Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹21.9 LAccepted-AOC 212 338 OLD DALANWALA DEHRADUN | DEHRADUN | DEHRADUN | UTTARAKHAND | 1 | Accepted-AOC Bidder lower price rater | |
| 2 | 2₹23.8 L+₹1.9 L (8.87%)Rejected-Finance 70 A COMPOSITE ENGINEERS RAJPUR ROAD LANE OPP HOTEL MADHUBAN DEHRADUN UTTARAKHAND 248001 | DEHRADUN | UTTARAKHAND | 248001 | 2 | Rejected-Finance Bidder Higher Price | |
| 3 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹23.4 L
EMD Value
₹70,200
Closing Date
2 Mar 2024, 1:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer, EDC (Urban),Dehradun
Office of the Superintending Engineer, EDC (Urban),Dehradun
Supply, Installation, Testing and Commissioning of upgradation of Electrical System by providing CSS at Devki Complex Moti Bazar, under EDSD Patel Road.
2024_UPCL4_69747_1
Tender No. 56/EDC(U)/2023-24
Open Tender
Electrical Works
Item Wise
120 days
as per tender specification
as per tender specification
4 documents required · 4 mandatory
₹1,180
Superintending Engineer, EDC (Urban),Dehradun
₹70,200
2 Aug 2024
17 Feb 2024
2 Mar 2024
18 Feb 2024
2 Mar 2024
18 Feb 2024
Decentralized
L.T. XLPE Unarmoured 1Cx35 Sqmm Cable for L.T. Box Termination
Indoor3C x 300 Sq.mm cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required
Outdoor 3C x 300 Sq.mm cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required
Suspension & Dead End Clamp with mounting arrangement
Insulation Piercing Connector for 150 to 150 sqmm sqmm
Insulation Piercing Connector for 150 to 35 sqmm sqmm
Plycarbonate 3 Ph. 4 w LT Distribution Box IP-65 , with Clamp and Nut bolt
Chemical type Earthing with coper bonded 17 mm dia x3000 mm length including accessories, and providing masonry enclosure with heavy duty CI cover plate of 300X300mm having locking arrangement and watering pipe etc. with 50 Kg Chemical . (As per IS 3043 ammended uptodate)
GI strip on surface or in recess for connections etc. as required.50x6mm
Pole Clamp incluiding Nut & Bolt For LT Cable mounting on Pole
Labour Charges
Carriage of ST Pole SP55 ( Galvanized)
Carriage of ST Pole SP33 ( Galvanized)
Carrage of L.T. Air Bunch cable(ABC) of 1.1 KV grade 3Cx120+1CX95+1x16 sq mm
Carrage of CSS from Existing place to Installtion site
Excavation of foundation pit of size 0.9x0.6x1/5th of length of pole in mixed soil. Errecting of Single support after fixing of all accessaries
Grouting of above supports with cement concrete in size 0.45x.0.45x1/6 mtr length of supports with CC Ratio 1:4:8 with cement, core sand & Stone ballast as per RESPO/UPCL construction manuals including back filling of earth and proper ramming. (All Grouting material with cement will be arranged by the contractor at his own cost)
Muffing/Plinthing of pole 300 mm above ground level size 0.45x0.45 mm in CC ratio 1:3:6
Overhouling of Old CSS 11/.433Kv ,990 KVA Transformer termination,RMU repairing , Busbar maintenance & CSS body painting etc
Repairing,Testing & assembling of Transformer winding as per Standerd
Providing ,Filtration,Testing & filling of Transformer oil in CSS Transformer
Providing and Fixing replacement for old and burned MCCB of rating 4 Pole 630 Amp
Providing/Repairing and fixing of old ACB of rating 1.1 KV 4 Pole 1600 Amp in existing CSS
Erection of 11kV/433 V UNIPACK Compact Secondary Sub-Station with 990 KVA DRY Type Transformer , H.T. Incommer 11 Kv,630 Amp,21KA VCB - 1 Nos & 11 Kv, 630Amp, 21 KA LBS- 1 Nos . ,LT Outgoings - 1.1 kV, 400 Amp, 36 KA MCCB -4 Nos
Erection of STP SP 55 Pole (Galvanized) for LT AB Cable laying
Erection of STP SP 33 Pole (Galvanized) for LT AB Cable laying
Erection of following sizes of XLPE insulated PVC sheathed, Aluminium conductor armoured power cable of 11 KV 3C X 300sq.mm. conforming to IS 7098 amended upto date.
Erection of L.T. Air Bunch cable(ABC) of 1.1 KV grade 3Cx150+1CX95+1x16 sq mm conforming to IS 7098 amended upto date.
Erection of Suspension & Dead End Clamp with mounting arrangement
Erection of Insulation Piercing Connector for 150 to 150 sqmm sqmm
Erection of Insulation Piercing Connector for 150 to 35 sqmm sqmm
Erection of Plycarbonate 3 Ph. 4 w LT Distribution Box IP-65 , with Clamp and Nut bolt
Erection of L.T. XLPE Unarmoured 1Cx35 Sqmm Cable for L.T. Box Termination
Erection and termination of Indoor/outdoor 3C x 300 Sq.mm cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required
Erection of Chemical type Earthing with coper bonded 17 mm dia x3000 mm length including accessories, and providing masonry enclosure with heavy duty CI cover plate of 300X300mm having locking arrangement and watering pipe etc. with 50 Kg Chemical . (As per IS 3043 ammended uptodate)
Erection of GI strip on surface or in recess for connections etc. as required.50x6mm
Erection of Pole Clamp incluiding Nut & Bolt For LT Cable mounting on Pole
Providing temprary trolly For 400 kva TF During The CSS Errection Work And Dismental After Completion of work.
Construction of RCC/ MS Structure foundation complete with Material for installtion of CSS as per Drawings provided by vendor and approved by engineer incharge
Earth work(All Kind of soil) in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5m.
Back filing of soil in trench after laying of HDPE pipe and Cable
Disposal of soil after completion of civil work and cleaning the area aprox 15 km from the site
Earth work( Hard Rock/ RCC/PCC ) in excavation & Repair by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m.
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50 x 50mm including strengthening with 2mm dia wire or nuts, bolts and washers as required also with nexessary provisions for opening arrangement - complete as per the direction of Engineer-in-Charge. Made of G.I. wire of dia. 4mm, PVC coated to achieve outer dia. Not less than 5mm in required colour and shade.
Dismentalling of old existing LT Rabbit/Weasel conductor line
Dismmantling of Old & used 400/250 KVA T/F from old existing plinth and opening of all connection at both ends i.e. HT/LT side with proper stacking at safe place
Dismentalling of old & Rusted pole
Safe Back Cartage of all Dismantaled DTR 400/250 KVA from work site to Store centre /JE store with loading and unloading at both ends (dist aprox 0-20km)
Safe Back Cartage of all Dismantaled pole from work site to Store centre /JE store with loading and unloading at both ends (dist aprox 0-20km)
Safe Back Cartage of all Dismantale, Conductor,MS maltable scrap from road site to Store centre with loading and unloading at both ends (dist aprox 0-20km)
Composite Engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .