ST Pole 9.0m Long
ST Pole above 10Mtr.
Dragging/ Manual carriage of pole to site of work upto first 100 Mtr.
ST Pole 8.0m Long
ST Pole 9.0m Long
ST Pole above 10Mtr.
Dragging/ Manual carriage of pole to site of work for every subsequent 50 Mtr.
ST Pole 8.0m Long
ST Pole 9.0m Long
ST Pole above 10Mtr.
Loading of line material.
A.C.S.R conductor Squirrel /Weasel /Rabbit /Dog etc.
11KV AB Cable/LT2.5Core/11KV PVC/XPLE Insulated Cable etc.
M.S channel/Angle/Flat/Nuts & Bolts/Guy wire/G.I wire etc.
Polymer/Porcelain items/ Insulator/Disc/Shackle/G.O Set/Link Set/D.O Set/LA etc.
Unloading and manual carriage of line material upto 25 Mtr.
A.C.S.R conductor Squirrel /Weasel /Rabbit /Dog etc.
11KV AB Cable/LT2.5Core/11KV PVC/XPLE Insulated Cable etc.
M.S channel/Angle/Flat/Nuts & Bolts/Guy wire/G.I wire etc.
Polymer/Porcelain items/ Insulator/Disc/Shackle/G.O Set/Link Set/D.O Set/LA etc.
Manual carriage of line material to site of work beyond 25 Mtr. for first 100 Mtr .
A.C.S.R conductor Squirrel /Weasel /Rabbit /Dog etc.
11KV AB Cable/LT2.5Core/11KV PVC/XPLE Insulated Cable etc.
M.S channel/Angle/Flat/Nuts & Bolts/Guy wire/G.I wire etc.
Polymer/Porcelain items/ Insulator/Disc/Shackle/G.O Set/Link Set/D.O Set/LA etc.
Carriage of line material manually to site of work for every additional 50 Mtr or part thereof.
A.C.S.R conductor Squirrel /Weasel /Rabbit /Dog etc.
11KV AB Cable/LT2.5Core/11KV PVC/XPLE Insulated Cable etc.
M.S channel/Angle/Flat/Nuts & Bolts/Guy wire/G.I wire etc.
Polymer/Porcelain items/ Insulator/Disc/Shackle/G.O Set/Link Set/D.O Set/LA etc.
Erection of pole with X-arm/U-Clamp , Top-hamper pin clamp, insulator & braces ( with plantation depth equal ot 1/6th of the pole length) for HT/LT including pit excavation in all soil and Cement Bottoming as per REC Standards ammended upto date.
ST Pole 8 Mtr. Long
ST Pole 9 Mtr. Long
ST Pole 11 Mtr. Long
Erection of pole with X-arm/U-Clamp , Top-hamper pin clamp, insulator & braces ( with plantation depth equal ot 1/6th of the pole length) for HT/LT including pit excavation in all soil and without Cement Bottoming as per REC Standards ammended upto date.
ST Pole 8 Mtr. Long
ST Pole 9 Mtr. Long
ST Pole 11 Mtr. Long
Errection of DP Structure with GI Channel X-arm including clamps and braces (the detail specification of X-arms for DP Structure can be refered from REC Constructional Specifications)
Straightening of tilted pole
ST Pole 8 Mtr. Long
ST Pole 9 Mtr. Long
ST Pole 11 Mtr. Long
Re-erection of uprooted Poles
ST Pole 8 Mtr. Long
ST Pole 9 Mtr. Long
ST Pole 11 Mtr. Long
Laying , Stringing of A.C.S.R Conductor.
A.C.S.R conductor up to 30 mm² (Squirrel / Weasel )
A.C.S.R conductor 50 mm² (Rabbit)
A.C.S.R conductor 100mm² (Dog)
Re-stringing/Tightening of snapped /loose conductor
A.C.S.R conductor up to 30mm² (Squirrel / Weasel )
A.C.S.R conductor 50mm² ( Rabbit)
A.C.S.R conductor 100mm² (Dog)
Dismantling of overheated/Damaged/ worn out Conductor and Bundling.
A.C.S.R conductor up to 50mm² (Squirrel / Weasel)
A.C.S.R conductor 50mm² (Rabbit)
A.C.S.R conductor 100mm² (Dog)
Thickening of ACSR conductor in LT/HT Line
Thickening from 20mm² to 30mm²
Thickening from 30mm² to 50mm²
Thickening from 50mm² to 100mm²
Erection of guy rod complete
LT Line
HT Line
Tightening of Loose guy wire
Dismantling of D.Wood/ broken/under size pole in HT/LT Line.
Fixing of Jumper sets
HT Line
LT Line
Laying and stringing of overhead LT(3.5Core )/11 KV PVC/XLPE Insulated cable
Upto 16 mm² - 35mm²
Above 35mm² - 70mm²
Above 70mm² - 120mm²
Above 120mm² and including 300mm²
Laying of single core 3P 4W LT U/G Cable
Laying of 3½ core 3P 4W LT U/G Cable
Laying of single core 2P 1W LT U/G Cable
Laying of 3½ core 2P 1W LT U/G Cable
Earthing of ST pole of all length
Spike Earthing
Pipe Earthing
Spiral Earthing
Survey, Route alignment
HT Line
LT Line
HT/LT Line Patrolling for locating of fault
Branch Cutting
Route clearance
Fixing of pre fabricated bracket and cross arm bed for placement of Transformer as per REC standard
Guard Netting (Single Span)
Installation/ Erection of equipments
L.A Set
D.O Set
Link Set
G.O Set
H.G Set
Iron work such as fabrication of steel work.
Drilling of holes
Loading of 11/0.4 KV Distribution transformer
Up to and including 100 KVA
Above 100 KVA upto and including 300 KVA
Above 300 KVA upto and including 630 KVA
Above 630 KVA upto and including 1500 KVA
Unloading of 11/0.4 KV Distribution transformer
Up to and including 100 KVA
Above 100 KVA upto and including 300 KVA
Above 300 KVA upto and including 630 KVA
Above 630 KVA upto and including 1500 KVA
Dragging of 11/0.4 KV Distribution transformer upto first 50 Mtr.
16 KVA upto and including 25 KVA
25 KVA upto and including 100 KVA
100 KVA upto and including 300 KVA
300 KVA upto and including 630 KVA
630 KVA upto and including 1500 KVA
Dragging of 11/0.4 KV Distribution transformer for every subsequent 10 Mtr.
16 KVA upto and including 25 KVA
25 KVA upto and including 100 KVA
100 KVA upto and including 300 KVA
300 KVA upto and including 630 KVA
630 KVA upto and including 1500 KVA
Mounting of Transformer on X-arm bed including HV and Earth connections.
Upto and including 25 KVA
Above 25 KVA upto and including 100 KVA
Above 100 KVA upto and including 250 KVA
Mounting of Transformer on plateform including HV and Earth connections.
300 KVA and 400 KVA
500 KVA and 630 KVA
1.0 MVA and 1.5 MVA
Erection/ Installation of LT Cable circuit complete job.
Upto and including 25 KVA
Above 25 KVA upto and including 100 KVA
Above 100 KVA upto and including 630 KVA
Above 630 KVA upto and including 1500 KVA
Dismantling of LT Cable circuit complete job.
Upto and including 25 KVA
Above 25 KVA upto and including 100 KVA
Above 100 KVA upto and including 630 KVA
Above 630 KVA upto and including 1500 KVA
Replacement of Bush/Rod of Distribution Transformer of Various capacities(HT Side)
Replacement of Bush/Rod of Distribution Transformer of Various capacities(LT Side)
Crimping of thimbles
25mm2 upto 70mm2
Above 70mm2 to 185mm2
Above 185mm2
Erection/ Installation of MCCB complete job
Fixing of service line.
Single phase upto 10 Mtr.
Single phase from11 Mtr. to 20 Mtr.per meter.
Single phase from 21 Mtr. to 30 Mtr.per meter.
Opening of service line and re-connection
Installation of Single Phase Energy Meter
Installation of Three Phase Energy Meter/ Prodigy Meter
Sealing of Energy Meter
Shifting of Single phase meter
Shifting of Three phase meter
Dismentling of Single Phase/Three Phase Meter
Laying and Stringing of 11 KV AB cable
25,35 and 50 mm2
70, 95 and 120 mm2
150, 185 mm2 and above
Dismentling of 11 KV AB cable
25,35 and 50 mm2
70, 95 and 120 mm2
150, 185 mm2 and above
Laying and Stringing of LT AB cable
25,35 and 50 mm2
70, 95 and 120 mm2
150 and 185 mm2
240 and 300 mm2
Dismentling of LT AB cable
25,35 and 50 mm2
70, 95 and 120 mm2
150 and 185 mm2
240 and 300 mm2
Installation and dismantling of LT AB cable jointing kit.
Installation of CT/PT Unit along with Meter (Complete job)
Fixing of heat shrinkable outdoor 11 KV Cable Kits of all specification
Fixing of heat shrinkable indoor 11 KV Cable Kits of all specification
Fixing of heat shrinkable LT Cable Kits of all specification
Fixing of danger Plates (HT/LT)
Fixing of Anti Climbing Device
Painting of MS cross arms, braces and clamp with one basecoat and two coats of aluminum Paint.
Painting of Steel Tubular poles including cross arm & clamp etc. with one basecoat and two coats of aluminum paint.
8 Mtr long
9 Mtr long
Fixing of spacers for LT lines
For 5 wire system
For 4 wire system
For 3 wire system
For 2 wire system
Installation of Meter Board/Meter Box including MCCB/Main Switch
Un-reeling and making of bundles of ACSR Conductor
A.C.S.R conductor up to 50mm² (Squirrel / Weasel / Rabbit)
A.C.S.R conductor 100mm² (Dog)
Erection of MS cross arm
up to 3 feet long
above 3 feet to 6 feet long
above 6 feet to 10 feet long
Erection of MS V-cross arm
Fixing of Braces
Fixing of HT Pin insulator
Fixing of LT Pin/Shackle insulator
Fixing of Disc insulator
Fixing of Top clamp for pin insulator (HT)/ PG clamp
Fixing of U/D clamp for LT insulators
Transportation of Distribution transformers (25KVA, 63KVA, 100KVA etc), ST Poles, Line Materials ,Conductor, DG's etc from Divisional Store Kargil to site or vice-versa.
Per Day Charges of Skilled labour (Electrician)
Per Day Charges of Unskilled labour
Topping up of less Transformer Oil etc. by way of Opening and refixing of top Cover of Transformer of various capacities.
Refitting of transformer lid after repair
Installing of pole mounted alongwith connections (Sub- Main Distribution Board) SMDB.
Dismantling of Pole mounted (Sub- Main Distribution Board) SMDB
Installation of Cantilever type cross Arm with braces of HT and LT network
M/S ALI MURTAZA
M/S HIGHLAND ENGINEERING
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .