| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Rejected-Technical 2ND FLOOR COMMERCE CENTRE KULUR KAVOOR ROAD KULUR MANGALORE D K 575 013 | DAKSHINA KANNADA | KARNATAKA | 575013 | Rejected-Technical As per TC proceedings |
Tender Value
₹27.3 L
Closing Date
20 Dec 2021, 3:00 pmClosed
Executive Engineer (E)
NMPT,Admin Building, Panambur, Mangalore, Karnataka
PROVIDING ILLUMINATION TO NORTHERN BREAK WATER ROAD AND PROVIDING LT UG CABLE IN PLACE OF OLD FOR HIGH MAST TOWERS AT RAILWAY MARSHALLING YARD
2021_NMPT_661367_1
8/3/2021/SDI/ETSII
Open Tender
Electrical Works
Works
90 days
New Mangalore Port, Panambur, Mangalore
Please refer Tender documents.
2 documents required · 2 mandatory
₹560
Yes
FA and CAO, NMPT, Panambur, Mangalore
Exempted
6 Jan 2022
4 Dec 2021
21 Dec 2021
4 Dec 2021
20 Dec 2021
4 Dec 2021
Part-I: Northern Break Water Street Light Works
Supplying of 3.5 C X 95 Sqmm 1.1 KV LT UG cable Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) , Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 in existing trench /duct/on wall/on black stone wall with SS saddles/ on poles with necessary clamps, screws etc. complete as required.
Supplying of 3.5 C X 50 Sqmm 1.1 KV LT UG cable XLPE OR Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 in existing trench /duct/on wall/on black stone wall with SS saddles/ on poles with necessary clamps, screws etc. complete as required.
Supplying of 3.5 C X 35 Sqmm 1.1 KV LT UG cable XLPE OR Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 in existing trench /duct/on wall/on black stone wall with SS saddles/ on poles with necessary clamps, screws etc. complete as required.
Digging of trench 0.6 mtr deep x 0.5 mtr wide refilling the trench to the required ground level and consolidating etc complete. Hard soil
Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150 mm all-round the cable
Supplying and laying of country bricks of size of 8”x4”x3” for cover the cable.
Labour Charges for laying of 3.5 C X 95 Sq mm LT UG cable in existing trench GI pipe/duct//Stoneware pipe as required.
Labour Charges for laying of 3.5 C X 50 Sq mm LT UG cable in existing trench GI pipe/duct//Stoneware pipe as required.
Labour Charges for laying of 3.5 C X 35 Sq mm LT UG cable in existing trench GI pipe/duct//Stoneware pipe as required.
Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV
3.5 c x 95 sqmm
3.5 c x 50 sqmm
3.5 c x 35 sqmm
Supply and erection of 8 Mtr RCC Pole including earth work, excavation, erection and fixing etc., complete as per the standard technical specification of BESCOM
Supplying and fixing GI cross arm on RCC pole top including clamps, bolts, nuts & washers-GI, suitable modification for fixing of 02 Nos. flood lights (120 watt/240 watt) and having size 50mmX50mmX6 mm - length - 1110mm (min)
Supply of 120 Watt LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with injection moulded polycarbonate/clear glass material, delivering supirior light output. (refer detailed technical Specifications)
Supply of 90 Watt LED Street light luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with injection moulded polycarbonate/clear glass material, delivering supirior light output. (refer detailed technical Specifications)
Supply of 240 Watt LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with injection moulded polycarbonate/clear glass material, delivering supirior light output. (refer detailed technical Specifications)
Fixing LED floodlight over existing pole cross arm including clamps, bolts, nuts and wiring using suitable capacity wires
Supplying heavy gauge PVC conduit pipe of following sizes confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc. and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700 mm using NF screws.
19/20mm dia 2 mm thick
40mm dia 2.5 mm thick
Supply and drawing 3 C X 2.5 Sq mm flexible multicore copper cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS:8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage up to 1100 volts as per IS-694:1990.
Providing stone masonary foundation for control panel and the dimension of the foundation 800(W) X 1000(H) X400(D) mm and the gap between the pillars is 350 mm for cable connection to the control panel. The foundation starts 300 mm below the ground after making 100 mm stone soiling and curing etc. The panel should be stand on the 4 stainless stell bolts (12mmX6") each bolt with four nuts & washers at 50 mm height from the foundation and complete.
Supplying, fixing and wiring earth electrode for panel using 40mm dia, 2.90 mm thick GI pipe 2.5 Mtr long with funnel with mesh and suitable size reducer fixed on the top of the electrode. The funnel should be enclosed in a CC chamber of 400 X400X400 mm with cast iron cover. The electrode shall have staggered holes of 12 mm dia and the electrode covered 150 mm alround with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the elctrode is to be established through GI strip 25X3 mm from electrode to control panel 2 runs using GI bolts, nuts and washers. (including supply of GI strips)
Supply and installation/fixing/provision of pole box with HRC fuse/MCB provision (02 Nos.) and suitable connector/terminal for 3ph/1 ph connections with loop-in and loop out terminals for 35 sq mm 3.5 C Al/Ar/Cu/Ar cable and branch out 2.5 sqmm 3 core Al/Cu PVC insulated cable, enclosed in a thermoplastic, polystyrene enclosure, which should be shockproof, safe, IP 65 (weather proof, rust proof, dust proof, water proof having internally embedded gasket with provision for cable entry thorugh IP65 Thermoplastic, polyamide glands and/or grommets. Size: 260mmX210mmX116mm
Supplying and fixing 125 amps, 25 ka, four pole Moulded case circuit breaker (MCCB) over existing panel board using necessary screws, bolts nuts, necessary phase seperators, handle and wiring complete. Protection of overload and short circuit with thermal magnetic/Micro processor release and earth fault as per IS-13947. (Icu=Ics)
Supplying and fixing 10 amps, DP, miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C type curve, indicator On/Off, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898
Part-II - Providing LT UG cable in place of old for High Mast Tower at Railway Marshalling Yard.
Supplying of 3.5 C X 95 Sqmm 1.1 KV LT UG cable Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) , Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 in existing trench /duct/on wall/on black stone wall with SS saddles/ on poles with necessary clamps, screws etc. complete as required.
Supplying of 4 C X 16 Sqmm 1.1 KV LT UG cable XLPE OR Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 in existing trench /duct/on wall/on black stone wall with SS saddles/ on poles with necessary clamps, screws etc. complete as required.
Supplying of 4 C X 10 Sqmm 1.1 KV LT UG cable XLPE OR Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 in existing trench /duct/on wall/on black stone wall with SS saddles/ on poles with necessary clamps, screws etc. complete as required.
Digging of trench 0.6 mtr deep x 0.5 mtr wide refilling the trench to the required ground level and consolidating etc complete. Hard soil
CC Cutting
Hard Soil
Supplying and laying Double walled corrugated (DWC) HDPE pipe of size of 63mm OD and 50mm ID as per IS 14930 part-II with necessary connecting sockets, couplings, Tees, bends, End - caps of same materials in existing trench/duct/on wall/on black stone wall with SS saddles/ on poles with necessary clamps, screws etc. complete as required for drawing the cable.
Supplying and laying Double walled corrugated (DWC) HDPE pipe of size of 40mm OD and 32mm ID as per IS 14930 part-II with necessary connecting sockets, couplings, Tees, bends, End - caps of same materials in existing trench/duct/on wall/on black stone wall with SS saddles/ on poles with necessary clamps, screws etc. complete as required for drawing the cable.
Supplying and Laying of RCC NP3 Hume pipe of 300 mm dia with required collar as complete job.
Supplying and laying of country bricks of size of 8”x4”x3” for cover the cable.
Labour Charges for laying of 3.5 C X 95 Sq mm LT UG cable in existing trench GI pipe/duct//Stoneware pipe as required.
Labour Charges for laying of 3.5 C X 95 Sq mm LT UG cable on wall/on pole with necessary saddles with minimum gap of 60 cm as required as complete job.
Labour Charges for laying of 4 C X 16 Sq mm LT UG cable in existing trench GI pipe/duct/on wall/Stoneware pipe/on pole as required.
Labour Charges for laying of 4 C X 10 Sq mm LT UG cable in existing trench GI pipe/duct/on wall/Stoneware pipe/on pole as required.
Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV
3.5 c x 95 sqmm
4 c x 16 sqmm
4 c x 10 sqmm
Extra Groove cutting in CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete upto 50 mm conduit in brick wall
Shifting of RCC pole Ware house and transporting to the Sub Division I premises
Sri Skanda Consultancy
J C Electricals
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .