Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.7 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹7.8 L+₹2.1 L (36.7%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹7.9 L+₹2.2 L (37.7%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹7.9 L+₹2.2 L (38.1%)Rejected-AOC 2ND FLOOR PAPPOOTTY COMPLEX VAZHAKULAM MUVATTUPUZHA KERALA 686670 | MUVATTUPUZHA | ERNAKULAM | KERALA | 686670 | L4 | Rejected-AOC L4 |
Tender Value
₹7.1 L
EMD Value
₹7,100
Closing Date
7 Jul 2021, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Managing Director
TRCMPU Ltd, Ksheera Bhavan, Pattom, Thiruvananthapuram
Refer NIT
2021_KCMMF_427816_1
623/TRU/PC/2021-22
Open Tender
Miscellaneous Works
Item Rate
20 days
P and I Office, Mannar
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
₹7,100
P and I Office, Mannar
20 Nov 2021
28 Jun 2021
8 Jul 2021
28 Jun 2021
7 Jul 2021
28 Jun 2021
28 Jun 2021 - 7 Jul 2021
2 Jul 2021
60 days
Wiring for light point/ fan point/ exhaust fan point with 1.5 sq.mm PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm PVC insulated copper conductor single core cable etc. as required.
1 No light point/ Exhaust Fan point controlled by 1 No. 6A SP Switch
1 No Ceiling fan point controlled by 1 No 6A SP switch and stepped electronic fan regulator.
1 No Ceiling fan point controlled by 1 No 6A SP switch without Fan Regulator.
1 No light point controlled by 2 No 6 A 2 way SP switch.
2 No light point controlled by 1 No 6 A SP switch.
3 No light point controlled by 1 No 6 A SP switch.
Wiring for circuit/ submain wiring along with earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire (For AC)
4R x 6 Sqmm Cu wire through flexible conduit
2R x 6 Sqmm Cu wire through flexible conduit
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supply and Wiring using one run of two pair telephone wire through existing PVC Conduits for Telephone socket.
Supply and Fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing of RJ11 telephone sockets.
Supply and Laying of CAT6 LAN Cable through existing PVC conduit.
Supply and Fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing of RJ 45 LAN sockets.
Supply and Laying of CCTV Cable through existing PVC conduit.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 Nos 3 pin 5/6 amps modular socket outlet and 2 Nos 5/6 amps modular switch, connection etc. as required. (Computer Point)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
1 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 20 amps modular socket outlet and 20 amps DP modular switch, connection etc. as required.
Supplying and fixing 3 pin 5/6 amps modular socket outlet on suitable GI box and modular plate and cover including connection etc. as required. (For Wall Fan)
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required
Distribution Board Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof double door Distribution Board including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/MCCB or isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required.
6 way Vertical type TPN MCCB DB
6 way TPN DB (DB 1 & 2)
12 way SPN DB (UPS DB & Outdoor DB)
Supply and fixing of the following accessories suitable for 50 Hz , AC supply conforming to IS 8828-1995/ IEC 60898 of the following current ratings in the existing MCB DB complete with connections, testing and commissioning etc. as required
100A 4P MCCB
40A TP MCB
32A DP MCB
40A, 4P, 30 mA RCBO
25A, DP, 30 mA RCBO
6A -32A SP MCB
MCB Dummy
Supply and Fixing 4 way MCB Enclosure
MV CABLE LAYING & END TERMINATION , SUPPLY AND LAYING OF ONE NO XLPE ALUMINIUM/COPPER, ARMOURED/ UNARMOURED POWER CABLE OF 1.1 KV GRADE OF THE FOLLOWING SIZES THROUH TRENCH/CABLE TRAY/ WALL
3.5C x 50 Sqmm Al
4C x 16 Sqmm Al
4C x 10 Sqmm Al
3C x 2.5 Sqmm Cu
2C x 6 Sqmm Al
Supply and making end termination with brass compression gland and aluminium/copper lugs for following size of PVC insulated and PVC sheathed/XLPE Aluminium conductor cable of 1.1KV grade as required
3.5C x 50 Sqmm Al
4C x 10/16 Sqmm Al
3C x 2.5 Sqmm Cu
2C x 6 Sqmm Al
Supply and Installation of outdoor end termination of cable of 1.1KV grade as required
EARTHING
Supply & Installation of Plate Earth with GI earth plate of size 600 x 600 x 6 mm and other accessories as per specifications and standared code of practice including excavation & refilling with coal etc and connected civil works
Earthing with GI earth pipe 2.7 meter long, 40mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. (UPS)
Supply and Laying of 6 swg bare copper.
Supply and Laying of 10 swg bare copper.
Copper Earth Bench made of 25x3mm copper
Light Fixtures & Fans Supply and Installation of the following light fittings, Fan,Exhaust Fan etc.
9 Watts LED lamp
9/12W square/ round ceiling light
5/7W square/ round ceiling light
20W LED Tube light
9W LED Surface mounted light
60W Building light
1200mm sweep BLDC ceiling fan.
900mm sweep BLDC ceiling fan.
300 mm sweep medium duty exhaust fan.
Supply and Fixing of Anchor bolt type fan hook.
Charges for cutting holes for installing exhaust fan
Supply and Installation of syntex box with terminal connector and connected accessories for mounting building light
Supply and Installation of dust and vermin proof, wall mounted, water proof Meter Box for accomodating 3 phase CT operated LT TOD Meter as per KSEB standards, with 3 Nos 100A Cut off fuse and Neutral Link and 100A 4P COS. (Cost of CTs & TOD Meter are not included)
Preparation of necessary documents and submission of application to the KSEB for power enhancement and regularising the connection.
P & S ASSOCIATES
Powertek Associates
Linsta Services
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .