GE AF AMBALA
GE AF AMBALA
GE AF/AMB-16/2021-22 REPAIRS AND MAINTENANCE OF FIRE ALARM SYSTEM, SPRINKLER SYSTEM, BOOM BARRIER, CHEMICAL EARTHING, VOLTAGE STABILIZER, RF PANEL, STP AND SUB-STATION AT SITE-II (RAJPURA) UNDER GE (AF) AMBALA
2021_MES_476392_1
GE AF/AMB-16/2021-22
Open Tender
Civil Works
Item Rate
120 days
GE AF AMBALA
ALL AS PER NIT AND TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
GE AF AMBALA
₹40,000
Yes
3 Jan 2022
20 Sept 2021
20 Oct 2021
20 Sept 2021
18 Oct 2021
5 Oct 2021
27 Sept 2021 - 1 Oct 2021
Amount
Supply and laying burnt bricks of sub-class 'B' designation 75 laid in trenches for cable protection complete all as specified and as directed
M&L for plain cement concrete, 1:2:4 type B1 (using 20mm graded stone aggregates) as in coping including all necessary formwork in any location / position complete all as specified and as directed
Supplying, installing, testing and commissioning outdoor type switch air break gang operated switch triple pole mechanically operated mounted on insulator and steel frame with operating mechanism worked from ground level for current rating up to 200Amps 11000V grade including 25mm dia GI medium grade pipe, supports worked from ground level vertically operated, with drop out fuse having 12 insulators, handle with locking arrangement, jumper wire including RYB coloured sleeves and taking down and disposing off old GOD complete all as specified and as directed
S&F bus bar chamber of size 1000x750x300mm suitable of 3 phase 433V outdoor type fabricated out of 3.15mm thick CRCA sheet double door with 200A rated aluminium busbar 4Nos., PVC sleeves (coloured red, yellow, blue and black) with suitable locking arrangments and four legged angle iron stand made of angle iron of size 40x40x6mm duly grouted in and including 1No. MCCB 160A 25kA FP (cost shall be included) foundation in PCC 1:2:4 type C1 using 20mm graded stone aggregates alongwith all necesary cable connections, lugs and cable glands including applying two coats of synthetic enamel paint (of approved tint) over a coat of red oxide zinc chrome primer complete all as specified and as directed
Supply, installation, testing & commissioning of powder coated compartmentalized LT panel, of suitable size, front and back openable, indoor type, with louvers and air vents, symetrical with overload, short circuit and earth fault protection, having bus bar chambers with rated copper bus bar 3 phase 800A and half neutral, duly insulated with coloured PVC sleeves as per standard code, rigidly mounted on bakelite / DMC insulators (square / round with good insulation resistance), fabricated out of 3.15mm thick CRCA sheet steel, totally enclosed, dust proof, weather proof, vermin proof, double door with suitable locking arrangements and suitable for operation on 415V, 50Hz supply with gland plates, cable glands, lifting hooks, ventilating louvers, bus bars, inter connections, earthing, labeling electrical interlocking, suitable for termination of cables, mounted/fixed on and including MS angle iron stand /frame 40cm height from FFL, fabricated out of 50x50x6mm thick MS angle legs (4Nos.) duly grouted in ground in platform (as per manufacturer's instructions) painting all exposed metal surfaces with two coats of synthetic enamel paint (of approved tint) over a coat of red oxide zinc chrome primer with, accommodating and including the under mentioned switchgears and connecting up complete all as specified and as directed
M&L for maintenance to check serviceability of micro-processor based intelligent fire control system with panel 10 to 12 loops / zone with control panel, wiring and detectors of any type and locating fault therein and repairing and rectifying the fault by replacing faulty parts / accessories and reconnecting the entire system and testing on completion complete all as specified and as directed Notes: (i) Job shall be done by qualified technician / Engineer of OEM (ii) Defective parts replaced will be measured and paid separately under respective item (iii) System diagram in AutoCAD, of the entire system duly marked with detectors, hooters, fire extinguishers, etc. in A3 size shall be submitted in quadruplicate to the Engineer-in-charge (iv) Testing shall be done in presence of the Users, Engineer-in-charge and the Contractor. Test certificates shall be duly vetted by all concerned and shall be submitted alongwith RAR (v) One display chart duly framed (of size as directed) showing the complete system diagram of each building in AutoCAD shall be fixed on each floor. Cost of same shall be included in the quoted rate
M&L for installation and testing suitable licensed software for fire alarm control panel suitable for 10 to 12 loops / zones compatable with existing system complete all as specified and as directed Notes: (i) Job shall be done by qualified technician / Engineer of OEM (ii) Software shall be installed at requisite location / panel / terminals as directed (iii) Software shall be having minimum license vaidity of 3years from date of installation. The license code shall be made available to the Engineer-in-charge (iv) Testing shall be done in presence of the Users, Engineer-in-charge and the Contractor. Test certificates shall be duly vetted by all concerned and shall be submitted alongwith RAR (v) The Contractor shall be liable to reload/re-install in the event of software getting corrupted by any cause whatsoever. The Contractor shall ensure proper functioning of the entire system within the software control and shall take remedial measures as required in the event of any inconsistancy (vi) Cost of above shall be included in the quoted rate
Supplying, installing, testing and commissioning of analog addressable multi sensor smoke cum heat detector/sensor with hard addressing feature, with visible bi-colour LEDs for 360o viewing, operating voltage 17-28V DC, reset voltage <3V start up current 500uA, alarm current 5mA, remote output 2mA compatable with existing system, duly fixed with standard base and junction boxes where required on false ceiling / soffits, etc. including taking down old sensors from any location / position and disposing off complete all as specified and as directed
Supplying, installing, testing and commissioning of UV&IR flame / smoke detectors / sensor with triple sensing technology, cast alum enclosure, hammer tone grey cabe entry 2x1.5mm conforming to protection class IP-66, with protection glass compatable with existing system, duly fixed with standard base and junction boxes where required on false ceiling / soffits, etc. including taking down old sensors from any location / position and disposing off complete all as specified and as directed
Supplying, installing, testing and commissioning of manual pull station type-A, indoor use, re-setable with align keys, die cast housing having break glass rod & hammer, single gang mounting, fire red in colour, integrated with addressable panel through monitor module including taking down old call points from any location / position and disposing off complete all as specified and as directed
Supplying, installing, testing and commissioning of hooter / strobe rated at 112dBA @3m for audible annunciation and 75cd flashings at 1Hz with visual indication for addressable type fire system including taking down old hooters from any location / position and disposing off complete all as specified and as directed
Supplying, laying, jointing and testing 2 core 1.5sqmm copper conductor cable PVC insulated, passing through existing conduits for connecting up fire alarm panels to heat / smoke sensors, MCP, hooters, etc. including disposing off old cable complete all as specified and as directed
Supplying, laying, jointing and testing 3 core 16sqmm copper conductor cable, flat, PVC insulated, multi-stranded in connecting up motors, panels, etc. including disposing off old cable complete all as specified and as directed
S&F in repairs energy efficient LED flood light fitting (beamer), 120W, input voltage 230VAC, 50Hz with ingress protection IP 65, CRI>70, PF>0.95, operating at voltage range 140 to 270V, minimum 50000 burning hours, THD> 20, aluminium housing including all fixing arrangment like clamps, nuts, bolts, washers, 120W LED lamp with all accessories pre-wired and connecting with twin core twisted flexible copper conductor cable with all necessary staging, etc. for fixing at any locations including taking down and disposing off old fitting complete all as specified and as directed
S&F in repairs energy efficient LED street light fitting (beamer), 90W, input voltage 230VAC, 50Hz with ingress protection IP 65, CRI>70, PF>0.95, operating at voltage range 140 to 270V, minimum 50000 burning hours, THD> 20, aluminium housing including all fixing arrangment like clamps, nuts, bolts, washers, 120W LED lamp with all accessories pre-wired and connecting with twin core twisted flexible copper conductor cable with all necessary staging, etc. for fixing at any locations including taking down and disposing off old fitting complete all as specified and as directed
M&L for earthing using copper earthing strip with galvanised steel earth plate electode 600x600x3mm thick buried directly in ground, earth pit not less than 2.25m deep below ground level connection to and including copper strip of size 32x6mm extended to 7.5m as earth lead by means of GI bolts, nuts, etc. with provision of charcoal and salt all as per electrical plate No. 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade), earth lead protection pipe 50mm medium grade with bends, elbow, etc. from earth plate to test point, excavation and earthwork in any type of soil, returning, filling, ramming and removing of soil to distance not exceeding 50m, make good to match with existing surface making PCC pit (earth chamber) having internal size 300x300x300mm and outer size 600x 600x600mm with RCC reinforced cover 50mm thick and testing on completion including making test points on wall as per SSR specifications complete all as specified and as directed
M&L for earthing using copper earthing strip with galvanised steel earth plate electode 600x600x3mm thick buried directly in ground, earth pit not less than 2.25m deep below ground level connection to and including copper strip of size 20x3mm extended to 7.5m as earth lead by means of GI bolts, nuts, etc. with provision of charcoal and salt all as per electrical plate No. 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade), earth lead protection pipe 50mm medium grade with bends, elbow, etc. from earth plate to test point, excavation and earthwork in any type of soil, returning, filling, ramming and removing of soil to distance not exceeding 50m, make good to match with existing surface making PCC pit (earth chamber) having internal size 300x300x300mm and outer size 600x 600x600mm with RCC reinforced cover 50mm thick and testing on completion including making test points on wall as per SSR specifications complete all as specified and as directed
Notes for serial item Nos. 17 & 18: (i) The cost of copper / GI earth continuity wire with GI pipe 50mm medium grade upto 7.5m is deemed to be included (ii) The earth chamber to be constructed 0.5m from edge of earth pit with necessary watering arrangement. The cost for the same is deemed to be included in above item (iii) Earthing shall produce desired earth resistance values as directed by the Engineer-in-charge (iv) The earth resistance shall be as desired by the installation. A guarantee for 3years of this criterion on a Rs. 100 stamp paper shall be given by the Contractor. The quoted rate shall be deemed to be inclusive of this aspect
Supply, installation, testing and commissioning maintenance free tripod chemical earthing system consisting of 3Nos. of solid copper earth rod of 17.2mm dia and 3m long made of high tensile low carbon steel, molecularly bonded with 99.9% electrolyitc grade copper on outer surface having 250microns (minimum thickness) with exothermically jointed copper bus bar of 150x25x3mm for long lasting and connecting each copper rod and the exothemically jointed bus bar, both CPRI tested on at leat 25kA fault current ensuring high current carrying capacity of the system and earth rod should be certified by laboratories confirming to comply with UL 467 international standards grounding and bonding equipment and each rod should be used with minimum 50kg earth enhancing compund that should be ROHS tested and have passed leaching sulpher, corrosion, resisitivity test shall be less than 0.05lhm mtr and international standard for earth enhancement compound by NABL acredited laboratory and each rod should be interconnected with 8mm dia copper clad steel conductor at the distance of 3m to make a shape of traingle with top of the bore finished with 40mm thick PCC in 1:2:4 type B-1, 75mm thick PCC in 1:4:8 type D-2 and back fill/JAM compund shall be covered with advanced polymer pit cover of 30x30mm size including taking out and disposing of old earthing complete all as specified and as directed
Notes for item No. 19: (i) The earthing shall comply to IS 3043, UL 467, BS/EN50164-7 (ii) The earth resistance shall be less than 01Ohm. A guarantee for 3years of this criterion on a Rs. 100 stamp paper shall be given by the Contractor. The quoted rate shall be deemed to be inclusive of this aspect (iii) To obtain earth resistance less than 01Ohm, if a combination two or more earthings are to be inter-connected or the length of the electrode/s is/are to be increased it shall be measured and paid as one earthing only (iv) Testing of earthing shall be carried out in presence of Departmental rep and requisite test reports shall be submitted (v) Cost of all excavation & earthwork required shall be deemed to be included in the quoted rate
Supply and mixing in proportions chlorination chemical highly efficient (high strength) calcium based granular disinfectant, more stable than chlorine gas, highly stable, in sealed container to check no sodium, iron/mercury/heavy metal contaminations, etc. complete all as specified Notes: (i) Paid vouchers of calcium based granular disinfectant shall be submitted (ii) The calcium based granular disinfectant shall be brought at site/store in sealed plastic container of appropriate capacity / size asked (iii) The brand of chemical shall be as approved by the GE
S&F in position stainless steel pipe 40mm bore with all required stainless steel fitting as required including taking down and disposing off old pipe complete all as specified and as directed
S&F in position MS pipe 40mm bore with all required MS fitting as required including taking down and disposing off old pipe complete all as specified and as directed
M&L for cleaninng by mechanical means entire STP of 200KLD capacity by cleaning the bar screen chamber-01No, oil & grease trap tank-01Nos., MBBR reactor-II -02Nos, tube settle tank -01No., chlorine contact tank-01No, treated water tank-01No by means of coir/wire brush and washing with interior with bleaching powder, separate the MBBR media, settler scrapper, etc. for reuse and including safety protection devices for working men while working and painting of steel frame, ladder, gates, pipeline of STP installation with two coats of super enameled paint of approved colour over one coat of red oxide zinc chromate primer including preparation of surfaces and two coats of acrylic exterior paint of approved colour including preparation of surfaces on all STP tank, re-commissioning and testing of STP complete all as specified and as directed
M&L for taking out and removal of dry sludge and vegetation growth over sludge accumulation bed, taking out unserviceable filter media consisting of stone, gravel, sand, etc. from dry sludge tank 06Nos. at sewage treatment plant and removing and disposing off the same outside MD land through bio-tanks, etc. and filling in filter media of the following sizes in required depths complete all as specified and as directed
(a) Pebbles 63 to 38mm size
(b Pebbles 38 to 19mm size
(c) Pebbles 19 to 12.7mm size
(d) Pebbles 12.7 to 4.7mm size
(e) Course sand of grain size 0.55 to 0.65mm
S&F MBBR media as per existing MBBR media for digesting sludge in STP plant complete all as specified and as directed
M&L for changing dual media filter and activated carbon filter of existing sizes of pebbles/activated carbon complete all as specified and as directed
(a) Activated carbon
(b) Quartz sand
(c) Pebbles 63 to 38mm size
(d) Pebbles 38 to 19mm size
(e) Pebbles 19 to 12.7mm size
(f) Pebbles 12.7 to 4.7mm size
Supplying and filling in bacteria for MBBR media by topping with fluidized aerobic bio-reactor (FAB factor) of moving bed aerobic bio reactor chamber for sludge digestion in STP plant complete all as specified and as directed
Supplying, fixing in position in proper alignment filter feed tank (dual filter media) fabricated out of MS sheet of required thickness suitable for STP capacity 200KL/day (as per relevant IS) with controlling valves fitted on the tank for flow regulation including taking out and disposing off old filter feed tank complete all as specified and as directed
Supplying, fixing in position in proper alignment filter feed tank (active carbon filter) fabricated out of MS sheet of required thickness suitable for STP capacity 200KL/day (as per relevant IS) with controlling valves fitted on the tank for flow regulation including taking out and disposing off old filter feed tank complete all as specified and as directed
Supplying, fixing in position in proper alignment PAC chemical dosing tank 500litres capacity with and including connecting pipe pipe, regulating valve of appropriate size and taking out and disposing off old tank complete all as specified and as directed
Supplying, fixing in position in proper alignment PE chemical dosing tank 500litres capacity with and including connecting pipe pipe, regulating valve of appropriate size and taking out and disposing off old tank complete all as specified and as directed
M&L for supplying, installing, testing and commissioning UPVC PAC chemical dozing pump OC of capacity 5kg/hour, with existing pressure and speed duly fixed with suction/delivery pipes, placed and fixed at any location including taking down and disposing off old/unserviceable pump from any location complete all as specified and as directed
M&L for supplying, installing, testing and commissioning UPVC PE chemical dozing pump OC of capacity 5kg/hour, with existing pressure and speed duly fixed with suction/delivery pipes, placed and fixed at any location including taking down and disposing off old/unserviceable pump from any location complete all as specified and as directed
M&L for supplying, installing, testing and commissioning non-clog pump set of capacity 200LPM at 12m head electrically operated single phase 240V duly fixed with suction/delivery pipes, placed and fixed at any location including taking down and disposing off old/unserviceable pump from any location complete all as specified and as directed
M&L for supplying, installing, testing and commissioning non-clog pump set of capacity 1700LPM at 12m head electrically operated three phase 415V duly fixed with suction/delivery pipes, placed and fixed at any location including taking down and disposing off old/unserviceable pump from any location complete all as specified and as directed
M&L for supplying, installing, testing and commissioning chemical dosing pump of capacity 6kg/hour, 10Pa pressure, comprising of diaphragm, nozzle, suction valve, PCB, head, etc. with and including 100litre PVC tank and taking down and disposing off old/unserviceable pump from any location complete all as specified and as directed
M&L for disconnecting, de-coupling of 12.HP air blower unit and taking out the air blower pump, compressor unit and fan from foundation carefully, checking all other parts for serviceability and replacing damaged / unserviceable minor components and spares viz. gasket packing, nuts, bolts, washers, bushes, oil filter, air filter, etc. greasing all required parts including welding, metaling, turning, polishing, lathe work, etc. in any location as per manufacturer's instructions, reinstalling in position, connecting up and testing after completion complete all as specified and as directed
M&L for disconnecting 3 phase electric connections from C/F pump, de-coupling of 3HP motor unit of filter feed pump from foundation carefully, checking all other parts for serviceability and replacing damaged / unserviceable minor components and spares viz. gasket packing, nuts, bolts, washers, bushes, oil filter, air filter, etc. greasing all required parts including welding, metaling, turning, polishing, lathe work, etc. in any location as per manufacturer's instructions, reinstalling in position, connecting up and testing after completion complete all as specified and as directed
M&L for disconnecting 3 phase electric connections from C/F pump, de-coupling of 0.75HP motor unit of raw water non-clog pump from foundation carefully, checking all other parts for serviceability and replacing damaged / unserviceable minor components and spares viz. gasket packing, nuts, bolts, washers, bushes, oil filter, air filter, etc. greasing all required parts including welding, metaling, turning, polishing, lathe work, etc. in any location as per manufacturer's instructions, reinstalling in position, connecting up and testing after completion complete all as specified and as directed
S&F MS pump shaft as per existing size and type complete all as specified and as directed
S&F ball bearing as per existing size and type complete all as specified and as directed
S&F impeller as per existing size and type complete all as specified and as directed
S&F pressure gauge dial type suitable for a pressure of 10kg/sqcm complete all as specified and as directed
S&F square tube for settler tank of existing size suitable for STP of capacity 200KL/day complete all as specified and as directed
M&L for disconnecting 3 phase connection and rewinding of motor 3HP of pumping set with suitable size of super enamelled copper winding of existing gauge and size including all insulation material, sleeves, sheet, etc. complete all as specified and as directed
M&L for disconnecting 3 phase connection and rewinding of motor 12.5HP of non-clog type submersible sewage pumping set with suitable size of super enamelled copper winding of existing gauge and size including all insulation material, sleeves, sheet, etc. complete all as specified and as directed
S&F in repairs Y axial flow fan impeller as per existing size and type complete all as specified and as directed
S&F in repairs V belt of size C-75 as per existing size and type complete all as specified and as directed
S&F in repairs cast iron V pulley as per existing size and type complete all as specified and as directed
S&F in repairs mild steel heavy gauge dampers as per existing size and type complete all as specified and as directed
S&F in repairs air presure release valve as per existing size and type complete all as specified and as directed
S&F in repairs ball bearing as per existing size and type complete all as specified and as directed
S&F in position UPVC pipe 40mm bore with all required UPVC fitting as required complete all as specified and as directed
Supply and mixing alums as per sample complete all as specified and as directed
M&L for poly alum chloride for settler tank complete all as specified and as directed
M&L for poly electrolite for settler tank complete all as specified and as directed
M&L for placing bar screen for FAB media in position, made out of SS suitable for STP capacity 200KL/day including taking out and disposing off old screen complete all as specified and as directed
M&L for MS pipes 80/100mm bore including bends, etc. as required including all necessary welding, etc. taking down / up old MS pipes and disposing off complete all as specified and as as directed
M&L for testing of raw / treated water as per norms / standard raw sewage characteristics from Govt approved laboratory complete all as specified and as directed Notes: (i) Testing shall be done as directed by the Engineer-in-charge from sources as detailed. Lab shall be as approved by the GE (ii) All collection of sample, storage, depositing in lab, collection of test reports, etc. shall be included in the quoted rate (iii) Test report shall be submitted by the Contractor for seeking any payment
M&L in repairs MS frame work of any type and size including all fabrication work, made of MS angle iron, channel, girders, rolled bar and flat iron, etc. quality conforming to Fe-410-W Gde-E-250 quality-A fabricated from structrual steel sections including nuts, bolts, washers, welding, belding cold or hot, polishing, drilling holes for bolts, in any shape or size asrequired including two coats of synthetic enamel paint (of approved tint) over a coat of zinc chrome primer complete all as specified and as directed
Notes for all items of BOQ for sewage disposal system: (i) The sewage disposal system shall be capable of treating the sewage so as to meet the outlet effluent quality as per the following parameters: (a) BOD<10mg/litre (b) COD-150mg/litre (c) DO- 2mg/litre or more (d) TSS- <10mg/litre (e) PH- 6.5 to 8.5 (f) Oil & grease- <10mg/litre (g) Coliform- <100MPN/100ml (h) Residual chlorine- >1mg/litre (ii) The tests of maintaining the above parameters shall be done in NABL accredited laboratory and test reports shall be submitted in duplicate
Notes contd.: (iii) All necessary precautions and all safety measures as per Municipality rules / relevant regulatory guidelines shall be taken by the Contractor in employing his mechnical means and workmen. No person shall be employed in direct contact with sewage wells, etc. in foul conditions to prevent any health hazards, etc. only mechanical means shall be used (iv) The Contractor shall be solely responsible for any mishap to any of labourer deployed and to equipment/machinery/plants/material, etc. brought at site for work and any lapses whatsoever during the execution, (v) The work shall be executed under the supervision of highly skilled tradesman / supervisor, (vi) The rates quoted shall be deemed to be inclusive of all the above aspects, and no claims whatsover shall be entertainable at later stages and or during execution
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .