Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.0 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹22.8 L+₹8.8 L (63.1%)Rejected-AOC DISTRICT SAS NAGAR GAURAV GOYAL VILLAGE JAWAHARPUR OPPOSITE TO IND SWIFT FACTORY DERABSAAI DISTT SAS NAGAR PUNJAB DERABASSI | L2 | Rejected-AOC L2 | |
| 3 | L3₹27.3 L+₹13.3 L (95.4%)Rejected-AOC PLOT NO 82A SECTOR 5 IMT MANESAR GURGAON HARYANA 122051 | GURUGRAM | HARYANA | 122051 | L3 | Rejected-AOC L3 | |
| 4 | Rejected-Technical A355 BALAJI BHAWAN PLOT NO 42 A SECTOR 11 CBD BELAPUR NAVI MUMBAI 400614 MAHARASHTRA | NAVI MUMBAI | THANE | MAHARASHTRA | 400614 | - | Rejected-Technical Not qualify the PQR of NIT | |
| 5 | Rejected-Technical E41 RAHUL KUMAR JHA E41 OKHLA INDUSTRIAL AREA PH 2 OKHLA PHASE 2 NEW DELHI DELHI 110020 | SOUTH EAST DELHI | DELHI | 110020 | - | Rejected-Technical Not Qualify the PQR of NIT |
| Sl No | Description | Qty | Unit | VARDAN ENVIROLAB LLP L3 | Rishabh Sahni L1 | CITRO LABS PRIVATE LIMITED L2 |
|---|---|---|---|---|---|---|
| 1.00 | Effluent water: Collection of sample , testing and reporting of effluent water parameter to be monitored for colour, temperature, pH, suspended solids, total dissolved solids, BOD , COD, Chloride, Oil and Grease, Zinc, Available Chlorine, Iron, Magnesium, Total Chromium, Copper, Total Phosphate,
suIphate,Sodium, Total Residual Chlorine, Other Corrosion
Inhibiting Material ( 02, H2S and CO2) etc. at DCRTPP,
HPGCL, Yamuna Nagar. | 192 | Nos. | 1,500 ₹2,88,000 | 350 ₹67,200 Lowest | 1,000 ₹1,92,000 |
| 2.00 | Ambient Air Quality: Collection of sample, testing and reporting of ambient air quality parameter to be monitored for SO2, N0x, PM10, PM2.5, 03, Lead (Pb), Carbon Monoxide (CO), Ammonia (NH3), Benzene (C6Hó), Benzopyrene (BAP), Arsenic (AS), Nickel (Ni) at DCRTPP, HPGCL, Yamuna Nagar. | 1,040 | Nos. | 1,300 ₹13,52,000 | 825 ₹8,58,000 Lowest | 1,250 ₹13,00,000 |
| 3.00 | STP Effluent Water: Collection of sample, testing and reporting of colony STP effluent water sample Parameters to be monitored for colour, temperature, pH, suspended solids, total dissolved solids, BOD , COD, Chloride, Oil and Grease, Zinc, Available Chlorine, Iron, Magnesium, Total Chromium, Copper, Total Phosphate, suIphate,Sodium, Total Residual Chlorine etc. at DCRTPP, HPGCL, Yamuna Nagar. | 8 | Nos. | 2,000 ₹16,000 | 1,000 ₹8,000 Lowest | 3,000 ₹24,000 |
| 4.00 | Drinking water: Collection of sample, testing and reporting of Drinking water quality of plant area and Colony parameter to be monitored as per IS 10500-2012 at DCRTPP, HPGCL, Yamuna Nagar. | 48 | Nos. | 1,000 ₹48,000 Lowest | 1,000 ₹48,000 Lowest | 2,000 ₹96,000 |
| 5.00 | ESP Efficiency Parameters: Collection of sample, testing and reporting of ESP Efficiency Parameters to be monitored for flue Gas Temperatures, Velocity of flue Emission in Dust, Particulate Matter and ESP Efficiency etc at DCRTPP, HPGCI, Yamuna Nagar. | 48 | Nos. | 5,000 ₹2,40,000 | 1,000 ₹48,000 Lowest | 1,500 ₹72,000 |
| 6.00 | Fly Ash: Collection of sample, testing and reporting of Fly Ash parameters to be monitored for fineness grading, particle size, un-burnt carbon, Loss on Ignition, Silica, Iron Oxide, Aluminum, Calcium Oxide, Magnesium, Sulphate, Copper, Zinc, Nickel, Cadmium, Titanium, Chloride, Lead, Mercury, Chromium, Alkali contents ( As Na0H) etc. at DCRTPP,
HPGCL, Yamuna Nagar. | 48 | Nos. | 2,000 ₹96,000 | 1,000 ₹48,000 Lowest | 1,500 ₹72,000 |
| 7.00 | Ground Water: Collection of Sample, Testing and reporting of ground water sample (Ash Dyke and Plant area) parameter to be monitored as per IS 10500-2012 at DCRTPP, HPGCL, Yamuna Nagar. | 28 | Nos. | 2,000 ₹56,000 | 1,000 ₹28,000 Lowest | 1,650 ₹46,200 |
| 8.00 | Meteorological: Collection of sample, testing and reporting of Meteorological date on hourly basis for 24 hours by recording Temperature, Wind Direction and Speed, Relative - Humidity and Rain Fall etc. at DCRTPP, HPGCL, Yamuna Nagar. | 24 | Nos. | 1,500 ₹36,000 | 1,000 ₹24,000 Lowest | 1,000 ₹24,000 Lowest |
| 9.00 | Stack Emission: Collection of sample, testing and reporting of stack emission parameter SPM, S02, NOx, CO and Mercury of both Unit -I and II at DCRTPP, HPGCL, Yamuna Nagar. | 48 | Nos. | 3,500 ₹1,68,000 | 1,000 ₹48,000 Lowest | 1,900 ₹91,200 |
| 10.00 | Surface water: Collection of sample, testing and reporting of Surface water quailty as per IS 10500-2012 around the Project site at DCRTPP, HPGCL, Yamuna Nagar. | 8 | Nos. | 2,000 ₹16,000 | 1,000 ₹8,000 Lowest | 2,000 ₹16,000 |
Tender Value
Refer Docs
EMD Value
₹31,300
Closing Date
24 Jun 2026, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
NEERAJ KAALIA
Admin building DCRTPP Yamuna Nagar
Regular Environmental Monitoring of Stack Emission, Ambient Air, Effluent Water, Fly Ash, ESP Efficiency, Colony STP Water, Ash Dyke Ground Water Sample, Meteorological Data, Surface Water, Drinking water of Plant Area, colony at DCRTPP, HPGCL, YNR
2026_HBC_529828_1
2026B6A908D1 4A37 4829 82B9 2E68B4A6ABC2711PGC
Open Tender
Civil Works
Works
720 days
DCRTPP
3 documents required · 3 mandatory
₹1,180
₹31,300
Yes
31 Jul 2026
17 Jun 2026
26 Jun 2026
17 Jun 2026
24 Jun 2026
17 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Effluent water: Collection of sample , testing and reporting of effluent water parameter to be monitored for colour, temperature, pH, suspended solids, total dissolved solids, BOD , COD, Chloride, Oil and Grease, Zinc, Available Chlorine, Iron, Magnesium, Total Chromium, Copper, Total Phosphate,
suIphate,Sodium, Total Residual Chlorine, Other Corrosion
Inhibiting Material ( 02, H2S and CO2) etc. at DCRTPP,
HPGCL, Yamuna Nagar. | 192 | Nos. | - | - |
| 2 | Ambient Air Quality: Collection of sample, testing and reporting of ambient air quality parameter to be monitored for SO2, N0x, PM10, PM2.5, 03, Lead (Pb), Carbon Monoxide (CO), Ammonia (NH3), Benzene (C6Hó), Benzopyrene (BAP), Arsenic (AS), Nickel (Ni) at DCRTPP, HPGCL, Yamuna Nagar. | 1,040 | Nos. | - | - |
| 3 | STP Effluent Water: Collection of sample, testing and reporting of colony STP effluent water sample Parameters to be monitored for colour, temperature, pH, suspended solids, total dissolved solids, BOD , COD, Chloride, Oil and Grease, Zinc, Available Chlorine, Iron, Magnesium, Total Chromium, Copper, Total Phosphate, suIphate,Sodium, Total Residual Chlorine etc. at DCRTPP, HPGCL, Yamuna Nagar. | 8 | Nos. | - | - |
| 4 | Drinking water: Collection of sample, testing and reporting of Drinking water quality of plant area and Colony parameter to be monitored as per IS 10500-2012 at DCRTPP, HPGCL, Yamuna Nagar. | 48 | Nos. | - | - |
| 5 | ESP Efficiency Parameters: Collection of sample, testing and reporting of ESP Efficiency Parameters to be monitored for flue Gas Temperatures, Velocity of flue Emission in Dust, Particulate Matter and ESP Efficiency etc at DCRTPP, HPGCI, Yamuna Nagar. | 48 | Nos. | - | - |
| 6 | Fly Ash: Collection of sample, testing and reporting of Fly Ash parameters to be monitored for fineness grading, particle size, un-burnt carbon, Loss on Ignition, Silica, Iron Oxide, Aluminum, Calcium Oxide, Magnesium, Sulphate, Copper, Zinc, Nickel, Cadmium, Titanium, Chloride, Lead, Mercury, Chromium, Alkali contents ( As Na0H) etc. at DCRTPP,
HPGCL, Yamuna Nagar. | 48 | Nos. | - | - |
| 7 | Ground Water: Collection of Sample, Testing and reporting of ground water sample (Ash Dyke and Plant area) parameter to be monitored as per IS 10500-2012 at DCRTPP, HPGCL, Yamuna Nagar. | 28 | Nos. | - | - |
| 8 | Meteorological: Collection of sample, testing and reporting of Meteorological date on hourly basis for 24 hours by recording Temperature, Wind Direction and Speed, Relative - Humidity and Rain Fall etc. at DCRTPP, HPGCL, Yamuna Nagar. | 24 | Nos. | - | - |
| 9 | Stack Emission: Collection of sample, testing and reporting of stack emission parameter SPM, S02, NOx, CO and Mercury of both Unit -I and II at DCRTPP, HPGCL, Yamuna Nagar. | 48 | Nos. | - | - |
| 10 | Surface water: Collection of sample, testing and reporting of Surface water quailty as per IS 10500-2012 around the Project site at DCRTPP, HPGCL, Yamuna Nagar. | 8 | Nos. | - | - |
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.78 MB
BOQ_608867.xls
BOQ • 0.26 MB
AD0156952.pdf
Additional Documents • 0.09 MB
529828Corigendum1final.pdf
PDF • 0.08 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .