Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.1 CrAdmitted-Finance PO MELMURI MALAPPURAM DT KERALA 676517 | MELMURI | MALAPPURAM | KERALA | 676517 | ₹10.1 Cr | L1 | Admitted-Finance |
| Sl No | Description | Qty | Unit | T ABDUSSAMAD L1 |
|---|---|---|---|---|
| 1.00Appendix A-Construction of 8 m dia Intake well cum pump house at Thootha river in Thachanattukara GP | ||||
| 1.00 | OD212788/2024-2025:Construction of bund - Height 2.0 m ,bottom width 3.5 m and top width 2.5 m using Earth filled cement bags, and polythene sheet etc. for construction of well and leading channel as per Drawing and site condition and direction of engineer in charge including cost of all materials, labour charges, hire for tools and plants and all incidental charges etc complete | 150 | 1 meter | 21,500 ₹32.3 L |
| 1.00 | 100.3.8.11:Earthwork in open well excavation (in or under water) for wells of diameter above 6.0m and up to 9.0m in ordinary rock and conveying and depositing the spoil within initial lead of 50m and lift up to 1.5m including neat banking. | 199.07 | cum | 3,000 ₹6.0 L |
| 1.00 | 100.4.7:Granite rock blasting in wells, measured in solids, including collecting and stacking spoil for measurement within the initial lead of 50m and lift up to 3.0m (1.5m to 3.0m) but excluding bailing out water and including providing protection by earth filled cement bags (300 Nos. of earth filled cement bags / 10 m3 blasting) to avoid damages to the nearby structures) | 199.07 | cum | 6,500 ₹12.9 L |
| 1.00 | 100.4.8:Granite rock blasting in wells, measured in solids, including collecting and stacking spoil for measurement within the initial lead of 50m and lift up to 4.5m (3.0m to4.5m) but excluding bailing out water and including providing protection by earth filled cement bags (300 Nos. of earth filled cement bags / 10 m3 blasting) to avoid damages to the nearby structures) | 199 | cum | 7,300 ₹14.5 L |
| 1.00 | 100.4.9:Granite rock blasting in wells, measured in solids, including collecting and stacking spoil for measurement within the initial lead of 50m and lift up to 6.0m (4.5m to 6.0m) but excluding bailing out water and including providing protection by earth filled cement bags (300 Nos. of earth filled cement bags / 10 m3 blasting) to avoid damages to the nearby structures) | 199 | cum | 7,600 ₹15.1 L |
| 1.01 | OD214182/2024-2025:Granite rock blasting in wells, measured in solids, including collecting and stacking spoil for
measurement within the initial lead of 50m and lift up to 9.00m (6 m to 7.5m) but
excluding bailing out water and including providing protection by earth filled cement bags (300
Nos. of earth filled cement bags / 10 m3 blasting) to avoid damages to the nearby structures) | 199 | cum | 7,700 ₹15.3 L |
| 1.01 | OD212554/2024-2025:Granite rock blasting in wells, measured in solids, including collecting and stacking spoil for measurement within the initial lead of 50m and lift up to 9.00m (7.50 m to 9.00m) but excluding bailing out water and including providing protection by earth filled cement bags (300 Nos. of earth filled cement bags / 10 m3 blasting) to avoid damages to the nearby structures) | 199 | cum | 7,800 ₹15.5 L |
| 1.01 | OD212550/2024-2025:Granite rock blasting in wells, measured in solids, including collecting and stacking spoil for measurement within the initial lead of 50m and lift up to 10.50m (9.00 m to 10.50m) but excluding bailing out water and including providing protection by earth filled cement bags (300 Nos. of earth filled cement bags / 10 m3 blasting) to avoid damages to the nearby structures) | 169.56 | cum | 7,300 ₹12.4 L |
| 1.01 | OD212552/2024-2025:Granite rock blasting in wells, measured in solids, including collecting and stacking spoil for measurement within the initial lead of 50m and lift up to 12.00m (10.50 m to 12.00m) but excluding bailing out water and including providing protection by earth filled cement bags (300 Nos. of earth filled cement bags / 10 m3 blasting) to avoid damages to the nearby structures) | 169.56 | cum | 7,600 ₹12.9 L |
Tender Value
₹7.0 Cr
EMD Value
₹2 L
Closing Date
1 Sept 2025, 3:00 pmClosed
Superintending Engineer
PH CIRCLE, KWA, MALAPPURAM
Jal Jeevan Mission (JJM)-WSS to Vettathur Grama Panchayath Melattur Grama Panchayath and Keezhattur Grama Panchayath-Construction of 8 M diameter Well cum Pump house at Muriyankanni in Thachanattukara Panchayath and Substation buildings and Electrome
2025_KWA_773289_1
SE/PHC/MPM/14/2025-26
Open Tender
Civil Works - Water Works
365 days
Vettathur
Refer Tender Documents
8 documents required · 8 mandatory
₹11,025
₹2 L
PH CIRCLE, KWA, MALAPPURAM
6 Oct 2025
1 Jul 2025
2 Sept 2025
1 Jul 2025
1 Sept 2025
1 Jul 2025
1 Jul 2025 - 7 Jul 2025
7 Jul 2025
Amount
Appendix A-Construction of 8 m dia Intake well cum pump house at Thootha river in Thachanattukara GP
OD212788/2024-2025:Construction of bund - Height 2.0 m ,bottom width 3.5 m and top width 2.5 m using Earth filled cement bags, and polythene sheet etc. for construction of well and leading channel as per Drawing and site condition and direction of engineer in charge including cost of all materials, labour charges, hire for tools and plants and all incidental charges etc complete
100.3.8.11:Earthwork in open well excavation (in or under water) for wells of diameter above 6.0m and up to 9.0m in ordinary rock and conveying and depositing the spoil within initial lead of 50m and lift up to 1.5m including neat banking.
100.4.7:Granite rock blasting in wells, measured in solids, including collecting and stacking spoil for measurement within the initial lead of 50m and lift up to 3.0m (1.5m to 3.0m) but excluding bailing out water and including providing protection by earth filled cement bags (300 Nos. of earth filled cement bags / 10 m3 blasting) to avoid damages to the nearby structures)
100.4.8:Granite rock blasting in wells, measured in solids, including collecting and stacking spoil for measurement within the initial lead of 50m and lift up to 4.5m (3.0m to4.5m) but excluding bailing out water and including providing protection by earth filled cement bags (300 Nos. of earth filled cement bags / 10 m3 blasting) to avoid damages to the nearby structures)
100.4.9:Granite rock blasting in wells, measured in solids, including collecting and stacking spoil for measurement within the initial lead of 50m and lift up to 6.0m (4.5m to 6.0m) but excluding bailing out water and including providing protection by earth filled cement bags (300 Nos. of earth filled cement bags / 10 m3 blasting) to avoid damages to the nearby structures)
OD214182/2024-2025:Granite rock blasting in wells, measured in solids, including collecting and stacking spoil for measurement within the initial lead of 50m and lift up to 9.00m (6 m to 7.5m) but excluding bailing out water and including providing protection by earth filled cement bags (300 Nos. of earth filled cement bags / 10 m3 blasting) to avoid damages to the nearby structures)
OD212554/2024-2025:Granite rock blasting in wells, measured in solids, including collecting and stacking spoil for measurement within the initial lead of 50m and lift up to 9.00m (7.50 m to 9.00m) but excluding bailing out water and including providing protection by earth filled cement bags (300 Nos. of earth filled cement bags / 10 m3 blasting) to avoid damages to the nearby structures)
OD212550/2024-2025:Granite rock blasting in wells, measured in solids, including collecting and stacking spoil for measurement within the initial lead of 50m and lift up to 10.50m (9.00 m to 10.50m) but excluding bailing out water and including providing protection by earth filled cement bags (300 Nos. of earth filled cement bags / 10 m3 blasting) to avoid damages to the nearby structures)
OD212552/2024-2025:Granite rock blasting in wells, measured in solids, including collecting and stacking spoil for measurement within the initial lead of 50m and lift up to 12.00m (10.50 m to 12.00m) but excluding bailing out water and including providing protection by earth filled cement bags (300 Nos. of earth filled cement bags / 10 m3 blasting) to avoid damages to the nearby structures)
100.7.1:Bailing out water with 5HP engine and pump set including conveyance to the site, erecting, dismantling and taking back of engine and pump, cost of fuel lubricating oil and other stores pay of staff etc., complete.
100.7.2:Bailing out water with engine and pump set above 5HP up to 10HP including conveyance to the site, erecting, dismantling and taking back of engine and pump, cost of fuel lubricating oil and other stores pay of staff etc., complete.
100.7.4:Bailing out water with engine and pump set above 20HP up to 30HP including conveyance to the site, erecting, dismantling and taking back of engine and pump, cost of fuel lubricating oil and other stores pay of staff etc., complete.
100.6.1:Providing steel sheet shoring to the sides of the trenches to depths of above 4.00 m but not exceeding 6.00m using 6 mm M.S. sheet 0.50 M wide stiffen on edges with 50 mm x 50mm x 6 mm M.S. angles driving down vertically on either side one after another in lines and levels with suitable pile driving equipments and accessories to a maximum depth of 0.50 M below the bottom of the proposed excavation 0.5 M above ground level suitably braced by horizontal walling pieces at 75 x 150 mm x 8 mm angles on either side at intervals not exceeding 1.50M and horizontal screw jack type struts at 1.50M intervals and maintaining the shoring till the pipes are laid and works are completed, dismantling, cleaning and restacking for reuse including all labour, hire charges and conveyance for equipments, tools and plants and sundries etc. complete.
OD212555/2024-2025:DOWEL BARS - Supplying and providing MS dowel bars of size 16 mm dia of 2m long (1m in rock and 1m in concrete ) including drilling holes of 20mm dia to a depth of 1m in rock and filling the gap with cement grout( 0.10kg/each) etc complete
OD212845/2024-2025:Protected Granite blasting for open channel under wet condition with earth filled cement bags. Granite rock blasting measured in solids, including collecting and stacking spoil for measurement within the initial lead of 50m and lift upto 1.50m but excluding bailing out water and including providing protection by earth filled cement bags (300 nos. of earth filled cement bags/10m3 blasting)to avoid damages to the nearby structures
OD231638/2024-2025:Protected Granite blasting for open channel under wet condition with earth filled cement bags. Granite rock blasting measured in solids, including collecting and stacking spoil for measurement within the initial lead of 50m and lift upto below 1.50m up to 3.0m but excluding bailing out water and including providing protection by earth filled cement bags (300 nos. of earth filled cement bags/10m3 blasting)to avoid damages to the nearby structures
OD231639/2024-2025:Protected Granite blasting for open channel under wet condition with earth filled cement bags. Granite rock blasting measured in solids, including collecting and stacking spoil for measurement within the initial lead of 50m and lift upto below 3.0m up to 4.5m but excluding bailing out water and including providing protection by earth filled cement bags (300 nos. of earth filled cement bags/10m3 blasting)to avoid damages to the nearby structures
4.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
5.7:Reinforced cement concrete work in well - steining excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (Zone - III) : 3 graded stone aggregate 20 mm nominal size)
5.33.2:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level
5.22.3:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelCold twisted bars
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.19:Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges
5.9.16.1:Centering and shuttering including strutting, etc. and removal of form for: Edges of slabs and breaks in floors and wallsUnder 20 cm wide
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.12:Centering and shuttering including strutting, etc. and removal of form for:Well steining
5.11.1:Extra additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)
50.6.1.5:Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
6.35.1:Brick work with modular calcium silicate bricks machine moulded conforming to IS:4139, class designation 10 average compressive strength in super structure above plinth level up to floor V level in:Cement mortar 1:4 (1 cement : 4 coarse sand)
10.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover
10.7:Providing and fixing ball bearing for rolling shutters.
21.3.1:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness
21.1.1.2:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)
21.8.1:Filling the gap in between aluminium frame & adjacent RCC/ Brick / Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawing and direction of Engineer-in -Charge complete.Upto 5 mm depth and 5 mm width
14.29:Providing and fixing M.S. round or squre bars with M.S. flats at required spacing in wooden frames of windows and clerestory windows.
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)
13.7.2:12 mm cement plaster finished with a floating coat of neat cement of mix:1:4 ( 1 cement : 4 fine sand)
13.62.1:Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture .
10.26.3:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes
10.2:Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
13.71:Lettering with black Japan pint of approved brand and manufacture
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
100.31.1.12:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 600mm diameter, Class I.
100.98.504:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.0, Size 600mm.
Appendix-B-Construction of Approach bridge Substation building, shift room,Side Protection work at Muriyamkanni Well site
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
OD214335/2024-2025:Granite rock blasting measured in solids, including collecting and stacking spoil for measurement within the initial lead of 50m and lift up to 1.50m but excluding bailing out water and including providing protection by earth filled cement bags (300 Nos. of earth filled cement bags / 10 m3 blasting) to avoid damages to the nearby structures)
OD212557/2024-2025:DRY RUBBLE MASONRY _ Dry rubble without concrete leveling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
OD212556/2024-2025:DOWEL BARS - Supplying and providing MS dowel bars of size 16 mm dia of 2m long (1m in rock and 1m in concrete ) including drilling holes of 20mm dia to a depth of 1m in rock and filling the gap with cement grout( 0.10kg/each) etc complete
4.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
5.1.3:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
5.2.2:Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
5.33.1:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level
5.33.2:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
50.6.1.5:Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
13.4.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand)
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.46.1:Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
10.26.3:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes
14.29:Providing and fixing M.S. round or squre bars with M.S. flats at required spacing in wooden frames of windows and clerestory windows.
21.3.3:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 8 mm thickness
21.1.1.2:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)
21.8.1:Filling the gap in between aluminium frame & adjacent RCC/ Brick / Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawing and direction of Engineer-in -Charge complete.Upto 5 mm depth and 5 mm width
17.2.1:Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid
17.7.9:Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Surgeon Type wash basin of size 660x460 mm with single 15 mm C P. brass pillar taps with elbow operated levers ISI marked
17.28.1.2:Providing and fixing P.V.C. waste pipe for sink or wash basin including PVC. waste fittings complete. Semi rigid pipe40 mm dia
18.18.2:Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete:20 mm nominal bore
18.58.1.2:Providing and fixing PTMT grating of approved quality and colour. Circular type125 mm nominal dia with 25 mm waste hole
50.18.9.12.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 20 mm dia 12 Kgf/cm2 - External work - Exposed on wall
50.18.9.18.1:Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wall
50.18.9.19.1:Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall
100.98.48:Supply of PVC Tap
50.17.1.4:Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge.
17.73.1:Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm. weighing not less than 170 gms
18.22.1:Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet:100 mm diameter
17.29:Providing and fixing 100 mm sand cast Iron grating for gully trap.
17.31:Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
11.40:Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer) of Ist quality conforming to IS: 15622 of approved make in all colours, shades, except white, Ivory, Grey Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigments etc., complete.
11.41.2:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.
18.48:Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
10.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover
10.8.1:Extra for providing mechanical device chain and crank operation for operating rolling shuttersExceeding 10.00 sqm and upto 16.80 sqm in the area
10.7:Providing and fixing ball bearing for rolling shutters.
13.50.3:Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron /steel works
10.28:Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
13.52.1:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
9.119:Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wall thickness of 5 mm, made out of extruded 5 mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos. of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door fame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer's specification and direction of Engineer-in Charge.
9.120.1:Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and sized of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC 'C' channel of size 30 mm thickness, 70 mm width out of whicj 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5mm thick, 95 mm wide PVC sheet out of which75 mm shall be tapered in 45 degree on th inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mmx2) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail. paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded /sealed to the styles & rails with 7 mm (5 mm + 2 mm ) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. complete as per direction of Engineer -in-charge, manufacture's specification & drawing.30 mm thick plain PVC door shutters
OD212558/2024-2025: PVC Septic Tank - 35 to 50 flush capacity
2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
50.2.26.1:Filling with contractor own earth (excluding rock) in open areas in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge.
Appendix C - Supply,Erection,Testing and Commissioning of VT pump set at Well site
OD212595/2024-2025:Design, supply, erection getting approval , testing and commissioning of KWA approved reputed make Non pull out type with water cooling arrangements Vertical Turbine Pump set with of 415 V, 50 Hz LT Induction Motor , Bronze impeller , stainless steel shaft, column pipe assembly with stainer and all accessories, confirming the IS 1710.Including providing all allied electrical connections, interconnections to the header line, inspection of pumps and accessories as per the inspectorate and KSEB standards. And as per proceedings no KWA/HO/SP/333/2011/PUMPS. Dated 20/12/2011 of the MD KWA Jalabhavan TVPM, 9710/AE/15/2021/KWA dated 08.02.2023 Chief Engineer (Project and Operations ) KWA. (Includes extended warranty one year -150bHP to 200 HP. Pumps and motor -3sets ( 2 nos working at a time and one standby) Speed: Max 1500 RPM - 3Nos. combined Discharge (2 nos working at time)- 210.60 LPS Total Head - 94.0 m ( including suction head of 14.0m) Length of Pumping main -14.53km of 600 mm DI K9pipe, Suction head -14.00 M
OD212599/2024-2025:Supplying a complete integrated soft starter panel capable of operating the motor having a protection level of IP 40 or more with integrated bypass contactor in the panel and motor protection relay having parameters as per IE rules , with a power control MCCB and line power contactor , and the starting current shall be 2.5 - 3.5 times the normal full load current of motor with Ammeter , Voltmeter, KW & pf meter and Phase Indicators , space heaters , floor mounting type and having an insulation level of 1100V ( for 440 V supply ) and 7.6KV for ( 3.3 KV Supply ) and 14.2KV ( for 6.6 KV Supply ) . The standard is to be I.E.C 60947-4-2 .
100.37.14.1:In situ fabrication of M.S. pipes of size 600mm (I.D.) using 8mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete.
100.37.14.2:Fabricating M.S. flanges of diameter 600mm using 16mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.14.3:Cutting 600mm (I.D.) M.S. pipes for making bends and other specials by gas cutting including cost of gas, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.14.4:Welding 600mm (I.D.) M.S. pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.14.5:Grinding cut and weld edges of 600mm (I.D.) M.S. pipes during fabrication work including all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
Appendix D - Supply,Erection,Testing and Commissioning of 630 KVA 11KV/433 volts Indoor Transformer at Well site
OD212565/2024-2025:11 KV Equipments-Supply of all materials and providing 11KV sub station yard using 4nos. 175x85mm. ISMB joist of 9.5M height, 100x50mm. MS chanel cross arms, 2sets of 200A, 11KV gang operated AB switches with opertating handles of required length,2 sets of 9.6KV,6KA , Lightning Arrestors, 2sets of 11KV, D.O fuses, Pin insulators, Disc insulators and inter connections of the above items using 8mm dia copper wire with proper copper sockets , including all associated civil works and painting of all structurers with two coats of zinchromate primer and aluminium paint etc. complete as per standard construction practices approved by Kerala Electrical Inspectorate and relevant standards<br>
OD212561/2024-2025:11KV Metering Unit <br>Supply,erection, testing and commissioning of out door type metering unit consisting of the following accessories: <br>Current Transformer<br>CT Ratio 20/5 A( actual ratio may be decided after calculating connected load& maximum demand)<br>Burden 15VA<br>Accuracy Class 0.2S<br>Potential Transformer<br>PT ratio 11KV/110V<br>Burden -100VA.<br>Accuracy Class 0.2<br>The rate shall include the cost of testing the equipment at KSEB and all other incidental expences. The CT ratio should be fixed only after obtaining the power allocation from KSEB.<br>
OD212573/2024-2025:Supply of all materials and providing 2000mm wide 2500mm height weld mesh gate made out of 50 x 50 x 6mm Angles with necessary foundation locking arrangements etc. complete, including painting with two coats of zinchromate primer and aluminium paint as per standards.
OD212570/2024-2025:Supply of all materials and providing substation yard fencing using 50 x 50 x 6mm angle iron frame work of size 1500x2500mm fitted with weld mesh of 10 gauge and bolted the same to 100 x 50 x 6 mm vertical chanel erected at 1500mm c/c and 2500mm above ground level of substation yard and 500 mm below with 300 x300mm plain cement concrete (1:3:6) base using 40 mm granite aggregate and top surface finished neat.
OD212568/2024-2025:TOD Meter<br>Supply,erection, testing and commissioning of TOD meter with maximum demand in KVA suitable for the above out door metering set housed in a weather proof out door Kiosk.The rate shall include the cost of testing the equipment at KSEB and all other incidental expences. <br>
OD212587/2024-2025:11KV Switchgear(Indoor)<br>Supply, erection, testing and commissioning of 11KV, 630A, 350MVA, totally enclosed, single bus bar, floor mounting in metal clad, indoor extensible type flush mounted horizontal isolation and drawout type vacuum circuit breaker single panel system (1 no. VCB ) suitable for installation in 3 phase , 3wire, 50Hz. AC,11kv, effectively earthed supply system,comprising of motorised and spring assisted, independent, trip free closing mechanism and all metering equipments( A, V, KW, PF), protective relays etc. complete as approved by Kerala Electrical Inspectorate and relevant standards. Armoured multi core 2.5 Sqmm copper control cables shall be used for all external & internal interconnections. The cost of control cables both internal and external shall be included in the cost of HT panel.
OD212576/2024-2025:Supply, erection, testing and commissioning of 433V, 3phase,4 pole, 1000A, totally enclosed, single bus bar, floor mounting in metal clad, indoor extensible type flush mounted horizontal isolation and drawout type panel board comprising of 5 panel system (1 nos 800A MDO ACB as incomer, and 3 numbers 250 A microprocessor based MCCB (suitable for induction motor application) & 100A MCCB as outgoings) The incomer switchgears, & outgoing switchgears should be suitable for installation in 3 phase , 3wire, 50Hz. AC, 433V, effectively earthed supply system, trip free closing mechanisum and all metering equipments, protective relays, continuous earth bus at the bottom of the panel etc. complete as approved by Kerala Electrical Inspectorate and relevant standards. Armoured multi core 2.5 Sqmm copper control cables shall be used for all external & internal interconnections. The cost of control cables both internal and external shall be included in the cost of panel.
OD212578/2024-2025:11KV/433V, 630KVA Transformers (Indoor type suitable for parallel operation). Supply, erection, testing and commissioning of 630 KVA, 11KV/433V. 3phase, 50Hz. copper wound indoor type transformer with OLTC with digital AVR, 17 tap positions +5 to -15 % variation, with HV and LV side cable end box arrangements, with RTCC panel including first filling of oil etc. complete with all fittings as per IS 2026 and Kerala Electrical Inspectorate standards. Armoured multi core 2.5 Sqmm copper control cables shall be used for all external & internal interconnections . The cost of control cables both internal and external shall be included in the cost of Transformer.
OD212577/2024-2025:Supply, installation,testing and commissioning of Neutral CT for transformer protection, ratio - 125/5A(or suitable ratio), class 5P10 neutral CT with suitable size weather proof enclosure with iron frame work including all accessories.
OD212571/2024-2025::Power Distribution board (PDB)<br>"Supply,erection, testing and commissioning of 8 way MCB distribution board comprising to the following. 63A 4 pole MCB 1 No. as incomer with 63A 100mA ELCB and 20A TP MCB-2Nos. & 20A SP MCB- 6 Nos each. as outgoings, <br> With tinned copper busbars/cables, interconnection, housed in a suitable metal enclosure as per KEI standards fixed in open system."<br>
OD212574/2024-2025::Lighting Distribution board (LDB)<br>"Supply,erection, testing and commissioning of MCB distribution board comprising to the following. 40A TPN 4 pole MCB 1 No. as incomer with 40A 30mA ELCB, 18 nos 6 AMPS SP MCB as outgoings, <br> With tinned copper busbars/cables, interconnection, housed in a suitable metal enclosure as per KEI standards fixed in open system."<br>
OD212564/2024-2025:Cabling- Supply, laying, testing and commissioning of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable (1100 volts) clamped on wall/ceiling with clamps and saddle clips partly laid in cable tray/partly laid in trench. 3.5 core 400sqmm 1100 volts XLPE Aluminium cable
OD212589/2024-2025:3 core 240 sq mm11kv, XLPE AL Cable
OD212562/2024-2025: 3 core 185 Sq.mm,1100V LT XLPE AL Cable
OD212583/2024-2025:3.5 core 50Sq.mm. AYFY Cable
OD212559/2024-2025:4 core 16 Sq.mm.PVC AL. Cable.
OD212579/2024-2025:4 core 10 Sq.mm.PVC AL. Cable.
OD212572/2024-2025:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC sheathed / XLPE aluminium conductor cable of 1.1 kv grade as required 3 core 240 sq mmxLPE 11 KV Cable(Outdoor)
OD212588/2024-2025:3.5 core 400 Sq.mm. Cable end termination
OD212580/2024-2025:3 core 185 Sq.mm.1100v,LT XLPE AL Cable end termination (Indoor)
OD212590/2024-2025:3.5 core 50Sq.mm. AYFY Cable
OD219617/2024-2025: 4 core 16 Sq.mm.PVC AL. Cable.
OD212591/2024-2025:4 core 10 Sq.mm.PVC AL. Cable.
OD212582/2024-2025:Plate Earthing<br>Plate earthing as per IS by using CI/GI plate of size 1200*1200*12 mm etc complete
OD212563/2024-2025:Supply, laying and termination of the following sizes of copper strip/wires for earthing of substation, transformers, HTpanel boards,LT panel boards, equipments and inter connection of earth pits etc.<br>
OD212575/2024-2025:25x3mm copper strips.
OD212567/2024-2025:25x6mm GI strips
OD212569/2024-2025:32x6mm GI strips.
OD212566/2024-2025:MS Items.<br>Supply and fixing of 6mm thick chequered plate with required M.S. angle/plate supports over the masonry cable trench at substation and electrical control room. Angle and plate should be painted one coat of primer and two coats of enamel paint as required.
OD212585/2024-2025:Supply and fixing of M.S. angle cable tray for clamping the various sizes of cables in trenches, through walls, & trusses etc. as per KEI standards.
OD212560/2024-2025:Battery& Battery Charger.<br>Supplying, fixing, testing and commissioning of Lead acid cell battery 24V, 200AH capacity at 10hrs rate of discharge assembled with plante positive and pasted negative plates with inter cell, inter raw, interior connectiors etc. stand and cell insulators, sealed floats, nuts, bolt, washersetc with electrolyte of specific
OD212586/2024-2025:Supplying, fixing, testing and commissioning of automatic twin battery charger with distribution board with all instruments and protective devices etc. complete as per standards.
OD212584/2024-2025:Safety Items<br>Supply and providing the following safety items approved by Kerala Electrical Inspectorate and relevant standards.
OD212581/2024-2025:Provision for making drawing and getting approval from statutory bodies like electrical inspectorate and KSEBL( fees and other remittances will be made by KWA)
Appendix E:Design,Fabrication,Supply,Erection and Commissioning of 5 tonne capacity crane and gantry girder at raw water pump house
10.1:Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
OD219635/2024-2025:Design, manufacture, supply, testing and commissioning of overhead traverse trolley crane 5T capacity chain pulley block and geared trolley having wall to wall horizontal movement etc, for smooth functioning of crane as per IS specification including all fittings, conveyance, erection, testing, commissioning and incidental charges etc. (Rate based on non scheduled items sanctioned by the CE,NR,Kozhikode for this work vide letter no. KWA/CE/NR/D5 M-6412/2015 Dated 19.03.2025
OD219659/2024-2025:Erection and commissioning of HOT Overhead crane including providing and fixing suitable size 45 x 45 MS base plate 18mm thick over the existing RCC pillars 8 Nos brackets by drilling, fixing belt of suitable size and grouting with CM and welding LT girder ISHB 450 X 200 with MS plate and also providing LT rail with suitable end stoppage. This also includes provision for box type fabricated from rolled steel section and carriages of suitable construction with all good quality accessories like gears, wheels, axles, rubber buffers, bearing etc. The work also consists of all tools and equipments, labour, supervision, load testing, all safety devices and clarification of crane after completion of work by Kerala stoppers and carriages etc.(Rate based on non scheduled items sanctioned by the CE/NR,Kozhikode for this work previously vide letter number: KWA/CE/NR/D5 M-6412/2015 Dated 19/3/2015
Appendix F: Internal wiring and Yard lighting at Raw water pump house and transformer substation
OD219678/2024-2025:Supply of 20W LED Tube light 1200mm
OD219702/2024-2025:2.15.1 Supplying and fixing following rating, four pole, (three phase and neutral ),415 volts ,residual current circuit breaker (RCCB),having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections; testing and commissioning etc.as required 25 amps
OD219723/2024-2025:Supply Conveyance, installation, testing and commissioning of 70W LED street light output greater than 105 lumen/W 4000-6000K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV and Aluminum pressure die cast powder coated housing, acrylic cover complete with THD less than 10%,power factor greater than 0.98, RoHS compliant, duly wired up for use on 230V AC supply. Driver compartment should be separately accessible for maintenance (LM 79 & amp;amp;80 certificates from NABL accredited third party lab to be produced mentioning chip manufacturer
OD219748/2024-2025:DSR E&amp;amp;M 5.19 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/sub main wiring/cable as required
OD219756/2024-2025:DSR E&amp;amp; M2.1.1 Providing and fixing following capacity TP&amp;amp;N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections,etc as required. 32 Amp TP &amp;amp;N
OD219780/2024-2025:Supplying 300/305 mm sweep light duty exhaust fan working on 230V AC
OD219818/2024-2025:OEO 90.4.9- Charges for cutting holes suitable for accommodating exhaust fans above 305mm sweep and up to 450mm sweep including plastering colour washing etc. as required
OD220148/2024-2025:OEO 90.4.5.2 Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.2mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required. :1200mm sweep -5 star rated ceiling fan complete with 300 mm down rod, canopies, shackles and blades working on 230V/240V single phase A/C
OD220166/2024-2025:M.1.50.1 Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc as required up to 450mm sweep
OD220213/2024-2025:M 1.41 -Installation, testing and commissioning of pre-wired, LED fitting/compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required
OD220222/2024-2025:M 2.11- Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required
OD220238/2024-2025:M 2.10.1 Supplying and fixing 5 amps to 32 amps rating 240/415 volts curve miniature circuit breaker suitable for inductive load of following poles in existing MCB DB complete with connections, testing and commissioning etc. as required single pole
OD220250/2024-2025:M 2.3.1 Supplying and fixing following way, single pole and neutral sheet steel, MCB distribution board,240V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar,earth bar,din bar, interconnections, powder painted including earthing etc. as required (but without MCBIRCCB/ isolator 6 way, double door
OD224095/2024-2025:1.58 Supplying and fixing PVC batten/angle holder including connection etc.as required.
OD224106/2024-2025:1.33 Supplying and fixing 3 pin ,5 amp ceiling rose on the exiting junction box or wooden block including connection etc as required.
OD224196/2024-2025:Supplying and fixing suitable size GI box with modular plate and cover in FRLS on surface or in recess, including providing and fixing 6 pin 5/6 and amp:amp; ,15/1
OD224212/2024-2025:Supplying and fixing following size /modules, GI box along with modular base and cover plate for modular switches in recess etc as required 6 module (200mm X 75mm)
OD224228/2024-2025:Supplying and fixing modular blanking plate on the existing modular plate ,switch box excluding modular plate as required
OD224263/2024-2025:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate ,switch box including connections but excluding modular plate etc. as required
OD224269/2024-2025:Supplying and fixing following modular switch/ socket on the existing modular plate ,switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet
OD224294/2024-2025:Supplying and fixing following modular switch/socket on the existing modular plate, switch box including modular plate etc as required 5/6 amp switch
OD224326/2024-2025:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface /recess including cutting the wall and making good the same in case of recessed conduit as required. 32mm
OD224575/2024-2025:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required 25mm
OD224671/2024-2025:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required 20mm
OD224689/2024-2025:Supplying and drawing following sizes of FRLS PVC insulated copper conductor , single core cable in the existing surface/ recessed steel/ PVC conduit as required 3 X 4 sq.mm
OD224696/2024-2025:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel / PVC conduit as required. 3 X 2.5 sq.mm
OD224700/2024-2025:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel / PVC conduit as required. 3 X 1.5 sq.mm
OD224733/2024-2025:Wiring of twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit , 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm . FRLS PVC insulated copper conductor single core cable etc as required
OD224747/2024-2025:Wiring of group controlled (looped) light point/fan point /exhaust fan point/call bell point( without independent switch etc) with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit and earthing the point with 1.5 sq.mm . FRLS PVC insulated copper conductor single core cable etc as required
OD224752/2024-2025:Wiring for light point /fan point /exhaust fan point /call bell point with 1.5 sq.mm FRLS PVC insulated coper conductor single core cable in surface insulated copper conductor single core cable in surface /recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5sq. mm. FRLS PVC insulated copper conductor single core cable etc as required. Group C
OD224771/2024-2025:Earthing with copper earth plate 600mm x 600mm x 3mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7m long etc. with charcoal/ coke and salt as required
Bidder Name
T ABDUSSAMAD
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
BOQ.xls
BOQ • 0.45 MB
Tenderdocument.pdf
Tender Documents • 5.44 MB
Tenderdocument_2.pdf
Tender Documents • 0.19 MB
Tenderdocument_3.pdf
Tender Documents • 0.26 MB
Download all tender documents and submit your bid