Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.0 LAccepted-AOC | ₹33.0 L Quoted ₹33.7 L | L1 | Accepted-AOC LOWEST AND REASONABLE |
| 2 | L2₹37.1 L+₹3.4 L (10.0%)Rejected-AOC | ₹37.1 L+₹3.4 L (10.0%) | L2 | Rejected-AOC OTHER THAN LOWEST |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
4 Dec 2021, 6:00 pmClosed
GE(AF) TEZPUR
GE(AF) TEZPUR POST-SALONIBARI DIST- SONITPUR ASSAM-784104
REPAIR/REPLACEMENT OF FEEDER PILLAR PANELS,UG CABLES AND OTHER E/M WORKS AT AFS TEZPUR UNDER GE (AF) TEZPUR.
2021_MES_488114_1
GE(AF)/8603/2021-22
Open Tender
Civil Works
Item Rate
180 days
AFS TEZPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE(AF) TEZPUR
₹60,000
Yes
30 Jun 2022
13 Nov 2021
7 Dec 2021
13 Nov 2021
4 Dec 2021
22 Nov 2021
Amount
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil ,complete all as specified and directed.
Returning filling in soft/loose soil, including, spreading levelling watering and well ramming in layers not exc. 25 cm complete all as specified and directed.
Removing excavated soils to a distance not exceeding 50 Metres and depositing where directed at a level n. exc. 1.5 M above the starting point complete all asspecified and directed.
Taking down existing, galvanized steel tubing, 32 mm bore, of any grade,in trenches or fixed to poles/Walls etc,including all fittings, complete all as directed.
Taking down existing, galvanized steel tubing, 40 mm bore, of any grade,in trenches or fixed to poles/Walls etc,including all fittings, complete all as directed.
Taking down existing, galvanized steel tubing, 50 mm bore, of any grade, in trenches or fixed to poles/Walls etc,including all fittings, complete all as directed.
Taking down existing, galvanized steel tubing, 80 mm bore, of any grade, in trenches or fixed to poles/Walls etc,including all fittings, complete all as directed.
Taking out unserviceable, U/G cables, 1100 Volts grade from trenches/ducts/ poles etc of size 16 Sq. mm 4 Core complete all as directed.
Taking out unserviceable, U/G cables, 1100 Volts grade from trenches/ducts/ poles etc of size 25 Sq. mm 4 Core complete all as directed.
Taking out unserviceable, U/G cables, 1100 Volts grade from trenches/ducts/ poles etc of size 50 Sq. mm 3 ½ Core complete all as directed.
Taking out unserviceable, U/G cables, 1100 Volts grade from trenches/ducts/ poles etc of size 70 Sq. mm 3 ½ Core complete all as directed.
Taking out unserviceable, U/G cables, 1100 Volts grade from trenches/ducts/ poles etc of size 95 Sq. mm 3 ½ Core complete all as directed.
Taking out unserviceable, U/G cables, 1100 Volts grade from trenches/ducts/ poles etc of size 120 Sq. mm 3 ½ Core complete all as directed.
Taking out unserviceable, U/G cables, 1100 Volts grade from trenches/ducts/ poles etc of size 185 Sq. mm 3 ½ Core complete all as directed.
Taking out unserviceable, U/G cables, 1100 Volts grade from trenches/ducts/ poles etc of size 300 Sq. mm 3 ½ Core complete all as directed.
Taking out unserviceable, U/G cables, 1100 Volts grade from trenches/ducts/ poles etc of size 500 Sq. mm 3 ½ Core complete all as directed.
Disconnecting of incoming, outgoing cables and earthing lead and taking down carefully existing unserviceable LT Feeder Pillar-Box/Panel/Busbar Enclosure with all accessories, including removing unserviceable cubicle with accessories from site, complete all as directed.
Laying, jointing and testing of LT, XLPE insulated, PVC sheathed,armoured, heavy duty electric cables with aluminium conductor for working voltage up to and including 1100 volts, of Cross sectional area 16 Sq. mm, 4 core, complete all as specified and directed.
Laying, jointing and testing of LT, XLPE insulated, PVC sheathed,armoured, heavy duty electric cables with aluminium conductor for working voltage up to and including 1100 volts, of Cross sectional area 25 Sq. mm, 4 core, complete all as specified and directed.
Laying, jointing and testing of LT, XLPE insulated, PVC sheathed,armoured, heavy duty electric cables with aluminium conductor for working voltage up to and including 1100 volts, of Cross sectional area 50 Sq. mm, 3 ½ core, complete all as specified and directed.
Laying, jointing and testing of LT, XLPE insulated, PVC sheathed,armoured, heavy duty electric cables with aluminium conductor for working voltage up to and including 1100 volts, of Cross sectional area 70 Sq. mm, 3 ½ core, complete all as specified and directed.
Laying, jointing and testing of LT, XLPE insulated, PVC sheathed,armoured, heavy duty electric cables with aluminium conductor for working voltage up to and including 1100 volts, of Cross sectional area 95 Sq. mm, 3 ½ core, complete all as specified and directed.
Laying, jointing and testing of LT, XLPE insulated, PVC sheathed,armoured, heavy duty electric cables with aluminium conductor for working voltage up to and including 1100 volts, of Cross sectional area 120 Sq. mm, 3 ½ core, complete all as specified and directed.
Laying, jointing and testing of LT, XLPE insulated, PVC sheathed,armoured, heavy duty electric cables with aluminium conductor for working voltage up to and including 1100 volts, of Cross sectional area 185 Sq. mm, 3 ½ core, complete all as specified and directed.
Laying, jointing and testing of LT, XLPE insulated, PVC sheathed,armoured, heavy duty electric cables with aluminium conductor for working voltage up to and including 1100 volts, of Cross sectional area 300 Sq. mm, 3 ½ core, complete all as specified and directed.
Laying, jointing and testing of LT, XLPE insulated, PVC sheathed,armoured, heavy duty electric cables with aluminium conductor for working voltage up to and including 1100 volts, of Cross sectional area 500 Sq. mm, 3 ½ core, complete all as specified and directed. NOTE:- (Applicable for BOQ/Schedule-A Serial Item No. 18 to 26) LT Cables will be issued under Schedule -B as " Free for Laying"
Re-laying, jointing and testing of LT, XLPE insulated, PVC sheathed,armoured, heavy duty electric cables with aluminium conductor for working voltage up to and including 1100 volts, of Cross sectional area 16 Sq. mm, 4 core, complete all as specified and directed.
Re-laying, jointing and testing of LT, XLPE insulated, PVC sheathed,armoured, heavy duty electric cables with aluminium conductor for working voltage up to and including 1100 volts, of Cross sectional area 25 Sq. mm, 4 core, complete all as specified and directed.
Re-laying, jointing and testing of LT, XLPE insulated, PVC sheathed,armoured, heavy duty electric cables with aluminium conductor for working voltage up to and including 1100 volts, of Cross sectional area 50 Sq. mm, 3 ½ core, complete all as specified and directed.
Re-laying, jointing and testing of LT, XLPE insulated, PVC sheathed,armoured, heavy duty electric cables with aluminium conductor for working voltage up to and including 1100 volts, of Cross sectional area 70 Sq. mm, 3 ½ core, complete all as specified and directed.
Re-laying, jointing and testing of LT, XLPE insulated, PVC sheathed,armoured, heavy duty electric cables with aluminium conductor for working voltage up to and including 1100 volts, of Cross sectional area 95 Sq. mm, 3 ½ core, complete all as specified and directed.
Re-laying, jointing and testing of LT, XLPE insulated, PVC sheathed,armoured, heavy duty electric cables with aluminium conductor for working voltage up to and including 1100 volts, of Cross sectional area 120 Sq. mm, 3 ½ core, complete all as specified and directed.
Re-laying, jointing and testing of LT, XLPE insulated, PVC sheathed,armoured, heavy duty electric cables with aluminium conductor for working voltage up to and including 1100 volts, of Cross sectional area 185 Sq. mm, 3 ½ core, complete all as specified and directed.
Re-laying, jointing and testing of LT, XLPE insulated, PVC sheathed,armoured, heavy duty electric cables with aluminium conductor for working voltage up to and including 1100 volts, of Cross sectional area 300 Sq. mm, 3 ½ core, complete all as specified and directed. NOTE:- (Applicable for BOQ/Schedule-A Serial Item No. 27 to 34) Old Serviceable LT Cables obtained from taking out vide BOQ/Schedule-A Serial Item No. 8 to 15 here in before shall be re-used.
Horizontal boring of holes, under road/ pavement / hard standing etc.,not exceeding 10 Metres in length, in any type of soil, suitable for passing through upto 100 mm bore, galvanised steel tubing,complete all as specified and directed.
Cutting chase for pass through cable protection pipe ,etc.in existing plain cement concrete pavement/hardstanding/aprons etc. and making good, cutting in plain cement concrete (1:3:6) Type C1(using 20 mm graded aggregate),exceeding 20 cm but not exc 50 cm girth, complete all as specified and directed.
Supply and filling in dry sand in cable trenches before and after the cables are laid, as in sand cushioning to cables complete all as specified and directed.
Supply and laying sub class ‘B’, bricks, in cable trenches, as cable protection complete all as specified and directed.
Re-laying old serviceable bricks, in cable trenches, as cable protection complete all as specified and directed. Note:-Old Serviceable bricks obtained from taking out vide BOQ/Schedule-A Serial Item No. 8 to 16 here in before shall be re-used.
Supply and Laying galvanized steel tubing, 32 mm bore, light grade, in trenches or fixed to poles/Walls etc, for cable protection, complete all as specified and directed.
Supply and Laying galvanized steel tubing, 40 mm bore, light grade, in trenches or fixed to poles/Walls etc, for cable protection, complete all as specified and directed.
Supply and Laying galvanized steel tubing, 50 mm bore, light grade, in trenches or fixed to poles/Walls etc, for cable protection, complete all as specified and directed.
Supply and Laying galvanized steel tubing, 80 mm bore, light grade, in trenches or fixed to poles/Walls etc, for cable protection, complete all as specified and directed.
Materials and Labour for Straight Through Joints, tubular sleeve type, for 1.1 KV Grade, underground cable including jointing kits and accessories complete for making joints, suitable for 3/3 ½ /4 core XLPE armoured, aluminium conductor cable, of size 25 sq. mm to 50 sq. mm, complete all as specified and directed. [Kit No.EPKJ 0130 of Make 'Raychem' or equivalent Model of Make M-Seal/3M]
Materials and Labour for Straight Through Joints, tubular sleeve type, for 1.1 KV Grade, underground cable including jointing kits and accessories complete for making joints, suitable for 3/3 ½ /4 core XLPE armoured, aluminium conductor cable, of size 70 sq. mm to 150 sq. mm, complete all as specified and directed. [Kit No.EPKJ 0137 of Make 'Raychem' or equivalent Model of Make M-Seal/3M]
Materials and Labour for Straight Through Joints, tubular sleeve type, for 1.1 KV Grade, underground cable including jointing kits and accessories complete for making joints, suitable for 3/3 ½ /4 core XLPE armoured, aluminium conductor cable, of size 185 sq. mm to 300 sq. mm, complete all as specified and directed. [Kit No.EPKJ 0144 of Make 'Raychem' or equivalent Model of Make M-Seal/3M]
Materials and Labour for Indoor/Outdoor End Terminations,heat shrink type, for 1.1 KV Grade, underground cable including jointing kits and accessories complete for making end termination,suitable for 3/3 ½ /4 core XLPE armoured, aluminium conductor cable, of size 185 sq. mm to 300 sq. mm, complete all as specified and directed. [Kit No.EPKT 0051 of Make 'Raychem' or equivalent Model of Make M-Seal/3M]
Materials and Labour for Indoor/Outdoor End Terminations,heat shrink type, for 1.1 KV Grade, underground cable including jointing kits and accessories complete for making end termination,suitable for 3/3 ½ /4 core XLPE armoured, aluminium conductor cable, of size 500 sq. mm to 630 sq. mm, complete all as specified and directed. [Kit No.EPKT 0083 of Make 'Raychem' or equivalent Model of Make M-Seal/3M]
Materials and Labour for earthing complete with galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.5M below normal ground level connected to galvanised steel earth lead strip 32 mm x 6 mm by means of bolts, nuts check nuts and washers of galvanised steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 54 cm x 54 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm centre to centre both ways, with one handle for lifting made out of 8 mm dia. MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing medium grade for protection of earth lead connection, necessary excavation and earth work in any type of soil complete all as specified and indicated on electrical plate No 3 of SSR Part –I (2009) including testing on completion.
Shri A. K. Goswami
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .